• Title/Summary/Keyword: Port space

Search Result 473, Processing Time 0.029 seconds

Analysis of Volatile Fatty Acids in Air by Dynamic SPME (Dynamic SPME를 이용한 공기 중 지방산 분석)

  • Yu, Mee-Seon;Yang, Sung-Bong;Ha, Nam-Ki
    • Journal of Environmental Science International
    • /
    • v.19 no.12
    • /
    • pp.1447-1454
    • /
    • 2010
  • In this study, the detection limits of lower fatty acids in air were investigated by using Dynamic SPME(Solid Phase Micro-Extraction), i.e. improved Head Space - SPME method(HS-SPME). This Dynamic SPME, called SPDE(Solid Phase Dynamic Extraction), is the analytical method for volatile compounds in air with the extraction by using a stainless steel needle of which inner surface is coated with adsorption material and following the gas chromatographic analysis by inserting the needle into a injection port of GC and subsequently, desorption of the volatile compounds into a gas-chromatographic column. Extraction was carried out by passing the sample air through the needle with a suction pump which has been used for a detection tube. The result of measurement for the 6 lower fatty acids showed that the detection limits ranged from 0.10 ppm to 0.44 ppm and the linear correlation coefficients were over 0.99. Relative standard deviations obtained from 5 analytical repetition of a ca. 1.6 ppm standard mixture were in the range of 1.87%~2.47%. This method has been shown to be a adequate for the measuring C2~C5 fatty acids in air in the concentrations of over several hundreds ppb.

A Ship Scheduling Model for Raw Material Transportation with Yard Storage Constraints in a Steel Mill (재고수준을 고려한 제철원료 수송을 위한 선박 일정계획 수립 모형)

  • Seong, Deok-Hyun;Suh, Min-Soo;Kim, Sang-Won;Kim, Woo-Jin
    • Journal of Information Technology Services
    • /
    • v.10 no.3
    • /
    • pp.49-59
    • /
    • 2011
  • A ship scheduling model is presented for the raw material transportation problem with yard storage constraints in a steel mill. The problem is formulated as 0, 1 mixed integer programming considering such constraints as loading port conditions, ship size and hold capacity, unloading conditions, and yard storage space. In addition, inventory related constraints including safety stock are taken into consideration to support the continuous operations of steel making process. The proposed model has been implemented and applied successfully to a real world problem, and its results show the improvement of performance compared to the traditional method. For example, the arrival dates of ships are determined satisfying the constraints. The total inventory level is minimized at the stock yard as a result. Also, the safety inventory level is always kept at the planning stage, and the standard deviation of total inventory level is reduced significantly. Further research is expected to develop efficient heuristics to have a better response time for even larger scale problems.

Thermal Flow Analysis and Design of KSTAR Thermal Shield Panel by Numerical Method (수치해석을 통한 KSTAR 주장치 열차폐 패널 열.유동 특성해석)

  • 김동락;김광선;노영미;조승연;김승현
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.2
    • /
    • pp.73-77
    • /
    • 2002
  • In order to derive the detailed design of Thermal Shield Cryopanel. which plays a role to make the Tokamak Nuclear Fusion Equipment work at both static and efficient conditions the commercially available software package FLUENT Version 5.3, was utilized. This study investigated the effects of thermal sources and distributions on the temperatures of Lid. Body. Base. and EH-Port Cryopanel by the numerical technique whose grid generations cover the solid and 9as region of the panel. The physical model of the Thermal Shield Cryopanel is that the 10mm diameter of the pipe with 1mm thickness is soldered on the Stainless steel Panel with 4mm thickness. The heat fluxes to the panel are assumed to be by thermal radiation in the vacuum space and by conduction through the supporters. The inlet conditions of Helium gas are 20 atmospheric Pressures and 60K temperature. The panel shapes with cooling Pipes and the operational conditions to keep appropriate temperature distribution of Thermal Shield Cryopanel Have been found and suggested.

Research on Fourth Harmonic Mixer at W Band in the Imaging System

  • Xiang, Bo;Dou, Wenbin;He, Minmin;Wang, Zongxin
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.4
    • /
    • pp.316-321
    • /
    • 2010
  • This paper presents a novel fourth harmonic mixer with new structure. The traditional 3-ports fourth harmonic mixer and the novel fourth harmonic mixer are designed by ADS, HFSS and CST simulator. The mixers have been fabricated and tested. The size of the traditional 3-ports fourth harmonic mixer is $12{\times}15$ mm, and the best conversion loss is 18.7 dB according to the measurement. Since the traditional 3-port mixer size is too large to be ranked, we design a novel fourth harmonic mixer for imaging system. The width of the mixing module in the novel fourth harmonic mixer is only 3.65 mm, and this size is fully capable to meet the mixer unit space which is not greater than 5 mm. The simulation result shows that the mixer has good performance, and the experiment result shows that the best conversion loss of the novel fourth harmonic mixer is 16.3 dB at RF signal of 91.3 GHz.

Performance Evaluation of a Cylindrical Steam Reformer with Various Thermal Conditions (원통형 수증기 개질기의 열적조건 변화에 따른 개질성능 평가)

  • Han, Hun Sik;Kim, Seo Young;Karng, Sarng Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.6
    • /
    • pp.269-274
    • /
    • 2014
  • The experimental performance evaluation of a cylindrical steam reformer with various thermal conditions has been conducted. The bottom space of the cylindrical reactor was packed with Ruthenium (Ru) catalyst. A three-segment furnace was installed to create the axially variable boundary temperature distribution. Six K-type thermocouples were inserted into the catalyst layer, and three exhaust ports were fabricated on the side wall along the flow direction. The exhausted gases at each port were analyzed by using gas chromatograph (GC) system. The experimental results showed that the reforming reaction occurs intensively in the upstream region and more hydrogen is obtained when the intake gas is sufficiently heated up through the enhanced steam reforming (SR) reaction. The axially increasing boundary temperature setup provided the maximally accumulated reforming efficiency of 74.8%, when the reactor was placed at the 3rd section of the furnace.

Study on the Installation process and Spatial characteristics of Modern Meteorological Observatory Construction, Centering on the Busan Meteorological Observatory (부산측후소(釜山測候所)를 중심으로 본 근대기 측후소 건축의 설치과정과 공간적 특성에 관한 고찰)

  • Kim, Young-Boon;Kim, Ki-Soo
    • Journal of architectural history
    • /
    • v.23 no.2
    • /
    • pp.39-52
    • /
    • 2014
  • This study researched changes over time regarding the location and spatial characteristics of modern meteorological stations, and examined the characteristics of modern meteorological station construction using the location and spatial characteristics of the Busan Meteorological Station. First, meteorological stations were located in port areas, and then moved to high altitude areas for stable meteorological observation beginning in the transition phase. Here, office buildings and residences were joined, but were separated due to the increase in functions from the stabilization phase. Second, as for spatial composition, in the establishment phase, existing buildings were used, and the scale of newly constructed buildings differed according to time and area. However, after the Japan-Korea Annexation, with increased funds and increased observation equipment, floor plans subdivided by function started to appear. In the stabilization phase, space was subdivided with redundancy due to the increase in functions. In the wartime transition phase, '一' shaped floor plans with redundancy became the norm. Meanwhile, the location of the maritime customs where the first meteorological observations took place after the opening of the ports, and the location and construction of the Busan Temporary Observatory built in the meteorological observation transition phase (1905) were investigated. Also, through the investigation of the Busan Meteorological Observatory, newly constructed before 1934, the location and spatial characteristics of modern era meteorological observatories were studied.

Implementation of Picture Surveillance System using xHTML (xHTML을 이용한 화상 감시 시스템 구현)

  • 정경택;송병만;마석주;전용일;정동수
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.7
    • /
    • pp.1421-1426
    • /
    • 2003
  • In this paper, we implement a picture surveillance system using IBM-compatible PC with web camera. The reflex RGB data captured from WebCam is stored to HDD through USB port at every 5 seconds intervals. Also, if strangers are detected through Motion Detection routine, warning voice message is broadcasted and invasion message is transmitted by e-mail and transmit the e-mail title to mobile phone through WAP(Wireless Application Protocol) push. The detected image is stored to hard-disk in ‘month-day-hour-minute-second. jpg’ data type. And the image data is transmitted to web server through FTP(File Transfer Protocol) because invader can deletes or destroys the image data on hard-disk We implement a surveillance system which is able to utilize through internet regardless of time and space.

Effect of Supply and Return Locations of a Floor-Supply Cooling System on Thermal Comfort

  • Kim, Young-Il;Kim, Jo-Seph;Yoo, Ho-Seon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.4
    • /
    • pp.37-46
    • /
    • 2001
  • This study numerically investigates thermal comfort of a space cooled by a floor-supply air-conditioning system, in which three different combinations of supply and return locations, one floor-supply/ceiling-return and two floor-supply/floor-return, are treated. A complementary experiment is performed to validate the present numerical analysis, and the prediction agrees favorably with the measured data. In the numerical procedure, a simplified model mimicking the inlet flow through a diffuser is developed for efficient simulations. The calculated results show that the ceiling-return type is far better in terms of thermal comfort than the floor-return ones within the extent of this study, which seems to be caused by effective vertical penetration of the supply air against natural convection. It is also revealed that the arrangement of port locations in the floor-supply/floor-return system has insignificant effect on the cooling performance. For selecting a proper system, other characteristics including the heating performance should be accounted for simultaneously with the present considerations.

  • PDF

Let Us Make: Interrogating Personnel's Perception towards Makerspace in a Nigerian University Library

  • Igbinovia, Magnus Osahon;Alex-Nmecha, Juliet C.
    • International Journal of Knowledge Content Development & Technology
    • /
    • v.11 no.2
    • /
    • pp.23-36
    • /
    • 2021
  • Makerspace offers an innovative way for university libraries to render services and achieve its core objectives. However, there is low level of adoption in Nigerian university libraries, hence the need to investigate the personnel's perception towards makerspace as an innovative learning platform. To achieve this, the descriptive research design was used to elicit data with the aid of a structured questionnaire, from the 96 library personnel in John Harris Library, University of Benin. Of the 96 copies of questionnaire distributed, 68 copies were returned and analyzed using descriptive statistics. The results showed that the library personnel were familiar with makerspace even though they still require more information about it. Also, that makerspace gives students the opportunity to acquire ew skill and enhances collaboration among learners. Moreover, the study revealed that budget constraints, high cost and maintenance of equipments, erratic power supply and lack of staff training are some of the perceived challenges to makerspace implementation. Consequently, the study revealed that university libraries should strategize on how to increase allocation of funds, organize makerspace webinar for personnel, ensure stable electricity supply and create a dedicated space for makerspace in the library. In conclusion, makerspace will provide students with the technological exposure and creative abilities required for the future, and as such effective planning should be made for its deployment and sustainability in Nigerian university libraries.

A study on the fire characteristics according to the installation type of large smoke exhaust port in a small cross sectional tunnel fire (소단면 대심도 터널 화재시 대배기구의 설치형태에 따른 화재특성 연구)

  • Choi, Pan-Gyu;Baek, Doo-San;Yoo, Ji-Oh;Kim, Chang-Yong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.201-210
    • /
    • 2019
  • Recently, due to the efforts to mitigate traffic congestion and expansion of space efficiency, the construction of underground roads has been increased in big-scale cities. Since tunnels in the city have a higher chance for a fire leading to a great tragedy during a severe traffic jam than mountain tunnels, it is highly likely that it will be constructed as a tunnel, having a small cross section, for small vehicles. However, if they are constructed as such small-vehicle tunnels, it would be possible to reduce the design fire intensity while the concentration of harmful gases would increase due to a reduction in the small cross sectional area, led by a decrease in the tunnel height. In this study, behaviors of fire smoke by the installation interval and format of large-scale exhaust-gas ports were examined and compared in the analysis of temperatures and CO concentrations of a tunnel and its results were as the following. Although there were no significant differences in the smoke spreading distance between installation intervals, but in this study, 100 m was found to be the most effective installation interval. The smoke exhaustion performance was found to be excellent in the order of $4m{\times}3m$, $6m{\times}2m$, and $3m{\times}2m$ (2 lane) of the smoke spreading distance. Although there was no significant difference in the smoke spreading distance between formats of large-scale exhaust-gas ports, it was found that the smoke spreading distance was larger than other cases when it was $3m{\times}2m$ in the fire growing process. The analysis of smoke spreading distances by the aspect ratio showed that a smoke spreading distance was shorted when its the smoke spreading distance was found to be shorter when its traverse distance was relatively longer than its longitudinal distance.