• Title/Summary/Keyword: Port design

Search Result 1,763, Processing Time 0.032 seconds

Settlement Prediction Accuracy Analysis of Weighted Nonlinear Regression Hyperbolic Method According to the Weighting Method (가중치 부여 방법에 따른 가중 비선형 회귀 쌍곡선법의 침하 예측 정확도 분석)

  • Kwak, Tae-Young ;Woo, Sang-Inn;Hong, Seongho ;Lee, Ju-Hyung;Baek, Sung-Ha
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.4
    • /
    • pp.45-54
    • /
    • 2023
  • The settlement prediction during the design phase is primarily conducted using theoretical methods. However, measurement-based settlement prediction methods that predict future settlements based on measured settlement data over time are primarily used during construction due to accuracy issues. Among these methods, the hyperbolic method is commonly used. However, the existing hyperbolic method has accuracy issues and statistical limitations. Therefore, a weighted nonlinear regression hyperbolic method has been proposed. In this study, two weighting methods were applied to the weighted nonlinear regression hyperbolic method to compare and analyze the accuracy of settlement prediction. Measured settlement plate data from two sites located in Busan New Port were used. The settlement of the remaining sections was predicted by setting the regression analysis section to 30%, 50%, and 70% of the total data. Thus, regardless of the weight assignment method, the settlement prediction based on the hyperbolic method demonstrated a remarkable increase in accuracy as the regression analysis section increased. The weighted nonlinear regression hyperbolic method predicted settlement more accurately than the existing linear regression hyperbolic method. In particular, despite a smaller regression analysis section, the weighted nonlinear regression hyperbolic method showed higher settlement prediction performance than the existing linear regression hyperbolic method. Thus, it was confirmed that the weighted nonlinear regression hyperbolic method could predict settlement much faster and more accurately.

Development and Application of Penetration Type Field Shear Wave Apparatus (관입형 현장 전단파 측정장치의 개발 및 적용)

  • Lee, Jong-Sub;Lee, Chang-Ho;Yoon, Hyung-Koo;Lee, Woo-Jin;Kim, Hyung-Sub
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.12
    • /
    • pp.67-76
    • /
    • 2006
  • The reasonable assessment of the shear stiffness of a dredged soft ground and soft clay is difficult due to the soil disturbance. This study addresses the development and application of a new in-situ shear wave measuring apparatus (field velocity probe: FVP), which overcomes several of the limitations of conventional methods. Design concerns of this new apparatus include the disturbance of soils, cross-talking between transducers, electromagnetic coupling between cables, self acoustic insulation, the constant travel distance of S-wave, the rotation of the transducer, directly transmitted wave through a frame from transducer to transducer, and protection of the transducer and the cable. These concerns are effectively eliminated by continuous improvements through performing field and laboratory tests. The shear wave velocity of the FVP is simply calculated, without any inversion process, by using the travel distance and the first arrival time. The developed FVP Is tested in soil up to 30m in depth. The experimental results show that the FVP can produce every detailed shear wave velocity profiles in sand and clay layers. In addition, the shear wave velocity at the tested site correlates well with the cone tip resistance. This study suggests that the FVP may be an effective technique for measuring the shear wave velocity in the field to assess dynamic soil properties in soft ground.

Assessment of Design water level variation Due to Climate Change for Port Nam-Hyang, Ulleng-Do (기후변화 시나리오에 따른 울릉도 남양항의 설계수위 변화 평가)

  • Kwon, Kyong Hwan;Park, Jee Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.219-219
    • /
    • 2022
  • 지구 온난화와 함께 발생하는 해수면 상승은 한반도의 해안지역을 비롯하여 울릉도 등 도서지역 전반에 걸쳐 진행 중이다. 또한 해수면의 온도 상승으로 인한 열대저기압의 생성 시 에너지 공급이 증가하며 연안으로 내습하는 파랑 내습 에너지가 커지게 된다. 경상북도 울릉군에 위치한 남양항은 최근 2019년 태풍 다나스 및 2020년 태풍 마이삭 등에 의해 고파랑 혹은 침수 피해가 발생하여 항 내에서는 물양장과 선박이 파괴되고 방파제가 전도되는 등의 피해가 속출하였다. 동해안의 태풍 내습, 지구 온난화와 저기압 발달에 의한 수위 상승 등과 같은 다양한 해양기후를 고려한 연안 구조물의 파랑 영향을 검토하는 것이 중요할 것으로 판단되었다. 기상청 태풍센터에서 제공하는 1979년부터 2020년까지 한반도 해역에 내습한 태풍 중 울릉도에 영향을 미친 태풍은 18개로 울릉도 인근에 영향을 준 내습 태풍을 10년 단위로 분석해 보면, 1980년대 3개, 1990년대 2개, 2000년대 8개, 2010년대 3개, 2020년 2개로 2000년대에 울릉도 영향권에 들어간 태풍이 가장 많았으며, 심해파 추산 기간 이후 2020년 1년 동안 울릉도 인근으로 마이삭, 하이선과 같은 2개의 태풍이 연속적으로 영향을 주었다. 울릉도에 영향을 미친 18개 태풍을 대상으로 일본 기상청(JMA)에서 제공하는 1시간 바람장을 이용하여 파랑 후측 수치 모의를 수행하였으며, 해양수산부와 기상청 관측 부이를 이용하여 파랑에 대한 정확도를 확보하였다. 고파랑 내습 시 연안에 조우하는 수위 조건은 파랑 에너지의 증가를 결정하게 되며, 항만 구조물의 설계에 적용되고 있는 약최고고조위 이상(4대분조의 최대 조위)의 최극조위 조건에서 해안 구조물에 월파 및 침수 피해를 주는 요인으로 작용할 수 있다. 이를 바탕으로 울릉도 남양항에서 폭풍 시 내습한 최극고조위(0.65m)와 IPCC 5차 보고서에 제시한 최악의 시나리오(RCP 8.5) 조건에서 울릉도에서 확인된 0.79 cm 상승고를 반영하여 범람위험평가를 광역에서의 계산 결과를 입력자료로 하여 준 3차원 비 정수압 파랑 변형 수치 모형인 MIKE 3 Wave를 사용하여 실험하였다. 해수면 상승에 의한 수위 상승고는 연안 파랑 증가에 영향을 주었으며 연안 구조물의 침수 피해에 영향을 줄 것으로 판단되었다. 월파 차단, 파랑 차폐의 목적으로 건설되는 구조물의 규모 및 천단고 등을 설정하는데 설계 수위의 선정은 중요하다. 수치 실험 결과를 바탕으로 방파제 및 호안의 범람 위험 평가를 수행하고 구조물 설계 시 이러한 해수면 상승고가 반영된 설계가 중요하다는 것을 위험 평가를 통해 확인할 수 있다.

  • PDF

A Study on the Reinforcement Effect of Low Flow Mortal Injection Method Using Field Test (현장시험을 이용한 저유동성 몰탈주입공법의 보강효과에 관한 연구)

  • Junyeong Jang;Gwangnam Lee;Daehyeon Kim
    • The Journal of Engineering Geology
    • /
    • v.33 no.4
    • /
    • pp.599-609
    • /
    • 2023
  • In the seismic retrofitting of harbor breakwaters in Korea, the recovery rate is often uncertain due to site conditions and site conditions, and problems continue to arise. Therefore, in this study, we analyzed the recovery rate and compressive strength of the improved material through drilling survey by grouting confirmation method after applying low-fluidity mortar injection method, and furthermore, we checked the elastic modulus by downhole test and tomography to confirm the reinforcement effect of soft ground after ground improvement. The experimental results showed that the average shear wave velocity of the ground increased from 229 m/s to 288 m/s in BH-1 and BH-3 boreholes to a depth of 28.0 m, and the average shear wave velocity of the ground to a depth of 30.0 m tended to increase from 224 m/s to 282 m/s in the downhole test. This is believed to be a result of the increased stiffness of the ground after reinforcement. The results of the tomographic survey showed that the Vs of the soft ground of the sample at Site 1 increased from 113 m/s to 214 m/s, and the Vs of the sample at Site 2 increased from 120 m/s to 224 m/s. This shows that the stiffness of the ground after seismic reinforcement is reinforced with hard soil, as the Vs value satisfies 180 m/s to 360 m/s in the classification of rock quality according to shear wave velocity.

Case Study for Establishing City-level Waterfront Management Plan - Focusing on the New York City Comprehensive Waterfront Plan - (도시 단위 수변관리계획 수립을 위한 사례 연구 - New York City Comprehensive Waterfront Plan을 중심으로 -)

  • Jiwoon Oh;Yeonju Kim;Seongyeong Lee;Hansol Mun;Juchul Jung
    • Journal of Environmental Impact Assessment
    • /
    • v.33 no.3
    • /
    • pp.116-130
    • /
    • 2024
  • Historically, humans settled in waterside areas that provided abundant resources and water resources. Afterwards, as industrialization progressed, the city's waterfront contributed to the development of the city through water resources, transportation, and maritime trade. In response to changes in industrial structure, over the past few decades, the city's waterfront has transitioned from an industrial and port-oriented function to a public space function. And from the perspective of urban regeneration, research and design on sustainable waterfront space development are being promoted around the world. However, areas near waterfronts are geographically vulnerable to the direct impact of natural disasters caused by climate change, such as sea levelrise and floods. Therefore, it is essential to establish a systematic management plan to ensure the safety of citizens and publicness. Since the 1990s, New York City in the United States has been establishing a city-level waterfront space management plan to ensure the public nature, safety, and equity of waterfront spaces. On the other hand, in South Korea, there is a lack of research on city-level waterfront management plans. Accordingly, this study sought to find implications and policy improvement measures for domestic waterfront space planning by examining the development process and major policies of New York City's waterfront comprehensive plan.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016 (설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015 (설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.

A study on oral discomfort in gynecological cancer patients undergoing chemotherapy (화학요법을 받는 부인암환자의 구강불편감에 관한 연구)

  • 정재원
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.2
    • /
    • pp.372-389
    • /
    • 1995
  • The frequency with which administration of chemotherapy for gynecological cancer treatment is used has increased along with the use of surgery and radiotherapy Among the various side effects of chemotherapy, stomatitis causes a problem of function and sensation in the oral cavity. This oral discomfort can be categorized into two components ; perceived oral symptoms and observed oral symptoms. If the oral problem continues, it may cause infection, bleeding and nutritional deficiencies. As a result of this condition, compliance with the treatment process can be affected as well as the prognosis for the cancer patients. But as the oral discorrfort usually appears after chemotherapy, it is often not reported to the health care personnel as a patient problem. Without problem identification of the oral discomfort and ability to assess the problem, effective intervention cannot be planned. Therefore, this study was conducted to identify the pattern and the degree of oral discomfort due to cancer chemotherapy and thus to provide data for identification of the patient problem and for nursing assessment. The design of this study was a longitudinal de-scriptive study The subjects were in - patients who received chemotherapy under the diagnosis of gynecological cancer between Mar. 15, 1994 and May 15, 1994 at a general hospital in Seoul, Korea. The number of subjects was 64 and they were divided into two groups, one of 41 (A : 5FU & Neoplatin), the other of 23(B : Neoplatin, Cytoxan, Adriamycin), according to the treatment regimen. The data were collected for 24 days using self-re-port instruments. The instruments were the 「Perceived Oral Symptom Assessment Tool」 and 「Observed Oral Symptom Assessment Tool」 developed by this researcher. Data were analyzed using the SPSS-PC program, ANOVA, t-test, paired t-test and the Pearson Correlation Coefficient were applied. The results of this study are as follows : 1. In A regimen the peak time for perceived oral symptom scores was the fifth day after chemotherapy, and the tenth day for observed oral symptom scores. Both of the problems started on first day of chemotherapy and were not resolved completely until the 24th day after treatment. 2. In B regimen, the peak time for perceived oral symptom scores was on the seventh day after chemotherapy, and the eighth day for observed oral symptom scores. It was noted that perceived oral symptom scores were higher than observed oral symptom scores consistently for 24 days. Both also started on first day of chemotherapy, and were not resolved completely until the 24th day after chemotherapy. 3. There were no differences statistically in perceived oral symptom scores between A and B regimen. The loss of appetite and xerostomia caused the most severe discomfort in both of these two groups. 4. The were no differences statistically in observed oral symptom scores between the A and B regi moil. In the A regimen, the highest observed symptom scores were the lips, gingiva, tongue and buccal membrane in that order. But in the B regimen, the highest observed symptom scores were tongue, lips, buccal membrane and gingiva in that order. 5. In A regimen, the patients who had gingival edema and dentures had significantly higher perceived oral symptom scores. And those who had gingival edema and bleeding, foul odor and aphthous stomatitis had significantly higher observed oral symptom scores. 6. In B regimen, the patients who had the experience of stomatitis in the last course of chemotherapy had significantly higher perceived oral symptom scores. Those who had gingival edema had significantly higher observed oral symptom scores. 7. In the A regimen there was no correlation between lab values for lymphocytes and albumin with perceived oral symptom scores and observed oral symptom scores. In the B regimen, there was a significant negative correlation between lymphocytes and albumin with the observed oral symptom scores, but not between perceived oral symptom scores and lymphocytes and albumin values. In conclusion, the nurse should expect that the patient undergoing chemotherapy will complain severely about subjective discomfort and before objective physical change is observed. Also the patients who have chronic oral problems such as dentures, gingival edema and bleeding, foul odor, aphthous stomatitis will complain of severe oral discomfort due to chemotherapy.

  • PDF

A Comparative Study of Dry Matter Yield and Nutritive Value of Tall type and Tail + Short type Mixtures (상번초 및 상ㆍ하번초형 혼파초지의 건물수량 및 사료가치 비교 연구)

  • 이인덕;이형석
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.23 no.2
    • /
    • pp.121-128
    • /
    • 2003
  • This study was conducted to investigate the effect of tall type mixtures and tall+short type mixtures on dry matter yield, botanical composition and quality. The experimental design includes two mixture types: Tall type mixtures(TM); orchardgrass(Potomac) 40+tall fescue(Fawn) 20+Festulolium braunii (Paulita) 10+perennial ryegrass(Reveille) 10+timothy(Climax) 10+red clover(Kenland) 5+alfalfa(Vernal) 5%) and tall+short type mixtures(TSM); orchardgrass(Potomac) 40+tall fescue(Fawn) 20+Kentucky bluegrass(Newport, turf type) 10+redtop(Barricuda, turf type) 10+perennial ryegrass(Palmer III, turf type) 10+red fescue(Flyer II, turf type) 5+white clover(Regal) 5%. The dry matter(DM) yield was higher obtained in TSM than that of TM, but there was no significant difference between TM and TSM. In the chemical composition, there was no significant difference between TM and TSM, but the content of cellulose, lignin were higher in TM than those in TSM(p<0.05). Also, the content of acid detergent fiber which affected dry matter digestibility was higher in TM than that of TSM. The crude protein dry matter yield was not observed significant difference between TM and TSM, but digestible dry matter(DDM) yield was higher in TSM than that of TM. In botanical composition, tall fescue, alfalfa and orchardgrass were highly maintained in TM but white clover, tall fescue and orchardgrass were highly, and redtop, red fescue were continuously maintained in TSM. In this experiment, DM yields and quality of two mixture types were no difference. However, the tall+short type mixtures(TSM) were more effective in enhancing the dry matter digestibility and DDM yield, and in maintaining the various botanical composition.

A Study on Implementation and Performance of the Power Control High Power Amplifier for Satellite Mobile Communication System (위성통신용 전력제어 고출력증폭기의 구현 및 성능평가에 관한 연구)

  • 전중성;김동일;배정철
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.1
    • /
    • pp.77-88
    • /
    • 2000
  • In this paper, the 3-mode variable gain high power amplifier for a transmitter of INMARSAT-B operating at L-band(1626.5-1646.5 MHz) was developed. This SSPA can amplify 42 dBm in high power mode, 38 dBm in medium power mode and 36 dBm in low power mode for INMARSAT-B. The allowable errol sets +1 dBm as the upper limit and -2 dBm as the lower limit, respectively. To simplify the fabrication process, the whole system is designed by two parts composed of a driving amplifier and a high power amplifier. The HP's MGA-64135 and Motorola's MRF-6401 were used for driving amplifier, and the ERICSSON's PTE-10114 and PTF-10021 for the high power amplifier. The SSPA was fabricated by the RP circuits, the temperature compensation circuits and 3-mode variable gain control circuits and 20 dB parallel coupled-line directional coupler in aluminum housing. In addition, the gain control method was proposed by digital attenuator for 3-mode amplifier. Then il has been experimentally verified that the gain is controlled for single tone signal as well as two tone signals. In this case, the SSPA detects the output power by 20 dB parallel coupled-line directional coupler and phase non-splitter amplifier. The realized SSPA has 41.6 dB, 37.6 dB and 33.2 dB for small signal gain within 20 MHz bandwidth, and the VSWR of input and output port is less than 1.3:1. The minimum value of the 1 dB compression point gets more than 12 dBm for 3-mode variable gain high power amplifier. A typical two tone intermodulation point has 36.5 dBc maximum which is single carrier backed off 3 dB from 1 dB compression point. The maximum output power of 43 dBm was achieved at the 1636.5 MHz. These results reveal a high power of 20 Watt, which was the design target.

  • PDF