• Title/Summary/Keyword: Porcelain polishing

Search Result 30, Processing Time 0.021 seconds

A Study on the Estimation of Adhesive Stability According to Organic Inorganic Mixed Tile Bond Type for Application of Polishing Tile to Dry Wall System (건식벽체에 폴리싱타일을 적용하기 위한 유기.무기질 혼합계 타일접착제 종류에 따른 부착안정성 평가 연구)

  • 유재강;박성규;배기선;오상근
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2001.11a
    • /
    • pp.8-13
    • /
    • 2001
  • In recently, polishing tile(porcelain homogeneous polished tile) was used in the construction field as a finishing material. But, there happened some problems such as tile exfoliation by construction condition in early ages. Also, in the dry wall system which used to lightweight wall, for use of polishing tile on dry wall, the examination of adhesive stability of polishing tile is needed. In this Paper, adhesive strength of Polishing tile was investigated by tile bond types on gypsum board and non asbestos board coated by tar-urethane and polymer modified cementitious waterproofing membrane(Series I). Then, the effect of heat stress and vibration was estimated on gypsum and non asbestos board(Series II).

  • PDF

- Esthetic Retreatment of Old Restorations with Cervical Discolorations - (구 보철물 치경부 변색의 심미 재수복)

  • Kim, Hak-Su;Kim, Uk-Jung;Jo, Mun-Sang;Lee, Jong-Yeop
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.11 no.2
    • /
    • pp.33-36
    • /
    • 2002
  • As patients have concerned the esthetics of dental restorations, the porcelain fused to metal restorations have gain their popularity due to their strength and esthetic appearance for many years. However, metal collar in subgingival level of porcelain fused to metal restoration often causes black shadows. Inadequately positioned metal collar causes plaque depositions, gingival inflammations, black shadows, and discolorations of margin area. Those problems can be avoided by a clear finishing line, well-fabricated provisional restorations with precise margin and fine polishing, collarless porcelain fused to metal restoration, and all ceramic restoration. In this case report, collarless porcelain fused to metal restoration was used to treat cervical discoloration from old restorations.

  • PDF

Performance Evaluation of Organic-Inorganic Adhesives and Organic Adhesives for Polishing Tile Adhesion (폴리싱 타일 접착용 유·무기계 접착제와 유기계 접착제의 성능 평가)

  • Seo, Jong-Oh;Jeon, Jin-Ho;Park, Chang-Hwan;Cho, Sung-Hyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.211-212
    • /
    • 2023
  • Polishing tiles among porcelain tiles are more durable and aesthetic than ceramic tiles, so their demand has recently increased. In particular, since polishing tiles have a very low absorption rate, organic adhesives with chemical bonds are mainly used. However, organic adhesives have low economic efficiency and some volatile organic compounds (TVOCs). Therefore purpose of this study was to evaluate the performance of polishing tile adhesion by developing organic-inorganic adhesives, which have chemical bonds and mechanical bonds. As a result, since the amorphous chain and chemical bonds of the polymer in the tile adhesives, both tensile and shear adhesion strength were satisfied with the KS L 1592, KS L 1593, and the rate of length change itself in the thermal cycling was lower than organic adhesives. So it is thought that it is possible to replace some organic adhesives.

  • PDF

New Development of Eco-friendly cementitious Ceramic Tile Adhesive by Thick-Bed method for Polishing tile and Porcelain tile (폴리싱 및 포세린 타일 떠붙임용 시멘트계 친환경 타일접착제 개발)

  • Cho, Chang-Hwan;Lee, Duk-Yong;Lee, Jae-Min;Choi, Il-Joon;Eom, Joo-Il
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.62-63
    • /
    • 2019
  • Currently, polymer-based tile cement (Thin-bed method) and epoxy adhesive (Thick-bed method) are mainly used as tile adhesive for polishing and porcelain. In the case of epoxy adhesive, there is a low economic efficiency, there is a problem that the work efficiency is reduced by mixing the resin and the hardener. In particular, the epoxy contains a bisphenol A and amine component, there is a risk of workable disease when a worker is exposed to odor and harmful gases generated in the epoxy adhesive for a long time. Against this background, it is necessary to analyze the hazards of using epoxy adhesives indoors, and develop cementitious high performance tile adhesive products with significantly lower hazards than epoxy adhesives.

  • PDF

SURFACE ANALYSIS OF CERCE RESTORATIONS POLISHED BY DIFFERENT TECHNIQUE (연마방법에 따른 Cerec block의 표면 거칠기 비교)

  • Kim, Sung-Gwang;Vang, Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.1
    • /
    • pp.31-42
    • /
    • 1997
  • This study was performed to investigate the surface roughness of the Cerec Vita Mark II polished by various polishing techniques, compare with that of the Vintage enamel porcelain glazed by high temperature glazing technique. All of the Cerec specimen were finished with sequential use of high speed diamond burs(grit 45, 30 and $15{\mu}m$). The groups were divided into 5 groups : Group I : Cerec Vita Mark II block specimens polished with Sof-lex discs. Group II : Cerce Vita Mark II block specimens polished with Two Striper MPS. Group III : Cerce Vita Mark II block specimens polished with Enhance. Group IV : Cerce Vita Mark II block specimens polished with Porcelain laminate polishing FG kit. Group V : Vintage enamel porcelain glazed by high temperature glazing Technique. Each group was consisted of 10 specimens. The surfaces produced were examined quantitatively using a laser specular reflectance machine(Perthen RM600-s, Feinpruf Perthen GmbH., Germany) and qualitatively under SEM(JSM-5400, JEOL, Japan). The Results were as follows : 1. The arithmetic mean roughness value(Ra) in groups 1, 2, 3 and 4 was higher than that of group5. There was statistically significant difference(P<0.05). 2. The arithmetic mean roughness value(Ra) decreased in the following orders : group 1, group 2, group 4, group 3 and there was no statistically significant difference between group 1 and group 2, group 3, and group 4. There was statistically significant difference among group 1, 2, and group 3, 4 and group 5(P<0.05). 3. The maximum individual peak-to-valley-height(Rmax) decreased in the following orders : group 2, group 1, group 4, group 3, group 5 and there was no statistically significant difference between group 1 and 2, group 1 and group 4, group 3 and group 5. There was statistically significant difference among group 1, 2, and group 1, 4 and group 3, 5(P<0.05). 4. The treated surfaces of group 5 had smoother surface than that of groups 1, 2, 3, 4 with SEM.

  • PDF

Simulated occlusal adjustments and their effects on zirconia and antagonist artificial enamel

  • Alfrisany, Najm Mohsen;Shokati, Babak;Tam, Laura Eva;De Souza, Grace Mendonca
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.3
    • /
    • pp.162-168
    • /
    • 2019
  • PURPOSE. The aim of this study was to evaluate the effect of occlusal adjustments on the surface roughness of yttria-tetragonal zirconia polycrystal (Y-TZP) and wear of opposing artificial enamel. MATERIALS AND METHODS. Twenty-five Y-TZP slabs from each brand (Lava, 3M and Bruxzir, Glidewell Laboratories) with different surface conditions (Control polished - CPZ; Polished/ground - GRZ; Polished/ground/repolished - RPZ; Glazed - GZ; Porcelain-veneered - PVZ; n=5) were abraded (500,000 cycles, 80 N) against artificial enamel (6 mm diameter steatite). Y-TZP roughness (in ${\mu}m$) before and after chewing simulation (CS) and antagonist steatite volume loss (in $mm^3$) were evaluated using a contact surface profilometer. Y-TZP roughness was analyzed by three-way analysis of variance (ANOVA) and steatite wear by two-way ANOVA and Tukey Honest Difference (HSD) (P=.05). RESULTS. There was no effect of Y-TZP brand on surface roughness (P=.216) and steatite loss (P=.064). A significant interaction effect (P<.001) between surface condition and CS on Y-TZP roughness was observed. GZ specimens showed higher roughness after CS (before CS - $3.7{\pm}1.8{\mu}m$; after CS - $13.54{\pm}3.11{\mu}m$), with partial removal of the glaze layer. Indenters abraded against CPZ ($0.09{\pm}0.03mm^3$) were worn more than those abraded against PVZ ($0.02{\pm}0.01mm^3$) and GZ ($0.02{\pm}0.01mm^3$). Higher wear caused by direct abrasion against zirconia was confirmed by SEM. CONCLUSION. Polishing with an intraoral polishing system did not reduce the roughness of zirconia. Wear of the opposing artificial enamel was affected by the material on the surface rather than the finishing technique applied, indicating that polished zirconia is more deleterious to artificial enamel than are glazed and porcelain-veneered restorations.

A Study on the Estimation of Adhesive Stability According to Organic.lnorganic Mixed Tile Bond Type for Application of Polishing Tile to Dry Wall System (건식벽체에 폴리싱타일을 적용하기 위한 유기.무기질 혼합계 타일접착제 종류에 따른 부착안정성 평가에 관한 연구)

  • Oh, Sang-Keun;Lee, Gi-Jang;Yoo, Jae-Kang;Kim, Su-Ryun;Lee, Sung-Il
    • Journal of the Korea Institute of Building Construction
    • /
    • v.2 no.3
    • /
    • pp.163-170
    • /
    • 2002
  • Recently, polishing tile(porcelain homogeneous polished tile) was used in the construction field as a finishing material. But, there happened some problems such as tile exfoliation by construction condition in early ages. Also, for use of polishing tile in the dry wall system which used to lightweight wall, the examination of adhesive stability of polishing tile is needed. In this study, adhesive strength of Polishing tile was investigated by tile bond types on gypsum board and non asbestos board coated by tar-urethane and Polymer modified cementitious waterproofing membrane(Series I). Then, the effect of heat stress and vibration was estimated on gypsum and non asbestos board(Series II). As the result of study are the follows; (1) Polishing tile(600$\times$400mm) construction on waterproofing layer : Both laboratory estimation and spot examination sieve were happened that fall of tile because their hardening speed is late. (2) To using powder style adhesives in the dry wail with waterproofing layer : Adhesive strength of tile is Influenced by interface bond area and base side condition. (3) Shock and heat stresses : obvious decline of adhesive strength is not happened

EFFECT OF SURFACE ROUGHNESS ON BOND STRENGTH IN TITANIUM-PORCELAIN SYSTEM (타이타늄의 표면거칠기가 도재의 결합강도에 미치는 영향)

  • Kim, Sang-Hun;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil;Oh, Gye-Jeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.2
    • /
    • pp.182-190
    • /
    • 2007
  • Statement of problem: Titanium has many advantages of high biocompatibility, physical properties, low-weight, low price and radiolucency, but it is incompatible with conventional dental porcelain due to titanium's oxidative nature. Many previous studies have shown that they used the method of sandblast for surface treatment prior to porcelain application, the researches are processing about the method of acid etching or surface coating. Purpose: The purpose of this research is to study the effect on bond strength of surface roughness between titanium and porcelain with the same surface topography. Material and method: In this study, we evaluated the bond strength by using 3-point bending test based on ISO 9693 after classified 8 groups - group P : polished with #1200 grit SiC paper, group S10 : $1.0{\mu}m$ surface roughness with sandblasting, group S15 : $1.5{\mu}m$ surface roughness with sandblasting, group S20 : $2.0{\mu}m$ surface roughness with sandblasting, group S25 : $2.5{\mu}m$ surface roughness with sandblasting, group S30 : $3.0{\mu}m$ surface roughness with sandblasting, group S35 : $3.5{\mu}m$ surface roughness with sandblasting, group E : $1.0{\mu}m$ surface roughness with HCl etching. Results: Within the confines of our research, the following results can be deduced. 1. In the results of 3-point bending test, the bond strength of sandblasting group showed significant differences from one of polishing group, acid etching group(P<.05). 2. The bond strength of sandblasting groups did not show significant differences. 3. After surface treatments, the group treated with sandblasting showed irregular aspect formed many undercuts, in the SEM photographs. The bond strength of sandblasting group was higher than 25 MPa, the requirement of ISO 9693. Conclusion: In above results, bond strength of titanium and low-fusing porcelain is influenced more to surface aspect than surface roughness. And titanium has clinically acceptable bond strength below surface roughness of $3.5{\mu}m$.

A Study on the Development of Porcelain Bonded Ni-Cr Dental Alloy (도재소부용 Ni-Cr 보철합금 개발에 관한 연구)

  • Lee, Gyu-Hwan;Sin, Myeong-Cheol;Choe, Bu-Byeong
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.1
    • /
    • pp.37-46
    • /
    • 1985
  • Development of a dental Ni-Cr alloy system for porcelain veneering crown and bridge was studied in this research. The principles of alloy design were a) It should not contain toxic beryllium. b) It should have low melting Point. c) It should be easily ground and polished. d) It should possess an adequate strength to resist the deformational force In the mouth. e) It should be bondable Ivith porcelain by chemically. After investigating the effect of minor elements such as boron and rare earth metals on the mechanical properties of the Ni-Cr alloy system, the compromised ideal composition for dental use was determined. The composition was l9.6%, Cr, 5.6% Mo, 3.4% Si, 1, 0% Fe, 0.01% Ti, 0.5-1.0% B, 0.2-0.6% misch metal, balance Ni. To compare the performance of experimental alloy with commercially available alloys, the properties such as strength, melting point, and bond strength were measured. The results Ivere as follows: a) Boron increases the strength of the alloy but reduces the elongation. b) Misch metal increases the strength when the boron content is low, but does not increase the strength when boron content is high. And it reduces the elongation drastically, c) Mechanical strength of the experimental alloy was not superior to commercially available Be containing alloy, but handling performance such as castability, ease of granting and polishing, and cuttability were superior to the Be containing alloy.

  • PDF

Influence of Water Infiltration and Flexural Strength Change with Glazing Treatment of Dental Porcelain (치과도재의 Glazing 여부에 따른 수분침투 정도와 굽힘강도에 미치는 영향)

  • Lee, Ju-Hee;Lee, Chae-Hyun;Song, Jeong-Hwan
    • Journal of dental hygiene science
    • /
    • v.17 no.4
    • /
    • pp.358-367
    • /
    • 2017
  • The purpose of this study was to evaluate the influence of water infiltration and flexural strength changes in dental porcelain with glazing treatment. The block specimens were prepared as experimental materials, using feldspar type commercial dental porcelain; then, these were fired at $940^{\circ}C$ for 1 minute. The fired specimens were polished with a dimension of $40{\times}5.5{\times}5mm$. The specimens were distributed to two experimental groups: with and without glazing treatment specimens (n=5), and they were immersed in a solution of pH 7 for 3, 7, and 20 days at $40^{\circ}C$ after fabrication. To evaluate the flexural strength changes with water infiltration treatment in specimens with and without glazing, the 3-point flexural test was performed, using a universal testing machine until failure occurred. Starting powder and fired specimens consisted of amorphous and leucite crystalline phase. The Vickers hardness of fired specimens was more than 1.6 times higher than that of the enamel of natural teeth. According to porosimeter results, the specimens without glazing treatment exhibited a porosity of about 14.7%, whereas the glazed specimens exhibited the lowest porosity at about 1.1%. The average flexural strength of glazed specimens was higher than the flexural strength of specimens without glazing treatment (p<0.05). The flexural strength of all specimens with and without glazing treatment deteriorated with accelerated aging in the solution. In addition, significant differences between these two treatment groups were observed in all of the specimens treated at various water infiltration periods (p<0.05). The exposure of internal pores and micro-cracks in the surface due to polishing of the fired specimens influenced mechanical behaviors. Especially, the flexural strength in specimens without glazing treatment has shown significant degradation with the infiltration of water. Therefore, this study suggests that glazing processes can improve mechanical properties of dental porcelain.