• 제목/요약/키워드: Porcelain materials

검색결과 304건 처리시간 0.02초

Co/Fe 황화물의 혼합안료에 의한 도자기 표면의 상형성과 색변화 (Effects of Co/Fe Sulfate Pigments on the Colour and Phase of Porcelain)

  • 김남훈;신대용;김경남
    • 한국재료학회지
    • /
    • 제32권8호
    • /
    • pp.354-360
    • /
    • 2022
  • In this study, an Co/Fe coated porcelain using a cobalt and ferrous sulfate was sintered at 1,250 ℃. The specimens were investigated by HR-XRD, FE-SEM (EDS), Dilatometer, and UV-vis spectrophotometer. The surface of the porcelain was uniformly fused with the pigment, and white ware and celadon body specimens were densely fused to a certain thickness from the surface. Other new compounds were produced by the chemical reaction of cobalt/ferrous sulfate with the porcelain body during the sintering process. These compounds were identified as cobalt ferrite spinel phases for white ware and white mixed ware, and an andradite phase for the celadon body, and the amorphous phase, respectively. As for the color of the specimens coated with cobalt and ferrous mixed pigments, it was found that the L* value was greatly affected by the white ware, and the a* and b* values were significantly changed in the celadon body. The L* values of the specimens fired with pure white ware, celadon body, and white mix ware were 72.1, 60.92, 82.34, respectively. The C7F3 pigment coated porcelain fired at 1,250 ℃ had L* values of 39.91, 50.17, and 40.53 for the white ware, celadon body, and white mixed ware, respectively; with a* values of -1.07, -2.04, and -0.19, and at b* values of 0.46 and 6.01, it was found to be 4.03. As a new cobalt ferrite spinel phase was formed, it seemed to have had a great influence on the color change of the ceramic surface.

Pd-Au-Ag계 금속-도재용 합금의 탈가스 처리 후 급냉 처리가 모의소성과정에서 경도변화에 미치는 영향 (Effect of Ice-Quenching After Degassing on the Hardness Change During Simulated Porcelain Firing in a Metal-Ceramic Pd-Au-Ag Alloy)

  • 김성민;신혜정;권용훈;김형일;설효정
    • 대한치과재료학회지
    • /
    • 제43권4호
    • /
    • pp.317-322
    • /
    • 2016
  • The effect of ice-quenching after degassing on the hardness change during simulated porcelain firing in a metal-ceramic Pd-Au-Ag alloy was investigated by means of hardness test, field emission scanning electron microscopic observations, and X-ray diffraction analysis. The hardness decreased by ice-quenching after degassing, which was induced by the homogenization of the ice-quenched specimen. The decreased hardness by ice-quenching after degassing was recovered from the 1st opaque stage which was the first stage of the remaining firing process for bonding porcelain. The microstructural change showed that the increase in hardness during the remaining firing process was caused by precipitation. The ice-quenching after degassing did not affect the hardness change during the subsequent porcelain firing process.

송전용 자기애자의 열충격 특성 연구 (Study on Thermal Stress of Porcelain Insulator for T/L)

  • 한세원;조한구;최인혁;이동일
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.208-209
    • /
    • 2006
  • This study presents the thermal stress characteristics of TL porcelain insulators(healthy and ageing) by the accelerating thermal mechanical ageing test with forced temperature gradient. The test temperature gradient is $95^{\circ}C(-35{\sim}60^{\circ}C)$, it was focused to high temperature thermal stress as compared with IEC 60575 standard. There was no a discrimination in the case of healthy aluminous porcelain insulators, dissimilarly in crystoballite insulators according to this test method. It was indicated that the long tenn reliability by thermal stress was conformed reasonably through the conventional accelerating ageing test methods.

  • PDF

A comparative study on the bond strength of porcelain to the millingable Pd-Ag alloy

  • Hong, Jun-Tae;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권5호
    • /
    • pp.372-378
    • /
    • 2014
  • PURPOSE. The porcelain fused to gold has been widely used as a restoration both with the natural esthetics of the porcelain and durability and marginal fit of metal casting. However, recently, due to the continuous rise in the price of gold, an interest towards materials to replace gold alloy is getting higher. This study compared the bond strength of porcelain to millingable palladium-silver (Pd-Ag) alloy, with that of 3 conventionally used metal-ceramic alloys. MATERIALS AND METHODS. Four types of metal-ceramic alloys, castable nonprecious nickel-chrome alloy, castable precious metal alloys containing 83% and 32% of gold, and millingable Pd-Ag alloy were used to make metal specimens (n=40). And porcelain was applied on the center area of metal specimen. Three-point bending test was performed with universal testing machine. The bond strength data were analyzed with a one-way ANOVA and post hoc Scheffe's tests (${\alpha}=.05$). RESULTS. The 3-point bending test showed the strongest ($40.42{\pm}5.72$ MPa) metal-ceramic bond in the nonprecious Ni-Cr alloy, followed by millingable Pd-Ag alloy ($37.71{\pm}2.46$ MPa), precious metal alloy containing 83% of gold ($35.89{\pm}1.93$ MPa), and precious metal alloy containing 32% of gold ($34.59{\pm}2.63$ MPa). Nonprecious Ni-Cr alloy and precious metal alloy containing 32% of gold showed significant difference (P<.05). CONCLUSION. The type of metal-ceramic alloys affects the bond strength of porcelain. Every metal-ceramic alloy used in this study showed clinically applicable bond strength with porcelain (25 MPa).

금속 소부 도재관의 경우 인접면에서 접촉점의 위치가 도재 파절에 미치는 영향에 관한 연구 (A Study on effect that position of contact area at adjacent side has on fractures of porcelains in case of porcelain fused to metal crown)

  • 김용원
    • 대한치과기공학회지
    • /
    • 제29권2호
    • /
    • pp.173-180
    • /
    • 2007
  • There was a great problem about the deposition between materials of a different kind at the beginnings of the introduction of porcelains, however, thereafter the deposition efficiency was settlded to the sufficient level of all user thanks to effort to have studied by many scholars and clinical authorities. But in a clinical process, as the difference of designs has an effect on fractures of porcelains, this researcher divided them into 4 groups of A: 1 mm, B: 2 mm, C: 3 mm, and D: 4 mm, and made 40 pieces to each 10 as the test samples to consider a length axis of tooth for studies in accordance with a position of a finishing line to meet between porcelain and metal at the contact point at the adjacent side to a metal porcelain. The sample materials are those to be use at the open market and the test samples wer completed by the same manufacturing technique to that of existent metal porcelain tube. s a result of the strength test on fractures, the average value is as in the following, A: 1 mm - 8.5bar, B: 2 mm - 10.5bar, C: 3 mm - 14.3bar, and D: 4 mm - 15.0bar. In case of the metal porcelain tube, the more faraway to process parts of metal and porcelain from the contact point of adjacent side has the stronger strength of fractures, Accordingly, the research shows that it had better to keep off more than 3 to consider a ledngth axis of tooth.

  • PDF

ANSYS를 이용한 송전용 자기재 애자의 장력에 따른 특성 변화 (A Variation of Maximum Stress with Axial Loading in Porcelain Insulators for Transmission Line using ANSYS)

  • 우병철;한세원;조한구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마연구회
    • /
    • pp.104-107
    • /
    • 2003
  • The ageing cause in many porcelain suspension insulators which occur on transmission and distribution line with dead-end stings is mechanical stress in interface between porcelain and cement materials. It is known that the principal mechanical stress which give electrical failure is the results of the displacement is due to cement growth. We studied an analysing method to find out a deformation of brittle porcelain with a thermal expansion of cement for suspension insulator. These simulation analysis and experimental results show that cement volume growths affect severely to be mechanical failure ageing. These simulation analysis and experimental results show that axial loading affects of Porcelain insulators severely to be mechanical failure ageing.

  • PDF

치과용 타타늄-세라믹 수복시스템의 결합강도 향상을 위한 표면 코팅 (Surface Coatings to Enhance Bonding Strength of Dental Titanium-Ceramic Restorative System)

  • 이해형
    • 한국세라믹학회지
    • /
    • 제45권10호
    • /
    • pp.600-604
    • /
    • 2008
  • Although titanium-ceramic systems have gained substantial interests in dental prosthetic field, bonding problem between porcelain and titanium has not been solved. Main obstacle in titanium-porcelain bonding is excessive oxidation of titanium during porcelain firing. The effects of several coating materials on the bonding strength of titanium-porcelain system were investigated in this study. RF sputtering and electroplating of platinum significantly increased the bonding strength of porcelain-titanium specimen. However, coatings of Ni-Au, Ir, and ceramics(zirconia and hydroxyapatite) did not showed a significant effect on bonding strength. Platinum might be a promising material for the protective layer of excessive oxidation of titanium during porcelain firing, resulting in increase in the bonding strength.

글레이징처리한 도재와 연마한 도재의 표면조도에 관한 연구 (A STUDY ON THE SURFACE ROUGHNESS OF GLAZED PORCELAIN AND POLISHED PORCELAIN)

  • 최미라;정헌영;이선형;양재호
    • 대한치과보철학회지
    • /
    • 제36권4호
    • /
    • pp.549-565
    • /
    • 1998
  • Porcelain is considered to be one of the materials of choice for restoration where esthetics is of concern. But porcelain surface without final glazing treatment may induce undesirable results such as inflammatory response on adjacent soft tissues due to plaque accumulation and increased wear of opposing teeth. Therefore, rough porcelain surface must be smoothened by final glazing treatment or chairside polishing procedure. The purpose of this study was to compare the surface roughness among self-glazed, overglazed and polished porcelain with various polishing kit, and to detect which phase of polishing is optimal in clinic. Specimens were fabricated with Vita VMK porcelain. The surface treatment of each group was performed as follows. Group 1 : overglazing treatment Group 2 : self-glazing treatment Group 3 : polishing with the Truluster Polishing System for Porcelain(Brasseler, U.S.A.) Group 4 : polishing with the Exa Cerapol Adjustment kit (Edenta dental products, Switzerland) followed by finishing with diamond-filled polishing paste Group 5 : polishing with the Shofu Porcelain Adjustment kit (Shofu inc., Japan) followed by finishing with diamond-filled polishing paste. At each polishing steps, the measurement of Ra and Rq values were performed, and the surface was examined by scanning electron microscope. The results were as follows : 1. Overglazing treatment brought smoother surface than self-glazing treatment. 2. Polishing systems without porcelain polishing paste did not make better result than self-glazing treatment. 3. Polishing system with porcelain polishing paste made similar result to overglazing treatment. 4. Applying diamond-filled polishing paste after using polishing system which has no porcelain polishing paste produced surface as smooth as overglazing treatment does.

  • PDF

도재소부용 고금함유금합금의 연구 - 도재 결합층을 중심으로 - (A Study on Metal-Porcelain Fusing Layer in Porcelain Fused to High Gold Alloy)

  • 이기대;곽동주
    • 대한치과기공학회지
    • /
    • 제31권3호
    • /
    • pp.15-20
    • /
    • 2009
  • The success of the porcelain fused to gold alloy restoration depends not only on the choice of materials but to a larger degree on the technical skills. The porcelain fused to metal(PFM) alloys containing gold are commonly use for dental purposes in dental laboratory. The gold-colored alloys contain primarily gold, platinum, palladium, and silver, with minimum amounts of such metals as tin, iridium, or titanium. The purpose of this study is on the metal-porcelain fusing layer in porcelain fused to high gold alloy Principal results are as follows. The hardness number(Hv) of PFG is respectively $140.2{\pm}12.6$ in as-casted, $164.3{\pm}14.3$ in heat-treated, $186.6{\pm}20.4$ in fired-treated. The formation of the fusing(intermediate) layer caused by components fusing the interface of porcelain and gold alloy. The main components of the fusing(intermediate) layer are Na, Al, Si, K, Zn, Zr and Ce. The intermediate layer formed by the 2nd firing is more larger than the intermediate layer formed by the 1st firing.

  • PDF

도재파절 양상에 따른 수종의 도재 수복용 레진의 결합력에 관한 실험적 연구 (A comparison of the shear bond strength between porcelain repair systems and fractured surface of porcelain-fused-to-metal restorations)

  • 최정원;한동후;정창모
    • 대한치과보철학회지
    • /
    • 제28권2호
    • /
    • pp.147-163
    • /
    • 1990
  • Although dental porcelain demonstrates lasting esthetic results, it suffers from inherent brittle fractures. Various techniques and materials for intraoral porcelain repair has been suggested. This study investigated the in vitro shear strength of three porcelain repair systems according to aspects of the porcelain fractures. The purpose of this study was to evaluate the shear bond strength of three porcelain repair systems(All-bond, Clearfil, Scotchprime) according to fractured surface of porcelain - fused - to - metal restorations. For this study specimens were divided into five groups : group 1 represented fracture occurred at body porcelain layer, group 2 represented fracture occurred at opaque porcelain layer, group 3 represented fracture including 1/3 of metal exposure, group 4 represented fracture including 2/3 of metal exposure, and group 5 represented all metal surface was exposed. Specimens were stored in double deionized water(24Hr, $37^{\circ}C$) and thermocycling was performed(24Hr, 1080cycles), and subjected to a shear force parallel to the repair resin and porcelain interface by use of an University Testing Machine. The results of this study were obtained as follows : 1. In group 1 and 2, bond strength was relatively high, and bond strength showing reducing tendency as exposure of metal was increased. 2. In group 1, bond strength was relatively high, and no significant differences in porcelain repair system. 3. In group 2, 3 and 4, All-bond and Clearfil provided significantly higher bond strength than scotchprime. 4. In group 5, bond strength was the lowest among all groups and especially in case if Scotchprime. 5. Cohesive failure was observed in group 1 and 2, adhesive failure was observed in group 5, and cohesive / adhesive failures were observed in group 3 and 4.

  • PDF