• 제목/요약/키워드: Porcelain bond strength

검색결과 148건 처리시간 0.02초

지르코니아 코핑과 전장도재 간의 전단결합강도와 파절양상 비교 (A comparative study of the shear bond strength and failure mode between zirconia copings and veneering ceramics)

  • 김원영;전병욱;정인성
    • 대한치과기공학회지
    • /
    • 제37권4호
    • /
    • pp.243-250
    • /
    • 2015
  • Purpose: The aim of this study was to investigate the shear bond strength between various commercial zirconia coping and veneering ceramic, and to observe the failure mode. Methods: For each zirconia block (iJAM Emerald, LUXEN Smile block, ICE Zirkon transluzent), 10 rectangular specimens were layered with Cercon ceram kiss, IPS e.max ceram, ICE Zirkon ceramic according to recommended by the manufacturer. The shear bond strength tests of the veneering porcelain to zirconia were carried out until fracture by a universal testing machine. After the shear bond tests, failure modes were characterized visually, under a stereomicroscope, such as adhesive, cohesive, or mixed. Data were analyzed with One-way ANOVA followed by Scheffe's tests. Results: The shear bond strength ($mean{\pm}SD$) of zirconia-veneer ceramic were JC group $13.9{\pm}3.6MPa$; JE group $17.7{\pm}2.4MPa$; JI group $15.1{\pm}2.5MPa$; LC group $9.5{\pm}1.5MPa$; LE group $16.2{\pm}2.3MPa$; LI group $12.6{\pm}0.8MPa$; ZC group $16.0{\pm}2.3MPa$; ZE group $18.5{\pm}3.4MPa$; and ZI group $15.3{\pm}3.2MPa$. The One-way ANOVA showed a significant difference between groups (p<0.05). The failure mode in most experimental groups was mixed failure, except for the LC group, which showed adhesive failure, and JE group, LE group and ZE group showed cohesive failure. Conclusion: For IPS e.max ceram, the shear bond strength value was highest for all kinds of zirconia blocks. For ICE Zirkon transluzent, the shear bond strength value was highest for all kinds of veneering ceramics. Most of experimental group interfaces revealed mixed failure mode.

도재소부전장관(陶材燒付前奬冠) 파절수리시(破折修理時) 표면처리(表面處理) 방법(方法)에 따른 수복(修復)레진의 유지력(維持力)에 관(關)한 연구(硏究) (COMPARISON OF RETENTIVE FORCE OF REPAIR RESIN BY VARIOUS SURFACE TREATMENT METHODS IN THE REPAIR OF FRACTURED PORCELAIN FUSED TO METAL CROWN)

  • 임헌송;허성주;조인호
    • 대한치과보철학회지
    • /
    • 제30권1호
    • /
    • pp.73-83
    • /
    • 1992
  • Now composite resin restoration is clinically accepted in the repair of fractured PFM case, many mechanical surface treatment methods are performed to increase retentive force. The main purpose of this study was to compare the retentive force among the possible surface treatments and to insure the best method for the clinical application to the fractures porecelain and the exposed metal surface. To compare and to analyze the retentive force of repair resin, porcelain specimen were divided into 2 groups, etching group and non-etching group, and etching group were treated with 37% $H_3PO_4$, 1.23% APF, 10% HF and non-etching groups were treated with diamond bur, micro-sandblasasting. Also, metal specimens were divided by 2 groups : one was non-precious metal group which was treated with diamond bur, micro-sandblasting and tin plating and electrolytic etching, the other was precious metal group which was composed of micro-sandblasting treatment only and tin plating treatment with micro-sandblasting. Each specimen had been restored for 48 hours and the bond strength of each specimen was calculated with Universal testing machine. The results were as follows : 1. Porcelain specimen had higher bonding strength than metal specimen for the repair resin(P<0.01). 2. In porcelain specimen, 10% HF etching group had the highest bonding strength among etching and non-etching group. 3. Metal specimen treated with micro-sandblasting had highest bonding strength among the non-sandblasting had hightest bonding strength among the non-precious group, tin plating group had higher bonding strength than micro-sandblasting group between the precious metal groups. 4. Bonding strength of tin plating was increased in precious metal group only.

  • PDF

도재소부용 비귀금속 합금의 표면처리가 금속과 도재간의 전단결합강도에 미치는 영향 (EFFECT OF SURFACE TREATMENT OF NONPRECIOUS METAL FOR PORCELAIN IN THE SHEAR BOND STRENDTH BETWEEN METAL AND PORCELAIN)

  • 이청희;조성암
    • 대한치과보철학회지
    • /
    • 제34권3호
    • /
    • pp.533-538
    • /
    • 1996
  • 도재 소부용 비귀금속합금의 표면처리가 금속과 도재간의 전단결합강도에 어떠한 영향을 미치는지 알아보기 위하여, 비귀금속 합금의 표면에 어떠한 처리도 하지 않는 대조군과 샌드브라스팅한 실험군, 스퍼트 에칭한 실험군, 그리고 샌드브라스팅후 스퍼트 에칭한 실험군으로 나눈 후에 각각의 시편에 통상적인 방법으로 도재를 소성한 후 인스트론 만능 시험기를 사용하여 전단결합강도를 측정하여 다음과 같은 결론을 얻었다. 1. 샌드브라스팅후 스퍼트 에칭한 실험군과 샌드브라스팅한 군은 대조군에 대해 높은 값을 나타내었다(P<0.05). 2. 스퍼트 에칭한 실험군은 대조군에 대해 차이가 없었다(P>0.05).

  • PDF

세라믹 브라켓 부착 시 레이저를 이용한 포세린 표면처리 효과 (The effect of using laser for ceramic bracket bonding of porcelain surfaces)

  • 안경미;손동석
    • 대한치과교정학회지
    • /
    • 제38권4호
    • /
    • pp.275-282
    • /
    • 2008
  • 본 연구는 포세린 표면에 $CO_2$ 레이저를 조사하여 세라믹 브라켓을 부착 후 전단결합강도를 측정하고, 산부식처리 및 샌드블라스트 등의 일반적인 방법을 시행하여 그 결과를 비교 분석하여 레이저 표면처리의 효과를 연구하고자 시행되었다. 90개의 포세린($8\;{\times}\;8\;{\times}\;4\;mm$) 시편을 제작하여 각각 10개씩 9개군으로 나누었다. 대조군(C)으로 아무런 표면처리를 하지 않은 글레이즈 표면을 사용하였으며, 실험군은 인산 처리군(OFA), 인산과 silane 처리군(OFA + S), 샌드블라스팅 처리군(SB), 샌드블라스팅과 silane 처리군(SB + S), 레이저 처리군(L), 레이저와 silane 처리군(L + S), 불산 처리군(HFA), 불산과 silane 처리군(HFA + S)으로 분류하였다. 만능시험기를 이용하여 전단결합강도를 측정하고 그 파절양상을 비교 분석한 결과 불산과 silane을 동시에 처리한 군에서 가장 높은 값($13.92\;{\pm}\;1.92\;MPa$)을 보였으며, 측정값은 SB + S ($10.16\;{\pm}\;1.27\;MPa$), HFA (10.09\;{\pm}\;1.07\;MPa$), L + S ($8.25\;{\pm}\;1.24\;MPa$), L ($7.86\;{\pm}\;0.96\;MPa$), OFA + S ($7.22\;{\pm}\;1.09\;MPa$), SB ($3.41\;{\pm}\;0.37\;MPa$), OFA ($2.81\;{\pm}\;0.37\;MPa$), 대조군($2.46\;{\pm}\;1.36\;MPa$) 순이었다. 브라켓 부착 시 치과용 레이저를 이용한 포세린의 표면처리 결과 전단결합강도의 값은 임상적으로 받아들여질 만한 수치를 보였으며 레이저와 silane을 동시에 처리한 군과는 통계적으로 유의할 만한 차이를 보이지 않았다(p > 0.05). 이상의 연구결과는 포세린 표면에 세라믹 브라켓 부착 시 2-watt의 $CO_2$ 레이저를 사용하여 전처리를 하는 방법은 시간절약의 관점에서 임상적으로 표면 전처리의 적절한 치료 대안이 될 수 있음을 보여주었다.

상아질 지각완화제가 레진시멘트의 전단결합강도에 미치는 영향 (EFFECT OF DENTIN DESENSITIZERS ON SHEAR BOND STRENGTH OF RESIN CEMENTS)

  • 이호;진태호;손외수;안희영
    • 대한치과보철학회지
    • /
    • 제40권4호
    • /
    • pp.365-373
    • /
    • 2002
  • The purpose of this study was to investigate the effects of desensitizer on shear bond strength of adhesive resin cements for all ceramic crown. For this study, Gluma $desensitizer^{(R)}$(Heraeus Kulzer, Germany) and MS $Coat^{(R)}$(Sun medical, Japan) were used as desensitizer, and Bistite $II^{(R)}$ resin cement(Tokuyama, Japan) and Variolink $II^{(R)}$ resin cement (Ivoclar, Liechtenstein) were used. IPS Empress ceramics were bonded to dentin surfaces after application of desensitizer and shear bond strength of specimens were measured using UTM(Zwick 1456 41. Zwick, Germany) at a crosshead speed of 1mm/min. The obtained results were as follows : 1. The shear bond strength of both resin cements were not affected by Gluma $desensitizer^{(R)}$ containing HEMA 2. The shear bond strength of Bistite $II^{(R)}$ resin cement was significantly decreased by MS $Coat^{(R)}$. 3. The failure mode in MS $Coat^{(R)}-Bistite \;II^{(R)}$ group was mainly adhesive type between dentin and resin cement. but that of Gluma $desensitizer^{(R)}$-Variolink $II^{(R)}$ group was mainly mixed type, combined adhesive failures between dentin and resin cement or porcelain and resin cement.

Rocatec system이 Zir-ceram과 간접복합수지간의 전단결합강도에 미치는 영향 (Effect of Rocatec system on Shear Bond Strength between Zir-Ceram and Sinfony Indirect Composite Resin)

  • 김동일;김부섭;정인성
    • 대한치과기공학회지
    • /
    • 제30권2호
    • /
    • pp.23-29
    • /
    • 2008
  • The purpose of this study is to evaluate possibility of using indirect composite resin instead of porcelain through the measurement of shear bond strength between zirconia core and indirect composite resin under treatment of $Rocatec^{TM}$ system for improving the adhesion of indirect composite resin. 20 cylindrical zirconia core specimens were divided into 2 groups, according to zirconia surface treatment and attached materials: 1) treated with sandblast and attached with indirect composite resin, 2) treated with sandblast + $Rocatec^{TM}$ system and attached with indirect composite resin. The shear bond strength of each experimental group was measured by MTS and the changes of zirconia core surface according to surface treatments were obtained by SEM observation and measurements of surface roughness. The mean shear bond strength values are $0.55\;{\pm}\;0.11MPa$(Group SC) and $1.16\;{\pm}\;0.46MPa$(Group SRC). The mean Ra values for the surface treatments were follows: $0.39\;{\pm}\;0.13$($100{\beta}_{{\mu}m}$ sandblast) and $0.50\;{\pm}\;0.03$($100{\beta}_{{\mu}m}$ sandblast + $Rocatec^{TM}$ system). In the analysis of EDS, Si element was detected in the Group SC. The shear bond strength between zirconia core and indirect composite resin was improved significantly by using $Rocatec^{TM}$ system.

  • PDF

합착용 복합레진시멘트로 합착한 Machinable Ceramic과 상아질 사이의 인장강도에 대한 실험적 연구 (TENSILE STREGNTH BETWEEN MACHINABLE CERAMIC AND DENTIN CEMENTED WITH LUTING COMPOSITE RESIN CEMENTS)

  • 조병훈
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.487-501
    • /
    • 1998
  • In the case of CAD/CAM ceramic inlay restorations, if isthmus width is widened too much, it may cause fracture of remaining tooth structure or loss of bonding at the luting interface because of excessive displacement of buccal or lingual cusps under occlusal loads. So to clarify the criterior of widening isthmus width, this study was designed to test the tensile bond strength and bond failure mode between dentin and ceramic cemented with luting composite resin cements. Cylindrical ceramic blocks(Vita Cerec Mark II, d=4mm) were bonded to buccal dentin of 40 freshly extracted third molars with 4 luting composite resin cements(group1 : Scotchbond Resin Cement/Scotchbond Multi-Purpose, group2 : Duolink Resin Cement/ All-Bond 2, group3: Bistite Resin Cement/Ceramics Primer, and group4:Superbond C&B). Tensile bond test was done under universal testing machine using bonding and measuring alignment blocks(${\phi}ilo$ & Urn, 1992). After immersion of fractured samples into 1 % methylene blue for 24 hours, failure mode was analysed under stereomicroscope and SEM. Results: The tensile bond strength of goup 1, 2 & 4 was $13.97{\pm}2.90$ MPa, $16.49{\pm}3.90$ MPa and $16.l7{\pm}4.32$ MPa, respectively. There was no statistical differences(p>0.05). But, group 3 showed significantly lower bond stregnth($5.98{\pm}1.l7$ MPa, p<0.05). In almost all samples, adhesive fractures between dentin and resin cements were observed. But, in group 1, 2 & 4, as bond strength increased, cohesive fracture within resin cement was observed simultaneously. And, in group 3, as bond strength decreased, cohesive fracture between hybrid layer and composite resin cement was also observed. Cohesive fracture within dentin and porcelain adhesive fracture were not observed. In conclusion, although adhesive cements were used in CAD/CAM -fabricated ceramic inlay restorations, the conservative priciples of cavity preparation must be obligated.

  • PDF

Effect of metal conditioner on bonding of porcelain to cobalt-chromium alloy

  • Minesaki, Yoshito;Murahara, Sadaaki;Kajihara, Yutaro;Takenouchi, Yoshihisa;Tanaka, Takuo;Suzuki, Shiro;Minami, Hiroyuki
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권1호
    • /
    • pp.1-8
    • /
    • 2016
  • PURPOSE. The purpose of this study was to evaluate the efficacy of two different metal conditioners for non-precious metal alloys for the bonding of porcelain to a cobalt-chromium (Co-Cr) alloy. MATERIALS AND METHODS. Disk-shaped specimens ($2.5{\times}10.0mm$) were cast with Co-Cr alloy and used as adherend materials. The bonding surfaces were polished with a 600-grid silicon carbide paper and airborne-particle abraded using $110{\mu}m$ alumina particles. Bonding specimens were fabricated by applying and firing either of the metal conditioners on the airborne-particle abraded surface, followed by firing porcelain into 5 mm in diameter and 3 mm in height. Specimens without metal conditioner were also fabricated. Shear bond strength for each group (n=8) were measured and compared (${\alpha}=.05$). Sectional view of bonding interface was observed by SEM. EDS analysis was performed to determine the chemical elements of metal conditioners and to determine the failure modes after shear test. RESULTS. There were significant differences among three groups, and two metal conditioner-applied groups showed significantly higher values compared to the non-metal conditioner group. The SEM observation of the sectional view at bonding interface revealed loose contact at porcelain-alloy surface for non-metal conditioner group, however, close contact at both alloy-metal conditioner and metal conditioner-porcelain interfaces for both metal conditioner-applied groups. All the specimens showed mixed failures. EDS analysis showed that one metal conditioner was Si-based material, and another was Ti-based material. Si-based metal conditioner showed higher bond strengths compared to the Ti-based metal conditioner, but exhibited more porous failure surface failure. CONCLUSION. Based on the results of this study, it can be stated that the application of metal conditioner is recommended for the bonding of porcelain to cobalt-chromium alloys.

실라노 펜의 적용이 장석계 도재 및 지르코니아와 레진의 전단결합강도에 미치는 영향 (The effect of Silano-pen on the shear bond strength of resin to feldspathic porcelain and zirconia)

  • 신명식;이정열;김민수;신상완
    • 대한치과보철학회지
    • /
    • 제52권1호
    • /
    • pp.1-8
    • /
    • 2014
  • 연구 목적: 본 연구의 목적은 장석형 도재와 지르코니아에 Silano-pen의 적용이 복합레진과의 전단결합강도에 미치는 영향을 알아보고자 하는 것이다. 연구 재료 및 방법: 장석형 도재와 지르코니아를 지름 12 mm, 두께 2 mm 크기로 각각 30개씩 제작하여 표면을 고르고 평활하게 한 후 아크릴 레진에 포매 하였다. 각각 Group F와 Group Z로 나눈 후, (1) Group F1과 Z1은 불산 에칭과 실레인, (2) Group F2와 Z2는 Silano-pen과 실레인, (3) Group F3와 Z3는 불산 에칭과 Silano-pen, 실레인을 적용시켰다. 표면 처리 후, 각각의 시편의 표면을 주사전자현미경으로 관찰하였다. 높이 2 mm, 직경 3 mm의 복합레진을 붙여 광중합 하고 만능시험기를 이용하여 세라믹과 복합레진간의 전단결합강도를 측정하였다. 측정값을 Two way ANOVA와 Tukey's multiple comparison test을 사용하여 통계 분석 하였다(${\alpha}=.05$). 결과: 주사전자현미경의 관찰에서 Group F2와 F3에서 가장 거친 표면을 볼 수 있었으며, Group Z3에서 실리카 입자의 분포밀도가 가장 높았다. 장석형 도재에서는 전단결합강도 측정 결과 Group F3가 가장 높게 측정되었고 Group F1이 가장 낮게 측정되었지만, Group간에 통계학적 유의성은 없었다. 지르코니아에서는 Group Z3가 가장 높게 측정되었고 Group Z1이 가장 낮게 측정되었으며, Group간에 모두 통계학적 유의성이 있었다. 결론: 지르코니아에서는 불산 에칭의 적용 후 Silano-pen과 실레인의 적용이 복합레진 접착에 효과적이다.

도재전장관용 비귀금속합금과 도재의 융착결합에 관한 연구 (A Study on Bond Strength of Procelain with Non Precious Alloy)

  • 강성현
    • 대한치과보철학회지
    • /
    • 제18권1호
    • /
    • pp.49-57
    • /
    • 1980
  • The adhesive mechanisms on the metal-ceramic restorations have been reported to be mechanical interlocking, chemical bonding, compressive force, and Van der Waal's force, etc. Of these, the mechanical interlocking and chemical bonding forces are thought to affect the adhesive force between Ni-Cr alloy and porcelain. This study investigates the adhesion of Ni-Cr alloy to porcelain according to surface treatment. For this purpose, the following experiments were made; The compositions of Ni-Cr alloy as cast by emission spectrograph, and the oxides produced on Ni-Cr alloy during degassing at $1850^{\circ}F$ for 30 minutes in air and in vacuum were analyzed by X-ray diffractograph. The metal phases of Ni-Cr alloy were observed according to porcelain-baking cyclic heat treatment by photo microscope and the distribution and the shift of elements of Ni-Cr alloy and porcelain and the failure phases between Ni-Cr alloy and porcelain by scanning electron microscope. The adhesive force between Ni-Cr alloy and porcelain was measured according to surface treatment with oxidization and roughening by Instron Universal Testing Machine. Results were as follows; 1. The metal phases of Ni-Cr alloy as cast and degassing state showed the enlarged and fused core, but when subjected to porcelain-baking cyclic heat treatment, showed a dendrite growing. 2. The kinds of metal oxides produced on Ni-Cr alloy during degassing were found to be NiO and $Cr_2O_3$. 3. The distribution of elements at the interface of Ni-Cr alloy and porcelain in degassing state showed demarcation line, but in roughening state, showed mechanical interlocking phase. 4. The shift of elements at the interface occurred in both states, but the shift amount was found to be larger in roughening than in degassing. 5. The adhesive force between Ni-Cr alloy and porcelain was found to be $3.45{\pm}0.93kg/mm^2$, in degassing and $3.82{\pm}0.99kg/mm^2$, in roughening. 6. The failure phase between Ni-Cr alloy and porcelain showed the mixed type failure.

  • PDF