• 제목/요약/키워드: Porcelain Insulator

검색결과 140건 처리시간 0.036초

표면방전을 이용한 자기제 현수애자의 표면특성 평가 (The Evaluation of Surface Characteristics by Using Surface Discharge Method for Porcelain Suspension in Insulators)

  • 송일근;김찬영;한용희;윤영숭;안규선;임장섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.199-202
    • /
    • 1999
  • The paper deals with the surface discharge characteristics for porcelain suspension insulators. The micro-crystals were crystallized on the surface of glace coated on the porcelain These micro-crystals may affect the electrical Properties such as flashover voltage. However. not much research have been conducted. In this study. we correlated the surface discharge characteristics to the microstructures. It was confirmed that the micro-crystals on the glaze initiated the flashover when the surface was wetted and/or contaminated.

  • PDF

배전용 현수애자의 특성분석 (Characteristic Analysis of Suspension Insulators for Distribution Line)

  • 김찬영;김주용;송일근;이병성
    • 한국전기전자재료학회논문지
    • /
    • 제13권3호
    • /
    • pp.259-264
    • /
    • 2000
  • The paper provides the characteristic analyses of porcelain suspension insulators. The comparisons of characteristics were made as a function of failed and unfailed insulators which had ben used in the fields. This paper also describes the failure modes occurred in the fields. The aging of cement corrosion of metal breaking of shed puncture in the head and separation of glaze are different failure modes for porcelain suspension insulators. Among these failure modes the puncture breaking and glaze problems were major concerns in this research. The cracks porosities of porcelain and micro-crystals on the graze were the causes of these failures. These results were confirmed by conducting various failure analyses.

  • PDF

폴리머 LP애자의 설계해석과 전기적 성능 시험 (The Design Analysis and Electrical Performance Test of Polymer LP Insulator)

  • 이운용;조한구;박상호;송홍준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.399-401
    • /
    • 2000
  • Recently polymer insulators are being used for outdoor high voltage applications. Polymer insulators for transmission and distribution line have significant advantages over porcelain and glass insulators, especially for ultra-high voltage(UHV) transmission lines. Their advantages are light weight, vandalism resistance and hydrophobicity. In this paper, polymer line post insulator has been designed and investigated electric field distribution by FEM. Designed LP insulators have been tested as insulator performance test, such as power frequency voltage test, lightning impulse voltage test, artificial pollution test and flexural load test.

  • PDF

도시철도 직류용 FRP 지지애자 및 장간애자 특성 분석

  • 강현일;이기승;김윤식;심재석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.152-152
    • /
    • 2009
  • Direct Current Fiber Reinforced Plastic (DC FRP) insulators were developed and their mechanical and electrical characteristics were investigated. Electrical tests were carried out to measure withstanding and flashover voltages under common use frequency condition. Tensile and bending tests were performed for the mechanical characteristics. The test results showed that DC FRP insulators had superior voltage resistances and strengths to porcelain insulators.

  • PDF

폴리머 현수애자의 복합가속열화 평가기술 (Multi-Stress Aging Test Technology for Suspension Polymer Insulator)

  • 박효열;강동필;김익수;신영준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.481-484
    • /
    • 2003
  • Recently polymer insulators are being used for outdoor high voltage applications. Polymer insulators have significant advantages over porcelain and glass insulators. With the gradual improvement of their design and material, their reliability has also increased. It is however difficult to establish how they will perform after several years of service. Aging of the insulator weathershed may lead to damages such as excessive chalking and crazing, erosion and tracking which affect the insulator performance. In service insulator are subjected to aging stresses such as humidity, pollution and electrical field which act singly or in combination. There have been numerous accelerated laboratory tests developed with the intention of evaluating suitability of polymeric materials. Some of these are strictly material tests, where as, others evaluate full scale devices. Service experience plays a key role in the utility selection of polymer insulator, but is time consuming, and may not always be available. Hence there is a need for a meaningful and reliable accelerated aging test for polymer insulator. This paper describes multi-stress aging test for reliability of polymer insulator This paper presents the rule of multi-stress aging test and test chamber for polymer insulator in korea electrotechnology research institute.

  • PDF

배전용 폴리머 현수애자의 설계해석 (The Design Analysis of Distribution Polymer Suspension Insulator)

  • 이운용;조한구;한동희;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.66-68
    • /
    • 2001
  • Recently polymer insulators are being used for outdoor high voltage applications. Polymer insulators for transmission and distribution line have significant advantages over porcelain and glass insulators, especially for ultra-high voltage(UHV) transmission lines. Their advantages are light weight, vandalism resistance and hydrophobicity. In this paper, distribution polymer suspension insulator has been designed and investigated electric field distribution by FEM.

  • PDF

Composite Insulator silicone shed 전계특성 (Characteristices for the Electric Field of Composite Insulator Silicone Shed)

  • 장윤기;최성만;정용수;이동원;김정배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.99-100
    • /
    • 2008
  • Composite insulators are rapidly replacing their porcelain counterparts in electrical substation applications. The composite insulator provide technical and safety ad vantages over other types of insulator. These insulators consist of a FRP(Fiber-reinforced polymer), with two metal flanges and silicone rubber. In this paper, we have investigated the influence of electric field different shaped silicone shed under $SF_6$ gas. As a result, shape of silicone rubber does not effected a electric field. However, the shape of shed can be decided the creepage distance.

  • PDF

Accelerating Aging of Transmission Line Porcelain Suspension Insulators by Autoclaving

  • Lee, Won-Kyo;Choi, In-Hyuk;Shin, Koo-Yong;Hwang, Kab-Cheol;Han, Se-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권4호
    • /
    • pp.147-150
    • /
    • 2008
  • Porcelain suspension insulators aged for 1, 5 and 10 years on Korean transmission lines and new insulators are tested for autoclave expansion. The compressive strength of the insulators aged in an autoclave with conditions of $250\;^{\circ}C$ and at 20 atm for 30 minutes, was about $7.6\;kgf/mm^2$, which is close to that measured on insulators aged for 10 years in the field. From simulation results, the cement displacement changed linearly with temperature. At a temperature of $200\;^{\circ}C$, the shear stress was approximately $7\;kgf/mm^2$; a stress that is brought about by a 0.07 % expansion of the cement. It is evident that the cement would fracture at a 0.07 % expansion, because the cement has about 7 to $9\;kgf/mm^2$ flexure strength. A turning point in the shear stress with mechanical load occurred at 0.02 % cement expansion. From an analysis of the porcelain body it is shown that there is sufficient margin of strength to guard against fracture of the porcelain body even for a cement expansion more than 0.12 %.

기계적 분석을 통한 송전용 자기 애자의 열화 판단 및 파손 부위에 대한 연구 (Determination of Deterioration and Damage of Porcelain Insulators in Power Transmission Line Through Mechanical Analysis)

  • 손주암;최인혁;구자빈;김태용;전성호;이윤정;이준신
    • 한국전기전자재료학회논문지
    • /
    • 제33권1호
    • /
    • pp.50-55
    • /
    • 2020
  • Porcelain insulators have been used for a long time in 154 kV power transmission lines. They are likely to be exposed to sudden failure because of product deterioration. This study was conducted to evaluate the quality of porcelain insulators. After stresses were applied, the damaged regions of aged insulators were investigated in terms of chemical composition, material structure, and other properties. For porcelain insulators that were in service for a long time, the mechanical failure load was 126 kN, whereas the average mechanical failure load was 167.3 kN for new products. It was also determined that corrosion occurred at the metal pin part due to the penetration of moisture into the gap between the pin and the ceramic. Statistical analyses of failure were performed to identify the portion of the insulators that were broken. Cristobalite porcelain insulators fabricated without alumina additives had a high failure rate of 54% for the porcelain component. In the case of the addition of Alumina (Al2O3) to the porcelain insulators to improve the strength of the ceramic component, a more frequent damage rate of the cap and pin of 73.3% and 27%, respectively, was observed. This study reports on the material component of SiO2 and the percentage of alumina added, with respect to the mechanical properties of porcelain insulators.

자기제 애자의 절연파괴 감소대책 연구 (A Study on the breakdown reduction of porcelain insulators)

  • 송일근;박구범;김영래;김경화;곽희로;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1042-1044
    • /
    • 1995
  • This paper provides the results and analyses of investigations into porcelain suspension insulators failures on the KEPCO system. The high failure rate of suspension insulators on distribution lines has been attributed to the volume expansion of the cement, the insulation puncture breakdown of the porcelain and the power arc failure. The utility must use only the good insulators and at least reduce the insulator failure rate. So, this paper recommends that the utility make test criteria(cement expansion test, steep front-of-wave flashover voltage test and power arc test. etc) on the suspension insulators.

  • PDF