• 제목/요약/키워드: Porcelain Insulator

검색결과 140건 처리시간 0.025초

옥외용 절연체 표면에서의 ESDD 측정과 내오손특성에 관한 연구 (A Study on Measurement of ESDD and Contamination Performance of Polymeric Outdoor Insulators)

  • 연복희;유형철;이현진;송정용;이태호;허창수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.427-430
    • /
    • 2002
  • This paper presents on contamination performance of polymeric outdoor insulator with different contaminant accumulation. The ESDD (equivalent salt deposit density), tracking resistance and clean-fog test were performed to investigate the characteristics of contamination performance on polymeric outdoor insulator. Furthermore, we evaluated together with the porcelain samples for its comparison. It is found that ESDD of polymeric and porcelain insulator depends on the installation position. This surface accumulation of contaminant lead to the loss of surface hydrophobicity, expecially upper shed part of polymeric insulator. In addition, the effect of an artificial contaminant on the tracking resistance by inclined-plane method and leakage suppression ability under clean fog was surveyed. The time of tracking failure did not appear to change significantly with a much contaminant accumulation, while leakage current under clean-fog increased.

  • PDF

기후 변화에 따른 자기 애자의 시멘트 경도 변화 (Hardness Profiles of Porcelain Insulators by Climate Changes)

  • 이주현;김홍식;김준동;최인혁
    • 한국전기전자재료학회논문지
    • /
    • 제31권1호
    • /
    • pp.24-28
    • /
    • 2018
  • Insulators used in overhead transmission lines are continuously exposed to a number of mechanical and electrical stresses owing to external environmental factors, resulting in corrosion, reduction in durability, and deterioration. Widely used porcelain insulators are fabricated with cement and porcelain and are especially common in Korea. Changes in the hardness and chemical reactivity of the cement increase the leakage and fault currents and increase the possibility of flashover due to insulation breakdown. Therefore, it is important to evaluate the durability and defects of porcelain insulators. Studies on the reliability of various evaluation methods are needed to prevent accidents by accurately determining the replacement timing and potential defects in porcelain insulators. In this study, the hardness of the cement part of the porcelain insulator was measured using the Vickers hardness test and its composition was analyzed by energy dispersive spectroscopy and X-ray diffraction analysis. The performance of the insulators was compared in two different regions with varying climatic conditions. This study presents an evaluation method of the defects in porcelain insulators by measuring humidity, which can also be used to assess the reliability of the insulators.

코로나 방전에 의한 자기 및 폴리머 애자의 자외선 발생특성 (The Ultraviolet Generation Characteristics of porcelain and Polymer Insulators by Corona Discharge)

  • 송길목;방선배;김종민;김영석
    • 조명전기설비학회논문지
    • /
    • 제22권4호
    • /
    • pp.147-152
    • /
    • 2008
  • 본 논문은 코로나 방전에 의한 자기애자와 폴리머애자의 자외선 발생 특성에 관한 것이다. 자외선 카메라를 이용하여 측정하고, KS C IEC 60060-1(2006)의 전압조건을 준수하여 실험하였다. 결과로서 자기애자에서의 코로나 방전은 애자 접합면에서 가장 취약한 부분에서 시작되었다. 폴리머애자는 취약한 접합면에서 자외선이 발생하였으며, 전원 측에서 나타났다. 이로써 자외선 검출을 통해 절연애자의 취약부분이 쉽게 확인되는 것을 알 수 있었다. 또한, 기존의 초음파 검출기술과 비교하여 열화단계가 정량화될 수 있음을 확인하였다. 이는 신뢰성 있는 데이터를 통해 전력설비의 열화를 판단하는 기준에 활용될 수 있다. 향후 현장진단에 적합한 기술로서 앞으로 많은 연구가 기대된다.

Characteristics of a Corona between a Wiring Clamp (Dead End Clamp) and a Porcelain Insulator Used in a 154kV Power Receptacle

  • Han, Woon-Ki
    • International Journal of Safety
    • /
    • 제7권1호
    • /
    • pp.21-25
    • /
    • 2008
  • The occurrence of a corona is that electrical discharge due to the heterogeneity that occurs when an electrical field is concentrated in an electrode due to a cusp formed on said electrode. Wire treatment at the end of a 154kV dead end clamp for end users accelerates the occurrence of corona, which in turn leads to power loss and noise. In this study, the characteristics of the corona which occurs between porcelain insulators and support clamps of overhead lines used in l54kV power receiving facilities for end users were investigated. The corona, which cannot be identified by one common method, was measured utilizing a UV image camera. A risk assessment for fire damage and its status was suggested. The stress distribution of the electrical field by length of bare wire was suggested by means of the finite element method (FEMLAB). As a result, it was found to affect a porcelain insulators. These results can be utilized for the enhancement of clamp installation and safety in power facilities.

송전용 자기애자의 열충격 특성 연구 (Study on Thermal Stress of Porcelain Insulator for T/L)

  • 한세원;조한구;최인혁;이동일
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.208-209
    • /
    • 2006
  • This study presents the thermal stress characteristics of TL porcelain insulators(healthy and ageing) by the accelerating thermal mechanical ageing test with forced temperature gradient. The test temperature gradient is $95^{\circ}C(-35{\sim}60^{\circ}C)$, it was focused to high temperature thermal stress as compared with IEC 60575 standard. There was no a discrimination in the case of healthy aluminous porcelain insulators, dissimilarly in crystoballite insulators according to this test method. It was indicated that the long tenn reliability by thermal stress was conformed reasonably through the conventional accelerating ageing test methods.

  • PDF

송전용 자기재 현수애자의 고강도 특성 연구 (A Study on the High Strength of porcelain insulators for transmission line)

  • 조한구;한세원;박기호;최연규;이동일;최인혁;김태영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마연구회
    • /
    • pp.85-88
    • /
    • 2003
  • In this study, porcelain insulator samples which have a different alumina composition were manufactured in order to test electrical and mechanical properties and make an analysis of the propagation phenomena of micro cracks on porcelain body. From XRD quantitative analysis the crystalline phases were different with alumina composition, sample C and D which have about 17wt% Corundum phase without the Cristobalite phase shows better electrical and mechanical properties than sample A and 8 which have the Cristobalite phase. In dielectrics test on porcelain samples with below 17wt% alumina composition, it was found that the amount of glass phase$(SiO_2)$have an main effect to decrease the dielectric loss$(tan{\delta})$, and the dielectric breakdown voltage of aluminous porcelain insulators was largely affected by its relative density. As a micro cracks analysis, HRS were measured, then the intensity of HRS increased with the amount of alumina composition. On the other hand, the propagation behaviors of cracks was fairly influenced by the distribution of pores.

  • PDF

알루미나 조성에 따른 고강도 자기 애자의 특성 연구 (Study on Characteristics of Porcelain Insulators for High Strength with Alumina Composition)

  • 조한구;한세원;박기호;최연규
    • 한국전기전자재료학회논문지
    • /
    • 제17권3호
    • /
    • pp.353-359
    • /
    • 2004
  • In this study. porcelain insulator samples which have a different alumina composition were manufactured in order to test electrical and mechanical properties and make an analysis of the propagation phenomena of micro cracks on porcelain body. From XRD quantitative analysis the crystalline phases were different with alumina composition, sample C and D which have about l7wt% Corundum phase without the Cristobalite phase shows better electrical and mechanical properties than sample A and B which have the Cristobalite phase. In dielectrics test on porcelain samples with below l7wt% alumina composition, it was found that the amount of glass phase(SiO$_2$) have an main effect to decrease the dielectric loss(tan$\delta$), and the dielectric breakdown voltage of aluminous porcelain insulators was largely affected by its relative density. As a micro tracks analysis, HRB were measured, then the intensity of HRB increased with the amount of alumina composition. On the other hand, the propagation behaviors of cracks was fairly influenced by the distribution of pores.

주파수응답함수(FRF)를 이용한 자기 애자의 손상평가 (Damage Evaluation of Porcelain Insulators Using the Frequency Response Function)

  • 최인혁;손주암;오태근;윤영근
    • 한국전기전자재료학회논문지
    • /
    • 제32권2호
    • /
    • pp.122-128
    • /
    • 2019
  • Porcelain insulators have been used mainly for power line fixing and electrical insulation in transmission towers. Porcelain insulators have generally a 30 years desired life, but over 50% exceed their life expectancy. Since the damage to porcelain insulators is usually accompanied by enormous loss of human resource material, their efficient maintenance has emerged as an important issue. In this regard, this study applied a frequency response function (FRF) for integrity assessment of the insulator. The characteristics of the FRF according to damage types were identified and analyzed by the change in natural frequencies, curve shape, attenuation, and Nyquist diagram stability. The results showed significant differences in the FRF according to damage types, which can be used as basic data for the effective integrity assessment of porcelain insulators.

ANSYS를 이용한 현수애자의 계면팽창거동에 따른 특성 평가 (Simulation of Interface Ageing Effect of Suspension Insulator Using ANSYS)

  • 우병철;한세원;조한구
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권8호
    • /
    • pp.342-347
    • /
    • 2003
  • The suspension insulators are subjected to harsh environment in service for a long time. Long term reliability of the insulators is required for both mechanical and electrical performances. We studied an analysing method to find out a deformation of brittle porcelain with a thermal expansion of simulation analysis and experimental results show that cement volume growths affect severely to b mechanical failure ageing.

초고압 현수애자의 Pin 형상에 따른 응력해석 (Analysis for Stress According to Pin Type of High Voltage Suspension Type Insulator)

  • 조한구;박기호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.140-142
    • /
    • 2001
  • In this study mechanical for stress according to Pin type of high voltage suspension type insulator. R-shaped metal pin. and a tapered metal pin having a tensile pin having a tensile strength of more than the breaking strength of insulating body are provided in porcelain insulating bodies, and a suspension insulator according to the present invention, a test for determining the tensile strength of the insulating body was made and the results. These insulators are designed and produced by using the computer analysis of mechanical and electrical stresses together with the technical know-how accumulated from long year of study into every respect of insulators.

  • PDF