• 제목/요약/키워드: Porcelain Insulator

검색결과 140건 처리시간 0.023초

ANSYS를 이용한 송전용 자기재 애자의 장력에 따른 특성 변화 (A Variation of Maximum Stress with Axial Loading in Porcelain Insulators for Transmission Line using ANSYS)

  • 우병철;한세원;조한구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마연구회
    • /
    • pp.104-107
    • /
    • 2003
  • The ageing cause in many porcelain suspension insulators which occur on transmission and distribution line with dead-end stings is mechanical stress in interface between porcelain and cement materials. It is known that the principal mechanical stress which give electrical failure is the results of the displacement is due to cement growth. We studied an analysing method to find out a deformation of brittle porcelain with a thermal expansion of cement for suspension insulator. These simulation analysis and experimental results show that cement volume growths affect severely to be mechanical failure ageing. These simulation analysis and experimental results show that axial loading affects of Porcelain insulators severely to be mechanical failure ageing.

  • PDF

초고압용 폴리머 애자의 산불영향 연구 (A study of the Influence of Forest Fire on Polymer Insulator for UHV)

  • 최인혁;최장현;정윤환;이동일
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.254-259
    • /
    • 2005
  • Big fire such as mountain fire my cause the prevention of the functions of the overhead cables and insulators, which may affect the operation of the transmission lines. Therefore, in order to understand the effect of the mountain fire on the polymeric insulator for transmission lines, the author observed the deformation of the sheds of the polymeric insulators and the change of the discs of the porcelain insulators under fire, and investigated the electrical and mechanical characteristics of the insulators after the ignition test. As the result the following conclusions were obtained. First, the porcelain insulator was degraded in electrical characteristics when the insulator was subjected to the fire for approximately 5 minutes; whereas, the polymeric insulator was not degraded though there were some damage on its sheds. Second, after 20 minute exposure to the fire, the polymeric insulator lost a lot of parts of sheds, but the electrical characteristics was lowered by around 20%, but the porcelain insulators were electrically degraded by more than 80%.

  • PDF

Al2O3 첨가에 따른 송전용 현수애자의 전기적 성능 평가 연구 (A Study on the Electric Performance of Porcelain Insulator with Al2O3 Addition in Transmission Line)

  • 최인혁;최장현;이동일;최연규;조한구;한세원;박영창
    • 한국전기전자재료학회논문지
    • /
    • 제18권1호
    • /
    • pp.96-103
    • /
    • 2005
  • To analyze the reason of aging deterioration in transmission line insulators, we performed a various kind of test and investigated mechanical and electrical characteristics of insulators. Test samples consisted of K-1989(36,000lbs), K-1995(36,000lbs) and K-2001(36,000lbs) type insulators which have been used in domestic 154 kV transmission lines. As a result of this test, the facts turned out K-2001 insulator which contain 17 wt.% alumina has better physical characteristics than K-1989 insulator which contain 8 wt% alumina. Relativity density and fracture toughness of K-1989 porcelain are 94.2 % and 1.4 MPa\ulcornerm$^{1}$2// but relativity density and fracture toughness of K-2001 porcelain are 96 % and 1.7 MPa\ulcornerm$^{1}$2//. K-2001 insulators show a good performance not only in a physical property test but also in power arc test and steep front of wave flashover test which is performed to evaluate electrical characteristics.

산불영향에 따른 송전용 폴리머애자의 특성 (The Influence of Forest Fire on the Characteristics of Polymer Insulator for Transmission Lines)

  • 이동일;정용운;유근양;최인혁
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권3호
    • /
    • pp.127-131
    • /
    • 2005
  • Big fire such as mountain fire may cause the prevention of the functions of the overhead cables and insulators, which may affect the operation of the transmission lines. In the worst case, this kind of disaster may have a huge effect on the whole industry of a country. However, the study on the effect of the mountain fire on the transmission line is very rare. Therefore, in order to understand the effect of the mountain fire on the polymeric insulator for transmission lines, the author observed the deformation of the sheds of the polymeric insulators and the change of the discs of the porcelain insulators under fire, varying the ignition time using the artificial ignition testing equipment which simulates the mountain fire, and investigated the electrical and mechanical characteristics of the insulators after the ignition test. For the test, the miniature insulators made of polymeric material and porcelain have been utilized. As the result, the following conclusions were obtained. First, the porcelain insulator was degraded in electrical characteristics when the insulator was subjected to the fire for approximately 5 minutes; whereas, the polymeric insulator was not degraded though there were some damage on its sheds. Second, after 20 minute exposure to the fire, the polymeric insulator lost a lot of parts of sheds, but the electrical characteristics was lowered by around $20\%$, but the porcelain insulators were electrically degraded by more than $80\%$.

알루미나 조성에 따른 송전용 자기애자의 특성 분석 (Analysis on Properties of Porcelain Insulators with Alumina Composition)

  • 조한구;이유정;윤한수;한세원;최인혁;최연규
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.317-318
    • /
    • 2005
  • This paper presents the analysis on the properties of porcelain insulators with the manufactured year. The domestic porcelain insulators manufactured in 1995, 1997, and 2002 and the imported one are prepared. The content of alumina was increased with the manufactured year, and the hardness of ceramic parts showed the same trend. Moreover, the distribution and the size of pore were more decreased and reduced on the junction parts between the glaze and the ceramic. Therefore, we concluded that the domestic porcelain insulators have been improved with the lapse of time.

  • PDF

송전용 자기재 애자의 시멘트 변위 응력에 관한 시뮬레이션 (A Simulation on the Displacement Stress of Cement in Porcelain Insulators for Transmission Line)

  • 한세원;조한구;우병철;정길조;이동일;최인혁
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.476-479
    • /
    • 2002
  • The ageing cause in many porcelain suspension insulators which occur on transmission and distribution line with dead-end stings is mechanical stress in interface between porcelain and cement materials. It is known that the principal mechanical stress which give electrical failure is the results of the displacement is due to cement growth. We studied the effect of cement displacement resulting environmental ageing parameters on porcelain insulator mechanical properties for transmission line by simulation (ANSYS/NASTRAN program) and test methods. These simulation analysis and experimental results show that cement volume growth affects severely to be mechanical failure ageing.

  • PDF

에폭시 BAR-TYPE 배전용 현수애자 개발 (Suspension insulator development of Epoxy casting Bar-Type)

  • 김주용;송일근;김상준;권동진;김석기;곽희로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1529-1531
    • /
    • 1996
  • Porcelain suspension insulators have teen used for a long time in distribution line. However, Puncture breakdowns in porcelain insulators caused by weaking cement between metal fitting nad porcelain material. There is little puncture breakdown in Epoxy casting insulator. This paper presents electrical test results for the development of suspension insulator used Cycloaliphatic Epoxy resin. Items of test results are as follow - Power Arc test - Aging test - Impulse flashover voltage tests - Puncture tests et.al.

  • PDF

에폭시 캐스팅수지 애자의 형상해석 (The design analysis of epoxy casting resins insulator for distribution line)

  • 송일근;김영래;박구범;곽희로;전상준;권동진;김석기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.411-413
    • /
    • 1995
  • Porcelain insulators have been used for the almost all of the suspension insulators in distribution line. However, Puncture breakdowns in porcelain insulators caused by westing cement between metal fitting and porcelain material. There is little puncture breakdown in Epoxy casting insulator. This paper presents a new design technique for the development of suspension insulator used Cycloaliphatic Epoxy resin. The design was performed on the basis of two conditions (weather conditions for the past 30 years and the existing installation conditions of KEPCO) and was proven of its adaptability by FEM method.

  • PDF

인장시험에 의한 자기재 현수애자의 수명평가에 관한 연구 (A Study on the Lifetime Evaluation of Porcelain Suspension Insulator Using Tensile Test)

  • 김찬영;송일근;김주용;이병성;한재홍;윤태상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1596-1598
    • /
    • 2000
  • This paper presents the results of lifetime evaluation for porcelain suspension insulator using tensile test. The specimens were collected from the branch offices of the KEPCO. The tensile tests were performed with the instron which had the speed of 1mm per minites. The factors of quality were calculated with the maximum tensile strength measured from each specimens. With the quality factors, a factor of lifetime was determined. The lifetime of porcelain suspension insulator as a factor of fabricated years was evaluated.

  • PDF