• Title/Summary/Keyword: Popping

Search Result 65, Processing Time 0.019 seconds

Physicochemical Properties of Extruded Rice Flour and Gelatinization Popped Rice Flour (제조 방법이 다른 팽화미 분말의 이화학적 특성)

  • Lee, Jung-Eun;Kim, Yu-Jin;Cho, Mun-Gyeong;Park, Shin-Young;Kim, Eun-Mi;Cho, Yong-Sik;Choi, Yoon-Hee
    • The Korean Journal of Food And Nutrition
    • /
    • v.25 no.4
    • /
    • pp.850-854
    • /
    • 2012
  • This study is carried out in order to develop food materials for the promotion of rice consumption. In this study, we researched the physicochemical properties of extruded rice flour (ER) and gelatinization popped rice flour (GPR) by the extrusion process and by the popped method with milled rice and brown rice. The extrusion process used a couple of screw extruders. The extrusion parameter was kept constant at a feed moisture content of 25%, barrel temperature of $120^{\circ}C$ and screw speed of 400 rpm. GPR was prepared by batch popping machine after gelatinization of rice. In order to evaluate the physicochemical properties of ER and GPR, as well as the gelatinization rate, water soluble index (WSI), water adsorption index (WAI), DPPH radical scavenging activity and total dietary fiber content, the color value was carried out. The gelatinization rate was similar to 71.1~73.8%. Further, the results of WSI and WAI were increased at ER and GPR compared to the raw materials; ER was also higher than GPR. DPPH radical scavenging activity and total dietary fiber content showed a tendency to reduce after extrution and popping. As a result of the color value, the L value of ER decreased more than the raw materials, whereas GPR increased at a and b values.

Analysis of Liquid-Propellant Rocket Engine(KL-3) Unstable Combustion Characteristics of Vertical Installation (수직장착에서의 액체추진제 로켓엔진(KL-3) 불안정 연소특성에 관한 연구)

  • 하성업;권오성;이정호;김병훈;한상엽;김영목
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.7 no.1
    • /
    • pp.18-27
    • /
    • 2003
  • To perform combined tests with propellant feeding system and engine, which were developed for KSR-III launcher, vertical test stand was organized and a series of hot-fire combustion tests were carried out with engines of several injector faceplate types. In hot-fire tests in vertical installation, combustion instabilities occurred right after ignition with an engine without baffle, and such combustion instabilities did not occur at ignition add during mainstage operation for an engine with STS or composite baffle. 1.regular and temporary pressure pulsations(popping) were detected during steady operation with a baffle engine, however a development to combustion instabilities with resonant mode was highly suppressed by baffle. With a series of tests, it was confirmed that the last developed engine, which has composite baffle, was operated successfully in KSR-III flight propulsion system.

A Study on the Mandibular Rotational Movement using Biopak Sysytem (BIOPAK을 이용한 하악의 회전운동에 관한 연구)

  • Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • v.19 no.2
    • /
    • pp.193-203
    • /
    • 1994
  • The author performed this study for investigation of the magnitude of mandibular positional change caused by joint sound during mandibular opening and closing movement. There have been many studies stated mandibular border movement or other functional movement, and there also have been many studies reported clicking sound related to mandibular movement speed, trajectory and clinicl course of temporomandibular disorders(TMDs), but there have not been so many studies stated spatial mandibular position accompanied by joint sound. For this study 46 TM joint from the patients with TMDs were used and they were compared by character and occuring phase of the joint sound. Synchronized data which were amplitude and frequency of joint sound and amount of mandibular positional change were collected through sonopak and BioEGN rotate of Biopak system, respectively. Mandibular position was analyzed for translational and rotational movement change between before and after joint sound. The obtained data were processed with SAS program and summary of this paper were as follows : 1. Mean value of the amount of translational movement in whole joints were 6.0mm in vertical direction, 3.3mm in anteroposterior direction and 0.8mm in lateral direction between before and after joint sound. 2. Mean value of the amount of translational movement in clicking joinnts showed slightly increased tendency than in popping joints. 3. The amount of mandibular change in translational movement during closing phase were more than during opening phase. 4. The amount of mandibular rotational change in whole joints were $1.1^{\circ}$, 1.0mm in frontal plane and $0.9^{\circ}$, and 0.8mm in horizontal plane. 5. The amount of rotational movement were more in clicking joints than in popping joints and were more during closing phase than during opening phase, but statistically significance were showed only in frontal plane.

  • PDF

An Analytical Study on Evaluation of Opening Performance of Steam Safety Valve for Nuclear Power Plant (원자력 증기용 안전밸브의 개방성능 평가를 위한 해석적 연구)

  • Sohn, Sangho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.1
    • /
    • pp.5-11
    • /
    • 2014
  • The purpose of this paper is to investigate an analytical approach for opening performance evaluation of the nuclear pressure safety valve based on standard codes such as ASME or KEPIC. It is well-known that safety valve is considered as one of pressure relief valves for protecting a boiler or pressure vessel from exceeding the maximum allowable working pressure. When pressure in a container reaches its set pressure, the safety valve commences discharging the internal fluid by a sudden opening called as popping. Safety valve is usually evaluated by set pressure, full open, blow-down, leakage and flow capacity. The test procedure and technical requirement for performance evaluation is described in international code of ASME code such as BPVC. The opening characteristics of steam safety valve can be analyzed by computational fluid dynamics (CFD) and steam shaft dynamics. First, the flow analysis along opening process is simulated by running the CFD models of the ten types of opening steps from 0 to 100%. As a analysis result, the various CFD outputs of flow pattern, pressure, forces on the disc and mass flow at each simulation step is demonstrated. The lift force is calculated by using the forces applied on disc from static pressure and secondary flow. And, the effect of huddle chamber or control chamber is studied by dynamic analysis based on CFD simulation results such as lift force. As a result, dynamics analysis shows opening features according to the sizes of control chamber.

Impact of Energy and Access Methods on Extrahepatic Tumor Spreading and the Ablation Zone: An Ex vivo Experiment Using a Subcapsular Tumor Model

  • Jin Sil Kim;Youngsun Ko;Hyeyoung Kwon;Minjeong Kim;Jeong Kyong Lee
    • Korean Journal of Radiology
    • /
    • v.20 no.4
    • /
    • pp.580-588
    • /
    • 2019
  • Objective: To evaluate the impact of energy and access methods on extrahepatic tumor spreading and the ablation zone in an ex vivo subcapsular tumor mimic model with a risk of extrahepatic tumor spreading. Materials and Methods: Forty-two tumor-mimics were created in bovine liver blocks by injecting a mixture of iodine contrast material just below the liver capsule. Radiofrequency (RF) ablations were performed using an electrode placed parallel or perpendicular to hepatic surface through the tumor mimic with low- and high-power protocols (groups 1 and 2, respectively). Computed tomography (CT) scans were performed before and after ablation. The presence of contrast leak on the hepatic surface on CT, size of ablation zone, and timing of the first roll-off and popping sound were compared between the groups. Results: With parallel access, one contrast leak in group 1 (1/10, 10%) and nine in group 2 (9/10, 90%) (p < 0.001) were identified on post-ablation CT. With perpendicular access, six contrast leaks were identified in each group (6/11, 54.5%). The first roll-off and popping sound were significantly delayed in group 1 irrespective of the access method (p = 0.002). No statistical difference in the size of the ablation zone of the liver specimen was observed between the two groups (p = 0.247). Conclusion: Low-power RF ablation with parallel access is proposed to be effective and safe from extrahepatic tumor spreading in RF ablation of a solid hepatic tumor in the subcapsular location. Perpendicular placement of an electrode to the capsule is associated with a risk of extrahepatic tumor spreading regardless of the power applied.

Effect of Drying Method of Gelatinized Rice on Quality of Popped Rice for Preparing Salyeotgangjung (호화쌀의 건조방법이 쌀엿강정용 팽화쌀의 품질에 미치는 영향)

  • Kim, Myoung-Ae
    • Journal of the Korean Society of Food Culture
    • /
    • v.18 no.5
    • /
    • pp.437-442
    • /
    • 2003
  • This study was conducted to confirm the effect of drying method on quality of popped rice for making salyeotgangjung(popped rice lump with malt syrup) in process of drying gelatinized rice. The drying were performed at dry oven or convection oven, at $30^{\circ}C,\;50^{\circ}C\;and\;105^{\circ}C$, respectively. There were not significant differences in the hardness of popped rice among the drying methods. The dry at $30^{\circ}C$ constant in dry oven showed higher popping rate, good external surface, uniformed and well developed internal cell size. The dry at $30^{\circ}C$ in convection oven and $50^{\circ}C$ constant temperature in dry oven showed low expansion and poor external surface, respectively. In conclusion, the drying at $30^{\circ}C$ in non-convection oven had the highest quality of popped rice for salyeotgangjung.

Bubble Popping Augmented Reality using Haptic Mouse (햅틱 마우스 기반 버블포핑 증강현실)

  • Lee, Woo-Keun;Jeong, Da-Un;Jang, Seong-Eun;Kim, Man-Bae
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2010.07a
    • /
    • pp.205-207
    • /
    • 2010
  • 본 논문에서는 버블포핑을 구현하는 증강현실 기법을 제안한다. 제안 기법은 진동촉각햅틱 마우스, 비디오 입력용 웹캠, 마커 패턴 영상, 그래픽 구 버블 객체, 그래픽 마우스 등으로 구성된다. 마우스의 이동에 따라 그래픽 마우스가 3차원 공간상에서 이동하면서 버블과의 충돌이 발생하게 되면, 충돌시 발생하는 버블의 이벤트로 fade-out과 diverge and fade-out의 버블 효과를 구현한다. 제안 시스템은 ARToolkit 및 OpenGL을 기반으로 제작되었으며, 시각적인 마커 기반 시스템으로 버블의 움직임과 사용자의 인터랙션을 통해, 버블 포핑의 증강현실을 전달한다.

  • PDF

Finite Element Analysis for Thermal Stresses of Microaccelerometers (마이크로가속도계의 열응력에 대한 유한요소해석)

  • 김옥삼
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.100-104
    • /
    • 2000
  • This paper deals with finite element analyses of residual stresses causing popping up which are induced in micromachining processes of a mcroaccelerometers. After heating the tunnel gap up to 100 degree and get it through the cooling process and the additional bean up to 80 degree and get is through the cooling process. We learn the thermal internal stress of each shape and compare the results with each other after heating the tunnel gap up to 400 degree during the Pt deposition process. We want to seek after the real cause of this pop up phenomenon and diminish this by change manufacturing processes of microaccelerometer by electrostatic force.

  • PDF

Epiduroscopic Removal of a Lumbar Facet Joint Cyst

  • Jin, Hyun Seung;Bae, Jun Yeol;In, Chi Bum;Choi, Eun Joo;Lee, Pyung Bok;Nahm, Francis Sahngun
    • The Korean Journal of Pain
    • /
    • v.28 no.4
    • /
    • pp.275-279
    • /
    • 2015
  • Facet joint synovial cysts are usually associated with osteoarthritis of the adjacent facet joint and/or spondylolisthesis. In between the conservative and operative ends of the treatment spectrum lie minimally invasive techniques such as cyst rupture using epiduroscopy. In this report, we describe an 82-year-old male patient presenting with low back pain radiating to his lower left extremity and associated paresthesia. Magnetic resonance imaging of the lumbar spine revealed a synovial cyst at left L4/5 facet joint. Using epiduroscopy, the cyst was mechanically ruptured by popping it with the tip of the scope. The patient remained symptom-free at his successive visits until 12 months after the procedure, and was opened for desired follow up.

Analyses Thermal Stresses for Microaccelerometer Sensors using SOI Wafer(I) (SOI웨이퍼를 이용한 마이크로가속도계 센서의 열응력해석(I))

  • Kim, O.S.
    • Journal of Power System Engineering
    • /
    • v.5 no.2
    • /
    • pp.36-42
    • /
    • 2001
  • This paper deals with finite element analyses of residual stresses causing popping up which are induced in micromachining processes of a microaccelerometer sensors. The paddle of the micro accelerometer sensor is designed symmetric with respect to the direction of the beam. After heating the tunnel gap up to 100 degree and get it through the cooling process and the additional beam up to 80 degree and get it through the cooling process. We learn the thermal internal stresses of each shape and compare the results with each other, after heating the tunnel gap up to 400 degree during the Pt deposition process. Finally we find the optimal shape which is able to minimize the internal stresses of microaccelerometer sensor. We want to seek after the real cause of this pop up phenomenon and diminish this by change manufacturing processes of microaccelerometer sensor by electrostatic force.

  • PDF