• Title/Summary/Keyword: Poor-contact

검색결과 225건 처리시간 0.029초

Anti-gelling Effect of Poly(methacrylic acid, methyl methacrylate) on Cefuroxime Axetil Composition

  • Shim, Ji-Yeon;Wang, Hun-Sik;Kwon, Min-Chang;Park, Jun-Sang
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2-2
    • /
    • pp.237.1-237.1
    • /
    • 2003
  • Cefuroxime axetil, a broad spectrum antibiotic, has been known to form a gelatinous mass in contact with aqueous media, which could lead to poor dissolution. Therefore, this study was conducted for removing the gelling phenomenon and thereby obtaining a favorable dissolution profile. We have found that the addition of poly (methacrylic acid, methyl methacrylate) could not only inhibit the tendency of cefuroxime axetil to form a gel but also showed the good dissolution profile compared to the formula without poly (methacrylic acid, methyl methacrylate). (omitted)

  • PDF

용량성 결합 능동 전극의 공통 모드 구동 차폐 (A Study on comnon-mode-driven shield for capacitive coupling active electrode)

  • 임용규
    • 융합신호처리학회논문지
    • /
    • 제13권4호
    • /
    • pp.201-206
    • /
    • 2012
  • 간접접촉 심전도 측정(Indirect-Contact ECG)은 일상생활에서의 무구속 무자각 측정에 적합한 심전도 측정 방법이다. 본 연구는, 간접접촉 심전도 측정에서 크게 관측되는 60Hz 전원선 잡음을 줄이기 위한 새로운 방법으로, 공통모드 구동 차폐 방식을 제안하였다. 공통 모드 구동 차폐 방식은, 간접 접촉 심전도에서 사용되는 용량성 결합 능동 전극(Capacitive coupling active electrode)을 둘러싼 전기적 차폐(electric shield)의 전압을 공통 모드 전압과 동일하게 유지하는 방법이다. 이 방법은 공통모드 전압의 크기는 그대로 유지하지만, 의복 임피던스 차에 의한 공통모드 전압의 차동 모드 전환에 의한 잡음은 효과적으로 줄일 수 있다. 따라서 두 전극 사이의 의복의 임피던스 차이가 커서 공통 모드 전원 잡음이 심각한 간접 접촉 심전도 측정에서, 효과적으로 공통 모드 잡음을 줄일 수 있다. 실제 간접 접촉 심전도 측정에 제안된 방법을 적용한 결과로 이론적 예상보다는 60Hz 잡음 감소비가 적었지만, 60Hz 잡음이 크게 줄어드는 것을 확인할 수 있었다. 특히 의복 임피던스 차가 크게 발생하는 경우, 예상대로 잡음 감소비가 커짐을 볼 수 있었다. 제안된 방법은 접지 특성이 좋지 않은 측정 조건에서 전원 잡음을 줄이는데 유용할 것으로 기대된다.

Wettability of denture relining materials under water storage over time

  • Jin, Na-Young;Lee, Ho-Rim;Lee, Hee-Su;Pae, Ahran
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권1호
    • /
    • pp.1-5
    • /
    • 2009
  • STATEMENT OF PROBLEM. Poor wettability of denture relining materials may lead to retention problems and patient discomfort. PURPOSE. Purpose of this study is to compare and evaluate wettability of nine denture relining materials using contact angle measurements under air and water storage over time. MATERIAL AND METHODS. Nine denture relining materials were investigated in this study. Two heat-curing polymethyl-methacrylate(PMMA) denture base materials: Vertex RS, Lang, one self-curing polyethyl-methacrylate(PEMA) chairside reline resin: Rebase II, six silicone relining materials: Mucopren soft, Mucosoft, $Mollosil^{{R}}$ plus, Sofreliner Touch, GC $Reline^{TM}$ Ultrasoft, Silagum automix comfort were used in this experiment. Contact angles were measured using high-resolution drop shape analysis system(DSA 10-MK2, KRUESS, Germany) under three conditions(in air after setting, 1 hour water storage, and 24 hours water storage). Nine materials were classified into three groups according to material composition(Group 1: PMMA, Group 2: PEMA, Group 3: Silicone). Mean values of contact angles were compared using independent samples t-test and one-way ANOVA, followed by a Scheffe's post hoc analysis($\alpha$=0.01). RESULTS. Contact angles of materials tested after air and water storage increased in the following order: Group 1(PMMA), Group 2(PEMA), Group 3(Silicone). Heat-cured acrylic denture base resins had more wettability than silicone relining materials. Lang had the highest wettability after 24 hours of water storage. Silicone relining materials had lower wettability due to their hydrophobicity. Wettability of all denture relining materials, except Rebase II and $Mollosil^{{R}}$ plus, increased after 24 hours of water storage. CONCLUSIONS. Conventional heat-cured resin showed the highest wettability, therefore, it can be suggested that heat-cured acrylic resin is material of choice for denture relining materials.

리더와의 접촉빈도와 심리적 거리가 직무 디스트레스에 미치는 영향: 구성원이 인지하는 셀프리더십의 매개효과 (Contact Frequency and Psychological Distance between Leaders: Job Distress and Mediation through Employees' Perceived Self-Leadership)

  • 양회창;전준호;박종록
    • 유통과학연구
    • /
    • 제12권6호
    • /
    • pp.41-48
    • /
    • 2014
  • Purpose - This study aims to investigate a solution to reduce the negative reactions arising from the performance of duties or the job distress of workers in the service industry, because human resource statistics regarding workers in the service sector have been unreported, while concerns regarding exposure to emotional exertion and poor working conditions have been continuously increasing. Research design, data, and methodology - This study specifically focused on workers in highway service areas. It differs from previous studies because it involves the perspective of the person-organization fit and regards workers' cognition of leaders through the psychological distance toward the leader and the contact frequency between workers and leaders within the framework of the leader-individual fit. Moreover, this study highlights the role of the self-leadership of workers as an important factor that becomes manifested in the individual-level fit to the organization. Hence, this study investigates whether the positive role of the above factors, in turn, could reduce job distress. Workers from highway service areas in Gyeonggi-do province provided data; 141 valid questionnaires are collected. SPSS 19.0 and AMOS 19.0 were used to test the reliability and validity of constructs. Simple regression, multiple regression, and 3 step mediation tests were used to test the hypotheses after the correlation tests. Results - Results indicated that leader-member contact frequency and psychological distance have negative effects on job distress but positive effects on self-leadership. A mediation test revealed that self-leadership, in the relationships between contact frequency and job distress and between psychological distance and job distress, resulted in partial mediation and full mediation, respectively. Conclusions - The result can be understood through two different possible explanations. First, service area workers generally possess a positive perspective toward their leaders. This can be interpreted to mean that increased contact frequency and psychological distance would be considered as supports from the leader, rather than intrusive controls or management schemes. Therefore, the management in highway service areas should invest efforts in increasing contact frequency as well as maximizing psychological similarities by adopting the viewpoints of workers in terms of moral and ethical management, to reduce the workers' job distress. The results relating to self-leadership also indicate that increased contact frequency must be accompanied by intentions for the effective promotion of workers' self-leadership. It also signifies the necessity of a strategic approach by leaders to induce workers to perceive "in-group"ness as suggested both by the similarity-attraction theory and by the social identity theory. In addition, the results of the mediation test of self-leadership indicate that because workers' self-leadership activates upon increased contact frequency by the leader, it should not be a means of control and should not be utilized only from the perspective of management. It is also suggested that strategies such as transfer of authority could have a positive effect in promoting the expansion of self-influence from workers.

전기장판 열선 결함에 의한 전기화재 원인분석 (Fire Cause Analysis on Electric Pad Due to Defect of Hot Wires)

  • 송재용;사승훈;남정우;김진표;조영진;오부열
    • 한국안전학회지
    • /
    • 제27권2호
    • /
    • pp.7-12
    • /
    • 2012
  • This paper describes electrical fire on electric pad caused by defect of hot wires. We analyzed two type electric pad using by carbon type hot wire and magnetic shielded type hot wire. First, a carbon type hot wires electric pad is virtually impossible to connect hot wire as a method of electrical welding or soldering. In order to connect between hot wires, that has to splice carbon type material connector. If junction of hot wires was occurrence of poor connection on electric pad, it increase contact resistance on this junction point. With increasing contact resistance, junction of hot wires on electric pad generates local heating and finally leads to electrical fire. An electric pad using by a magnetic shielded type hot wire happened local heating on signal wire for sensing temperature-rise caused by applying current for magnetic shielded. With increasing local heating of signal wire, insulated coating of hot wire was melted. Finally the magnetic shielded type hot wire electric pad lead to electrical fire with breakdown between signal wire and hot wire. In this paper, we analyzed shape of damage in hot wire caused by electrical local heating and investigated fire cause on electric pad due to defect of hot wires.

Low Lung Cancer Resection Rates in a Tertiary Level Thoracic Center in Nepal - Where Lies Our Problem?

  • Thapa, Bibhusal;Sayami, Prakash
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권1호
    • /
    • pp.175-178
    • /
    • 2014
  • Background: Resection rates of lung cancer are low in general and especially in countries like Nepal. Advanced stage at presentation and poor general condition of the patient are the usual causes. Materials and Methods: In this prospective observational study, one hundred cases of lung cancer who presented at the Thoracic Surgery Unit between October 2011 and October 2012 were included. Results: Those aged in the $6^{th}$ and $7^{th}$ decades together accounted for 72/100 patients. The male to female ratio was 2:1. There was a mean-$29.2{\pm}14.2$ pack yrs smoking history with only five non-smokers. Seventy-six patients presented with locally advanced disease while 21 had metastases. Only three had local disease. The average time between onset of symptoms to first contact with a doctor was $2.3{\pm}5.3$ months (range: 0-35.6 months). Average time between first contact to referral was $50.4{\pm}65.7$ days (range-0-365). Only three patients were resected, one after neo-adjuvant chemotherapy. Advanced disease was the cause of unresectability in 95 cases. One of three patients with local disease had pulmonary functions allowing the warranted resection. $N_2$ disease with $T_{1-3}$ on CT scan was found in 47. Three of these patients underwent mediastinoscopy and all confirmed uninvolved $N_2$. Conclusions: Lung resection rates in our center remain low. Late presentation leading to advanced disease and poor pulmonary reserves preclude resection in most cases. More liberal use of mediastinal staging and better assessment of pulmonary functions may allow us to improve resection rates.

Nickel dust-induced occupational contact dermatitis by welding and grinding work in shipyard workers: a report of nine cases

  • Daehwan Kim;A Ram Kim;Hanjun Kim;Sunghee Lee;Byeonghak Seo;Ho Seok Suh;Chang Sun Sim;Heun Lee;Cheolin Yoo
    • Annals of Occupational and Environmental Medicine
    • /
    • 제34권
    • /
    • pp.7.1-7.10
    • /
    • 2022
  • Background: Occupational skin diseases are skin conditions that occur or worsen in relation to work and known to be the second most common type of occupational disease affecting individuals in the United States. In Korea, epidemiological reports related to occupational skin diseases are rare. But, no cases of occupational contact dermatitis caused by welding and grinding work have been reported previously. Case presentation: Nine male workers working in the production department for liquefied natural gas (LNG) ships in Ulsan complained of erythematous papules/patches and itching in various areas of the body after welding and grinding work. The work environment monitoring report revealed that the amount of nickel dust exceeded the time weighted average (TWA) and poor local ventilation status. Based on the symptoms and the overall results of surveys, several tests, and work environment monitoring report, the 2 workers who had positive patch-test reactions to nickel were diagnosed with nickel dust-induced allergic contact dermatitis. The other 7 workers were diagnosed that there was a high probability that they had nickel dust-induced irritant contact dermatitis. The 2 workers who had nickel dust-induced allergic contact dermatitis were recommended to switch their jobs. Conclusions: Nickel is one of the most common cause of allergic contact dermatitis. In this case, the dust was assumed to be created by welding work with a high nickel content new welding rod and subsequent grinding work, and the concentration of this dust exceeded the time weighted average. Thus, it is thought that the nickel dust may have caused contact dermatitis through continuous contact with the workers' exposed skin in a poorly ventilated space. Currently, several domestic shipbuilding companies are manufacturing LNG tankers using a new construction method. Consequently, it is highly likely that similar cases will occur in the future, which makes this case report meaningful.

Al2O3 층을 이용한 저온공정에서의 산화물 기반 트랜지스터 컨택 특성 향상 (Improved Contact property in low temperature process via Ultrathin Al2O3 layer)

  • 정성현;신대영;조형균
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2018년도 춘계학술대회 논문집
    • /
    • pp.55-55
    • /
    • 2018
  • Recently, amorphous oxides such as InGaZnO (IGZO) and InZnO (IZO) as a channel layer of an oxide TFT have been attracted by advantages such as high mobility, good uniformity, and high transparency. In order to apply such an amorphous oxide TFTs to a display, the stability in various environments must be ensured. In the InGaZnO which has been studied in the past, Ga elements act as a suppressor of oxygen vacancy and result in a decreased mobility at the same time. Previous studies have been showed that the InZnO, which does not contain Ga, can achieve high mobility, but has relatively poor stability under various instability environments. In this study, the TFTs using $IZO/Al_2O_3$ double layer structure were studied. The introduction of an $Al_2O_3$ interlayer between source/drain and channel causes superior electrical characteristics and electrical stability as well as reduced contact resistance with optimally perfect ohmic contact. For the IZO and $Al_2O_3$ bilayer structures, the IZO 30nm IZO channels were prepared at $Ar:O_2=30:1$ by sputtering and the $Al_2O_3$ interlayer were depostied with various thickness by ALD at $150^{\circ}C$. The optimal sample exhibits considerably good TFT performance with $V_{th}$ of -3.3V and field effect mobility of $19.25cm^2/Vs$, and reduced $V_{th}$ shift under positive bias stress stability, compared to conventional IZO TFT. The enhanced TFT performances are closely related to the nice ohmic contact properties coming from the defect passivation of the IZO surface inducing charge traps, and we will provide the detail mechanism and model via electrical analysis and transmission line method.

  • PDF

혈관 부착 비골 전위술을 이용한 슬관절 유합술 - 슬관절 전치환술 후 감염이 합병된 증례 - (Arthrodesis of the Knee with Vascularized Fibular Graft - A Case of Infected Total Knee Arthroplasty -)

  • 정덕환;한정수;이재훈;정선택;박진성
    • Archives of Reconstructive Microsurgery
    • /
    • 제15권2호
    • /
    • pp.111-116
    • /
    • 2006
  • An infection after total knee arthroplasty has many complications such as severe bone defect, skin and soft tissue problems, devastated general condition, so arthrodesis is preferred as treatment option. However, poor bony contact due to severe bone defect and inadequate conditions of the soft tissue often cause nonunion or severe limb shortening after arthrodesis. More over these conditions, it is not easy to choose appropriate fixative devices. In these situations, the arthrodesis using vascularized fibular graft can be the solution. Vascularized fibular graft (VFG) can playa role as a suitable material for the treatment of bone defects. And VFG can overcome poor blood circulation caused by scar tissues, and can be relatively more durable and adequate length. In the long term, VFG can be hypertrophied by weight bearing, and will give mechanical stablility. The purpose of the paper is to report the successful results of arthrodesis using VFG in a patient who got extensive bone defect after failed revision total knee arthroplasty with infection.

  • PDF

Childhood Emotional, Physical, and Sexual Abuse and Associations With Mental Health and Health-Risk Behaviors Among University Students in the Association of Southeast Asian Nations (ASEAN)

  • Thang, Nguyen Huu;Anh, Le Viet;Peltzer, Karl;Pengpid, Supa;Low, Wah Yun;Win, Hla Hla
    • Child Studies in Asia-Pacific Contexts
    • /
    • 제7권1호
    • /
    • pp.15-26
    • /
    • 2017
  • The aim of this study was to retrospectively estimate the prevalence of childhood emotional abuse (CEA), childhood physical abuse (CPA), and childhood contact sexual abuse (CCSA) in relation to adult poor mental health, addictive behavior, and other health-risk behaviors among university students in five ASEAN countries (Indonesia, Malaysia, Myanmar, Thailand, and Vietnam). In a cross-sectional survey, 3,240 undergraduate university students were randomly selected (M age = 20.5 years, SD = 1.6 years) to respond to a questionnaire including the Abuse section of the World Health Organization (WHO) Version 1 "Adverse Childhood Experiences International Questionnaire" (ACE-IQ) and other measures. The students reported 17.9% CEA, 28.2% CPA, and 22.4% CCSA, with the highest prevalence of CEA in Myanmar (30.9%) and CPA and CCSA in Vietnam (55.8% and 41.6%, respectively). In logistic regression models, adjusting for sociodemographic and social variables, the separate and cumulative effects of three types of child abuse (emotional, physical, and sexual) were found to increase the risks for poor adult mental health, addictive, and other health-risk behaviors.