• Title/Summary/Keyword: Pool water

Search Result 544, Processing Time 0.024 seconds

Implementation of an Underwater ROV for Detecting Foreign Objects in Water

  • Lho, Tae-Jung
    • Journal of information and communication convergence engineering
    • /
    • v.19 no.1
    • /
    • pp.61-66
    • /
    • 2021
  • An underwater remotely operated vehicle (ROV) has been implemented. It can inspect foreign substances through a CCD camera while the ROV is running in water. The maximum thrust of the ROV's running thruster is 139.3 N, allowing the ROV to move forward and backward at a running speed of 1.03 m/s underwater. The structural strength of the guard frame was analyzed when the ROV collided with a wall while traveling at a speed of 1.03 m/s underwater, and found to be safe. The maximum running speed of the ROV is 1.08 m/s and the working speed is 0.2 m/s in a 5.8-m deep-water wave pool, which satisfies the target performance. As the ROV traveled underwater at a speed of 0.2 m/s, the inspection camera was able to read characters that were 3 mm in width at a depth of 1.5 m, which meant it could sufficiently identify foreign objects in the water.

Enhancement of Nucleate Pool Boiling of a Wire-Wrapped Tube (와이어붙이관의 핵비등 열전달촉진)

  • 김내현;김정식;남기일
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.5
    • /
    • pp.1235-1244
    • /
    • 1994
  • In this study, experimental results of the nucleate boling of wire-wrapped tubes are provided. Both water and R-113 were boiled. Solid stainless steel wires, stranded copper wires and stranded nylon wires were tested. Solid stainless wire is effective to enhance the boiling of water. The performance is approximately the same(or slightly better at certain conditions) as that of GEWA-T tubes. For the test range of wire diameter 0.6 $mm{\le}d{\le}2.6 mm$, the optimum gap width increases as the wire diameter increases. The maximum heat transfer coefficient was obtained for the 1.0 mm diameter wire, and it is 1.6 times larger than that of the GEWA-T at the heat flux of 20 $kW/m^{2}.$ Solid stainless wire is also effective to enhance the boling of R-113 at low heat fluxes. The performance of the wire-wrapped tube approaches that of GEWA-T. At high heat fluxes, however, the enhancement decreases. The reason may be attributed to the cavity shape and the high wettability of the refrigerants. Stranded copper or nylon wire is effective to enhance the boiling of R-113. The performance is approximately the same(or slightly better) as that of GEWA-T tubes. Maximum heat transfer was obtained for the stranded nylon wire, and it is approximately 1.4 times larger than that for the GEWA-T at the heat flux of 20 $kW/m^{2}.$ The reason may be atrributed to the favorable thermal environment in the restricted regions formed by twisted wires.

Examination on Fire Extinguishing Performance of Full Cone and Hollow Cone Twin-fluid Atomizers: Effects of Supply Gas and Water Mist (중실원추형 및 중공원추형 2유체 미립화기의 화재 소화 성능 검토: 공급 기체와 미분무 영향)

  • Kim, Dong Hwan;Lee, Chi Young
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.28-36
    • /
    • 2019
  • In the present study, the effects of supply gas and water mist on the heptane pool fire extinguishing performance were investigated using the full cone and hollow cone twin-fluid atomizers. Air or nitrogen of 30 lpm (Liter per minute; L/min) was used as the supply gas, and the experiments were conducted under the water flow rate conditions of 0 lpm (i.e., discharge of air or nitrogen only) and 0.085 lpm (i.e., discharge of water mist with supply gas). Experimental results confirmed that the use of water mist discharge with the supply gas and full cone spray pattern reduced the fire extinguishing time as compared to that of only supply gas discharge and hollow cone spray pattern. In addition, for the discharge of water mist using the full cone twin-fluid atomizer, water mist significantly affected fire extinguishing performance, whereas the effect of the supply gas was less pronounced. On the other hand, for the discharge of water mist using the hollow cone twin-fluid atomizer, the fire extinguishing time was remarkably reduced by the supply of nitrogen, as compared with that of air, indicating that the supply gas as well as water mist can significantly affect fire extinguishing performance.

Experimental Investigation of the Combined Effects of Heat Exchanger Geometries on Nucleate Pool Boiling Heat Transfer in a Scaled IRWST (열교환기 형상이 축소한 IRWST 내부의 풀핵비등에 미치는 복합적인 영향에 대한 실험적 연구)

  • Kang, Myeong-Gie;Chun, Moon-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.28 no.1
    • /
    • pp.1-16
    • /
    • 1996
  • In an effort to determine the combined effects of major parameters of heat exchanger tubes on the nucleate pool boiling heat transfer in the scaled in-containment refueling water storage tank (IRWST), a total of 1,966 data for q'quot; versus ${\Delta}T$ has been obtained using various combinations of tube diameters, surface roughness, and tube orientations. The experimental results show that (1) increased surface roughness enhances heat transfer for both horizontal and vertical tubes, (2) the two heat transfer mechanisms, i.e.,enhanced heat transfer for both horizontal and vertical tubes, (2) the two heat transfer mechanisms, i.e., enhanced heat transfer due to liquid agitation by bubbles generated and reduced heat transfer by the formation of large vapor slugs and bubble coalescence are different in two regions of low heat fluxes (q'quot; $\leq$50kW/$m^2)$ and high heat fluxes (q'quot; $\geq$50kW/$m^2)$ depending on the orientation of tubes and the degree of surface roughness, and (3) the heat transfer rate decreases as the tube diameter is increased for both horizontal and vertical tubes, but the effect of tube diameter on the nucleate pool boiling heat transfer for vertical tubes is greater than that for horizontal tubes. Two empirical heat transfer correlations for q'quot;, one for horizontal tubes and the other for vertical tubes, are obtained in terms of surface roughness $({\varepsilon})$ and tube diameter (D). In addition, a simple empirical correlation for nucleate pool boiling heat transfer coefficient $(h_b)$ is obtained as a function of heat flux (q'quot;) only.ucleate pool boiling heat transfer coefficient $(h_b)$ is obtained as a function of heat flux (q'quot;) only.

  • PDF

An Assessment of Ascending Functions of the Pool-and-Weir Fishway at Jamsil Weir in the Han River (한강 잠실수중보 계단식 어도의 어류소상기능 평가)

  • Park, Sang-Deog;Shin, Sung-Sook;Ahn, Hyo-Yoon;Ma, Soo-Bong;Hwang, Chong-Seo
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.7
    • /
    • pp.541-552
    • /
    • 2004
  • In this paper, ascending functions of the pool-and-weir fishway which has been established for the upstream migration of migratory fish at Jamsil Weir in the lower part of the Han River was assessed by applying tile Existing Fishway Measurement Method, and measures to improve these functions were suggested. The primary fish which ascended the fishway during the period of measurement was Erythroculter erythropterus Basilewsky, greater than 29cm in the body length. A total of 361 individual fish were collected with traps established at the exit of the fishway The maximum ascending capacity for the fish was 2.53${\times}$10^{-3}$ fish/hr/g. The fishway of Jamsil Weir does not satisfy the various fish species inhabiting in the river. Especially, small fishes of lower swimming ability may not ascend the fishway because the difference in water levels between upper and lower pools in the fishway was too large at the exit and there was too much discharge flowing into the fishway. This fishway does not have a roll in the ascending function for other species except Erythroculter erythropterus Basilewsky and Hemibarbus labeo Pallas, for which swimming ability is great. In order to improve the ascending function of the fishway, the structures of the fishway need to be changed so that various species in the river can easily ascend and the fishway function be taken into consideration in operation of the gates of the weir. Additional construction of fishways on both sides of the lower flow channel are needed to correct a decline in the fishway effectiveness due to continuous flow over the fixed part of the weir.

Characterization of Benthic Macro-Invertebrate Communities and Hydraulic Factors in Small- Scale Habitats in a Polluted Stream (오염하천 소규모 서식처에서의 저서성 대형 무척추 동물군집과 수리학적 인자의 특성화)

  • Kwak, Inn-Sil;Liu, Guangchun;Park, Young-Seuk;Song, Mi-Young;Chon, Tae-Soo
    • Korean Journal of Ecology and Environment
    • /
    • v.35 no.4 s.100
    • /
    • pp.295-305
    • /
    • 2002
  • Benthic macro- invertebrates were collected in a 200 m reach located in the $3^{rd}$ order Yangjae Stream, a tributary of the Han River, Seoul, from April 1996 to March 1998. Although species richness was relatively low due to organic pollution, community abundance patterns appeared to be different depending upon location of the sampling sites. At the sample sites in the straight zone with high water velocity and large substrates, species richness was high and species relatively less-tolerant to organic pollution was additionally present. At the sample sites in the pool zone with lower velocity and high sedimentation, species richness was low and a few tolerant species to organic pollution were abundantly collected. The principle component analysis indicated that some sample sites in the straight zone appeared to be related to water velocity and shear velocity, and associated with diverse taxa less tolerant to organic pollution. Additionally the sample site transplanted with large substrates was associated wit]h hydraulic characters such as substrate diversity and roughness, and was related to species indicating partial recovery of water. The sample sites located at the pool zone tended to be associated with organic matter that had sedimented on to the substrates and the taxa tolerant to organic pollution, including Oligochaeta and Chironomus.

A Study on the Extinguishing Performance of Water Mist with Additives (첨가제가 혼합된 미세물분무의 소화성능에 관한 연구)

  • 이경덕;신창섭
    • Fire Science and Engineering
    • /
    • v.16 no.1
    • /
    • pp.1-7
    • /
    • 2002
  • Halogen-based fire suppressing agents have environmental problems because they cause the stratospheric ozone depletion and globe warming. Hence, fire suppression system using fine water mist became the center of interest as a substitution of halon. As a study about this, it is in progress to make the optimum droplet size by using water mist nozzles and to improve the extinguishing performance of water mist by using additives. Before this study, the extinguishing time of ethanol and n-heptane pool fire was measured with changing of water mist droplet size, flow density, discharge pressure, and fire size. In this study, on adding the additives to improve physical and chemical extinguishing performance of water mist, the extinguishing performance would evaluate and the optimum condition would find out. As a result, in case of ethanol pan 1 pool fire, the extinguishing time of the water mist by adding of 2.5 wt% NaCl and 0.3% AFFF got shorter 27% and 60% than the pure water mist. Adding of AFFF was to decrease the flame temperature by forming thin film on the fuel surface and to decrease the evaporation of n-heptane fuel. In case of NaCl, alkali salt crystals showed on the flame surface.

Extinguishment of Liquid Fuel Fire by Water Mist Containing Additives

  • Park, Jae-Man;Won, Jung-Il;Shin, Chang-Sub
    • International Journal of Safety
    • /
    • v.4 no.2
    • /
    • pp.24-29
    • /
    • 2005
  • An experimental study was presented for extinguishing characteristics of liquid fuel fire by water mist($Dv_{0.99}{\leq}200{\mu}m$) containing potassium acetate and sodium acetate trihydrate. To evaluate the extinguishing performance of water mist containing additives, the evaporation characteristics of a water droplet on a heated surface was examined. The evaporation process was recorded by a charge-coupled-device camera. Also, small-scale extinguishing tests were conducted for n-heptane pool fire in ventilated space. During the experiments, flame temperatures were measured, and concentrations of oxygen and carbon monoxide were analyzed by a combustion gas analyzer. The average evaporation rate of water droplet containing additives was lower than that of pure water at a given surface temperature and decreased with the concentration increase due to the precipitation of salt in the liquid-film and change of surface tension. In case of using additives, the fire extinguishing times was shorter than that of pure water at a given discharge pressure and it was because the momentum of a water droplet containing additives was increased. And also dissociated metal atoms, potassium or sodium, were reacted as a scavenger of the major radical species OH, H which were generated for combustion process. Moreover, at a high pressure of 4 MPa, the fire was extinguished through blowing effect as well as primary extinguishing mechanisms.

Preference of Physical Microhabitat on the $1^{st}$-class Endangered Species, Gobiobotia naktongensis inhabiting the Gam Stream, Tributary of the Nakdong River

  • Seo, Jin-Won;Kim, Hee-Sung;Yi, Hye-Suk;Jeong, Sun-A
    • Korean Journal of Ecology and Environment
    • /
    • v.42 no.4
    • /
    • pp.495-501
    • /
    • 2009
  • The study was conducted in 2007~2008 in order to understand preference of physical microhabitat on the $1^{st}$-class endangered species, Gobiobotia naktongensis inhabiting the Gam Stream, tributary of Nakdong River. The total number of fish caught from the study sites was 3,671 representing 7 families 24 species. There were 8 Korean endemic species including Odontobutis platycephala, and 2 introduced species (Carassius cuvieri, Micropterus salmoides) were found. According to investigation and analysis of physical microhabitat on Gobiobotia naktongensis caught in the Gam Stream, a total of 57 individuals were found at shallow depth (0.14~0.46 m) and run (0.239~0.585m $sec^{-1}$). As a result of sieve analysis, stream beds consisted of about 1% gravel and 99% sand (83.4% coarse sand, 15.6% find sand). Therefore, Gobiobotia naktongensis seemed to inhabit shallow-run with coarse sand bed than deep-pool microhabitat. The findings indicate preference of physical microhabitat on Gobiobotia naktongensis, and it is important to enhance efficiency of fish conservation and ecological restoration with understanding species-specific characteristics in microhabitat including protected species.

Analysis of Efficiency of Solar Hot Water System based on Energy Demand (에너지 수요처의 사용특성에 따른 태양열 급탕시스템의 효율분석)

  • Jun, Yong-Joon;Park, Kyung-Soon
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.5
    • /
    • pp.39-47
    • /
    • 2017
  • In a hot water system using solar energy, solar heat is not simply collected by the heat collecting plate, but by heat exchange between the solar collector (flat or vacuum type) and the hot water storage tank. Therefore, the amount of collected solar energy depends on the hot water usage patterns that determine the temperature of the thermal storage tank. Also, if the temperature of the hot water stored in the storage tank exceeds the dangerous temperature during the summer, the heat must be released for safety. If the temperature of the hot water in the storage tank is low, it is necessary to heat by the auxiliary heat source. In this study, three buildings are defined as hotel, swimming pool, and school facilities. And we calculated the released heat energy, auxiliary heat source, and pure storage heat energy based on different hot water usage patterns and installation angle of the solar collectors.