• Title/Summary/Keyword: Pool Temperature

Search Result 351, Processing Time 0.027 seconds

A Study on Welding Distortion of GTA Circular Type Lap Joint in STS304L Thin Plate (STS304L 박판 원형 겹치기 GTA 용접부의 용접 변형 예측에 관한 연구)

  • Kim, Il-Ho;Kim, Ha-Geun;Shin, Sang-Beom;Park, Dong-Hwan
    • Journal of Welding and Joining
    • /
    • v.30 no.5
    • /
    • pp.57-63
    • /
    • 2012
  • The purpose of this study is to evaluate the welding distortion of the circular type lap joint in STS304L of 0.7mm thickness by using FEA. In order to do it, a heat input model for GTA welding process with non-consumable electrode was established through comparing the molten pool shapes and temperature distributions obtained by both FEA and experiment. With the heat input model, the welding distortion of the circular type lap joint was evaluated by 3-D FEA. From FEA results, it was found that 3-D FEA with proper heat input model can be used for the evaluation of the excessive distortion of the circular type lap joint of STS304L thin plate. In addition, the root cause of the excessive distortion in the weld was also identified as the excessive compressive residual stress in the tangential direction of the weld.

A multi-scale analysis of the interdecadal change in the Madden-Julian Oscillation (MJO의 다중스케일 분석을 통한 수십년 변동성)

  • Lee, Sang-Heon;Seo, Kyong-Hwan
    • Atmosphere
    • /
    • v.21 no.2
    • /
    • pp.143-149
    • /
    • 2011
  • A new multi-timescale analysis method, Ensemble Empirical Mode Decomposition (EEMD), is used to diagnose the variation of the MJO activity determined by 850hPa and 200hPa zonal winds from the National Centers for Environmental Prediction/National Center for Atmospheric Research (NCEP/NCAR) Reanalysis data for the 56-yr period from 1950 to 2005. The results show that MJO activity can be decomposed into 9 quasi-periodic oscillations and a trend. With each level of contribution of the quasi-periodic oscillation discussed, the bi-seasonal oscillation, the interannual oscillation and the trend of the MJO activity are the most prominent features. The trend increases almost linearly, so that prior to around 1978 the activity of the MJO is lower than that during the latter part. This may be related to the tropical sea surface temperature(SST). It is speculated that the interdecadal change in the MJO activity appeared in around 1978 is related to the warmer SST in the equatorial warm pool, especially over the Indian Ocean.

A REVIEW OF INHERENT SAFETY CHARACTERISTICS OF METAL ALLOY SODIUM-COOLED FAST REACTOR FUEL AGAINST POSTULATED ACCIDENTS

  • SOFU, TANJU
    • Nuclear Engineering and Technology
    • /
    • v.47 no.3
    • /
    • pp.227-239
    • /
    • 2015
  • The thermal, mechanical, and neutronic performance of the metal alloy fast reactor fuel design complements the safety advantages of the liquid metal cooling and the pool-type primary system. Together, these features provide large safety margins in both normal operating modes and for a wide range of postulated accidents. In particular, they maximize the measures of safety associated with inherent reactor response to unprotected, doublefault accidents, and to minimize risk to the public and plant investment. High thermal conductivity and high gap conductance play the most significant role in safety advantages of the metallic fuel, resulting in a flatter radial temperature profile within the pin and much lower normal operation and transient temperatures in comparison to oxide fuel. Despite the big difference in melting point, both oxide and metal fuels have a relatively similar margin to melting during postulated accidents. When the metal fuel cladding fails, it typically occurs below the coolant boiling point and the damaged fuel pins remain coolable. Metal fuel is compatible with sodium coolant, eliminating the potential of energetic fuel-coolant reactions and flow blockages. All these, and the low retained heat leading to a longer grace period for operator action, are significant contributing factors to the inherently benign response of metallic fuel to postulated accidents. This paper summarizes the past analytical and experimental results obtained in past sodium-cooled fast reactor safety programs in the United States, and presents an overview of fuel safety performance as observed in laboratory and in-pile tests.

A Study on the Prediction of Welding Distortion and Residual Stress for Channel I Butt SA Weldment Using FE Analysis (유한요소해석을 이용한 채널 I 형 잠호 맞대기 용접부의 변형 및 잔류 응력 예측에 관한 연구)

  • Shin, Dae-Hee;Shin, Sang-Beom;Lee, Joo-Sung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.44 no.6
    • /
    • pp.598-604
    • /
    • 2007
  • The purpose of this study is to establish the predictive method of welding distortion and residual stress for the channel I butt SA (submerged arc) weldment using FEA. In order to do it, the heat input model for the weldment was defined as the combined heat source with the surface heat flux of gaussian distribution and volumetric heat source uniformly distributed within weld groove by comparing the shapes of molten pool and temperature distribution obtained by FEA with those of experiments. The arc efficiency of SA welding for two-dimensional FE analysis was evaluated as 0.85. The welding distortion and residual stress of the weldment obtained by FEA and heat input model proposed have a good agreement with those obtained by experiment. Based on the results, it was suggested that the proper heat input model should be required to evaluate the welding distortion for weldment.

Experimental Study on Heat Transfer Characteristics of HFC134a for Enhanced Tubes Used in a Flooded Evaporator (HFC134a 만액식 증발전열관 외부형상 변화에 따른 열전달 특성실험)

  • Yang, Seung-Woo;Lee, Young-Su;Jeong, Jin-Hee;Kang, Yong-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.12
    • /
    • pp.971-976
    • /
    • 2006
  • The objectives of this paper are to study the characteristics of pool boiling heat transfer for enhanced tubes used in the evaporator of turbo chiller and to provide a guideline for optimum design of an evaporator using HFC134a. Three different enhanced tubes are tested at 4 different saturation temperatures. The wall super heated temperature difference ranges from $0.5^{\circ}C\;to\;3.5^{\circ}C$. The refrigerant, HFC134a evaporates on the outside of the tube while the chilled water flows inside the tube. This study provides experimental heat transfer coefficients for evaporation on the enhanced tubes. It is found that the turbo-II tube provides the highest heat transfer coefficient.

An Influence of Corium Composition Variations on a Spontaneous Steam Explosion in Severe Accidents in a Nuclear Reactor (원자로 노심용융물의 성분비 변화가 증기폭발에 미치는 영향)

  • Kim, Jong-Hwan;Park, Ik-Kyu;Hong, Seong-Wan;Min, Beong-Tae;Song, Jin-Ho;Kim, Hee-Dong
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2041-2046
    • /
    • 2004
  • Recently series of steam explosion experiments have been performed in the TROI facility to identify the influence of corium compositions on the occurrence of a spontaneous steam explosion varying corium melt composition. The compositions of the corium were 0 : 100, 50 : 50, 70 : 30, 80 : 20 and 87 : 13 at weight percent of $UO_2$ to $ZrO_2$, and the mass of the corium was about 10kg. Corium melt at 0 : 100 weight percent (pure zirconia) caused a strong spontaneous steam explosion, and melt at 70 : 30 weight percent(eutectic corium) led to a weak steam spike, while melts at other compositions did not result in spontaneous steam explosions, when they came into contact with 67cm deep water pool at room temperature. It seems that the explosivity of pure zirconia is stronger than that of corium at other compositions and a steam explosion is not likely to occur with corium melts at non-eutectic compositions which are included in mushy zone region.

  • PDF

A Study on Finned Tube Used in Turbo Refrigerator(II) - on boiling heat transfer - (터보 냉동기용 핀 튜브에 관한 연구(II) - 비등 열전달에 관하여 -)

  • Han, Kyu-Il;Kim, Si-Young;Cho, Dong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.5 no.2
    • /
    • pp.119-127
    • /
    • 1993
  • This work studies for heat transfer and pressure drop performance of integral inner and outer fin tubes, designed to enhance the heat transfer performance of smooth tubes for in recipro and turbo refrigerator or high performance compact heat exchangers. Eight different inner spiral fin copper tubes with integral fin at outside surfaces were employed to improve boiling heat transfer coeffcient. For comparison, tests were made using a plain tube having the inside diameter and an outside diameter equal to that at the root of the fins for the finned tubes. Pool boiling heat transfer is investigated experimentally and theoretically on single tube arrangement. The refrigerant evaporates at a saturation state of 1 bar on the outside tube surface heated by hot water. The refrigerant R11 ($CFCl_3$) was used at a pressure of $P_s=1bar$ as a convenient test fluid with a boiling temperature of $T_s=23.6^{\circ}C$. The observed heat transfer enhancement of boiling for finned tubes significantly exceeded that to be expected on grounds of increased area. The maximum Vapor - side enhancement(i.e., vapor - side heat transfer coefficient of finned tube/vapor - side coefficient for plain tube) was found to be around 4 at 1299fpm - 30grooves tube.

  • PDF

Spatial and Temporal Variations of δ13C and C/N in Suspended Particulate Organic Matter in the Gangneung Namdae Stream, Korea (강릉 남대천 부유입자유기물의 탄소안정동위원소 비와 C/N 비의 시·공간 변동)

  • Kwak, Jung Hyun;Park, Hyun Je
    • Journal of Environmental Science International
    • /
    • v.29 no.5
    • /
    • pp.531-539
    • /
    • 2020
  • To understand the composition, quantity, and quality of Suspended Particulate Organic Matter (SPOM) in the Gangneung Namdae Stream, Korea, we examined spatiotemporal variations in water temperature, salinity, chlorophlly a (Chl a), Particulate Organic Carbon (POC) and nitrogen (PON), and carbon stable isotope (δ13C) of SPOM at six stations in June (pre-monsoon), July (monsoon), and September (post-monsoon) 2017. With increasing precipitation, the average POC and C/N values increased significantly in July than in June. In September, the values decreased with decreasing precipitation. The δ13C values showed irregular spatiotemporal fluctuations among the stations and periods, thereby suggesting a greater contribution of autochthonous organic matter to the pool of SPOM than that of allochthonous organic matter derived from upstream. In addition, the large and irregular changes in POC, C/N ratio, C:Chl a, and δ13C compared to that of PON were observed for all periods among the stations, indicating a serial discontinuity of the stream. Our results suggest that the Gangneung Namdae Stream is significantly influenced by the increase in freshwater discharge caused by heavy rainfalls during the summer monsoon and post-monsoon periods.

Flow Analysis for Fission Moly Target Cooling in HANARO (하나로 Fission Moly 표적 냉각에 대한 유동해석)

  • Park, Yong-Chul
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.502-507
    • /
    • 2003
  • The HANARO, multi-purpose research reactor, 30 MWth open-tank-in-pool type, is under normal operation since it reached the initial critical in February 1995. The HANARO is used for fuel performance tests, radio isotope productions, reactor material performance tests, silicone semiconductor productions and etc. Specially, the HANARO is planning to produce a fission moly-99 of radio isotopes, a mother nuclide of Tc-99m, a medical isotope and is under developing a target handling tool for loading and unloading those at a flow tube (OR-5). The target should be sufficiently cooled in the flow tube without an interference with the cooling of the others and an induction of extremely vibration. This topic is described an analectic analysis for the cooling characteristics of the fission moly-99 target to find the minimum cooling water. It was confirmed through the analysis results that the minimum cooling water, about 2.717 kg/s flew through the flow tube under the worst case that the guide tube got no perforating holes for cooling water to pass through the holes and that the target was safely cooled under about seventy percent (70%) of the maximum allowable temperature of the target.

  • PDF

Extinguishing Characteristics of Zeolite adsorbed Dry Chemical Powder (분말 소화약제가 흡착된 제올라이트의 소화 특성)

  • Shin, Changsub;Park, Hojun
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.6
    • /
    • pp.59-63
    • /
    • 2012
  • The use of dry chemical powder has been increased as it can be stored for a long period and sustain in stable condition compared to gas or liquid phase extinguishing agents. A new type of dry chemical powder using Zeolite was produced in the research. Chemical powder was adsorbed into Zeolite 13X, a porous material appearing negative catalytic effect, to create extinguishing powder obtaining core shell structure and measured physical properties and run a small scale fire extinguishment. SEM, XRD, TA analysis was also executed, and extinguishing characteristics were measured by fire extinguishing experiment on oil pool fire. The experiment showed that the average particle size of Zeolite 13X was equivalent, indicating about $3{\pm}1{\mu}m$ and thermal analysis result illustrated that Zeolite 13X showed exothermic reaction peaks at $900^{\circ}C$ due to solid-state transformation. Extinguishing characteristics on oil fire of $NaHCO_3$/Zeolite 13X and $NH_4H_2PO_4$/Zeolite were improved, influenced by adsorbed extinguishing powders on Zeolite 13X and Zeolite 13X that contains high phase transition temperature.