• Title/Summary/Keyword: Polyurethane membrane

검색결과 72건 처리시간 0.022초

항균 특성을 위한 나노구조 유연 필름의 제작 및 평가 (Fabrication and Assessment of Flexible Nanostructured Film for Antibacterial Properties)

  • 박현하
    • 한국기계가공학회지
    • /
    • 제21권5호
    • /
    • pp.105-109
    • /
    • 2022
  • In the field of medical and marine industries, antibacterial surfaces have been emerged as one of the most important issues. Recently, many researchers have been studying antibacterial surfaces to kill bacteria or prevent the adhesion of bacteria. In their researches, various materials and structures are suggested to inhibit the adhesion of bacteria or kill the attached bacteria. However, chemical materials such as antibiotics or metal could be toxic. Moreover, frequent use of antibiotics causes super bacteria having resistance to antibiotics. In this study, nano-pillar structured surface was fabricated using polyurethane acrylate (PUA) and the mechanically induced antibacterial function was confirmed based on the fabricated nanostructures. Nanostructures can damage the bacterial membrane of Gram-negative bacteria through stretching of bacterial membrane via interaction with the nanostructures and the bacterial membrane. Consequently, the proposed transparent, flexible and nanostructured PUA films can be one of promising candidates for antifouling and antibacterial surfaces which can be applied in various industries.

Effect of Surfactants on the Electrochemical Performance of Cation-Selective Membrane Electrodes

  • Oh, Hyun-Joon;Cha, Geun-Sig;Nam, Hak-hyun
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권1호
    • /
    • pp.37-44
    • /
    • 2003
  • We examined the effect of polyether-type nonionic surfactants (Brij 35, Triton X-100, Tween 20 and Tween 80) on the potentiometric properties of sodium-, potassium- and calcium-selective membranes which are prepared with widely used ionophores and four kinds of polymer matrices [poly(vinyl chloride) (PVC), polyurethane (PU), PVC/PU blend, and silicone rubber (SR)]. It was found that the PVC-based membranes, which provide the best performance among all other matrix-based membranes in the absence of nonionic surfactants, exhibited larger change in their potentiometric properties when nonionic surfactants are added to the sample solution. On the other hand, the sodium-selective SR-based membrane with calix[4]arene, potassium-selective PVC/PU- or SR-based membrane with valinomycin, and the calcium-selective SR-based membrane with ETH 1001 provide almost identical analytical performance in the presence and absence of Tween 20 or Tween 80 surfactants. The origin of nonionic surfactants effect was also investigated by interpreting the experimental results obtained with various matrices and ionophores. The results suggest that the nonionic surfactant extracted into the membrane phase unselectively form complexes with the primary and interfering ions, resulting in increased background potential and lower binding ability for the ionophore. Such effects should result in deteriorated detection limits, reduced response slopes and lower selectivity for the primary ions.

HFC계 발포제를 사용한 LNG 저장탱크용 폴리우레탄 폼 단열재의 특성 (Characteristics of Rigid Polyurethane Foams Blown by HFCs for LNG Storage Tank)

  • 이영범;최성희;최건형
    • 한국가스학회지
    • /
    • 제9권1호
    • /
    • pp.16-20
    • /
    • 2005
  • LNG저장탱크용 경질 폴리우레탄 폼의 발포에 많이 사용되어온 것은 CFC-11이었으며 현재 사용되고 있는 것은 HCFC-l4lb이다. 하지만 CFC-11과 이의 대안으로 사용되고 있는 HCFC-l4lb는 성층권에 존재하는 오존층(ozone layer)을 파괴하기 때문에, 선진국의 경우 CFC-11은 1996년부터 사용이 금지되어 왔으며 HCFC-141b도 2005년부터 사용이 금지될 예정이다. 이러한 국제적 제약으로 인해 이들 발포제를 대체할 차세대 발포제와 이를 이용한 폴리우레탄 폼에 대한 연구가 활발히 진행되고 있다. 본 논문에서는 HFC계 발포제를 사용하여 합성한 경질폴리우레탄 폼의 물리적, 기계적 특성을 측정하였으며 이 결과를 HCFC-l4lb를 사용하여 합성한 경질폴리우레탄 폼의 특성과 비교하였으며 이로부터 LNG저장탱크용 단열재에 있어서 HFC계 발포제의 HCFC-l4lb대체가능성에 대하여 검토하였다.

  • PDF

PU/PDMS 막을 이용한 증기투과공정에 의한 물로부터 휘발성 유기화합물 제거 (Removal of VOCs from Water by Vapor Permeation through PU/PDMS Membrane)

  • 임지원;남상용;김영진;천세원
    • 멤브레인
    • /
    • 제14권2호
    • /
    • pp.157-165
    • /
    • 2004
  • 막을 이용한 증기투과는 유기용제 및 휘발성 유기화합물의 제거와 관련되는 환경문제와 결부되어 활발한 연구가 진행되고 있다. 막을 이용한 휘발성 유기화합물 증기의 분리는 막 재질은 높은 온도에도 견딜 수 있어야 하고 증기에 대한 화학적 저항성도 매우 좋아야 한다. 증기투과에 가장 널리 쓰이고 있는 PDMS (polydimethylsiloxane)의 단점을 보완하기 위해 본 연구에서는 4,4'-diphenylmethane diisocyanate (MDI), PDMS 소프트 세그먼트를 기초로 한 polyurethane-polysiloxanes (PU/PDMS)를 합성하고 그들의 증기투과 특성을 연구하였다 각 Feed에 대한 팽윤도는 톨루엔 > 1,2-이염화에탄 > 헥산 순으로 나타났다. Feed의 농도가 증가할수록 톨루엔과 1,2-이염화에탄의 flux는 점차 증가하는 경향을 나타내었지만, 헥산은 feed의 농도가 증가하여도 flux의 변화가 나타나지 않았다. PU/PDMS 막은 VOCs와 상대적으로 높은 친화도를 가지고 있기 때문에 permeate에서의 농도는 50% 전후로 일정하게 나타났다.

광화학적 방법으로 친수성막이 고정화된 생체 재료의 표면특성 분석 (The Surface Characteristics of Biomaterials Fixed with a Hydrophilic Membrane by Photochemical Reaction)

  • 김현정;전성민;이규백;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.11-15
    • /
    • 1997
  • We used the photoreactive poly(allylamie) (PPA) as the hydrophilic membrane to control the release of drug from polyurethane(PU). PPA was covalently bonded onto PU surface through the highly reactive nitrene intermediate upon UV light irradiation $(3.3mW/cm^2)$ at 254nm for 5min. Thus the release rate of rifampicin from PU surface was controlled. To know the characteristics of PU surface bonded with PPA, we measured the ATR-FTIR, ESCA, Static Contact Angle and SEM. From these, we suggest that PPA as a hydrophilic membrane is enable to control the release rate of a hydrophobic drug from polymer without the change of bulk property.

  • PDF

Freeze-dried bovine amniotic membrane as a cell delivery scaffold in a porcine model of radiation-induced chronic wounds

  • Oh, Daemyung;Son, Daegu;Kim, Jinhee;Kwon, Sun-Young
    • Archives of Plastic Surgery
    • /
    • 제48권4호
    • /
    • pp.448-456
    • /
    • 2021
  • Background Locoregional stem cell delivery is very important for increasing the efficiency of cell therapy. Amnisite BA (Amnisite) is a freeze-dried amniotic membrane harvested from bovine placenta. The objective of this study was to investigate the retention of cells of the stromal vascular fraction (SVF) on Amnisite and to determine the effects of cell-loaded Amnisite in a porcine radiation-induced chronic wound model. Methods Initially, experiments were conducted to find the most suitable hydration and incubation conditions for the attachment of SVF cells extracted from pig fat to Amnisite. Before seeding, SVFs were labeled with PKH67. The SVF cell-loaded Amnisite (group S), Amnisite only (group A), and polyurethane foam (group C) were applied to treat radiation-induced chronic wounds in a porcine model. Biopsy was performed at 10, 14, and 21 days post-operation for histological analysis. Results Retaining the SVF on Amnisite required 30 minutes for hydration and 1 hour for incubation. A PKH67 fluorescence study showed that Amnisite successfully delivered the SVF to the wounds. In histological analysis, group S showed increased re-epithelialization and revascularization with decreased inflammation at 10 days post-operation. Conclusions SVFs had acceptable adherence on hydrated Amnisite, with successful cell delivery to a radiation-induced chronic wound model.

Silicone Rubber Blended with Polyurethane as the Matrix for Ion-Selective Membrane Electrodes

  • Lee, Hyun Jung;Rho, Kyung Lae;Kim, Chang Yong;Oh, Bong Kyun;Cha, Geun Sig;Nam, Hakhyun
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.623-630
    • /
    • 1995
  • Silicone rubber-based sodium-selective membranes are developed for solid-state ion sensors. It was shown that the potetiometric performance of SR-based membranes are greatly dependent on the type of neutral carriers employed; among the three ionophores, N,N,N',N'-tetracyclohexyl-1,2-phenylenedioxydiacetamide (ETH 2120), bis[(12-crown-4)methyl]dodecylmethylmalonate (D12C4DMM) and monensin methyl ester (MME), examined, only ETH 2120 was compatible with the SR-based matrix. Addition of about 20 wt% plasticizer to the SR-based matrix provided the resulting membranes with potentiometric properties essentially equivalent to those of the corresponding PVC-based membranes. Owing to the strong adhesive strength of SR-based membranes, the CWEs coated \vith those membranes exhibited long lifetime with conventional electrode-like performance. Blending of PU into the SR matrix increased the lifetime of CWEs from two weeks to one month.

  • PDF

양이온성 폴리카보네이트-폴리우레탄의 합성과 분리특성 (Synthesis and Permeability of Cationic Polycarbonate-Polyurethane)

  • 이상우;오부근;이영무;노시태;김계용
    • 공업화학
    • /
    • 제1권1호
    • /
    • pp.52-62
    • /
    • 1990
  • 폴리카보네이트 폴리올, MDI 및 N-methyldiethanolamine(MDEA)로부터 폴리카보네이트형 우레탄 수지를 합성하고, MDEA의 4차 암모늄염화 반응에 의해서 양이온성 폴리카보네이트 우레탄 수지를 제조하였다. 우레탄 연쇄내 이온기의 함량이 증가함에 따라 인장강도 탄성율은 현저하게 증가되었으나 내가수분해성등은 저하되는 경향을 표시하였다. 에탄올/물 혼합용액 분리실험에서 양이온성 폴리카보네이트형 우레탄 막의 선택도는 20정도였으며, 이때의 분리기구는 carrier mediated transport mechanism을 따른 것으로 생각된다.

  • PDF

카보네이트형 폴리우레탄막을 이용한 에탄올 수용액의 투과증발분리 III. 양쪽이온성기에 의한 영향 (Pervaporation Separation of Ethanol Aqueous Solution through Carbonate-type Polyurethane Membrane III. The Effect of Zwitterionic Group)

  • 오부근;이영무;노시태
    • 공업화학
    • /
    • 제3권4호
    • /
    • pp.605-613
    • /
    • 1992
  • 분자량이 1,000과 2,000인 카보네이트형 폴리올(PTMCG)을 사용하여 MDI와 사슬 연장제인 N-methyldielhanolamine을 반응시켜 NCO-말단 프레폴리머를 합성한 후 이온화제로 1,3-propane sultone을 반응시켜 양쪽이온성 작용기를 갖는 카보네이트형 폴리우레탄(ZPU)을 합성하였다. 모델반응의 IR과 NMR 스펙트럼으로부터 동일한 조건하에서 이혼화가 잘 일어나고 있음을 알 수 있어, 양쪽이온성 카보네이트형 폴리우레탄의 구조를 확인할 수 있었다. 열적성질을 측정한 결과 유리전이온도(Tg)는 $-15{\sim}-30^{\circ}C$ 범위로써 분자량이 1,000인 폴리올을 사용한 경우 $-15{\sim}-18^{\circ}C$, 분자량이 2,000인 폴리올을 사용한 경우 $-25{\sim}-26^{\circ}C$임을 알 수 있었다. 기계적 성질을 측정한 결과 인장강도는 분자량이 1,000과 2,000인 폴리올 모두 다 이온함량에 따라 크게 증가되나 이온 함량의 몰비율이 4.0 이상에서는 오히려 감소함을 알 수 있었다. 신장율은 인장강도와 달리 이온함량에 따라 오히려 감소함을 알 수 있었다. 이러한 물성측정의 결과로부터 인장강도가 우수하고, 연신율이 크지 않은 ZPU10-30을 택하여, 투과증발법을 이용한 에탄올 수용액농축에 응용하였다. 보다 우수한 선택도를 얻기 위하여 hexamethylene diisocyanate(HMDI)를 이용하여 가교막을 제조하였다. 팽윤도 실험결과 50wt% 에탄올농도 근처에서 증가하는 경향을 나타내었는데, 이는 에탄올에 의한 가소화효과의 영향이라고 생각된다. 분리성능을 최적화하기 위해 공급액 농도변화와 온도변화를 실시하였다. 전반적인 투과증발분리 성능은 선택도 2~83.2 및 투과유량 $25.4{\sim}58.8g/m^2hr$를 갖는 것으로 나타났다.

  • PDF