• Title/Summary/Keyword: Polyurethane Resin

Search Result 187, Processing Time 0.026 seconds

Preparation of Waterborne Polyurethanes Containing Polycarbonate Component and Their Applications to the Impregnation Finishing for Artificial Leathers (폴리카보네이트 성분을 포함하는 수분산 폴리우레탄의 제조와 인공피혁 함침가공에의 응용)

  • Lee, Kyoung-Woo;Ko, Jae-Hoon;Shim, Jae-Yun;Kim, Young-Ho
    • Polymer(Korea)
    • /
    • v.33 no.2
    • /
    • pp.175-182
    • /
    • 2009
  • Waterborne polyurethanes (WPUs) based on isophorone diisocyanate and mixed polyols of poly(tetramethylene glycol) (PTMG)/polycarbonate diol (PCD) were synthesized. The variation of mechanical and dyeing properties and alkali resistance of the WPU films were analyzed according to the polycarbonate (PC) content. The tensile strength of the films increased and the elongation at break decreased with the PC content in the WPU film. The incorporation of PC component in the WPU film did not affect the alkaline hydrolysis behavior. The synthesized WPU solutions were used as impregnating resins for the production of PET artificial leathers. The prepared WPU resins showed the good color fastness to washing, rubbing, and light of the artificial leather fabrics. The improvement of the properties became greater with the PC content in the WPU resin.

A Study on Migration of Monomers from Kitchen Utensils Including PA, PU, ABS, and Acrylic Resin Plastics (폴리아마이드제 등 조리기구 중 모노머의 이행에 관한 연구)

  • Choi, Jae-Chon;Park, Se-Jong;Park, Geon-Woo;Min, Hye-Kyoung;Yang, Ji-Young;Kim, Meehye
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.1
    • /
    • pp.81-86
    • /
    • 2015
  • The purpose of our paper was to investigate the migration level of 4,4'-MDA(4,4'-methylenedianiline), 2,4-TDA(2,4-toluenediamine), aniline, acrylonitrile and methylmeth acrylate from plastic cookwares into food simulants and to evaluate the safety of each monomers. The test articles for monomers were PA (polyamide) items for 4,4'-MDA, 2,4-TDA and aniline, PU (polyurethane) items for 4,4'-MDA, ABS (acrylonitrile-butadiene- styrene) items for acrylonitrile, and acrylic resin items for methylmethacrylate. All the article samples of 321 intended for contact with foods were purchased in domestic market. 4,4'-MDA, 2,4-TDA and aniline were analyzed by LC-MS/MS (liquid chromatography -tandem mass spectrometer), acrylonitrile by GC-NPD (gas chromatography-nitrogen phos phorus detector) and methyl methacrylate by GC-FID (gas chromatography-flame ionization detector). The migration level of monomers were within the migration limits of Ministry of Food and Drug Safety (MFDS). As a result of safety evaluation, our results showed that the estimated daily intake (EDI, mg/kg bw/day)s were $2.39{\times}10^{-9}$ and $1.20{\times}10^{-9}$ for 4,4'-MDA and 2,4-TDA of PA, $4.32{\times}10^{-9}$ for acrylonitrile of ABS and $2.27{\times}10^{-7}$ for methylmethacrylate of acrylic resin. Reference Dose (RfD, mg/kg bw/day) of acrylonitrile and tolerable daily intake (TDI, mg/kg bw/day) of methacrylate were established respectively as 0.001 by EPA (US Environmental Protection Agency) and as 1.2 by WHO (World Health Organization). When comparing with RfD and TDI, the EDIs of acrylonitrile and methylmethacrylate accounted for $4.32{\times}10^{-4}%$ and $1.89{\times}10^{-5}%$ respectively.

Adhesive Strength in Tension of SBR-Modified Cement Mortar with Self-Flowability Material for Floor-Finishing (자기 평활성 바닥 마감용 SBR 시멘트 모르타르의 인장부착강도)

  • Do, Jeong-Yun;Soh, Yang-Seob
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.4
    • /
    • pp.549-556
    • /
    • 2003
  • Various researches on the application of polymer dispersions to the cement mortar and concrete have been practised in many countries like America, Japan and Germany and so on because of high performance and good modification effect of these. In this study, SBR, Polymer dispersion that widely used in situ is employed that the self-flowability may be induced in the cemen mortar. In order to comprehend and investigate the modification of cement mortar with self-flowability by SBR and properties and fracture mode of adhesive strength in tension of that, experimental parameter was set as SBR solid-Cement ratio(S/C) and Cement:Fine aggregate(C:F) and the experiments such as Unit weight, Flow, Consistency change, Crack resistance and Segregation that inform on the general properties have been done. In addition of that, Adhesion in tension is measured with a view to comprehending the properties and fracture mode in tensile load. Consistency change of cement mortar modified by SBR did grow better as the ratio of SBR solid-Cement increased and was much superior to that of resin based flooring such as polyurethane and epoxy which recorded the loss of consistency in 90min. after mixing. Adhesive strength in tension increased with continuity in the curing age and showed the maximum in case of C:F=1:1 and S/C=20%. As the increase of curing age, the fracture mainly happened in the concrete substrate and the interface between the specimen and concrete substrate.

A study on the Manufacture and Application of UV-Cured Anti-stain Coating Compounds for PVC Tile (PVC 바닥상재용 광경화형 내오염 코팅액의 제조 및 응용에 관한 연구)

  • Yoon, Hyun-Jung;Ha, Jin-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.5
    • /
    • pp.1741-1746
    • /
    • 2010
  • This study is on development of UV-cured anti-stain coating compounds which have more improved anti-stain function to prevent a surface of PVC tile from stain. To make an anti-stain coating composition, water soluble antistatic agent made from ammonium(IV) salt, antistatic agents for acrylic and polyurethane were used. Their contents varied from 5 to 20wt% against quantities of resin in coating composition. After coating PVC tiles using bar-coating method that can adjust a thickness, we estimated surface properties of coated layer such as anti-stain, electric resistance, adhesive power, thickness of coating, and so on. Results showed that a coating composition added 15wt% of water soluble antistatic agent and coated with No.12 bar-coater had the optimum surface property in electric resistance($3.24{\times}10^9{\Omega}/cm^2$), anti-stain(ink Test, Dust Test) and adhesive power. We could also find electric resistance and anti-stain effect were improved as antistatic agent content increased. However, excessive addition of antistatic agents(over 20wt%) caused the migration.

Understanding Interfacial Charge Transfer Nonlinearly Boosted by Localized States Coupling in Organic Transistors (Carbon Nano Tube 및 산화그래핀을 첨가한 폴리우레아 복합재 제조 및 그 화학적 특성 분석)

  • Kim, Hyeongtae;Lee, Jihyun;An, Woo-Jin;Park, Jun Hong
    • Journal of Adhesion and Interface
    • /
    • v.22 no.4
    • /
    • pp.136-143
    • /
    • 2021
  • Polyurea has been investigated as a polymer matrix for composite materials because of its high mechanical strength. Although polyurea has a similar chemical structure to polyurethane, it has much higher strength and durability. In this study, the fabrication of polyurea composites reinforced with carbon nanotube (CNT) and graphene oxide (GO) is demonstrated to enhance the tensile strength of the glass fibers composite. Using FTIR and Raman spectroscopies, the chemical structures of polyurea, CNT, and GO are investigated. As a result, spectroscopy analysis reveals that the chemical structure of CNT, GO, and polyurea is maintained during the fabrication of the composite structure. Scanning electron microscopy reveals the uniform distribution of CNT and GO across the polyurea matrix. The reinforcement of 1 wt% CNT in polyurea enhances the tensile strength of CNT/polyurea composites. In contrast, the reinforcement of GO in polyurea induces the degradation of the tensile strength of GO/polyurea composites.

Development of a New Cardiac and Torso Phantom for Verifying the Accuracy of Myocardial Perfusion SPECT (심근관류 SPECT 검사의 정확도 검증을 위한 새로운 심장.흉부 팬텀의 개발)

  • Yamamoto, Tomoaki;Kim, Jung-Min;Lee, Ki-Sung;Takayama, Teruhiko;Kitahara, Tadashi
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.389-399
    • /
    • 2008
  • Corrections of attenuation, scatter and resolution are important in order to improve the accuracy of single photon emission computed tomography (SPECT) image reconstruction. Especially, the heart movement by respiration and beating cause the errors in the corrections. Myocardial phantom is used to verify the correction methods, but there are many different parts in the current phantoms in actual human body. Therefore the results using a phantom are often considered apart from the clinical data. We developed a new phantom that implements the human body structure around the thorax more faithfully. The new phantom has the small mediastinum which can simulate the structure in which the lung adjoins anterior, lateral and apex of myocardium. The container was made of acrylic and water-equivalent material was used for mediastinum. In addition, solidified polyurethane foam in epoxy resin was used for lung. Five different sizes of myocardium were developed for the quantitative gated SPECT (QGS). The septa of all different cardiac phantoms were designed so that they can be located at the same position. The proposed phantom was attached with liver and gallbladder, the adjustment was respectively possible for the height of them. The volumes of five cardiac ventricles were 150.0, 137.3, 83.1, 42.7 and 38.6ml respectively. The SPECT were performed for the new phantom, and the differences between the images were examined after the correction methods were applied. The three-dimensional tomography of myocardium was well reconstructed, and the subjective evaluations were done to show the difference among the various corrections. We developed the new cardiac and torso phantom, and the difference of various corrections was shown on SPECT images and QGS results.

  • PDF

The Application of 3D Bolus with Neck in the Treatment of Hypopharynx Cancer in VMAT (Hypopharynx Cancer의 VMAT 치료 시 Neck 3D Bolus 적용에 대한 유용성 평가)

  • An, Ye Chan;Kim, Jin Man;Kim, Chan Yang;Kim, Jong Sik;Park, Yong Chul
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.41-52
    • /
    • 2020
  • Purpose: To find out the dosimetric usefulness, setup reproducibility and efficiency of applying 3D Bolus by comparing two treatment plans in which Commercial Bolus and 3D Bolus produced by 3D Printing Technology were applied to the neck during VMAT treatment of Hypopahrynx Cancer to evaluate the clinical applicability. Materials and Methods: Based on the CT image of the RANDO phantom to which CB was applied, 3D Bolus were fabricated in the same form. 3D Bolus was printed with a polyurethane acrylate resin with a density of 1.2g/㎤ through the SLA technique using OMG SLA 660 Printer and MaterializeMagics software. Based on two CT images using CB and 3D Bolus, a treatment plan was established assuming VMAT treatment of Hypopharynx Cancer. CBCT images were obtained for each of the two established treatment plans 18 times, and the treatment efficiency was evaluated by measuring the setup time each time. Based on the obtained CBCT image, the adaptive plan was performed through Pinnacle, a computerized treatment planning system, to evaluate target, normal organ dose evaluation, and changes in bolus volume. Results: The setup time for each treatment plan was reduced by an average of 28 sec in the 3D Bolus treatment plan compared to the CB treatment plan. The Bolus Volume change during the pretreatment period was 86.1±2.70㎤ in 83.9㎤ of CB Initial Plan and 99.8±0.46㎤ in 92.2㎤ of 3D Bolus Initial Plan. The change in CTV Min Value was 167.4±19.38cGy in CB Initial Plan 191.6cGy and 149.5±18.27cGy in 3D Bolus Initial Plan 167.3cGy. The change in CTV Mean Value was 228.3±0.38cGy in CB Initial Plan 227.1cGy and 227.7±0.30cGy in 3D Bolus Initial Plan 225.9cGy. The change in PTV Min Value was 74.9±19.47cGy in CB Initial Plan 128.5cGy and 83.2±12.92cGy in 3D Bolus Initial Plan 139.9cGy. The change in PTV Mean Value was 226.2±0.83cGy in CB Initial Plan 225.4cGy and 225.8±0.33cGy in 3D Bolus Initial Plan 224.1cGy. The maximum value for the normal organ spinal cord was the same as 135.6cGy on average each time. Conclusion: From the experimental results of this paper, it was found that the application of 3D Bolus to the irregular body surface is more dosimetrically useful than the application of Commercial Bolus, and the setup reproducibility and efficiency are excellent. If further case studies along with research on the diversity of 3D printing materials are conducted in the future, the application of 3D Bolus in the field of radiation therapy is expected to proceed more actively.