• 제목/요약/키워드: Polytetrafluoroethylene (PTFE)

검색결과 190건 처리시간 0.026초

비침습적인 전기자극이 임프란트의 골융합에 미치는 영향;토끼경골에서의 조직계측학적 평가 (Effects of noninvasive electrical stimulation on osseointegration of endosseous implants;A histomorphometric evaluation in the rabbit tibia)

  • 손성배;박진우;서조영
    • Journal of Periodontal and Implant Science
    • /
    • 제35권3호
    • /
    • pp.635-648
    • /
    • 2005
  • The procedure that enhances osteogenesis and shortens the healing period is required for successful implant therapy. It has been introduced that osteogenesis is enhanced by the generation of electric field. Many researchers have demonstrated that application of electric and electromagnetic field promote bone formation. It also has been shown that electrical stimulation enhances peri-implant bone formation. Recently, several investigators have reported that noninvasive electrical stimulation using negatively charged electret such as polytetrafluoroethylene(PTFE) promotes osteogenesis. Therefore, we were interested in the effect of noninvasive electrical stimulation using negatively charged electret on the periimplant bone healing. After titanium implant were installed in the proximal tibial metaphysis of New Zealand white rabbit, negatively charged PTFE membrane fabricated by corana dischage was inserted into the inner hole of the experimental implant and noncharged membrane was applied into control implant. After 4 weeks of healing, histomorphometric analysis was performed to evaluate peri-implant bone response. The histomorphometric evaluations demonstrated experimental implant tended to have higher values in the total bone-to-implant contact ratio(experimental ; $49.9{\pm}13.52%$ vs control ; $37.5{\pm}19.44%$) , the marrow bone contact ratio(experimental ; $34.94{\pm}13.32%$ vs control ; $24.15{\pm}13.69%$), amount of newly formed bone in the endosteal region(experimental ; $1.00{\pm}0.30mm$ vs control ; $0.61{\pm}0.24mm$) and bone area in the medullary canal(experimental ; $13.55{\pm}4.98%$ vs control ; $9.03{\pm}3.05%$). The mean values of the amount of newly formed bone(endosteal region) and bone area(medullary canal) of the experimental implant demonstrated a statistically significant difference as compared to the control implant(p<0.05). In conclusion, noninvasive electrical stimulation using negatively charged electret effectively promoted peri-implant new bone formation in this study. This method is expected to be used as one of the useful electrical stimulation for enhancing bone healing response in the implant therapy

지표면 화학물질 측정을 위한 라만분광장치 (Raman Spectromter for Detection of Chemicals on a Road)

  • 하연철;이재환;고영진;이서경;김윤기
    • 한국광학회지
    • /
    • 제28권3호
    • /
    • pp.116-121
    • /
    • 2017
  • 본 연구에서는 오염된 지표면의 화학물질을 탐지하기 위해 라만 라이다 기반의 지표면 화학물질 탐지 시스템을 설계하고 제작하였다. 화학물질에 레이저를 조사하였을 때 나오는 라만 산란광을 측정하여 측정 시료의 분광정보를 얻는 라만 라이다 시스템은 측정 시료의 라만 산란광을 유도하는 레이저를 포함한 송광부와 라만 산란광을 수광하는 수광부, 수광된 광을 파장별로 나눠주는 분광부로 구성된다. 측정거리가 변하여도 수광부에 의해 집광되는 광이 동일한 위치에 집속되도록 code V 시뮬레이터를 사용하여 광학계를 설계하였다. 총 12종의 화학물질이 유리와 콘크리트 위에 있을 때 라만 스펙트럼을 측정하여 비교한 결과 라만 스펙트럼의 특성이 유사하지만, 세기에 차이가 있는 것을 관찰하였다. 고체 시료인 PTFE (polytetra-fluoroethylene)를 사용하여 시스템과의 거리 변화에 따른 라만 스펙트럼의 세기를 비교한 결과 시뮬레이션에서 얻은 거리에 따른 수광 효율과 유사한 것을 확인하였다. 결론적으로 본 시스템을 이용하여 다양한 거리에서도 화학물질의 라만 스펙트럼 측정이 가능함을 확인하였다.

음이온교환막 연료전지 응용을 위한 UV 중합법을 이용한 세공 충진 음이온교환막 개발 (Development of Pore Filled Anion Exchange Membrane Using UV Polymerization Method for Anion Exchange Membrane Fuel Cell Application)

  • 곽가진;김도형;남상용
    • 멤브레인
    • /
    • 제33권2호
    • /
    • pp.77-86
    • /
    • 2023
  • 본 연구에서는 낮은 막 저항과 높은 수산화 이온 전도성을 가지는 세공 충진 이온교환막 제조법으로 연구하였다. 알칼리 내구성을 향상하기 위해 폴리 테트라 플로오 에틸렌 소재인 다공성 지지체를 사용하였고 세공에는 단량체 2-(dimethylamino)ethyl methacrylate (DMAEMA), vinylbenzyl chloride (VBC)를 이용하여 copolymer를 제조했다. 가교제는 divinylbenzene (DVB)를 사용하였고 가교제 함량별로 이온교환막을 제조하여 DMAEMA-DVB와 VBC-DMAEMA-DVB copolymer에서 가교제 함량이 미치는 영향에 관해 연구하였다. 그 결과, PTFE 소재 지지체를 이용하여 화학적 안정성이 향상했고 저압 UV 램프를 사용하여 낮은 온도에서 빠른 광중합이 가능하여 생산성을 높일 수 있는 장점이 있다. 음이온교환 막 연료전지에 요구되는 이온교환막의 물리적 및 화학적 안정성을 확인하기 위해서 인장강도와 내알칼리성 테스트를 진행하였다. 그 결과, 가교도가 증가할수록 인장강도 대략 40 MPa가 증가하였고, 최종적으로 이온전도도와 내알칼리성 테스트를 통해 가교제 함량이 증가할수록 알칼리 안정성이 증가하는 것을 확인하였다.

고속역류크로마토그래피 기술을 이용한 생리활성 물질의 분리 및 정제 (Isolation and Purification of Bioactive Materials Using High-Performance Counter-Current Chromatography (HPCCC))

  • 정동수;신현재
    • KSBB Journal
    • /
    • 제25권3호
    • /
    • pp.205-214
    • /
    • 2010
  • 역류크로마토그래피 (counter-current chromatography, CCC)는 일련의 분배과정을 한 개의 튜브 내에서 연속적으로 일어나도록 고안된 시스템으로서 컬럼으로는 polytetrafluoroethylene(PTFE) 튜브가 다층으로 감겨있는 원통형의 홀더 3개가 서로 기어를 통해 물려있으며, 홀더가 회전과 공전을 통해 튜브의 꼬임을 방지하는 rotary seal-free flow centrifuge 시스템으로 되어있다. 역상 HPLC (reverse phase HPLC)에서는 고정상이 실리카에 결합된 유기물단 (organic moiety)이 수용성 이동상 물질에 의해서 용매화 (solvated)되는 반면 CCC는 실리카 대신에 강한 중력장에 의해 분리되는 자유로운 용매가 고정상이 되며 이 고정상의 부피비율은 20-30%에 이른다. 즉 고체담체에 결합된 유기관능기 대신에 물과 섞이지 않는 hexane 같은 유기용제가 고정상으로 사용되는 것이다. 고속역류크로마토그래피 (high-performance countercurrent chromatography, HPCCC)는 CCC의 기능을 향상시킨 분리시스템으로서 높은 중력장하에서 높은 이동상 속도와 높은 분리효율과 짧은 분리시간을 특징으로 하고 있다. 특히 mg 단위에서 kg 단위로의 스케일업이 선형적으로 가능하다는 큰 장점을 지니고 있다. 이 총설에서는 현재까지 개발된 CCC의 일반적인 이론을 간략히 정리하고 최신 HPCCC 장비의 적용 예를 살펴보고 그 응용분야로서 생리활성물질의 분리 및 정제와 관련된 연구동향을 정리하였다.

고기능성 투습방수 소재의 저온굴곡 시험방법 개선 연구 (A Study on Improvement of the low temperature flex resistance test method about high waterproof materials)

  • 이민희;문선정;고혜지;홍성돈
    • 품질경영학회지
    • /
    • 제46권3호
    • /
    • pp.425-440
    • /
    • 2018
  • Purpose: This study is aimed at developing of the flex resistance testing process at low temperature with the waterproof fabric to suit the military environment, and is designed to fit for the purpose of the waterproof materials in order to optimize the test method by finding out matters to improve from existing the test method and through previous studies. Methods: The test method, which has been applied to flex resistance of existing water-repellent materials, was improved and consequently, differentiated test results could be obtained according to the test temperature, sample size, and flexing method. Results: The testing of the total of 8 samples revealed that performance of the military requirement could hardly be met just by presenting the materials or 2~3 layers when the quality criteria for high functional water repellent fabrics were applied. PTFE(Polytetrafluoroethylene) is preferred to PU(Polyurethane) to be used in the extremely low-temperature environment, but durability under the low-temperature environment may be varied depending on film thickness or laminating technique even if the materials of waterproof films are identical. Therefore, in addition to the material or texture, the test method capable of reflecting durability under the low-temperature environment shall be suggested, and the newly designed test method proposed in this study was shown to suggest differentiated quality criteria by the material. Conclusion: The water resistance measurement and the test method following flex resistance with expanded range of flex will enable the differentiable test of the samples according to the number of repetition. This study is meaningful in that it suggests a differentiable test method capable of establishing a basis of deciding suitable material when selecting military goods made of water repellent material by properly improving the test method.

Analysis and Exposure Assessment of Perchlorate in Korean Dairy Products with LC-MS/MS

  • Oh, Sung-Hee;Lee, Ji-Woo;Mandy, Pawlas;Oh, Jeong-Eun
    • Environmental Analysis Health and Toxicology
    • /
    • 제26권
    • /
    • pp.12.1-12.7
    • /
    • 2011
  • Objectives: Perchlorate is an emerging contaminant that is found everywhere, including various foods. Perchlorate is known to disturb the production of thyroid hormones and leads to mental disorders in fetuses and infants, as well as metabolic problems in adults. In this study, we attempted to establish an LC-MS/MS method for measuring perchlorate in dairy products and used this developed method to investigate perchlorate levels in Korean milk and yogurt samples. Methods: The developed method of perchlorate analysis requires a shaker and 1% acetic acid/acetonitrile as the extracting solvent. Briefly, the samples were extracted and then centrifuged (4000 rpm, 1hour), and the supernatant was then passed through a $Envi^{TM}$ Carb SPE cartridge that had been prewashed sequentially with 6 mL of acetonitrile and 6 mL of 1% acetic acid in water. The final volume of the sample extract was adjusted to 40 mL with reagent water and the final sample was filtered through a 0.20-${\mu}m$ pore size PTFE (Polytetrafluoroethylene) syringe filter prior to LC-MS/MS. Results: The average levels of perchlorate in milk and yogurt samples were $5.63{\pm}3.49\;{\mu}g/L$ and $3.65{\pm}2.42\;{\mu}g/L$, respectively. The perchlorate levels observed in milk samples in this study were similar to those reported from China, Japan, and the United States. Conclusions: The exposure of Koreans to perchlorate through the consumption of dairy products was calculated based on the results of this study. For all age groups, the calculated exposure to perchlorate was below the reference of dose (0.7 ${\mu}g/kg$-day) proposed by the National Academy of Science, USA, but the perchlorate exposure of children was higher than that of adults. Therefore, further investigation of perchlorate in other food samples is needed to enable a more exact assessment of exposure of children to perchlorate.

외기 온도 증가가 가스 포일 스러스트 베어링의 하중지지 성능과 표면 코팅에 미치는 영향 (Effects of Increasing Ambient Temperatures on the Static Load Performance and Surface Coating of a Gas Foil Thrust Bearing)

  • 조현우;김영우;권용범;김태호
    • Tribology and Lubricants
    • /
    • 제40권3호
    • /
    • pp.103-110
    • /
    • 2024
  • Gas foil thrust bearings (GFTBs) are oil-free self-acting hydrodynamic bearings that support axial loads with a low friction during airborne operation. They need solid lubricants to reduce dry-friction between the runner and top foil and minimize local wears on their surfaces during start-up and shutdown processes. In this study, we evaluate the lift-off speeds and load capacity performance of a GFTB with Polytetrafluoroethylene (PTFE) surface coating by measuring drag torques during a series of experimental tests at increasing ambient temperatures of 25, 75 and 110℃. An electric heat gun provides hot air to the test GFTB operating in the closed booth to increase the ambient temperature. Test results show that the increasing ambient temperature delays the lift-off speed and decreases the load capacity of the test GFTB. An early developed prediction tool well predicts the measured drag torques at 60 krpm. After all tests, post inspections of the surface coating of the top foil are conducted. Scanning electron microscope (SEM) images imply that abrasive wear and oxidation wear are dominant during the tests at 25℃ and 110℃, respectively. A quantitative energy dispersive spectroscopy (EDS) microanalysis reveals that the weight percentages of carbon, oxygen, and nitrogen decrease, while that of fluorine increases significantly during the highest-temperature tests. The study demonstrates that the increasing ambient temperature noticeably deteriorates the static performances and degrades the surface coating of the test GFTB.

다른 pH의 전해질에서 polyvinylidene chloride-resin와 polyvinylidene fluoride로부터 합성된 다공성 탄소의 전하 저장 거동 (Charge Storage Behavior of the Carbons Derived from Polyvinylidene Chloride-resin and Polyvinylidene Fluoride in Different pH Electrolytes)

  • 전상은
    • Composites Research
    • /
    • 제35권6호
    • /
    • pp.394-401
    • /
    • 2022
  • Polyvinylidene chloride-resin(PVDC-resin)와 polyvinylidene fluoride(PVDF)의 두 폴리머 전구체는 열분해 과정을 통해 마이크로 다공성 탄소로 변환되어 되므로 이온 흡/탈착으로 전하를 저장하는 슈퍼커패시터용 전극재료로 유리하다. 더욱이, 두 전구체를 구성하는 여러가지 이종원소들은 탄화 후 작용기를 형성하여 추가적인 전하저장에 기여할 수 있으므로, 탄화 시 생성되는 작용기에 대한 분석은 에너지 저장용 탄소소재를 개발하는데 중요하다. 본 연구에서는 두 폴리머 전구체를 탄화시킨 후 생성된 작용기를 X-선 광전자 분광법(X-ray photoelectron spectroscopy)과 다양한 pH의 전해질에서 탄소 전극의 전기화학 거동 관찰을 통하여 확인하였다. 산성(1 M H2SO4) 전해질에서 측정된 두 탄소 전극의 비전기용량은 생성된 quinone 작용기의 패러데익 충/방전 반응 덕분에 중성 전해질(0.5 M Na2SO4)에서보다 증가하였다. 특히, PVDC-resin으로부터 합성된 탄소는 매우 작은 마이크로 기공이 표면에 형성되어 있어 전해질 이온의 흡착을 어렵게 하므로, PVDF로부터 합성된 탄소 전극에 비해 낮은 용량을 보인다. 염기성 전해질(6 M KOH)에서 두 탄소 전극 모두 3가지 전해질 중 가장 높은 비전기용량이 측정되었는데, 이는 구성하는 전해질 이온들(K+, OH-)이 두 탄소에 형성된 마이크로 기공으로 흡/탈착이 용이하게 일어나는 동시에 패러데익 충/방전 반응으로 추가적인 전하가 저장되었기 때문이다.

동맥경화성 하지 동맥 폐색증에 대한 우회로 수술의 효과 (The Effect of a Bypass Operation for Atherosclerotic Arterial Obstructive Disease at the Lower Extremity)

  • 최원석;박재민;이양행;한일용;전희재;윤영철;황윤호;조광현
    • Journal of Chest Surgery
    • /
    • 제41권5호
    • /
    • pp.610-618
    • /
    • 2008
  • 배경: 동맥경화성 하지 동맥 폐색증의 치료는 보존적 운동 요법, 약물 요법, 수술 방법 등으로 증상의 완화 및 혈류 개선을 기대할 수 있는데 그 중 동맥간 우회로 수술이 가장 효과적이라고 알려져 있다. 본 연구는 본원에서 시행한 우회로 수술의 단기 추적 결과를 조사하여 그 효과를 평가하고 개존율에 영향을 미치는 인자를 분석하여 향후 치료의 지표로 삼고자 한다. 대상 및 방법: 2002년 6월에서 2006년 4월까지 본원 흉부외과에서 동맥경화성 하지 동맥 폐색증으로 진단받고 동맥간 우회로 수술을 받았던 환자 96명을 대상으로 하였다. 증상과 Ankle-brachial index (ABI)의 변화를 통해 우회로 수술의 효용성을 파악하고 수술 후 합병증, 하지 절단율 그리고 이식편 개존율 등을 통해 단기 결과를 확인하였다. 성별, 연령, 흡연 유무, 동반 질환, 문합 위치, 이식편의 크기와 종류 등의 항목으로 개존율에 미치는 위험인자를 확인하였다. 이외에 폐색 부위, 약 복용 등을 각 의무기록을 바탕으로 후향적으로 조사하였다. 전체 평균 추적 기간은 $29.4{\pm}13.1$개월이었다. 결과: 대상 환자들의 평균 연령은 $65.95{\pm}9.61$세로 남성이 88예였으며 허혈성 하지 통증이 가장 많은 증상이었다. 동반 질환으로는 고혈압(61%), 당뇨병(42%), 심장 질환(35%) 순이었고 흡연자는 88명(91.7%)이었다 동맥 폐색 부위 중 가장 많은 부위는 표재성 대퇴동맥으로 44예(40%) 이었다. 수술 방법 중 이식편으로 Polytetra-fluoroethylene (PTFE) 인조 혈관을 이용한 대퇴-슬와동맥간 우회로술을 가장 많이 시행하였으며 대복재정맥도 11예에서 사용하였다. ABI는 수술 전 $0.30{\pm}0.11$에서 수술 후 $0.63{\pm}0.11$으로 의미 있는 증가를 보였다(p<0.001). 수술 후 1년, 3년 이식편 개존율은 각각 86.4%, 68.0%이었다. 개존 실패를 보인 경우는 29예(30.21%)였으며 남성, 흡연 그리고 고혈압이 동반되어 있는 경우가 실패군에서 유의하게 높았고 이 중 고혈압이 위험인자로 유의한 결과를 보였다(p=0.042). 결론: 동맥경화성 하지 동맥 폐색증의 동맥간 우회로 수술은 하지 통증, 파행증의 호전과 하지 절단을 예방하는데 비교적 효과적인 치료 방법이다. 장기적인 이식편 개존율을 유지하기 위해서는 남성 흡연자의 금연을 적극 유도하고 고혈압 환자의 철저한 혈압 조절이 동반됨과 동시에 수술시 적절한 이식편의 선택, 규칙적인 약물 복용, 꾸준한 외래 추적관찰 등의 효과적인 관리가 필요할 것으로 사료된다.

GE $Advance^{TM}$ 양전자방출단층촬영기의 표준 성능평가 (Standard Performance Measurements of GE $Advance^{TM}$ Positron Emission Tomography)

  • 정하규;김희중;손혜경;봉정균;정해조;전태주;김재삼;이종두;유형식
    • 대한핵의학회지
    • /
    • 제35권2호
    • /
    • pp.100-112
    • /
    • 2001
  • 목적: 본 연구의 목적은 NEMA 프로토콜에 따라서 GE $Advance^{TM}$ PET 시스템의 성능을 평가하고 그러한 시스템이 나타낼 수 있는 능력과 한계점을 명확히 이해하는데 있다. 대상 및 방법: 성능평가는 $^{18}FDG$ 선상선윈 및 점선원 그리고 NEMA 팬텀을 사용하여 횡축방향 공간분해능, 축방향 공간분해능, 산란분획, 민감도, 계수율손실, 계수율보정, 산란보정, 균일도보정, 감쇠보정을 대상으로 하였다. 횡축방향 공간분해능과 축방향 공간분해능, 산란분획에서는 선상선원 및 점선원을 사용하여 각각 NEMA 프로토콜에 따라 정해진 위치로 이동시키면서 측정하였고, 산란분획 및 나머지 성능평가 검사에서는 직경 20 cm의 PMMA 재질의 팬텀을 이용하여 측정하였다. 결과: 표준영상 획득 모드에서 시행한 본 성능평가의 결과를 고민감도 모드 및 고분해능 모드에 대하여 얻었다. 고민감도 모드에서 동경방향으로 측정된 횡축방향 공간분해능은 스캐너 시야중심에서 4.8 mm, 20 cm에서 7.03 mm로 감소했으며 축방향 공간분해능은 스캐너 시야중심에서 평균 3.98 mm, 20 cm에서 6.71 mm로 감소하였다. 산란분획은 고민감도 모드에서 평균 9.87%였고, 민감도 측정의 결과는 고민감도 모드, 시스템 전체에 대해서 참동시계수율 $225.8kcps/{\mu}Ci/cc$를 얻었고 계수율손실 측정은 50%의 불응시간을 가지는 방사능 농도가 $4.6{\mu}Ci/cc$였으며 이때의 계수율은 427 kcps였다. 계수율 보정의 오차는 고민감도 모드, $4.60{\mu}Ci/cc$에서 최소 1.49%, 최대 3.83%였고, 산란보정의 오차는 고민감도 모드에서 평균 -0.95%였으며 균일도보정 측정은 영상면들 간의 비균일도가 최소 -1.25%, 최대 1.74%였고 변이계수는 0.74%였다. 감쇠보정의 오차는 공기에서 5.68%, 물 0.04%, 테플론 -6.51%를 얻었다. 결론: NEMA 프로토콜에 근거하여 본 연구에서 실시한 표준 성능 평가 검사는 모두 제조사의 시험지침서에 부합하였다. 결론적으로, 이는 본 GE $Advance^{TM}$ PET 시스템이 임상에의 적용에 적합함을 보여주었다.

  • PDF