• Title/Summary/Keyword: Polytetrafluoroethylene (PTFE)

Search Result 190, Processing Time 0.033 seconds

Right Ventricular Myxoma Obstructing Right Ventricular Outflow Tract (점액종에 의한 우심실 유출로 협착)

  • Song Kwang-Jae;Yun Tae-Jin
    • Journal of Chest Surgery
    • /
    • v.39 no.8 s.265
    • /
    • pp.637-639
    • /
    • 2006
  • Cardiac myxoma is the most common primary tumor of the heart, but right ventricular myxoma causing outflow obstruction is relatively rare. A 15 years old girl developed dyspnea on exertion and intermittent syncope caused by a right ventricular mass obstructing the right ventricle outflow tract. Transthoracic echocardiography revealed $3.6{\times}3.0\;cm$ sized pedunculated subpumonic mass originating from the right ventricular anterior free wall. The patient underwent an emergency operation, consisting of the removal of the mass by wide excision of the tumor base and PTFE (polytetrafluoroethylene) patching of the right ventricular anterior free wall defect. Pathological findings of the mass were compatible with myxoma, and the patient was discharged uneventfully 7 days after the operation.

Dielectric Properties of Ceramic/Polymer Composites at Microwave Frequencies

  • Kim, Eung-Su;Jeon, Chang-Jun
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.19.1-19.1
    • /
    • 2011
  • Effects of particle size, crystal structures and multilayer structures of $ATiO_3$, $ATa_2O_6$, $ANb_2O_6$, $AWO_4$, and $AMoO_4$ (A=Ni, Mg, Zn, Co) ceramic fillers on the dielectric properties of polystyrene (PS), polypropylene (PP) and polytetrafluoroethylene (PTFE) polymer matrices were investigated at microwave frequencies. The microwave dielectric properties of $ATiO_3$ (ilmenite), $ATa_2O_6$ (tri-rutile), $ANb_2O_6$ (columbite), AWO4 (wolframite), and AMoO4 (wolframite) ceramics were largely dependent on the structural characteristics of oxygen octahedra. The dielectric constant (K) of the composites was increased with the ceramic content. However, the dielectric loss (tan ${\delta}$) of the composites was affected by the type of ceramics and the crystallinity of polymers. For the composites with same amount of ceramics, the K was decreased and the tan ${\delta}$ was increased with the particle size of ceramics. Also, the dielectric properties of the composites were dependent on the multilayer structures with different arrangements. Several theoretical models have been employed to predict the effective dielectric properties of the composites. The frequency dependence of dielectric properties and the temperature coefficient of resonant frequency (TCF) of the composites were also discussed.

  • PDF

Fabrication of Fine Organic Thin-Film Stripes Using a Hydrophobic Needle (소수성 Needle을 이용한 미세 유기 박막 Stripe 제작)

  • Kim, Jongmyeong;Lee, Jinyoung;Shin, Dongkyun;Park, Jongwoon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.1
    • /
    • pp.73-78
    • /
    • 2020
  • There appears lateral capillary force in a hydrophilic flat needle employed for the fabrication of fine organic thin-film stripes, bringing in an increase of the stripe width. It also causes the stripe thickness to increase with increasing coating speed, which is hardly observed in a normal coating process. Through computational fluid dynamics (CFD) simulations, we demonstrate that the lateral capillary flow can be substantially suppressed by increasing the contact angle of the needle end. Based on the simulation results, we have coated the outer surface of the flat needle with a hydrophobic material (polytetrafluoroethylene (PTFE) with the water contact angle of 104°). Using such a hydrophobic needle, we can suppress the lateral capillary flow of an aqueous poly(3,4-ethylenedioxythiophene): poly(4-styrenesulfonate) (PEDOT:PSS) to a great extent, rendering the stripe narrow (63 ㎛ at 30 mm/s). Consequently, the stripe thickness is decreased as the coating speed increases. To demonstrate its applicability to solution-processable organic light-emitting diodes (OLEDs), we have also fabricated OLED with the fine PEDOT: PSS stripe and observed the strong light-emitting stripe with the width of about 68 ㎛.

Electrical characteristics of insulating materials for HTS bushing immersed in $LN_2$

  • Choi, J.H.;Kim, W.J.;Shin, H.S.;Kim, S.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.4
    • /
    • pp.10-13
    • /
    • 2011
  • For the operation of high temperature superconducting (HTS) power equipments, it is necessary to develop insulating materials and high voltage (HV) insulation technology at cryogenic temperature of bushing. In this paper, the surface flashover characteristics of various insulating materials in $LN_2$ are studied. These results are studied at both AC and impulse voltage under a non-uniform field. The negative impulse breakdown voltage of GFRP is slightly higher than the positive impulse breakdown voltage. The use of glass fiber reinforced plastic (GFRP) and polytetrafluoroethylene (PTFE, Teflon) as insulation body for HTS bushing should be much desirable. Especially, GFRP is excellent material not only surface flashover characteristics but also mechanical characteristics at cryogenic temperature. The surface flashover is most serious problem for the shed design in $LN_2$ and operation of superconducting equipment.

Performances of Plastic Pulley with High Mechanical Properties and Low Friction

  • Kim, Namil;Lee, Jung-Seok;Hwang, Byung-Kook;Bae, Seokhu;Yoon, Jeong-Hwan;Yun, Juho
    • Elastomers and Composites
    • /
    • v.54 no.2
    • /
    • pp.135-141
    • /
    • 2019
  • Polyphenylene sulfide (PPS) was filled with glass fiber (GF), aramid fiber (AF), and solid lubricants to improve the mechanical properties and wear resistance. The addition of GF effectively enhanced the tensile strength, flexural modulus, and impact strength of PPS, while solid lubricants such as polytetrafluoroethylene (PTFE), molybdenum disulfide ($MoS_2$), and tungsten disulfide ($WS_2$) lowered the friction coefficients of the composites to below 0.3. The ball nut and motor pulley of the electric power steering (EPS) were manufactured using the PPS composites, and feasibility was ascertained thereafter by conducting the durability test. The composites filled with GF and AF showed high mechanical strength, but slip occurred at the interface between the pulley and belt while testing above $50^{\circ}C$. When small amounts of lubricants were added, the slip was no longer detected because of the suppression of friction heat. It is realized that the low friction as well as high mechanical properties is important to ensure the reliability of plastic pulleys.

Percutaneous Transhepatic Treatment of Benign Bile Duct Strictures Using Retrievable Covered Stents: Long-Term Outcomes in 148 Patients

  • Byung Soo Im;Dong Il Gwon;Hee Ho Chu;Jin Hyoung Kim;Gi-Young Ko;Hyun-Ki Yoon
    • Korean Journal of Radiology
    • /
    • v.23 no.9
    • /
    • pp.889-900
    • /
    • 2022
  • Objective: To investigate the long-term outcomes of percutaneous treatment of benign biliary strictures using temporary placement of a retrievable expanded polytetrafluoroethylene (PTFE) covered stent. Materials and Methods: We retrospectively analyzed the outcomes of 148 patients (84 male and 64 female; age range, 11-92 years) who underwent percutaneous transhepatic placement and removal of a retrievable PTFE-covered stent for the treatment of benign biliary strictures between March 2007 and August 2019 through long-term follow-up. Ninety-two patients had treatment-naïve strictures and 56 had recurrent/refractory strictures. Results: Stent placement was technically successful in all 148 patients. The mean indwelling period of the stent was 2.4 months (median period, 2.3 months; range, 0.2-7.7 months). Stent migration, either early or late, occurred in 28 (18.9%) patients. Clinical success, defined as resolution of stricture after completing stent placement and removal, was achieved in 94.2% (131 of 139 patients). The overall complication rate was 15.5% (23 of 148 patients). During the mean follow-up of 60.2 months (median period, 52.7 months; range, 1.6-146.1 months), 37 patients had a recurrence of clinically significant strictures at 0.5-124.5 months after removal of biliary stent and catheter (median, 16.1 months). The primary patency rates at 1, 3, 5, 7, and 10 years after removal of biliary stent and catheter were 88.2%, 70.0%, 66.2%, 60.5%, and 54.5%, respectively. In the multivariable Cox proportional hazard regression analysis, sex, age, underlying disease, relation to surgery, stricture type, biliary stones, history of previous treatment, and stricture site were not significantly associated with the primary patency. Conclusion: Long-term outcomes suggest that percutaneous treatment of benign biliary strictures using temporary placement of retrievable PTFE-covered stents may be a clinically effective method.

Simultaneous Determination of Ultra-Trace Pesticides and Synthetic Materials in Surface Water by LC-ESI-MS/MS (하천수에서 LC-ESI-MS/MS에 의한 극미량 농약류 및 합성원료의 동시분석법)

  • Hong, Seon-Haw;Lee, Jun-Bae;Lee, Soo-Hyung;Cho, Young-Hwan;Shin, Ho-Sang
    • Journal of the Korean Chemical Society
    • /
    • v.59 no.3
    • /
    • pp.225-232
    • /
    • 2015
  • A liquid chromatography-electrospray ionization-tandem mass spectrometry method (LC-ESI-MS/MS) was used for determining seven pesticides (2,4-dichlorophenoxyacetic acid, methomyl, aldicarb, 2-methyl- 4-chlorophenoxy- acetic acid, molinate, carbaryl and carbofuran) and two synthetic materials (quinoline and bisphenol-A) in surface water. The analytes were extracted using solid-phase extraction (SPE). The eluate was concentrated by nitrogen gas. 100 microliters of 30% (v/v) methanol aqueous solution were used to dissolve the residue and an aliquot of the reconstituted solution was directly injected into LC-ESI-MS/MS after the filtration using 0.2 μm polytetrafluoroethylene (PTFE) syringe filter. Under the established condition, the calibration curves of the analytes were linear with correlation coefficients of above 0.997. The quantification limit was 0.002~0.011 μg/L and the relative standard deviations were less than 16.4%. In addition, accuracy was in the range of 84~107% and the recoveries were values between 56.2 and 98.6%. In this study, the developed method was applied to the analysis of real surface water samples.

AN EXPERIMENTAL STUDY ON THE EFFECTS OF OXIDIZED CELLULOSE COVERAGE ON THE CORTICAL BONY DEFECTS (피질골 골결손부에서 Oxidized Cellulose 피개의 영향에 관한 실험적 연구)

  • Kim, Hoi-Jong;Rim, Jae-Suk
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.20 no.2
    • /
    • pp.112-126
    • /
    • 1998
  • In dentistry, bony defects can be formed by cyst, tumor, inflammation, trauma and surgery in maxilla and mandible. If the overlying soft tissue invades and preoccupies the jaw bony defects, regenerated bony tissue same as adjacent bone can not replace whole space of the defects, thus preventing osteogenesis from occurring. Guided bone regeneration(GBR) is based on the prevention of overlying soft tissue from entering the bony defect during the initial healing periods. E-polytetrafluoroethylene(e-PTFE) is one of an effective and widely used barrier membrane for GBR, but it has the disadvantages such as surgical removal and high price. To overcome such disadvantages of e-PTFE, many investigators have proposed various absorbable barrier membranes. Inexpensive oxidized cellulose($Surgicel^{(R)}$) membrane was shown to have potential for use as an absorbable barrier membrane for regenerative procedure and it would not require surgical removal. The purpose of this study is to investigate the absorption periods of oxidized cellulose at the implant site and usefulness as a mechanical barrier, preventing the ingrowth of the overlying soft tissue into the bony defects. Two bony defects were made in each tibia of a dog using drill and one defect covered with oxidized cellulose and the other covered with periosteum directly as control. The experimental animals were sacrificed at 1st-7th, 10th, 14th, 21th, 28th day postoperatively, Inspection of the specimens was done to evaluate gross changes. Specimens were examined histopathologically by hematoxylin-eosin and Masson's trichrome staining under light microscope. The results were as follows : 1. There was no significant differences of inflammatory reaction between the experimental and the control group. 2. The resorption of oxidized cellulose was almost completed within 14th day. 3. Histologically, bone formation in the experimental group was somewhat more than that of the control group at 10th, 14th, 21th and 28th day postoperatively. The bone forming pattern of the experimental group was more regular than that of the control group. 4. There was no evidence of soft tissue invasion into the bony defect in the experimental group. In conclusion, oxidized cellulose membrane might be used as an alternative absorbable barrier membrane to prevent overlying soft tissue invasion into the bony defects.

  • PDF

Nitrogen and Phosphorus Removal in Long Term Pilot Plant Operation Using Submerged Hollow Fiber Membrane and Ferric Chloride (침지형 중공사막과 철염을 이용한 Pilot MBR 공정의 장기운전에 따른 질소, 인 제거 특성)

  • Cheong, Jin-Ho;Heo, Yong-Rok;Im, Jeong-Dae;Lee, Eui-Sin;Park, Myung-Gyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.11
    • /
    • pp.1168-1173
    • /
    • 2005
  • Pilot scale vertical-type membrane bioreactor was operated to examine the effect of $FeCl_3$ injection on the removal of organics, nitrogen and phosphorous, and additionally trans-membrane pressure (TMP) was observed. The membrane type was hollow fiber membrane with pore size of $0.25\;{\mu}m$, and the material was polytetrafluoroethylene (PTFE). The membrane permeate was continuously removed by a pump under a constant flux ($25\;L/m^2/h$). Air back-flushing technique were adopted to reduce fouling. As a result, TMP was increased more slowly than that of the operation without air back-flushing, During long-term operation, approximately 310 days, the injection of $FeCl_3$ was effective not only in removing phosphorous chemically but also in reducing TMP increase. Furthermore, while the average COD and T-N concentration of the effluent without $FeCl_3$ injection was 14.3 mg/L and 6.0 mg/L respectively, that of effluent with $FeCl_3$ was 11.3 mg/L and 6.0 mg/L respectively, which confirmed the effects of $FeCl_3$.