Multi-aging Test for Estimating Long Time Performance of Polymer Insulators for Transmission line (송전용 폴리마 런자의 장기성능을 위한 복합열화시험)

  • 조한구;한세원;이운용;윤문수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.640-643
    • /
    • 1999
  • This paper presents the results of multi-stress chamber experiments done to examine the tracking and erosion performance of polymer insulator. Multi-stress testing is able to demonstrate deficiencies of polymer insulator materials and designs, including the nature of interfaces in insulation design. Therefore, multi-stress testing is believed to a suitable test for evaluating the aging performance of polymer insulator designs. We have nvestigated IEC 61109 Annex C for estimating long time performance of polymer insulator.

  • PDF

An Analysis on Characteristics of Surface Discharge on Polymer Insulator Using UV Detected Images (자외선 검출이미지를 이용한 폴리머 애자의 연면방전 특성해석)

  • Shong, Kil-Mok;Kim, Young-Seog;Park, Sang-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.313-314
    • /
    • 2009
  • In this paper, it's described the UV detected images on polymer insulators using UV camera. The patterns of UV detected images are classified into 3 types such as jellyfish(J), amoeba(A), sunflower(S). J type is detected by high electric field in air A type is detected by early surface discharge. And, S type is detected by the serious problem in surface of insulator.

  • PDF

Multi-aging Test Technology for Estimating Long Time Performance of Polymer Insulators (폴리머 절연물 장기성능 평가를 위한 복합열화 시험기술)

  • Cho, H.G.;Han, S.W.;Lee, U.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2332-2334
    • /
    • 1999
  • This paper presents the results of multi-stress chamber experiments done to examine the tracking and erosion performance of polymer insulator. Multi-stress testing is able to demonstrate deficiencies of polymer insulator materials and designs including the nature of interfaces in insulation design. Therefore, multi-stress testing is believed to a suitable test for evaluating the aging performance of polymer insulator designs. We have investigated IEC 61109 Annex C for estimating long time performance of polymer insulator.

  • PDF

Comparison of UV images and Measurement of the Corona Discharge from Insulators using the UV Sensor (UV 센서를 이용한 절연애자의 코로나 방전 측정 및 자외선 이미지의 비교)

  • Kim, Young-Seok;Choi, Myeong-Il;Kim, Chong-Min;Bang, Sun-Bae;Shong, Kil-Mok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.899-904
    • /
    • 2011
  • Inspections and diagnoses of corona discharge are important in order to prevent electrical faults of external insulation in power systems. This paper studies a measurement of ultra-violet rays(UV) strength of corona discharges on insulators using a UV sensor with an optic lens. The data has been compared with the images of a UV camera. The UV sensor estimated that DC voltage needed to be set at 700V for accurate data analysis of the properties of UV detected during corona discharge. UV was generated at 60kV when the corona discharge occurred. UV strength and images of UV increased at a high voltage. The image area of the UV using a UV camera and the detection of UV using a UV sensor have shown, that the polymer insulator mounted on a live part must be checked when the applied voltage on the good polymer insulator is greater than 37.5% of its breakdown voltage.

Reliability Evaluation Criteria and Multi-Stress Aging Test for Polymer Insulator (폴리머 현수애자의 신뢰성 평가 및 복합가속열화 방법)

  • Park, Hoy-Yul;Kang, Dong-Pil;Ahn, Myeong-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.469-472
    • /
    • 2004
  • There have been numerous accelerated aging laboratory tests for evaluating suitability of polymeric materials and devices. Aging test for materials and its full scale device has been conducted, but poor correlation of aging test such as service experience were observed. Service experience plays a key role in the utility section of composite insulators. A meaningful and reliable accelerated aging test is needed for evaluating composite insulator. During the service these insulators are subjected to aging stress such as humidity, pollution, and electrical field, and erosion and tracking of the weathershed occurs. This paper presents the criteria of reliability evaluation and evaluation facilities for 22.9 kV suspension composite insulator. We adopt the criteria of reliability evaluation consist of two test methods. One is CEA tracking wheel test for examining the tracking and erosion performance of composite insulator. The other is multi-stress aging test for examining effects of environmental factors such as UV, temperature, humidity, etc on composite insulator.

  • PDF

A Case Study of Degradation Characteristics for Rod-Insulator on Catenary System in Electric Railway (전기철도 전차선로 지지애자의 염해지역 열화특성 사례 연구)

  • Jung, Hosung;Park, Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.4
    • /
    • pp.263-266
    • /
    • 2019
  • In the Airport Railroad, the Yeongjong Bridge has a length of 4,420 m and connects Yeongjong Island with the mainland of Incheon City. The bridge is a two-level structure, consisting of a six-lane road at the upper level and a combination of a road and railroad at the lower level. The environmental conditions for the electric railway come mainly from the salt injury area and a heavy industry zone, and the maintenance cycles are determined differently depending on these conditions. This study analyzed the deterioration characteristics of long rod insulators produced with a movable ceramic bracket and polymer materials in the Yeongjong Bridge section of the Airport Railway operating in the salt injury area according to the material characteristics. Comparison of the corona measurements when the insulators were cleaned at the same time showed that the polymer insulator had a higher insulation performance than the ceramic insulator.

A Study on Synthetic Failure-finding Method for Electrical and Thermal Degradation of Polymer Insulator by Surface Discharge

  • Lee, Kang-Won;Jang, Dong-Uk;Park, Cheol-Hyun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.3
    • /
    • pp.143-146
    • /
    • 2007
  • Polymer insulators are used widely in variable fields for high voltage insulation and separating people from high voltage charging parts for safety and also supporting overhead power line in electric railway. But it may be broken down by tracking path resulting from continuous surface discharge. This paper has investigated synthetically both the characteristics of electrical aging using precision CT(current transformer) and the thermal aging using thermography method. Electrical aging was analyzed for time-frequency region and thermal aging was illustrated by image processing method. This synthetic method may be an appropriate one to evaluate the surface degradation of polymer insulator.

Study on the Effects of Space Charge on Conduction Current (공간전하에 따른 전도전류의 변화에 대한 연구)

  • Choe, Su-Il;Lee, June-Ho;Kim, Gyu-Eon;Kim, Jong-Min;HwangBo, Seung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.12
    • /
    • pp.2225-2229
    • /
    • 2010
  • In this study, we have investigated the effects of space charge on the conduction current with the variation of applied time of electric field in polymer insulators. We had also improved the PEA method, and then we could measure a simultaneously the space charge and the conduction current in insulators under the DC electric field. From this experiment, we have known the variation of conduction current due to the existence of space charge in XLPE1 and XLPE2.

Characteristices for the Electric Field of Composite Insulator Silicone Shed (Composite Insulator silicone shed 전계특성)

  • Jang, Yoon-Ki;Choi, Sung-Man;Chung, Young-Soo;Lee, Dong-Woen;Kim, Jung-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.99-100
    • /
    • 2008
  • Composite insulators are rapidly replacing their porcelain counterparts in electrical substation applications. The composite insulator provide technical and safety ad vantages over other types of insulator. These insulators consist of a FRP(Fiber-reinforced polymer), with two metal flanges and silicone rubber. In this paper, we have investigated the influence of electric field different shaped silicone shed under $SF_6$ gas. As a result, shape of silicone rubber does not effected a electric field. However, the shape of shed can be decided the creepage distance.