• Title/Summary/Keyword: Polyethylene pipe

Search Result 90, Processing Time 0.028 seconds

Durability of Various Anti-Corrosive Organic Coatings in Marine Environment for Twelve Years

  • Yamamoto, Mashiro;Kajiki, Toshitaka;Kamon, Toshikuni;Yoshida, Kotaro
    • Corrosion Science and Technology
    • /
    • v.3 no.1
    • /
    • pp.20-25
    • /
    • 2004
  • In order to clarify the durability of protective coatings for maritime steel structures, various anti-corrosive organic coated steel samples were exposed for twelve years in semitropical marine environment at Miyakojima Island, Okinawa, JAPAN. Samples were various organic coated steel pipes, 4.0 m in length and 150 mm in diameter. While the bare steel pipe entirely corroded in 4.5 mm thickness in four and half years, these organic coated steel pipes exhibited protective appearances after twelve-year-exposure except for the defect in the coatings. Polyethylene (PE) lining pipe exhibited a good protective performance. Urethane painted pipe was also good but some barnacles stuck to its surface. A combination of petrolatum tape and FRP cover showed sufficient corrosion resistance for steel surface. The correlation in results between exposure and laboratory acceleration test was examined. It was found that salt spray test (SST) results corresponded to rusted area of scratched portion and that adhesion change of coating layer corresponded to the rotating immersion test result. Among the on-site measured data, volume resistivity is utilized for the index of corrosion protection performance of organic coating.

Evaluation of the Reaction-to-fire Performance of Pipe Insulation Material using Small Room Test (룸코너 시험을 이용한 배관용 보온재의 난연성능 분석)

  • Lim, Ohk Kun;Nam, Dong-gun;Jang, Hyo-Yeon
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.1-8
    • /
    • 2019
  • Reaction-to-fire performance of pipe insulation materials should be approved in accordance with KS standards prior to installing water-based suppression systems because several fire accidents are initiated from insulation materials around ceilings or concealed space. A small room test to evaluate the reaction-to-fire performance of the polyethylene foam and elastomeric pipe insulation materials was conducted according to ISO 20632. Different fire growth rate and heat release rate are observed depending on the materials and construction methods. In order to improve a fire safety, the reaction-to-fire performance of pipe insulation material needs to be subdivided with regard to the heat release rate and smoke generation. Furthermore, the characteristics of the applying space are also required to be considered. Subsidiary materials for installation process such as tape and adhesive are found to provide an adverse effect to maintain a fire safety.

Study on the Chlorine-Resistant Bacteria Isolated from Water Pipe Network (상수도관망에서 분리한 잔류염소 내성균에 관한 연구)

  • Hyun, Jae-Yeoul;Yoon, Jong-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.3
    • /
    • pp.334-341
    • /
    • 2011
  • The free residual chlorine of tap water samples, collected from 266 faucets on the water pipe network in Daegu City, was between 0.1 and 0.79 mg/L. On microorganic tests, general bacteria and the coliform goup were not detected and thus the tap water was turned out to be fit to drink. In particular, samples of which free residual chlorine was 0.1 mg/L and over were cultured in R2A agar media at $25^{\circ}C$ for 7 days, and as a result heterotrophic bacteria were detected in 65.9% of samples; (1). The closer tap water got to the faucet from the stilling basin, the lower residual chlorine concentration became but the more the bacterial count became. And, more bacteria were detected in the R2A agar medium than in the PCA medium. (2). In the case of separated strains, most colonies were reddish or yellowish. 16S rRNA sequence was identified as Methylobacterium sp. and Williamsia sp., and yellow strain was identified as Sphingomonas sp., Sphingobium sp., Novosphingobium sp., Blastomonas sp., Rhodococcus sp. and Microbacterium sp. White strain was identified as Staphylococcus sp. (3). Sterilized tap water in polyethylene bottles was inoculated with separated strain and was left as it was for 2 months. As a result, bio-film was observed in tap water inoculated with Methylobacterium sp. and Sphingomonas sp. It was found that heterotrophic bacteria increased when free residual chlorine was removed from tap water in the water pipe network. Thus, there is a need to determine a base value for heterotrophic bacteria in order to check the cleanliness of tap water in the water pipe network.

A Study on the Comparison of the Backfill Loads Obtained by the Marston-Spangler에s Theory and by the Finite Element Analysis for the Metal-Polyethylene Composite Pipes (금속-폴리에틸렌 복합관에 대해서 Marston-Spagler이론과 유한요소해석에 의해 구해진 뒤채움하중의 비교에 관한 연구)

  • 정진호
    • Geotechnical Engineering
    • /
    • v.14 no.5
    • /
    • pp.89-110
    • /
    • 1998
  • Variations of backfill load on the metal-polyethylene composite( MPC ) pipes buried in various trenches backfill afterward were investigated in this paper. The backfill loads obtained by the finite element method( FBM ) were compared with those calculated by the well-known MarstonBpangler(M-5) theory. The reliability of the finite element analysis used in this study was examined by an inaitu best for the buried pipe. The backfill lords and deflections on the real-size pipe buried on-site were measured while increasing the backfill height. In addition, further investigations were made for the variations of the backfill loads as a function of several important parameters such as the backfill soil type, bach. height$(\leq4.0m)$, diameter of the pipe$(B.$1.0m)$, and trench width($\leq 3.0 B_c$). It is confirmed that the M-S theory predicts reasonably well the backfill loafs of the MPC of the M-S backfill coils be 0.13 and 0.15 for the SC and SM coils in the D unman soil model, respectively. The load ratio, Wu-s/WwgM for a narrow trench varies negligibly with the back(111 height but fiends to increase for a wide trench. The ratio increases with increasing diameter of the pipe for a narrow trench while decreasing for a wide trench. It is also found that the ratio generally decreases as the degree of compaction increases and BM soil exhibits larger load ratio than that of SC soil.

  • PDF

Construction Method of Seohae Grand Bridge (서해대교 시공 공법 소개)

  • Yoon Tae Seob
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.255-266
    • /
    • 2000
  • Since 1993, Seohae grand bridge has been continued construction for 7 years and will be completed late this year. The bridge is a part of west sea castal highway and consists of 3 types of bridge including precast segmental method, free cantilever method and cable stayed bridge. A cable stayed bridge is the core of this bridge and it consists of 5 span, symetrical cable-stayed bridge with a total length of 990 m. The main span between two H-shaped pylons extending approximately 180 M above massive foundation of a cable stayed bridge is 470 m long and an approach span of that is 260 m long respectively. The circular cofferdam with 16 ea of 25 m diameter flat type sheet pile had been applied to construct foundation. The slipform method had been applied for forming of con'c of two H-shaped pylons with 3 cross beams respectively which is varied horizontally and vertically. The deck has been erected with balanced cantilever method using movable derrick crane. The stay cables is a bundle of parallel individually protected, 7 wire high tensile strands. The strands is hot deep galvanized and sheathed with a tight high density polyethylene coating. A petroleum wax fills all the inter-wire voids. The bundle of strands to prevent from deterioration due to the ambient problem covered with high density polyethylene pipe. The Isotension method has been applied for the stressing of cable strands to ensure uniformity of force in all the strands of a syay and such works has been performed on the stay specially provided in the pylon.

  • PDF

Study of Thrust Control Performance Improvement for Hybrid Rocket Applications (하이브리드 로켓의 추력제어 성능 향상에 관한 연구)

  • Choi, Jae-Sung;Kang, Wan-Kyu;Huh, Hwan-Il
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.1
    • /
    • pp.55-62
    • /
    • 2011
  • In this study, we tried to improve the thrust control performance through the thrust control combustion experiment of the hybrid rocket. We constructed the system which controls the oxidizer flow by combining a needle valve with a stepping motor and controlling the stepping motor drive according to the thrust control command order. Gas oxygen was used as the oxidizer for two different propellants, PE(Polyethylene), PC(Polycarbonate), respectively. To improve the slow response time and the oscillation phenomenon in the beginning stage of the thrust control combustion experiment, we measured and analyzed the change of the flow speed of the propellant pipe. The revised thrust control combustion experiment showed that the thrust was stably controlled with the margin or error from the thrust command within ${\pm}1$ N.

The Fusion Characteristic Varying with Butt Fusion Times for Polyethylene Pipe (PE배관 버트 융착 시간에 따른 융착 특성 변화)

  • 이영순;장영오
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.199-205
    • /
    • 1998
  • Butt fusions were practiced with butt fusion in the various conditions of fusion temperatures, pressure and time, and the tests of tesile strength, breaking water pressure and fusion features were also practiced so that the reliability of the butt fusion and the fittets fusion condition may be closely examined. And the width, height and thickness of the beads were also closely measured. The fittest fusion result was achieved in the condition of the temperature of $210^{\circ}C$, heating time hight pressure of 14 seconds on the pressure of $1.5kg/cm^2$, heating time hight pressure of 100 seconds and pressure buid-up time of 11 seconds. And in case of the temperature of $250^{\circ}C$, the fittest fusion result was showed in the condition of the heating time hight pressure of 3 seconds on the pressure of 1.0$kg/cm^2$, the heating time low pressure variable of 100 seconds. heating time hight pressure of 14 seconds and the heating maintenance of around 60 seconds. The result of breaking water pressure test of a test piece fusion in the fittest fusion condition was that the fusion condition of the PE pipe showed a good stability and hight reliance. Through this test, it is proved that the temperature of fusion PE pipes can be increased to $250^{\circ}C$ from $210^{\circ}C$. And it can be expected that the above fusion method greatly helps to reduce the fusion time.

  • PDF

Cover Requirements for Corrugated HDPE and PVC Pipes Used for Cross-drains in Highway Construction (고속도로 하부 횡단 배수시설로 사용되는 파형 플래스틱 관의 덮개 요건)

  • Kang, Junsuk;Davidson, James S.;Lim, Jeong-Hyeon;Kang, Young Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.4 no.1
    • /
    • pp.15-24
    • /
    • 2013
  • This project investigated the use of two types of thermoplastic pipes, High-Density Polyethylene (HDPE) and Poly-vinyl Chloride (PVC), as cross-drains under highways. Pipes ranging from 0.3 m (12 in.) to 1.5 m (60 in.) in diameter were evaluated under deep fills, minimum cover, and construction loads. In addition to a comprehensive literature review, an analytical study into the allowable fill heights for thermoplastic pipes and a field study to observe the installation and performance of the pipe in service conditions were conducted. Based on the study findings, recommendations regarding how and when thermoplastic pipe should be installed are provided.

Development of Nutrient Solution Cooling System in Hydroponic Greenhouse (수경재배 온실의 양액냉각시스템 개발)

  • 남상운;김문기
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.36 no.3
    • /
    • pp.113-121
    • /
    • 1994
  • Since it is difficult to expect the normal production of plants in greenhouses during hot summer season in Korea, certain provisions on the control of extreme environmental factors in summer should be considered for the year-round cultivation in greenhouses. This study was carried out to find a method to suppress the temperature rising of nutrient solution by cooling, which is able to contribute to the improvement of the plant growth environment in hydroponic greenhouse during hot summer season. A mechanical cooling system using the counter flow type with double pipe was developed for cooling the nutrient solution efficiently. Also the heat transfer characteristics of the system was analysed experimentally and theoretically, and compared with the existing cooling systems of nutrient solution. The cooling capacities of three different Systems, which used polyethylene tube in solution tank, stainless tube in solution tank, and the counter flow type with double pipe, were evaluated. The performance of each cooling system was about 41 %, 70% and 81 % of design cooling load in hydroponic greenhouse of 1 ,000m$^2$ on the conditions that the flow rate of ground water was 2m$^3$/hr and the temperature difference between two liquids was 10 ˚C According to the results analysed as above, the cooling system was found to have a satisfactory cooling capability for regions where ground water supply is available. Fer the other regions where ground water supply is restricted, more efficient cooling System should be developed.

  • PDF

A Study on the Manufacturing, Mechanical Properties,Abrasion Resistance, and Slow Crack Growth Resistance of the Recycled Polyethylene/Fly Ash Composites (재생 폴리에틸렌/비산회 분말 충전 복합체 제조와 기계적 물성, 내마모성 및 저속균열성장 저항성에 관한 연구)

  • Kye, Hyoung-San;Shin, Kyung-Chul
    • Elastomers and Composites
    • /
    • v.46 no.4
    • /
    • pp.335-342
    • /
    • 2011
  • The virgin and recycled polyethylene composites with various ratio of fly ash were manufactured by using a fully intermeshing co-rotating twin screw extruder for the reuse of fly ash from power plant and post-consumed polyethylene. Fly ash were blended with virgin HDPE and recycled polyethylene at the weight fraction of 0 to 40 wt.%. Mechanical properties such as yield strength, abrasion resistance, and slow crack resistance were measured with ISO and ASTM standards. The experimental results for the various composites showed that the elongation at break and the yield stress of the composites decreased with increasing fly ash contents. Generally, the abrasion resistance of PEs decreased with increasing sandpaper grits but the abrasion resistance of the composites increased with fly ash content at finer abrasive surface. The slow crack growth resistance of virgin HDPE, recycled JRPE and the JRPE composite showed higher slow crack growth resistance up to 50% of load at notch depth of 20% and 30%, but KRPE and the KRPE composite showed much lower resistance than virgin HDPE, JRPE and the JRPE composite. Time to break, measured with NCLS test method, of all PEs and the composites satisfies the regulation of Korean Industrial Specification for sewer pipe and support application.