• Title/Summary/Keyword: Polydadmac

Search Result 1, Processing Time 0.018 seconds

Evaluation of Streaming Current Detector (SCD) and Charge Analyzing System (CAS) for automation of coagulant dosage determination (낙동강 하류 원수의 응집제 주입 자동화를 위한 Streaming Current Detector (SCD)와 Charge Analyzing System (CAS)의 평가)

  • Kim, Sang-Goo;Son, Hee-Jong;Lee, Jeong-Kyu;Yeom, Hoon-Sik;Yoo, Pyung-Jong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.4
    • /
    • pp.201-207
    • /
    • 2017
  • This study was conducted to investigate the characteristics of the stream current detector (SCD) and charge analyzing system (CAS), which are well known as the automatic coagulant dosage determination instruments. When the SCD system was used, the current charge value set at pH 9.3 could not be used as the coagulant dosage when the pH of the raw water decreased to 5.7, and the current charge value corresponding to pH 5.7 was required to be reset. In case of CAS system, polydadmac is stable as a cationic titrant when the pH of the raw water ranged 9.3 to 6.0. And it was effective to use polydadmac as a cationic titrant for high turbidity water. The current charge of polydadmac was almost constant between pH 5 and 11, however, the difference in charge of alum is six times in this pH range. Therefore, when the pH of the raw water was changed, it seems that the coagulant used in the actual water treatment plant was as a good cationic titrant.