• Title/Summary/Keyword: Polyamide-12

Search Result 71, Processing Time 0.023 seconds

COMPARATIVE HISTOPATHOLOGIC STUDY ON RAT VESSELS ANASTOMOSIS WITH 3 DIFFERENT SUTURE MATERIALS (봉합재료에 따른 백서 미세혈관문합의 조직병리학적 연구)

  • Sung, Iel-Yong;Kim, Jong-Ryoul
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.22 no.1
    • /
    • pp.22-32
    • /
    • 2000
  • Purpose : Histopathologic observation was performed in order to determine which type of suture material is superior in microvascular anastomoses. Materials & Methods : The interrupted end to end anastomosis of the transected carotid arteries of 105 Sprague-Dawley rats, weighing 180 to 200g, were performed using 9-0 polypropylene ($Prolene^{TM}$, Ethicon, U.K.), 9-0 polyglactin 910 monofilament($Vicryl^{TM}$, Ethicon, U.K.), and 9-0 polyamide($Ethilon^{TM}$, Ethicon, U.K.) under intramuscular Ketamine and Xylazine anesthesia(5mg/100g). In all cases, 10 to 12 sutures were placed to complete the anastomoses. The specimens were obtained at 1, 2, 3 days, and 1, 2, 4 and 6 weeks after the surgery and prepared with H&E and Van-Gieson stains and investigated the histologic changes in anastomotic sites under light microscope. The histologic changes we were concerned about were followings- thrombus formation, intimal edema, infiltration of inflammatory cells in media and adventitia, proliferation of endothelial cells and subintimal hyperplasia. Results : 1. All of the anastomosed arteries were patent when they were exposed for examination. 2. Thrombus formation and intimal edema were most severe in Vicryl group, followed by Ethilon, Prolene group in order. 3. The inflammatory cells infiltrated to the media and the adventitia most severely in Ethilon group, followed by Vicryl, Prolene group in order. 4. There was little difference in proliferation of endothelial cells in each group. 5. Subintimal hyperplasia was greater in Vicryl group than the others, but there was no significant difference between the Prolene and Ethilon groups. Conclusions : On the basis of these observations, we could conclude that Prolene may be the better suture material for microvascular anastomoses regarding the tissue responses than Ethilon and Vicryl.

  • PDF

Surface properties and interception behaviors of GO-TiO2 modified PVDF hollow fiber membrane

  • Li, Dongmei;Liang, Jinling;Huang, Mingzhu;Huang, Jun;Feng, Li;Li, Shaoxiu;Zhan, Yongshi
    • Membrane and Water Treatment
    • /
    • v.10 no.2
    • /
    • pp.113-120
    • /
    • 2019
  • To investigate surface properties and interception performances of the new modified PVDF membrane coated with Graphene Oxide (GO) and nano-$TiO_2$ (for short the modified membrane) via the interface polymerization method combined with the pumping suction filtration way, filtration experiments of the modified membrane on Humic Acid (HA) were conducted. Results showed that the contact angle (characterizing the hydrophilicity) of the modified membrane decreased from $80.6{\pm}1.8^{\circ}$ to $38.6{\pm}1.2^{\circ}$. The F element of PVDF membrane surface decreased from 60.91% to 17.79% after covered with GO and $TiO_2$. O/C element mass ratio has a fivefold increase, the percentage of O element on the modified membrane surface increased from 3.83 wt% to 20.87%. The modified membrane surface was packed with hydrophilic polar groups (like -COOH, -OH, C-O, C=O, N-H) and a functional hydrophilic GO-polyamide-$TiO_2$ composite configuration. This configuration provided a rigid network structure for the firm attachment of GO and $TiO_2$ on the surface of the membrane and for a higher flux as well. The total flux attenuation rate of the modified membrane decreased to 35.6% while 51.2% for the original one. The irreversible attenuation rate has dropped 71%. The static interception amount of HA on the modified membrane was $158.6mg/m^2$, a half of that of the original one ($295.0mg/m^2$). The flux recovery rate was increased by 50%. The interception rate of the modified membrane on HA increased by 12% approximately and its filtration cycle was 2-3 times of that of the original membrane.

Evaluation of trueness and precision of removable partial denture metal frameworks manufactured with digital technology and different materials

  • Leonardo Ciocca;Mattia Maltauro;Elena Pierantozzi;Lorenzo Breschi;Angela Montanari;Laura Anderlucci;Roberto Meneghello
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.2
    • /
    • pp.55-62
    • /
    • 2023
  • PURPOSE. The aim of this study is to evaluate the accuracy of removable partial denture (RPD) frameworks produced using different digital protocols. MATERIALS AND METHODS. 80 frameworks for RPDs were produced using CAD-CAM technology and divided into four groups of twenty (n = 20): Group 1, Titanium frameworks manufactured by digital metal laser sintering (DMLS); Group 2, Co-Cr frameworks manufactured by DMLS; Group 3, Polyamide PA12 castable resin manufactured by multi-jet fusion (MJF); and Group 4, Metal (Co-Cr) casting by using lost-wax technique. After the digital acquisition, eight specific areas were selected in order to measure the Δ-error value at the intaglio surface of RPD. The minimum value required for point sampling density (0.4 mm) was derived from the sensitivity analysis. The obtained Δ-error mean value was used for comparisons: 1. between different manufacturing processes; 2. between different manufacturing techniques in the same area of interest (AOI); and 3. between different AOI of the same group. RESULTS. The Δ-error mean value of each group ranged between -0.002 (Ti) and 0.041 (Co-Cr) mm. The Pearson's Chi-squared test revealed significant differences considering all groups paired two by two, except for group 3 and 4. The multiple comparison test documented a significant difference for each AOI among group 1, 3, and 4. The multiple comparison test showed significant differences among almost all different AOIs of each group. CONCLUSION. All Δ-mean error values of all digital protocols for manufacturing RPD frameworks optimally fit within the clinical tolerance limit of trueness and precision.

Bio-Conjugated Polycaprolactone Membranes: A Novel Wound Dressing

  • Cai, Elijah Zhengyang;Teo, Erin Yiling;Jing, Lim;Koh, Yun Pei;Qian, Tan Si;Wen, Feng;Lee, James Wai Kit;Hing, Eileen Chor Hoong;Yap, Yan Lin;Lee, Hanjing;Lee, Chuen Neng;Teoh, Swee-Hin;Lim, Jane;Lim, Thiam Chye
    • Archives of Plastic Surgery
    • /
    • v.41 no.6
    • /
    • pp.638-646
    • /
    • 2014
  • Background The combination of polycaprolactone and hyaluronic acid creates an ideal environment for wound healing. Hyaluronic acid maintains a moist wound environment and accelerates the in-growth of granulation tissue. Polycaprolactone has excellent mechanical strength, limits inflammation and is biocompatible. This study evaluates the safety and efficacy of bio-conjugated polycaprolactone membranes (BPM) as a wound dressing. Methods 16 New Zealand white rabbits were sedated and local anaesthesia was administered. Two $3.0{\times}3.0cm$ full-thickness wounds were created on the dorsum of each rabbit, between the lowest rib and the pelvic bone. The wounds were dressed with either BPM (n=12) or Mepitel (n=12) (control), a polyamide-silicon wound dressing. These were evaluated macroscopically on the 7th, 14th, 21st, and 28th postoperative days for granulation, re-epithelialization, infection, and wound size, and histologically for epidermal and dermal regeneration. Results Both groups showed a comparable extent of granulation and re-epithelialization. No signs of infection were observed. There was no significant difference (P>0.05) in wound size between the two groups. BPM (n=6): $8.33cm^2$, $4.90cm^2$, $3.12cm^2$, $1.84cm^2$; Mepitel (n=6): $10.29cm^2$, $5.53cm^2$, $3.63cm^2$, $2.02cm^2$; at the 7th, 14th, 21st, and 28th postoperative days. The extents of epidermal and dermal regeneration were comparable between the two groups. Conclusions BPM is comparable to Mepitel as a safe and efficacious wound dressing.

CLINICAL STUDY OF AUGMENTATION MALARPLASTY WITH POROUS POLYETHYLENE (Porous polyethylene을 이용한 관골증대술의 임상연구)

  • Kook, Min-Suk;An, Jin-Suk;Kim, Young-Joon;Park, Hong-Ju;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.3
    • /
    • pp.283-291
    • /
    • 2008
  • The malar mound defines the contour of the lateral face between the inferior orbital rim and the mandible, and hypoplasia or asymmetry of this region is readily noticeable. A flat, hypoplastic malar eminence can make the face blunt and wearisome, which contributes to a premature aged appearance. Patients with congenital or traumatic flattening of the malar eminence can obtain esthetic improvement with implants. Indications for placement of malar implants to improve the appearance of subtle flattening or to enhance the esthetic harmony of a patient's face have been suggested in several studies. Many augmentation materials, such as silicone, proplast, polyamide, and porous polyethylene implants have been used. Many methods of localization have been described, the key to proper placement of the implants lies in a through understanding of the esthetics of the malar mound. From August 2001 to June 2007, 12 patients with malar depression who visited the Department of Oral and Maxillofacial Surgery, Chonnam National University Hospital were treated by augmentation malarplasty with Porous polyethylene. The location and amount of augmentation are determined by preoperative interview, physical examinations, facial models and radiographic findings. 12 patients were satisfied with the results of augmentation malarplasty and severe complications were not occurred.

Fabrication of a Patient-Customized Helmet with a Three-Dimensional Printer for Radiation Therapy of Scalp

  • Oh, Se An;Lee, Chang Min;Lee, Min Woo;Lee, Yeong Seok;Lee, Gyu Hwan;Kim, Seong Hoon;Kim, Sung Kyu;Park, Jae Won;Yea, Ji Woon
    • Progress in Medical Physics
    • /
    • v.28 no.3
    • /
    • pp.100-105
    • /
    • 2017
  • The purpose of the present study was to develop and evaluate patient-customized helmets with a three-dimensional (3D) printer for radiation therapy of malignant scalp tumors. Computed tomography was performed in a case an Alderson RANDO phantom without bolus (Non_Bolus), in a case with a dental wax bolus on the scalp (Wax_Bolus), and in a case with a patient-customized helmet fabricated using a 3D printer (3D Printing_Bolus); treatment plans for each of the 3 cases were compared. When wax bolus was used to fabricate a bolus, a drier was used to apply heat to the bolus to make the helmet. $3-matic^{(R)}$ (Materialise) was used for modeling and polyamide 12 (PA-12) was used as a material, 3D Printing bolus was fabricated using a HP JET Fusion 3D 4200. The average Hounsfield Unit (HU) for the Wax_Bolus was -100, and that of the 3D Printing_Bolus was -10. The average radiation doses to the normal brain with the Non_Bolus, Wax_Bolus, and 3D Printing_Bolus methods were 36.3%, 40.2%, and 36.9%, and the minimum radiation dose were 0.9%, 1.6%, 1.4%, respectively. The organs at risk dose were not significantly difference. However, the 95% radiation doses into the planning target volume (PTV) were 61.85%, 94.53%, and 97.82%, and the minimum doses were 0%, 77.1%, and 82.8%, respectively. The technique used to fabricate patient-customized helmets with a 3D printer for radiation therapy of malignant scalp tumors is highly useful, and is expected to accurately deliver doses by reducing the air gap between the patient and bolus.

Effect of Permeability-Controlled Polyethylene Film on Extension of Shelf-life of Brined Baechu Cabbage (투과도 조절 폴리에틸렌 필름의 절임배추 보존기간 연장효과)

  • Kim, Young-Wook;Jeong, Ji-Kang;Lee, Sun-Mi;Kang, Soon-Ah;Lee, Dong-Sun;Kim, So-Hee;Park, Kun-Young
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.12
    • /
    • pp.1767-1772
    • /
    • 2009
  • Brined Baechu cabbages were packed with different films of high density polyethylene (HDPE), aluminium polyethylene (Al/PE), nylon polyamide (Ny/PE), low density polyethylene (LDPE) and permeability-controlled polyethylene (Mirafresh (MF), US patent No. 5972815), and then stored at 4${^{\circ}C}$ for 4 weeks. Changes in quality characteristics of pH, acidity, total bacteria counts, lactic acid bacteria counts, E. coli counts, texture and $O_2$ concentration were determined during the storage. The pH of brined Baechu cabbage packed with Mirafresh (MF) film was 6.25 after 4 weeks from initial pH of 6.80. The acidity of all brined Baechu cabbages increased, however, the increase of the cabbage in MF was the lowest. The levels of total bacteria, lactic acid bacteria and E. coli in the cabbages packed with MF were also lower than the other films. After 4 weeks, of all brined springiness Baechu cabbages decreased, but MF showed relatively high springiness. The $O_2$ concentrations by its permeation through MF were 0.35%-1.00% at 4-25${^{\circ}C}$ after 1 week. In conclusion, MF was found to be the most effective packaging film for brined Baechu cabbage to extend shelf-life.

Preparation and Adsorption Properties of PA6/PSMA-OA Molecularly Imprinted Composite Membranes in Supercritical CO2

  • Zhang, Qing;Zhang, Xingyuan;Zhang, Wencheng;Pan, Jian;Liu, Ling;Zhang, Haitao;Zhao, Dong;Li, Zhi
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.9
    • /
    • pp.3348-3354
    • /
    • 2011
  • Oleanolic acid (OA) as template molecule, polyamide-6 (PA6) as basement membrane and poly(styrene-comaleic acid) (PSMA) were used to prepare PA6/PSMA-OA molecularly imprinted composite membranes by phase inversion method in supercritical $CO_2$ ($ScCO_2$). The template molecule (OA), [poly(styrene-co-maleic anhydride) (PSMAH), PSMA, molecularly imprinted membranes (MIMs) imprinting OA and MIMs after elution were all characterized by Fourier transform infrared spectroscopy (FTIR). The conditions that were the mass ratio between PSMA and OA from 3:1 to 8:1, temperature of $ScCO_2$ from $35^{\circ}C$ to $50^{\circ}C$ and pressure of $ScCO_2$ 12 MPa to 17 MPa were studied. It was obtained the largest adsorption rate and purity of OA after adsorption of the resultant MIMs, 50.41% and 96.15% respectively. After using PA6 film and non-woven fabrics as basement membrane respectively, it was found that smaller aperture of PA6 was used as basement membrane, a higher adsorption rate and a higher purity of OA after adsorption of the MIMs were obtained, and so were the stability and reproducibility of the resultant MIMs. After template molecules being removed, the MIMs had effective selectivity hydrogen bonding to separately bind in the binary components to the template molecules-oleanolic acid.

RUNX1-Survivin Axis Is a Novel Therapeutic Target for Malignant Rhabdoid Tumors

  • Masamitsu, Mikami;Tatsuya, Masuda;Takuya, Kanatani;Mina, Noura;Katsutsugu, Umeda;Hidefumi, Hiramatsu;Hirohito, Kubota;Tomoo, Daifu;Atsushi, Iwai;Etsuko Yamamoto, Hattori;Kana, Furuichi;Saho, Takasaki;Sunao, Tanaka;Yasuzumi, Matsui;Hidemasa, Matsuo;Masahiro, Hirata;Tatsuki R., Kataoka;Tatsutoshi, Nakahata;Yasumichi, Kuwahara;Tomoko, Iehara;Hajime, Hosoi;Yoichi, Imai;Junko, Takita;Hiroshi, Sugiyama;Souichi, Adachi;Yasuhiko, Kamikubo
    • Molecules and Cells
    • /
    • v.45 no.12
    • /
    • pp.886-895
    • /
    • 2022
  • Malignant rhabdoid tumor (MRT) is a highly aggressive pediatric malignancy with no effective therapy. Therefore, it is necessary to identify a target for the development of novel molecule-targeting therapeutic agents. In this study, we report the importance of the runt-related transcription factor 1 (RUNX1) and RUNX1-Baculoviral IAP (inhibitor of apoptosis) Repeat-Containing 5 (BIRC5/survivin) axis in the proliferation of MRT cells, as it can be used as an ideal target for anti-tumor strategies. The mechanism of this reaction can be explained by the interaction of RUNX1 with the RUNX1-binding DNA sequence located in the survivin promoter and its positive regulation. Specific knockdown of RUNX1 led to decreased expression of survivin, which subsequently suppressed the proliferation of MRT cells in vitro and in vivo. We also found that our novel RUNX inhibitor, Chb-M, which switches off RUNX1 using alkylating agent-conjugated pyrrole-imidazole polyamides designed to specifically bind to consensus RUNX-binding sequences (5'-TGTGGT-3'), inhibited survivin expression in vivo. Taken together, we identified a novel interaction between RUNX1 and survivin in MRT. Therefore the negative regulation of RUNX1 activity may be a novel strategy for MRT treatment.

Quality and Shelf-Life of Vacuum Packed RTE (Ready-To-Eat) Hamburg Steak Depending on the Oxygen Permeability of Packaging Material and the Storage Temperature (포장재의 산소투과도와 저장온도에 따른 즉석섭취형 햄버그스테이크의 품질 및 저장성)

  • Lim, Ji Hoon;Lee, Sung Ki;Chung, Seung Hee;Lee, Keun Taik
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.22 no.3
    • /
    • pp.95-102
    • /
    • 2016
  • This study investigated the effects of the oxygen permeability of vacuum packaging film and the storage temperature on the quality and shelf life of Hamburg steaks during storage for 14 days. Control samples (C) were packaged in a polyamide/polyethylene (PA/PE) film and stored at $5^{\circ}C$. Treatment samples were either packaged in an ethylene vinyl alcohol/polyethylene (EVOH/PE) copolymer film and stored at $5^{\circ}C$ (T1), and in a PA/PE film and stored at $-18^{\circ}C$ (T2). The initial total plate count (TPC) was 3.6 log cfu/g. In T1 samples, TPC and Brochothrix thermosphacta counts were increased, similar to those in C samples, whereas Pseudomonas spp. counts were significantly lower than those in C samples during storage. Over the storage period, the volatile basic nitrogen values increased most rapidly in C samples, followed by T1 and then T2 samples. The values of thiobarbituric acid reactive substances steadily increased in all samples during storage. The colour parameters were not significantly different among the samples during storage. T1 samples maintained sensory qualities in flavour and off-odour parameters for two days longer than C samples did. At day 12, T2 samples were evaluated as being below the marketability score of 5.0 for texture. In conclusion, using high oxygen barrier films like EVOH/PE copolymer for packaging Hamburg steaks could extend the sensory qualities in view of flavour and off-odour during chilled storage. However, frozen storage at $-18^{\circ}C$ is recommended when the storage period is extended beyond 14 days at $5^{\circ}C$.