• 제목/요약/키워드: Pollution-resistance test

검색결과 46건 처리시간 0.025초

거북선 형상의 해상소각선 실용화 가능성에 관한 연구 (A feasibility study on the application of turtle boat form to the incinerating vessel)

  • 이귀주;최영빈
    • 한국해양공학회지
    • /
    • 제11권3호
    • /
    • pp.95-99
    • /
    • 1997
  • In these days, the pollution of marine environment near island at Korean coastal zone caused by the trash human waste and livestocks excreata become intensified. One of the most economic and efficient way to prevent this pollution problem is to set up island circulating incineration system. In this paper, the result of feasibility study on the application of turtle boat hull form to the incinerating vessel has been summarized especially for the resistance and course keeping point of view.

  • PDF

1액형 광촉매를 아스팔트 포장에 적용하기 위한 기초연구 (Fundamental Study on Applying an Integral TiO2 Solution to Asphalt Pavement)

  • 박재영;김영;김혁중;황용경;이재준
    • 한국도로학회논문집
    • /
    • 제19권1호
    • /
    • pp.53-62
    • /
    • 2017
  • PURPOSES : This research was a fundamental study on the application of an integral $TiO_2$ solution to asphalt concrete pavement. The integral $TiO_2$ solution was produced in pilot production equipment; application of the integral $TiO_2$ solution to asphalt pavement was conducted to examine the pollution-reducing capability of photocatalytic compounds such as $TiO_2$. The photocatalytic $TiO_2$ reacted with air pollutants, converting them into small amounts of relatively benign molecules. METHODS : In this study, laboratory experiments were conducted using five various testing methods. Tensile strength ratio (TSR) and British pendulum test (BPT) were conducted in order to evaluate the properties of asphalt pavement subsequent to the integral $TiO_2$ solution coating. In addition, methylene blue testing, a measurement of nitrate on the coated pavement, and nitrogen oxide (NOx) reduction testing were conducted in order to evaluate photocatalytic reaction. Lastly, a UV-A lamp was used as a light source for photocatalytic reactions. RESULTS : Test results indicated no change in the properties of asphalt pavement following the integral $TiO_2$ solution coating. In order to evaluate the performance of asphalt pavement as a function of $TiO_2$, the moisture susceptibility and skid resistance were investigated. The moisture susceptibility and skid resistance satisfied there quirements related to pavement quality and safety specification. Furthermore, the effects of reduction of air pollution were significantly improved as determined via the methylene blue test and NOx reduction test. The $TiO_2$-paved asphalt specimen exhibited approximately 43% reduction of NOx. CONCLUSIONS : This study has suggested that applying $TiO_2$ rarely impacts asphalt pavement performance measures such as moisture susceptibility and skid resistance, and that its application may be a better means of reducing air pollution. Further studies, such as proper $TiO_2$ dosage rates and compatibility with various pavement types, are required to broaden and generalize its application.

Multidrug resistance of coagulase-negative staphylococci isolated from rescued wild animals

  • Rhim, Haerin;Kim, Hong-Cheul;Na, Ki-Jeong;Han, Jae-Ik
    • 한국동물위생학회지
    • /
    • 제42권4호
    • /
    • pp.251-255
    • /
    • 2019
  • Wildlife is a bio-indicator of environmental pollution by antimicrobial resistant bacteria or genes, however, there is no information on antimicrobial resistance in wildlife-origin bacteria. This study aimed to investigate the normal microbiota of staphylococci and their antimicrobial resistance in wildlife that did not take any antimicrobials. After sampling and bacterial isolation/identification, antimicrobial resistance profiles were examined by broth microdilution test, Kirby-Bauer disc diffusion test and mecA genetargeted PCR. Of 90 isolates from wildlife, 83 were coagulase-negative staphylococci while only 7 were coagulase-positive staphylococci. Methicillin-resistance was found in 63 (70%) isolates and 35 of 90 (38.9%) isolates were multidrug-resistant staphylococci. When considering that all of the animals did not take any medication or contacted any medical device before the sampling, the results indicate significantly high prevalence of antimicrobial resistance in wild environments. Further study would be necessary to investigate the transmission route of antimicrobial resistance.

거북선 형상의 다목적 부유식 해상쓰레기 소각선 개발 (The Development of Turtle Boat Hull Formed Floating Type Multi-purpose Incinerating Vessel)

  • 이귀주;류태호;박원미
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.117-122
    • /
    • 2000
  • In these days, the pollution of marine environment near island at Korean coastal zone caused by the trash, human waste and livestocks excreta become series problem. One of the most economic and efficient way to prevent this pollution problem is to set up island circulating incineration system. In this paper, the results of feasibility study on the application of turtle boat hull form to the incinearting vessel has been summarized especially for the resistance and course keeping point of view.

  • PDF

합성 윤활유 및 고압 작동유 누출감지 필름형 센서의 구현 (Implementation of Film Type Sensor for Synthetic Lube Oil and High Pressure Hydraulic Fluid Leak Detection)

  • 박노진;유동근;유홍근
    • 센서학회지
    • /
    • 제23권4호
    • /
    • pp.266-271
    • /
    • 2014
  • Chemical sensors are used in various industrial facilities such high-risk and prevent the leakage of substances, important in life and environmental protection and the safe use of industry, used for management. In particular, high-temperature environments such as power generation equipment of the rotating part due to leakage generated by the various oil, power plants Shut Down, fire, work environment (exposure to various chemical solution and gas leak) and various water, air and soil pollution causes. Thus, over the long term through various channels such as crops and groundwater contamination caused by the slow, serious adverse effect on the ecosystem. In this paper, synthetic lube oil and high pressure hydraulic fluid leakage and immediately detect a new Printed Electronic implementation of technology-based film-type sensors, and its performance test. Thus, industrial accidents and environmental pollution and for early detection of problems, large accidents can be prevented. Experimental results of the synthetic lube oil and high pressure hydraulic fluid solution after the contact time depending on the experiment and the oil solution of the sensor material of the conductive porous PE resistance value by a chemical reaction could be confirmed that rapid increase. Also implemented in the film-type oil sensor electrical resistance change over time of the reaction rate and the synthetic lube oil is about 2 minutes or less, the high pressure hydraulic fluid is less than about 1 minute was. Therefore, more high-pressure hydraulic fluid such as a low volatility synthetic lube oils are the resistance change and the reaction rate was confirmed to be the slowest.

폐유리를 혼입한 콘크리트의 동결융해 저항성에 관한 실험적 연구 (An Experimental Study on the Freeze-Thaw Resistance of Concrete Containing Waste Glass)

  • 박승범;정명일;이봉춘;이준
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.593-598
    • /
    • 2002
  • Recently, as industrialization is rapidly growing and the standard of life is rising, the quantities of waste glasses have been hastily increased and most of them are not recycled but abandoned. It causes some problems such as the waste of natural resources and environmental pollution. Therefore, in this study freeze-thaw resistance test was conducted to analyze the properties of concrete containing waste glasses as fine aggregates and containing industrial by-products (fly ashes, silica fumes). As a results, it was found that freeze-thaw resistance decreases as the content of waste glasses increases. Also, the content of fly ash doesn't affect to the freeze-thaw resistance, and freeze-thaw resistance decreases with tile increase of silica fume contents.

  • PDF

일라이트와 이산화티탄을 활용한 콘크리트 블록의 수질환경개선을 위한 실험연구 (A Study on Experiment for Improvement of Water Quality in Concrete Block Using Illite and TiO2 Powder)

  • 허재원;강경수;김영수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권1호
    • /
    • pp.115-122
    • /
    • 2018
  • "일라이트와 이산화티탄을 활용한 콘크리트 블록의 수질환경개선을 위한 실험연구"를 진행하기 위해 모르타르 예비실험, 수질정화특성, 방오실험, 어독성 실험 및 실 콘크리트 블록 제조 후 관련 KS에 준한 실험을 진행한 결과 다음과 같은 결론을 얻었다. KS에 준한 콘크리트 블록의 성능평가 결과 전 조건에서 시험기준치의 압축강도를 상회하는 것으로 측정되었으며, 다공질구조의 일라이트 치환에 따른 흡수율 증가가 문제점으로 예상되었으나, 이산화티탄과 사전 혼합하여 치환함으로써 일라이트의 대형 공극내 이산화티탄이 정착함에 따라 흡수율 또한 문제가 없는 것으로 관찰되었다.

계면활성제가 첨가된 염수용액에 따른 폴리머 애자의 트래킹 성능 평가 (Tracking Performance Test of Polymer Insulator with Salt Solution which is added Surface Active Agent)

  • 조한구;이운용;한동희;강성화;최인혁;임기조
    • 한국전기전자재료학회논문지
    • /
    • 제18권1호
    • /
    • pp.62-67
    • /
    • 2005
  • Recently, polymer insulators that are used for high voltage applications have some advantages such as light weight, small size, vandalism resistance, hydrophobicity and easy making process. During outdoor service of polymer insulators, the surface of the insulating material is frequently subjected to moisture and contamination that lead to dry band arcing. Their tracking resistance, erosion resistance, end sealing and shed design are very important because dry band arcing causes degradation of polymer surface. Aging test to estimate life property of polymer insulator is executed through several international standard such as IEC 61109 and CEA tracking wheel test, but is not getting clear conclusion yet. There are two methods in the diagnosis method of polymer insulator such as off-line and on-line. The diagnosis methods in off-line are external condition analysis by the eye, contaminant analysis on surface, surface analysis, pollution withstand voltage test, power frequency flashover voltage test, lightning impulse flashover test, tensile fracture load test and flexural load test. Polymer material is also investigated it's tracking resistance by adding surface active agent in IEC 587. In this paper, the tracking performance of polymer insulator with salt solution which is added surface active agent. The diagnosis of insulator sample has been analyzed by leakage current and visual examination, STRI guide and thermal image camera.

옥외 애자용 재료의 표면 전기전도특성 (Properties of Surface Electrical Conduction in Materials for Outdoor Insulator)

  • 박영국;강성화;정수현;이운석;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.207-210
    • /
    • 1998
  • Surface electrical conduction in insulator is most important factor to assess the insulation performances of outdoor insulating materials. In this paper, contamination performance of the widely used materials for outdoor insulator - porcelain, EPDM, Silicone rubber - were discussed by measuring properties of average leakage current and scintillation discharge pulses under artificial contamination conditions. The artificial contaminations used were deionized distilled water fog, 0.5wt% NaCl salt fog of light pollution and 2wt% NaCl salt fog of medium pollution. The average leakage current was appeared linearly with applied voltage at dry and clean surface condition. The magnitude of leakage current was almost same at different kinds of samples. In case of deionized distilled water fog, the characteristics of leakage current and applied voltage was most different to that in case of dry and clean condition. In case of salt fog pollution condition. The leakage current was increased above critical voltage. The scintillation discharges were also activated at the level the leakage current and scintillation discharges were increased with increasing pollution degree. The resistance to pollution properties of silicone rubber appeared excellent among them.

  • PDF

폴리머 LP애자의 설계해석과 전기적 성능 시험 (The Design Analysis and Electrical Performance Test of Polymer LP Insulator)

  • 이운용;조한구;박상호;송홍준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.399-401
    • /
    • 2000
  • Recently polymer insulators are being used for outdoor high voltage applications. Polymer insulators for transmission and distribution line have significant advantages over porcelain and glass insulators, especially for ultra-high voltage(UHV) transmission lines. Their advantages are light weight, vandalism resistance and hydrophobicity. In this paper, polymer line post insulator has been designed and investigated electric field distribution by FEM. Designed LP insulators have been tested as insulator performance test, such as power frequency voltage test, lightning impulse voltage test, artificial pollution test and flexural load test.

  • PDF