• 제목/요약/키워드: Pollution method

검색결과 1,815건 처리시간 0.025초

폐광산 주변 토양 내 중금속의 연속추출법과 토양오염공정시험기준에 대한 비교 연구 (A study on the Comparison of the Heavy Metal in Abandoned mine Soil by Sequential Extraction Exthaction Methods)

  • 이종득;김태동;전기석;김휘중
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제16권6호
    • /
    • pp.95-105
    • /
    • 2011
  • Total extraction method and environmental standards for heavy metals in soils were revised in regulation recently. In case of Area 3, as the law amended, the soil pollution level has gone up to 4 to 13 times higher depending on the type of heavy metal. In this study, it compares the properties of heavy metals of soil by sequential extraction and total extraction methods depending on the analysis method, using the soil around mine. In case of arsenic, the soil pollution level has gone up to 4 times higher, but 6 to 10 times in the sample soil. Also, according to the results of portability evaluation depending on the type of existence form of heavy metal it exists as residual form in mine waste rock, which is less likely to move, while it exists as migrated form in tailing. Therefore, it should be considered to evaluate the soil pollution and decide the contaminated bounds depending on the existence form of heavy metals on soil to restore the polluted soil.

산업체 작업환경의 실내 공기에서 미생물 오염도 (Microbiologic Pollution of Indoor Air in Industrial Work-Places)

  • 강경희;장명웅
    • 생명과학회지
    • /
    • 제9권3호
    • /
    • pp.314-327
    • /
    • 1999
  • This study was investigated to isolate identify the total bacteria and fungi from the indoor air of work-place of the shoes, paint, stainless steel, and plastic industries. The number of bacterial colonies on the nutrient agar plates were calculated by the open petridish method for 30 minutes in indoor air of work-places at the autumn and winter. The isolated bacteria were identified by Gram stain and biochemical test using API Staph and API 20E kits. The isolated fungal colonies were identified by gross appearance of the giant colonies and microscopic examination of their spore and hyphal characteristics on the slide culture method. The minimum inhibitory concentration (MIC) of several antibiotics against isolated bacteria was determined by the microdilution method with Mueller-Hinton broth. The 70-400 colonies in autumn and 54-236 colonies in winter were isolated from the indoor air of work-places of several industry. The isolation rates of Gram positive cocci, Gram positive bacilli, Gram negative bacilli, and Gram negative cocci were 46.3%, 19.8%, 17.3%, and 16.1%, respectively. In Gram positive cocci, the most strains were identified as Aerococcus spp, Micrococcus spp, and Staphylococcus spp. In Gram positive and negative bacilli, and Gram negative cocci were identified as Bacillus spp, Pseudomonas spp, and Neisseria spp, respectively. The frequently isolated fungi were Aspergillus spp, Penicillium spp and Rhizopus spp, respectively. The frequently isolated Aerococcus spp, Micrococcus spp, and Staphylococus spp were highly resistance against ampicillin, erythromycin, methicillin, and tetracycline. These results arouse our attention to microbiologic pollution in the indoor air of work-places of industries.

  • PDF

항만의 온실가스 배출량 산정 및 공간할당 방법에 관한 연구 (A Study on Space Allocation Method and Calculation of GHGs Emissions in the Port)

  • 최상진;김정화;손지환;홍현수;한용희;김정수;조경두
    • 한국기후변화학회지
    • /
    • 제7권3호
    • /
    • pp.289-297
    • /
    • 2016
  • In this study, we researched the emission source category and it was calculated emissions estimates from existing research or literature review related to port. In addition, we have created the basis for a policy that can reduce greenhouse gas emissions calculation based on the results of the harbor. Greenhouse gas emissions estimation results, we proposed a method for allocating the GIS space. In this study, we confirmed based on the calculated greenhouse gas emissions by sources resulting in the GIS Map Port result of the expression construct for space allocation. Based on these results, it tries to provide the basic data that can be used when you want to create a local government measures to reduce scenario in the future.

국내 연근해 선박의 온실가스 배출량 공간할당 방법에 관한 연구 (A Study on Space Allocation Method of GHGs Emissions from Domestic Coastal Shipping)

  • 김필수;이종태;손지환;최상진;박성규;홍현수;김정수
    • 한국기후변화학회지
    • /
    • 제6권4호
    • /
    • pp.345-355
    • /
    • 2015
  • In this study, we researched a space allocation method of emissions from domestic coastal shipping (passenger ship, cargo ship, fishing boats). We were building a geographic information data that is used in GIS for emissions of space allocation, and presented a methodology capable of performing the space allocated for each grid by calculating the emissions. Passenger ships were assigned emissions of routes each the ship that operated at a fixed. Emissions of crusing mode of cargo ship, was equally assigned to the safe operation line, which is defined for domestic cargo ship. Also, Emissions of maneuvering (moving into or out of port) and hoteling (operations while stationary at dock), was assigned in consideration of anchorage in the major port. Fishing boat was evenly allocated monthly emissions in the country every month fishing grounds formation zone. Based on these results, it tries to provide the basic data that can be used when you want to create a local government measures to reduce scenario in the future.

울산시 초등학교 운동장의 토양오염실태에 관한 연구 (A Study on Soil Pollution of Elementary School Grounds in Ulsan City)

  • 차성웅
    • 한국학교보건학회지
    • /
    • 제21권2호
    • /
    • pp.89-95
    • /
    • 2008
  • Purpose: The purpose of this study is to investigate the heavy metal pollution of playgrounds of elementary schools in the Ulsan Metropolitan City. Soil pollution is one of the most dangerous problems of the utmost concern to both children and teachers. The result of this study would be an educational datum for improving children's health and establishing educational policy. Methods: For the analysis, fifteen representative schools were selected from five sample areas such as Dong-gu, Nam-gu, Jung-gu, Buk-gu and Ulju-gun of the Ulsan city. And from each school playground, soil was extracted from five spots and mingled into one sample. These fifteen samples were pretreated by the microwave extraction method, and the extracted heavy metals(As, Cd, Cu, Pb, Cr⁶⁺, Zn and Hg) were quantified by the ICP(Inductively Coupled Plasma) system. Results: The results of the analysis shows that the level of heavy metal pollution of elementary school playgrounds in Ulsan city did not exceed the permitted limit of each heavy metal. This means that the soil pollution of playgrounds in the Ulsan Metropolitan City is not so serious as it is expected. But it should be added that the soil is not too safe to be ignored.

수질오염도의 공간적 분포 변화 분석 : 한강 유역을 대상으로 (Spatial Distribution of the Levels of Water Pollutants in Han River)

  • 김광수;권오상
    • 자원ㆍ환경경제연구
    • /
    • 제18권1호
    • /
    • pp.105-138
    • /
    • 2009
  • 본 연구는 한강의 수질측정망에서 관측된 오염물질별 연평균 오염도를 이용하여 지난 15년 동안 수질오염도의 공간적 분포에 유의한 변화가 발생하였는지를 분석하였다. 구체적으로 각 오염물질별의 비모수적 커널확률밀도함수를 추정하였고, 연도간 유의한 변화가 있는지 검정하였다. 또한 일반화된 엔트로피 계열의 불평등지수를 구하고, 부트스트래핑 기법을 통해 불평등지수의 차이가 유의한지를 검정하였으며, 순위 상관을 이용하여 오염도 순위의 동태적인 측면을 분석하였다. 분석결과 최근 15년 동안 수질오염도의 불균등 정도는 전반적으로 완화되거나 일정한 수준을 유지하였고, 오염도 순위에 동태적인 변화는 거의 일어나지 않은 것으로 나타났다.

  • PDF

고형연료제품 사용시설에 따른 다환방향족탄화수소 (PAHs)의 배출특성 및 유해성 평가 (Emission Characteristics and Hazard Assessment of Polycyclic Aromatic Hydrocarbon (PAHs) from Solid Fuel Facilities)

  • 허선화;임승영;강대일;김대곤;전기준;장기원
    • 한국대기환경학회지
    • /
    • 제33권4호
    • /
    • pp.333-341
    • /
    • 2017
  • Recently, the earth has shown the limit of environmental capacity. It is also experiencing an environmental crisis with rising energy prices and depletion of coal. Therefore, development of renewable energy is very important solution. However, waste fuel solid are renewable fuels, but they cause environmental problems. In this study, the emission characteristics of hazardous air pollutants were analyzed through measurements at the facilities using solid fuels (SRF, BIO-SRF). Analysis method of PAHs are based on the Korea Standard Methods for Examination. The analysis of PAHs showed that the concentration much higher in Naphthalene, and Benzo(a)pyrene showed at a higher concentration incertain sources. As a result of gas phase and particle phase PAHs, most of Benzo(a)pyrene appeared to be particulate. Through the results of this study will provide basic data for atmospheric environmental management.

세라믹 기판위에 코팅된 기능성 필름의 열처리 분위기에 따른 내오염 및 기계적 특성 (Effects of Annealing Ambient on the Anti-Pollution and Mechanical Properties of Functional Film Coated on the Ceramic Substrate)

  • 선박문;강현일;최원석;정연호
    • 한국전기전자재료학회논문지
    • /
    • 제29권4호
    • /
    • pp.215-217
    • /
    • 2016
  • For the improvement of the anti-pollution properties of porcelain electrical insulators, in this study, we have applied the functional film to the surface of insulator. The functional films were coated on the ceramic substrates which components were like the porcelain electrical insulator. The coating material was applied to ceramic substrate by spray coating method and then the film was cured at around $300^{\circ}C$ for 10 minutes with different gas ambient, such as $O_2$, $N_2$, and only vacuum. We have measured the contact angle of the coated surface, and obtained the lowest angle ($8.9^{\circ}$) and a strong hydrophilic property at vacuum condition. The anti-pollution properties were measured, revealing that as the contact angle decreased, the anti-pollution properties improved. The mechanical hardness and adhesion were both excellent regardless of the annealing ambient.

폐기물 소각시설 최적가용기법 연계배출수준 (BAT-AEL) 설정 (BAT-AEL Calculation in Waste Incineration Facility)

  • 신수정;박재홍;이대균;김대곤;배연정
    • 한국대기환경학회지
    • /
    • 제34권1호
    • /
    • pp.144-155
    • /
    • 2018
  • As the public interest in environmental issues increased, the "Act On The Integrated Control Of Pollutant-Discharging Facility" was enacted. Through the integrated environmental pollution prevention act in which 19 industries with large environmental impacts are sequentially applied, pollutants can be managed in a medium-integrated manner and integrated permission of the business unit is possible and BAT can be applied to enable a scientific and proactive environmental management system. In addition, if the facility with BAT works normally, the pollutant emission is offered with the range of lower limit to upper limit. This study analyzed the overview of Best Available Techniques-Associated Emission Levels (BAT-AEL), and its setting procedure and method, and then suggested the BAT-AEL of a waste incineration facility. In comparative analysis on Emission Limit Values (ELVs) of EU, this study tries to propose improvement matters and development directions if the relevant standard is revised.

인공습지 형태에 따른 비점오염저감효율 분석 (Analysis for Removal Efficiency of Non-point Pollution Sources by Constructed Wetlands)

  • 이상혁;김이형;조혜진
    • Ecology and Resilient Infrastructure
    • /
    • 제1권2호
    • /
    • pp.102-108
    • /
    • 2014
  • 비점오염저감시설에 대한 연구는 활발히 진행되고 있으나, 도로에 자연형 비점오염저감시설 설치시 비점오염저감효율에 대한 연구는 없는 실정이다. 본 연구에서는 도로에 설치된 여러 종류의 인공습지에 대한 비점오염 저감효율을 모니터링과 유량가중평균농도법을 이용하여 분석하였다. 분석결과, 인공습지는 일반적인 오염물질인 TSS, COD, BOD, TN, TP에 대한 저감효율은 비교적 우수한 것으로 나타났으며 중금속인 Cr, Zn, Pb의 제거효율은 낮거나 거의 없는 것으로 나타났다.