• Title/Summary/Keyword: Pollution Source

Search Result 1,496, Processing Time 0.03 seconds

A Study on Inhalation Force Improvements of Ventilation Hood For Removed a Pollution Source (유해물질 제거를 위한 국소배기장치 후드의 흡입력 증가에 관한 연구)

  • Yang, Ho-Dong;Kim, Young-Sun;Oh, Yool-Kwon
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2327-2332
    • /
    • 2007
  • This study investigates on the inhalation force improvements of hood consisted one of the local ventilation systems attached the new device named as gas-guidance-device for removed a pollution source. The numerical method applying finite element method is calculated the velocity and pressure distributions of a moving fluid at the beginning and the inside of a hood with and without the gas-guidance-device in hood. And, the experimental study is measured the wind velocity using the anemometer at the same condition of numerical study. Also, the optimum shape of gas-guidance-device which is suitable for hood shape derived from the numerical and experimental results. The results of this study is supplied the important data to an industrial field for control of a pollution source in the engineering aspect. Moreover, the introduced technique of hood attached the gas-guidance-device is very useful to remove the harmful materials such as dust and waste happened in the manufacturing factory.

  • PDF

A Study for selecting the Highway Sites' Best Management Practice for Nonpoint Source Pollution (고속도로 현장별 비점오염 저감시설 선정방안 연구)

  • Lee, Yong-Bok;Choi, Sang-Il;Park, Kye-Su;Seong, Il-Jong;Jung, Sun-Kook
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.6
    • /
    • pp.857-866
    • /
    • 2011
  • This research categorized EIA target highways into following three types in order to minimize non-point source pollution from highway runoff. 1. Big drainage basin. 2. Small drainage basin. 3. Bridge section. The Natural, Filter and Swirl-Type devices were evaluated in terms of removal efficiency of TSS, BOD, COD, T-N, T-P, compatibility of site selection, economic feasibility, and maintenance convenience through which the final BMP was selected. According to the removal efficiency result, the area of Big and Small Drainage basin and bridge section had higher removal efficiency with natural facility than that of the Filter or Swirl-Type device. To make appropriate selection of highways'BMP for non-point source pollution, this study will aim to contribute to building more environmentally friendly highways by proposing the selection process that is made of 5 stages. 1. Selecting the target drainage basin. 2. Selecting the land for the mitigation facility. 3. Analysing the ease of maintenance. 4. Technically evaluating each installation. 5. Evaluating the effective implementation methods.

Application of vegetative filter strip to control nonpoint source pollution (비점원 오염관리를 위한 식생여과대의 적용)

  • Chung, Ji-Eun;Chung, Sang-Ok
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.417-420
    • /
    • 2002
  • Non-point source pollution of sediment, plant nutrients and pesticides from cropland has been identified as a significant environmental problem. Vegetative Filter Strips have been identified as one of BMPs to control nonpoint source pollution. This paper reviews the concept, functions, design criteria and management of VFS to control nonpoint source pollution.

  • PDF

Building an Integrated Governance Model and Finding Management Measures for Nonpoint Source Pollution in Watershed Management of Korea

  • Ban, Yong Un;Woo, Hye Mi;Han, Kyung Min;Baek, Jong In
    • Environmental Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.199-208
    • /
    • 2013
  • This study intended to develop an integrated governance model and find measures to manage nonpoint source (NPS) pollutions in watershed management. To reach this goal, this study has analyzed NPS pollution management policies in Korea and has employed statistical methods such as expert Delphi survey, analysis of variance, and factor analysis. As a result, this study has found that the favored basic organization form was a private-public cooperative council. The necessary governance-based NPS pollution management measures determined through this study are as follows: to build collaboration mechanisms including those related to motivation provision, trust building, capacity building, and making optimal regulations; to employ financial resources based on principles such as 'polluter-pays', 'recipient-pays', and 'general-tax-source'; and to develop several programs, including system improvement, pilot and management projects, and publicity.

Determination of EMC and Washoff Characteristics of Stormwater Runoff from Broad-Leaved Forest Areas (산림 활엽수 지역의 강우유출수 유출특성 및 EMC 산정)

  • Kang, Chang Guk;Lee, Soyoung;Gorme, Joan Barniso;Lee, Jea Un;Kim, Lee-Hyung
    • Journal of Environmental Impact Assessment
    • /
    • v.18 no.6
    • /
    • pp.393-399
    • /
    • 2009
  • The water of rivers and lakes are affecting by point and nonpoint source pollutions. The point source pollution can be controlled by establishing the treatment plants. However, nonpoint source pollution by various human activities is not easy to be controlled because it is difficult to determine the exits of the water flow and have many exit points. Due to contribution of nonpoint source pollution, the achievement ratio of water quality in rivers and lakes is not high. TMDL is the outstanding water quality control policy because all of the pollutant loadings from the watershed area are counting on the input loads. Our aqua-ecosystem has self-purification process by biological, physical and ecological processes. The self-purification process can remove the pollutant load from background concentrations. Usually forest area is main source of background concentrations. In Korea, about 70% of the national boundary area consists of mountains. This study is conducting as part of long-term monitoring to determine the Event Mean Concentration during a storm. The monitoring was performed on a broad-leaved tree area.

Design Model of Constructed Wetlands for Water Quality Management of Non-point Source Pollution in Rural Watersheds (농촌유역의 비점원 오염 수질관리를 위한 인공습지 설계모형)

  • 최인욱;권순국
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.5
    • /
    • pp.96-105
    • /
    • 2002
  • As an useful water purification system for non-point source pollution in rural watersheds, interests in constructed wetlands are growing at home and abroad. It is well known that constructed wetlands are easily installed, no special managemental needs, and more flexible at fluctuating influent loads. They have a capacity for purification against nutrient materials such as phosphorus and nitrogen causing eutrophication of lentic water bodies. The Constructed Wetland Design Model (CWDM), developed through this study is consisted mainly of Database System, Runoff-discharge Prediction Submodel, Water Quality Prediction Submodel, and Area Assessment Submodel. The Database System includes data of watershed, discharge, water quality, pollution source, and design factors for the constructed wetland. It supplies data when predicting water quality and calculating the required areas of constructed wetlands. For the assessment of design flow, the GWLF (Generalized Watershed Loading Function) is used, and for water quality prediction in streams estimating influent pollutant load, Water Quality Prediction Submodel, that is a submodel of DSS-WQMRA model developed by previous works is amended. The calculation of the required areas of constructed wetlands is achieved using effluent target concentrations and area calculation equations that developed from the monitoring results in the United States. The CWDM is applied to Bokha watershed to appraise its application by assessing design flow and predicting water quality. Its application is performed through two calculations: one is to achieve each target effluent concentrations of BOD, SS, T-N and T-P, the other is to achieve overall target effluent concentrations. To prove the validity of the model, a comparison of unit removal rates between the calculated one from this study and the monitoring result from existing wetlands in Korea, Japan and United States was made. As a result, the CWDM could be very useful design tool for the constructed wetland in rural watersheds and for the non-point source pollution management.

A Study on the Application of Agricultural Nonpoint Source Pollution(AGNPS) Model using GIS and RS (GIS와 RS를 이용한 비점원오염 모형의 적용에 관한 연구)

  • Kim, Seong-Joon;Lee, Yun-Ah;Lee, Nam-Ho;Yoon, Kwang-Sik;Hong, Seong-Gu
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.3 no.4
    • /
    • pp.63-72
    • /
    • 2000
  • The objective of this study was to identify the applicability of AGNPS(Agricultural Nonpoint Source Pollution) model using RS data; Landsat TM merged by KOMPSAT EOC and GIS data. AGNPS model which is well-known distributed nonpoint source pollution model was used as the assessment tool. This model has the capability to adjust the level of pollutant load from farmstead and the fertilization level of upland field. A small agricultural watershed($4.12km^2$) which has 20 livestock farmhouses located in Gosan-myun, Ansung-gun was selected. AGNPS data were prepared by using Arc/Info, GRASS, ER-Mapper and Idrisi. Four storm events in 1999 were used for runoff calibration, and 2 storm events which were measured in hourly-base at 4 locations along the stream were used for water quality(TN, TP) calibration.

  • PDF

Management Strategy for Soil and Groundwater Conservation (토양 및 지하수 보전을 위한 토양관리 및 대책방안)

  • 김경숙;정재춘
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.221-224
    • /
    • 1998
  • Environmental pollution is continuously increasing with the economic growth and industrial development. With this trend, soil and groundwater pollution problem has been surfaced as important social issues. Recently, Korean government promulgated the Soil Environment Conservation Act. But there are many problems to control sound soil quality management. Anthropogenic source of pollution such as waste landfill, pesticides, fertilizer, underground storage oil tanks is important as well as natural source such as acid rain and forest fire. The regulation should be expanded to include groundwater preservation as well as soil quality, because soil pollution is closely related to groundwater pollution. Therefore, legal regulations must be expanded to these facilities and take into account technical feasibility and finance.

  • PDF

Forecasting of Pollution Inflow of the Small Channel Catchment (소하천 유역에서의 오염 유입량 예측)

  • Kim, Dong-Phil;Jeon, Min-Woo;Yim, Dong-Hee
    • Journal of Environmental Science International
    • /
    • v.17 no.4
    • /
    • pp.451-459
    • /
    • 2008
  • This study was carried out forecasting of pollution inflow of the Small Mountainous Catchment, namely; Seolma-cheon experimental catchment. Pollutographs of DO, BOD, T-N, Conductivity, T-p, pH. COD, SS from this catchment were obtained from in-situ data of total ten events using QUAL2E-PULS model. From the analysis results, between up stream(Sabang-bridge) and down stream (Memorial-bridge, outlet) obtained relation formula of water quality component. Determination coefficient of relation formula, Conductivity, COD, BOD, DO, pH, T-N, T-P, and SS showed high relation of $0.87{\sim}0.99$. The increases of DO, BOD, COD, and pH concentration of Memorial-bridge were associated with pollution inflow by road building far 2.25km from Sabang-bridge to down stream. The analysis results of QUAL2E-PULS simulation and up/down stream relation formula, pollution amounts of DO, BOD, COD and pH increased at Memorial-bridge and pollution source site. Therefore, pollution inflow can be forecasted exactly by up/down stream relation formula at pollution source site.

Characteristics of Roadside Non-point Pollution and Applicability of Reduction Facilities in Paldang Water Source Protection Zone (팔당 상수원 보호구역내 도로비점오염의 특성 및 저감시설의 적용성 연구)

  • Cho, Hye Jin;Song, Meeyoung
    • Ecology and Resilient Infrastructure
    • /
    • v.7 no.4
    • /
    • pp.294-299
    • /
    • 2020
  • Based on the combined results of field surveys and analyses of the road structure and traffic flow, we propose a new plan for reducing roadside non-point pollution in the Paldang Water Source Protection Zone. The results show that the soil surrounding the roads in Paldang is highly permeable, which mitigates the need for filtration facilities. Roads flanked by steep slopes are found to facilitate the reduction of non-point roadside pollution through vegetation and soils along road slopes without the need for pollution reduction facilities. These results highlight the need for a flexible roadside non-point pollution reduction plan for roadside non-point pollution, which can be tailored to compliment relevant regulations and design standards after analyzing the characteristics of the target road.