• Title/Summary/Keyword: Pollution Source

Search Result 1,502, Processing Time 0.029 seconds

Air Pollutants Control Technique Trends for Transportation Sources in Korea (우리나라 이동오염원의 제어기술의 동향과 발전방안)

  • Kim, Jeong-Soo;Eom, Myung-Do
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.4
    • /
    • pp.477-485
    • /
    • 2013
  • The major source of harmful air pollutants in Korea have been shifted as economy grows. Particulate matter(PM) and Sulfur dioxide ($SO_2$) emitted from industries and coal-fired domestic sectors were important pollutants in 1970's and later industrializing period of Korea. Then the characteristic of pollution was changed into so-called "developed country type pollution". Vehicles have been responsible for significant amount of Nitric oxide ($NO_x$) pollution and consequent Ozone formation in urban area since 1990's. Variety of control measures have been introduced to deal with the vehicle emissions in Seoul Metropolitan Area (SMA). Emission control technologies have successfully reduced pollutants from vehicles. Three-way catalyst for vehicles fueled by gasoline and liquefied petroleum gas (LPG), for example, has achieved large amount of pollutants. Compressed natural gas (CNG) urban bus have penetrated existing diesel bus market and reduces PM and $NO_x$ emissions in many Korean cities. However, diesel vehicles are still reaming as a critical emission source of urban area. Diesel vehicles gain more popularity than ever because of their better fuel efficiency and driving power. Unfortunately, it is widely known that the pollutant emissions of diesel vehicles are much larger than those of gasoline and LPG vehicles. In this note, we briefly introduce the trends of emission control strategies which are accomplished by automotive industries for about last ten years. Emission regulation, cleaner fuel, diesel particulate filter (DPF) and other measures are discussed from technical as well as legislative perspectives.

Environmental Cost and Benefit Analysis Pollutant Reduction Facilities of the using the Emergy (Emergy를 이용한 오염물질 저감시설의 환경 비용/편익 분석)

  • Kim, Jin Lee;Hwang, Ha-Sun;Kim, Sang-Soo;Lee, Jae Kwan
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.5
    • /
    • pp.591-597
    • /
    • 2013
  • The input emergy of an advanced treatment plant for reducing the 1 kg of TN and TP was estimated 4.14E+14 sej/kg, 5.02E+15 sej/kg, respectively. In addition, the input emergy of constructed wetland for reduction of the 1 kg of TN and TP reduction was estimated to be 2.48E+14 sej/kg, 3.38E+15 sej/kg, respectively. The cost reducing 1 kg of TN and TP for an advanced treatment plant was estimated 197,466 won and 2,388,739 won respectively and constructed wetland was estimated 117,976 won and 1,609,213 won respectively. As a result, All of the emergy source of constructed wetland for reducing non-point source is renewable resource. If we use the constructed wetland, it results in enhancing economic value by reducing of non-point pollution, controlling a flood and providing the habitat of animals or plants. Improving water quality program in the Nakdong River Basin should be changed into an ecological treatment facilities from expansion of the sewage treatment facilities and advanced treatment plant using high cost and non-renewable energies.

Identifying Priority Area for Nonpoint Source Pollution Management and Setting up Load Reduction Goals using the Load Duration Curve (부하지속곡선을 이용한 비점오염원 우선관리 지역 선정 및 관리목표 설정 연구)

  • Jang, Sun Sook;Ji, Hyun Seo;Kim, Hak Kwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.5
    • /
    • pp.17-27
    • /
    • 2018
  • The objective of this study is to identify the priority area where the nonpoint source pollution (NPS) management is required and to set up the load reduction goals for the identified priority area. In this study, the load duration curve (LDC) was first developed using the flow and water quality data observed at 286 monitoring stations. Based on the developed LDC, the priority area for the NPS pollution management was determined using a three-step method. The 24 watersheds were finally identified as the priority areas for the NPS pollution management. The water quality parameters of concern in the priority areas were the total phosphorus or chemical oxygen demand. The load reduction goals, which were calculated as the percent reduction from current loading levels needed to meet target water quality, ranged from 67.9% to 97.2% during high flows and from 40.3% to 69.5% during moist conditions, respectively. The results from this study will help to identify critical watersheds for NPS program planning purposes. In addition, the process used in this study can be effectively applied to identify the pollutant of concern as well as the load reduction target.

Assessment of Air Quality Impact Associated with Improving Atmospheric Emission Inventories of Mobile and Biogenic Sources

  • Shin, Tae-joo
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.4 no.1
    • /
    • pp.11-23
    • /
    • 2000
  • Photochemical air quality models are essential tools in predicting future air quality and assessing air pollution control strategies. To evaluate air quality using a photochemical air quality model, emission inventories are important inputs to these models. Since most emission inventories are provided at a county-level, these emission inventories need to be geographically allocated to the computational grid cells of the model prior to running the model. The conventional method for the spatial allocation of these emissions uses "spatial surrogate indicators", such as population for mobile source emissions and county area for biogenic source emissions. In order to examine the applicability of such approximations, more detailed spatial surrogate indicators were developed using Geographic Information System(GIS) tools to improve the spatial allocation of mobile and boigenic source emissions, The proposed spatial surrogate indicators appear to be more appropriate than conventional spatial surrogate indicators in allocating mobile and biogenic source emissions. However, they did not provide a substantial improvement in predicting ground-level ozone(O3) concentrations. As for the carbon monoxide(CO) concentration predictions, certain differences between the conventional and new spatial allocation methods were found, yet a detailed model performance evaluation was prevented due to a lack of sufficient observed data. The use of the developed spatial surrogate indicators led to higher O3 and CO concentration estimates in the biogenic source emission allocation than in the mobile source emission allocation.llocation.

  • PDF

Homomorphic Subspace MAC Scheme for Secure Network Coding

  • Liu, Guangjun;Wang, Xiao
    • ETRI Journal
    • /
    • v.35 no.1
    • /
    • pp.173-176
    • /
    • 2013
  • Existing symmetric cryptography-based solutions against pollution attacks for network coding systems suffer various drawbacks, such as highly complicated key distribution and vulnerable security against collusion. This letter presents a novel homomorphic subspace message authentication code (MAC) scheme that can thwart pollution attacks in an efficient way. The basic idea is to exploit the combination of the symmetric cryptography and linear subspace properties of network coding. The proposed scheme can tolerate the compromise of up to r-1 intermediate nodes when r source keys are used. Compared to previous MAC solutions, less secret keys are needed for the source and only one secret key is distributed to each intermediate node.

A Study on the Relation between Riverbed Structure and Pollutant Concentration in Downstream of Nakdong River (낙동강 하류의 하상구조와 오염물질과의 상관관계 연구)

  • 황선출;정성욱
    • Journal of Environmental Science International
    • /
    • v.5 no.4
    • /
    • pp.481-494
    • /
    • 1996
  • This study was performed to investigate the relationship between concentrations of heavy metals in sediment and the depths of 27 sampling sites along the West Nakdong river in downstream of Nakdong River. The deepest site was Kangdong bridge nearby 20ft. From here, the depth was shallowed to Chidong gradually. In each site the smaller mesh was, the liger concentration of heavy metal becomed. Concentration of Zn, Cd, Cr and Cu at inflow point of Shinoe stream was 576.016 ppm, 262.307 ppm, 68.674 ppm and 61.634 ppm, respectively, the concentration was the higest at this point. From here, it was lowered gradually. The concentration of heavy metal at inflow point of Joman river was 155.328 ppm, 56.485 ppm, 25.200 ppm and 31.172 ppm, respectively, those concentrations were liger than other points with the exception of Shinoe stream. Therefore, woman river and Shinoe stream were the major source of pollution in West Nakdong river. Among two sources Shinoe stream was more important source of pollution. West Nakdong river has become lake by Noksan floodgate because it's pollution has had influence on Bonglim.

  • PDF

Development of an Expert Technique and Program to Predict the Pollution of Outdoor Insulators (옥외 절연물의 오손도 예측 기법 및 프로그램 개발)

  • Kim, Jae-Hoon;Kim, Ju-Han;Han, Sang-Ok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.28-34
    • /
    • 2007
  • Recently, with the rapid growth of industry, environmental condition became worse. In addition to outdoor insulators in seashore are polluted due to salty wind. Also this pollution causes the flashover and failure of electric equipments. Especially the salt contaminant is one of the most representative pollutants, and known as the main source of the accident by contamination. As well known, the pollution has a close relation with meteorological factors such as wind velocity, wind direction, temperature, relative humidity, precipitation and so on. In this paper we have statistically analyzed the correlation between the pollution and the meteorological factors. The multiple regression analysis was used for the statistical analysis; daily measured equivalent salt deposit density(dependent variable) and the weather condition data(independent variable) were used. Also we have developed an expert program to predict the pollution deposit. A new prediction system using this program called SPPP(salt pollution prediction program) has been used to model accurately the relationship between ESDD with the meteorological factors.

Comparative Analysis of Wastewater Management Technologies for Construction Sites (건설사업장의 수질관리 기술 적용사례 비교분석)

  • Yi, JongChan;Koo, Jakon
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.157-162
    • /
    • 2013
  • To deal with the water pollution arising from the construction site, this study raises the issues of management and laws and it suggest the efficient way to reduce water pollution by through the case studies. In order to study, seven cases were selected from "Construction Environmental Management Best Practice Competition" co - sponsored by Construction Association of Korea and Construction Environment Association. As a study result, there are problems that depending on the characteristic of the construction site environment simple alone settling facilities can not handle muddy and dirty water generated by the construction site. However, when the construction site applied improved water pollution control facilities with reflecting the characteristic of muddy and dirty water. The problem can be solved moreover it can achieve exceeded emission standard. Therefore new regulations and management with water pollution control facilities considering characteristic of environment is needed to cope with water pollution arising from the construction site.

HSPF Modeling for Identifying Runoff Reduction Effect of Nonpoint Source Pollution by Rice Straw Mulching on Upland Crops (볏짚 피복에 의한 밭 비점원오염 저감효과 분석을 위한 HSPF 모델링)

  • Jung, Chung-Gil;Park, Jong-Yoon;Lee, Hyung-Jin;Choi, Joong-Dae;Kim, Seong-Joon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.4
    • /
    • pp.1-8
    • /
    • 2012
  • This study is to assess the reduction of non-point source pollution loads for rice straw surface covering of upland crop cultivation at a watershed scale. For Byulmi-cheon watershed ($1.21km^2$) located in the upstream of Gyeongancheon, the HSPF (Hydrological Simulation Program-Fortran), a physically based distributed hydrological model was applied. Before evaluation, the model was calibrated and validated using 9 rainfall events. The Nash-Sutcliffe model efficiency (NSE) for streamflow was 0.62~0.78 and the NSE for water quality (Sediment, T-N, and T-P) were 0.68, 0.60, and 0.58 respectively. From the field experiment of 16 rainfall events, the rice straw covering reduced surface runoff average 10 % compared to normal surface condition. By handling infiltration parameter (INFILT) in the model, the value of 16.0 mm/hr was found to reduce about 10 % reduction of surface runoff. For this condition, the reduction effect of Sediment, T-N, and T-P loads were 87.2, 28.5, and 85.1 % respectively. The rice straw surface covering was effective for removing surface runoff dependent loads such as Sediment and T-P.

Changes in Stream Water Quality According to Land Use at Kyong-an Stream (京安川 流域의 土地利用에 따른 河川物質의 變化)

  • Yim, Yang-Jai;Bang, Je-Yong;Kim, Yoon-Dong
    • The Korean Journal of Ecology
    • /
    • v.18 no.3
    • /
    • pp.341-351
    • /
    • 1995
  • The relationship between land uses and water quality was investigated at Kyong-an Stream. Some 70% of this watershed was forested area, half of which was comprised of Pinus densilflora community. Concentrations of $NH_4^{+},\;NO_3^{-},\;NO_2^{-}, total nitrogen, $Cl^{-},\;PO_4^{3-}$, DO, and BOD increased gradually from upstream to downstream, whereas heavy metals did not have such tendancy with the exception of a few sites. Urban area was significantly correlated with hardness and chloride concentration. Relationship among phosphate concentration(P), cultivated field area(F), and stream length(S) in each basin was P = 1.7912 F/S+0.0103. the concentration of $NH_4^{+}$ was positively correlated with the population size and cow density within the catchment. The effect of urban area(U) and stream length of the pH(pH) was represented by pH = -4.7344 U/S+6.52. It can be concluded that the control of nonpoint source pollution as well as point source pollution is one of the important problems of water quality management, especially geological properties must be considered for sustainable development.

  • PDF