• Title/Summary/Keyword: Pollutants removal

Search Result 607, Processing Time 0.025 seconds

Development of Water Reusing System by Using Net3FM (Net Fit Fiber Filter Module) (그물망 압착식 섬유여과장치를 이용한 물 재이용 시스템 개발)

  • Kim, Jeongsook;Kim, Mi-Ran;Jo, Myung-Chan;Jang, Jeong-Gook
    • Journal of Environmental Science International
    • /
    • v.21 no.12
    • /
    • pp.1523-1528
    • /
    • 2012
  • This study was carried out to develop pilot plant Net3FM(Net Fit Fiber Filter Module) system and to suggest optimum operating condition for municipal wastewater reuse. SS concentration of biologically treated sewage effluent was reduced from 1.5~5.4mg/L to 0.4~1.0mg/L without coagulant injection in Net3FM system, and the SS removal efficiency was average 84.7%. And also, the removal efficiencies of COD and T-P were decreased slightly due to the SS removal by filtration. Coagulation-Filtration test was conducted to enhance the removal efficiencies of SS and T-P. The optimum dosage of coagulant was injected automatically by auto-controlling system, which is controlled by detecting value of turbidity of secondary sewage effluent. SS, COD and T-P concentrations in filtrated effluent were 0.21~0.57, 1.6~6.2 and 0.137~0.392mg/L with coagulant injection by in-line mixer in Net3FM system, respectively. The removal efficiencies of SS and T-P were highly increased to 92.8% and 89.8%, respectively. It was due to the combined the processes of coagulation and filtration. Net3FM system was evaluated that the removal efficiency of pollutants in secondary sewage effluent and the utilization potential as reclaimed water technology were very high.

Experimental investigation of aerosols removal efficiency through self-priming venturi scrubber

  • Ali, Suhail;Waheed, Khalid;Qureshi, Kamran;Irfan, Naseem;Ahmed, Masroor;Siddique, Waseem;Farooq, Amjad
    • Nuclear Engineering and Technology
    • /
    • v.52 no.10
    • /
    • pp.2230-2237
    • /
    • 2020
  • Self-priming venturi scrubber is one of the most effective devices used to collect aerosols and soluble gas pollutants from gaseous stream during severe accident in a nuclear power plant. The present study focuses on investigation of dust particle removal efficiency of the venturi scrubber both experimentally and theoretically. Venturi scrubber captures the dust particles in tiny water droplets flowing into it. Inertial impaction is the main mechanism of particles collection in venturi scrubber. The water injected into venturi throat is in the form of jets through multiple holes present at venturi throat. In this study, aerosols removal efficiency of self-priming venturi scrubber was experimentally measured for different operating conditions. Alumina (Al2O3) particles with 0.4-㎛ diameter and 3950 kg/㎥ density were treated as aerosols. Removal efficiency was calculated for different gas flow rates i.e. 3-6 ㎥/h and liquid flow rates i.e. 0.009-0.025 ㎥/h. Experimental results depict that aerosols removal efficiency increases with the increase in throat velocity and liquid head. While at lower air flow rate of 3 ㎥/h, removal efficiency decreases with the increase in liquid head. A theoretical model of venturi scrubber was also employed and experimental results were compared with mathematical model. Experimental results are found to be in good agreement with theoretical results.

Evaluation of refused tea waste activated carbon for color removal: Equilibrium and kinetic studies

  • Wijetunga, Somasiri;Gunasekara, Chathurika DFA
    • Advances in environmental research
    • /
    • v.6 no.1
    • /
    • pp.1-14
    • /
    • 2017
  • New technologies or improvement of the existing technologies are required to enhance the efficiency of removal of pollutants from wastewater. In this study we attempted to produce and test the activated carbon produced from the refused tea waste for the removal of dyes from wastewater. The objectives of this investigation were to produce activated carbon from refused tea waste by chemical activation, evaluate its performance for the removal of color produced from Acid Yellow 36, and the modeling of its dye removal with the kinetic study. The activation was performed in two steps namely carbonization at $375{\pm}25^{\circ}C$ and chemical activation with HCl at $800^{\circ}C$ under the absence of Oxygen. Adsorption isotherms and kinetic studies were performed with a textile dye, Acid Yellow 36, at different concentrations (20-80 mg/L). The maximum dye removal (~90%) observed at 80 mg/L dye concentration and it reduced at low dye concentrations. Maximum adsorption (71.97 mg/g) was recorded at 96 h at $29{\pm}1^{\circ}C$. Low pH increased the dye adsorption (pH=2; 78.27 mg/g) while adsorption reduced at high pH levels indicating that the competition occurs in between OH- ions and AY36 molecules for the adsorption sites in RTAC. The Langmuir isotherm model clearly explained the dye adsorption, favorably, by RTAC. Moreover, kinetic studied performed showed that the pseudo second order kinetic model clearly describes the dye adsorption. Based on the results obtained in this study, it can be concluded that RTAC can be used for the removal of textile dyes.

Treatment Efficiency of Pollutants in Constructed Wetlands under Different Hydroponic Wastewater Injection Methods and Characteristic of Filter Media (시설하우스 폐양액 주입방법 및 여재 특성에 따른 인공습지에서 수질오염물질의 처리효율)

  • Seo, Dong-Cheol;Park, Jong-Hwan;Cheon, Yeong-Seok;Park, Seong-Kyu;Kim, Ah-Reum;Lee, Won-Gyu;Lee, Sang-Won;Lee, Seong-Tae;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.29 no.2
    • /
    • pp.146-151
    • /
    • 2010
  • In order to improve T-N and T-P removal in HF (horizontal flow)-HF hybrid constructed wetlands by natural purification method for treating the hydroponic wastewater in greenhouses, the efficiency of water treatment as affected by the injection method of hydroponic wastewater, the addition of special filter media, the particle size of filter media, and the injection ratio of hydroponic wastewater in $1^{st}$ HF and $2^{nd}$ HF beds were investigated in small-scale HF-HF hydroponic wastewater treatment apparatus. Removal rate of T-P in the water in HF-HF hydroponic wastewater treatment apparatus with calcite as affected by addition method of special filter media was higher than that in HF-HF hydroponic wastewater treatment apparatus with other filter media. Removal rate of BOD, COD, SS, T-N and T-P in the water in mixed filter media with calcite were 86, 84, 87, 50 and 97%, respectively. Removals of pollutants except for T-P in the water were slightly different. Therefore, it should be considered that the removal rate of T-P was good for calcite in HF-HF hydroponic wastewater treatment apparatus. To improve T-N and T-P removal, the optimum particle size of filter media was 1.2 mm, and the optimum injection ratio ($1^{st}$ HF bed : $2^{nd}$ HF bed) of hydroponic wastewater was 60:40.

The Effect of Media Application in Aeration Tank for Aerobic Treatment of Swine Slurry (돈분뇨슬러리 폭기시 담체 설치효과)

  • Jeong, Kwang-Hwa;Choi, S.H.;Kwag, J.H.;Kim, J.H.;Jeong, E,S.;Jeong, M,S.;Kang, H.S.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.3
    • /
    • pp.167-174
    • /
    • 2010
  • This study was performed to evaluate the removal effects of nutritive salts and organic pollutants in experimental aeration reactor for treatment of piggery slurry. In this study, three types of reactors were manufactured and operated. The fibrous media was equipped in one of three reactors. Another reactor was equipped with the siliceous media and the other reactor used as a control was equipped with typical aeration system only. Treatment efficacy of three types of reactors were evaluated according to the pollutants removal rate of the piggery slurry. The results obtained in this study are as follows : 1) In the reactor containing fibrous media, the removal efficiency of BOD, T-N and T-P was 11%, 13.9% and 21.2%, respectively. 2) In the reactor containing siliceous media, the removal efficiency of BOD, T-N and T-P was 6.9%, 25.3% and 47.8%, respectively. 3) In the reactor not containing media, the removal efficiency of BOD. T-N and T-P was 6.1%, 8.1.% and 23.6%, respectively. 4) Sludge accumulation in the reactor equipped with filamentous media was lower than that of other experimental reactors.

Air Pollutant Removal Rates of Concrete Permeable Blocks Produced with Coated Zeolite Beads (코팅된 제올라이트 비드를 이용한 콘크리트 투수블록의 대기전구물질 제거율 평가)

  • Park, Jun-Seo;Yang, Keun-Hyeok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.2
    • /
    • pp.153-164
    • /
    • 2023
  • The objective of this study is to examine the removal rate of air pollutants, specifically sulfur oxides (SOx) and nitrogen oxides(NOx), using concrete permeable blocks containing zeolite beads coated with materials capable of eliminating these pollutants. Titanium dioxide(TiO2) powder and coconut shell powder were utilized for the removal of SOx and NOx and were applied as coatings on the zeolite beads. Concrete permeable block specimens embedded with the coated zeolite beads were produced using an actual factory production line. Test results demonstrated that the concrete permeable block containing zeolite beads coated with coconut shell powder in the surface layer achieved SOx and NOx removal rates of 12.5% and 99%, respectively, exhibiting superior performance compared to other blocks. Additionally, the flexural strength and slip resistance were 5.3MPa and 65BPN or higher, respectively, satisfying the requirements specified in KS F 4419 and KS F 4561. Conversely, the permeability coefficient exhibited low permeability, with grades 2 and 3 before and after contaminant pollution, according to the standard for 'design, construction, and maintenance of pavement using permeable block'. In conclusion, incorporating zeolite beads coated with coconut shell powder in the surface layer enables simultaneous removal of SOx and NOx, irrespective of ultraviolet rays, while maintaining adequate flexural strength and slip resistance. However, the permeability is significantly reduced, necessitating further improvements.

Removal of Air Pollutants Using Photosensitizers/Photocatalysts (감광제/광촉매에 의한 공기오염물질 제거)

  • Park, Ju-Hyoung;Ahn, Ki-Chang;Lee, Jae-Koo
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.4
    • /
    • pp.284-293
    • /
    • 2000
  • For the artificial removal of air pollutants such as pesticides, environmental toxicants, and pathogenic microorganisms in the greenhouse or the living environment, the accelerated photodegradation and the biocidal effects of some photosensitizers (PS)/photocatalysts (PC) were tested under the sunlight and/or artificial light. The selected photosensitizers/photocatalysts included the semiconductors (PC-1 and PC-2), the oxidizers (PC-3, PC-4, PC-5 and PC-6), the aromatic ketone (PS-7) and the aromatic amine (PS-8). In the case of dichlorvos, all the photocatalysts selected showed more accelerated photodegradation than the control without photocatalysts under both the sunlight and artificial light. Whereas, only the photocatalyst PC-1 accelerated the degradation of methyl tert-butyl ether about 17 times more than the control under both the sunlight and artificial light. Procymidone was much more degraded by the photosensitizer PS-8 and the two photocatalysts (PC-1, PC-6) than by PS-7. In the preliminary experiments to diminish the population of the microorganisms in the air, the photocatalyst PC-1 added to the suspensions of Pseudomonas putida, Phytophthora capsici, and Salmonella typhimurium obviously inhibited the microbial growth under the artificial light. The photocatalyst PC-1 showed a bactericidal activity against Salmonella typhimurium spread on the nutrient broth agar medium. These results suggest that the photosensitizers/photocatalysis under the light can remove some air pollutants and hence they can be used to reduce the exposure of the workers in the horticultural facilities and/or the public in the environment to the harmful pollutants.

  • PDF

Characteristics and Fate of Stormwater Runoff Pollutants in Constructed Wetlands (도시지역에 적용가능한 인공습지에서의 강우유출수 함유 오염물질의 거동과 특성)

  • Alihan, Jawara Christian;Maniquiz-Redillas, Marla;Choi, Jiyeon;Flores, Precious Eureka;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.19 no.1
    • /
    • pp.37-44
    • /
    • 2017
  • Nonpoint source (NPS) pollution continues to degrade the water quality. NPS pollutants signals high concerns against a sustainable environment. Low impact development (LID) is the leading management practice which regulates and treats stormwater runoff especially in highly impervious urban areas. Constructed wetlands are known to have efficient removal capability of NPS pollutants. Likewise, these LID facilities were intended to maintain the predeveloped hydrologic regime through series of mechanisms such as particle settling, filtration, plant uptake, and etc. In this study, the objective was to investigate the characteristics, fate and treatment performance of the two in-campus constructed wetlands (SW1 and SW2) which were installed adjacent to impervious roads and parking lots to treat stormwater runoff. A total of 42 storm events were monitored starting from July 2010 until November 2015. Manual grab sampling was utilized at the inlet and outlet units of each LID facilities. Based on the results, the wetlands were found to be effective in reducing 37% and 41% of the total runoff volume and peak flows, respectively. Aside from this, outflow EMCs were generally lower than the inflow EMCs in most events suggesting that the two wetlands improved the water quality of stormwater runoff. The average removal efficiency of pollutants in facilities were 63~79% in TSS, 38~54% in TN, 54% in TP and 32%~81% in metals. The results of this study recommend the use of constructed wetlands as efficient treatment facility for urban areas for its satisfactory performance in runoff and pollutant reduction.

Temperature-Dependent Effects of Pollutants on Biological Denitrification Process for Treating Cokes Wastewater (코크스폐수의 생물학적 탈질공정에 대한 독성물질의 온도에 따른 영향)

  • Kim, Young Mo;Park, Donghee;Ahn, Chi Kyu;Lee, Min Woo;Park, Jong Moon
    • Korean Chemical Engineering Research
    • /
    • v.46 no.6
    • /
    • pp.1124-1129
    • /
    • 2008
  • Cokes wastewater is one of the most toxic industrial effluents since it contains high concentrations of pollutants, such as phenol, ammonia, thiocyanate and cyanides. Although biological pre-denitrification process has been used to treat this wastewater in Korea, unexpected failure in nitrogen removal occasionally occurs during summer season. In this study, therefore, we examined inhibitory effects of phenol, ammonia, thiocyanate, ferric cyanide and free cyanide on biological denitrification according to temperature variation ($20{\sim}38^{\circ}C$). Batch experiments showed that denitrification rate was faster in summer ($38^{\circ}C$) than other seasons, and removal rates of pollutants increased with increasing temperature. Phenol, ammonia, thiocyanate and ferric cyanide did not inhibit denitrification even at its high concentration (200 mg/L). However free cyanide above 0.5 mg/L seriously inhibited the bilolgical denitrification reaction. Inhibitory effect of these pollutants was reduced with increasing temperature.

Simultaneous Removal of Gaseous and Particulate Pollutants in a Room With Optimal Ventilation System (최적 환기 시스템에 의한 실내에서의 가스 및 입자상 오염물의 동시 제거에 관한 연구)

  • 조용수;여석준
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.433-434
    • /
    • 2003
  • 급속한 산업 발전과 더불어 산업전반에 걸쳐 환경문제가 심각해지면서 생활의 질적 향상에 따른 쾌적 환경을 추구하기 위해 실내와 작업장 내에 떠 있는 먼지나 유해가스 등의 오염물질로 인한 직업성 질병에 대한 관심이 높아지고 있다 실내ㆍ외를 불문하고 환경오염이 인체 건강 및 위생에 미치는 영향은 오염물에 대한 노출시간에 관계하기 때문에 하루의 대부분의 시간을 실내에서 생활하는 현대인에게 실내 환경의 질은 아주 중요하다. 질의 물리적 특성에 따른 가스상, 입자상의 거동 및 농도분포에 대한 수치 해석적 연구는 매우 미흡한 실정이다. (중략)

  • PDF