• 제목/요약/키워드: Pollutant flux

검색결과 39건 처리시간 0.02초

Pollutant Flux Releases During Summer Monsoon Period based on Hydrological Modeling in Two Forested Watersheds, Soyang Lake

  • Kang, S.H.
    • Environmental Engineering Research
    • /
    • 제14권1호
    • /
    • pp.13-18
    • /
    • 2009
  • In this study, specific pollutant releases during the Asian monsoon season were estimated and the information was applied to the non-point pollutant sources management from two forested watersheds of the Soyang Lake. The two watersheds are part of the 2,703 km2 Soyang Lake watershed in the northern region of the Han River. The outlets of the two watersheds were respectively analyzed for continuous water quality concentration and for discharge during various single rainfall events. Statistical power function methods are utilized to compare stream discharge and pollutant flux release during the study period. Based on the monitoring data during the study period, the specific load flux method using simulated discharge was conducted and validated in the two watersheds. The model predictions corresponded well with the measured and calculated pollutant releases. The modeling approach taken in this study was found to be applicable for the two forested watersheds.

한강하류 오염부하의 유출특성 (Runoff Characteristics of Pollutant Loads of the Lower Han River)

  • 유호식
    • 상하수도학회지
    • /
    • 제26권3호
    • /
    • pp.479-486
    • /
    • 2012
  • Runoff characteristics of pollutant loads of the lower Han River was studied before full implementation of Total Pollution Load Management System(TPLMS). Magnitude of macroscopic(annual) fluctuation was in the order of Namhan River > Han River > Bukhan River, gross weight TP > gross weight TN > gross weight BOD, gross weight deviation > concentration deviation. Flux variation was higher than that of concentration. Microscopic(weekly) fluctuation showed similar pattern to macroscopic scale. TP showed the highest deviation resulting in the lowest reliability. 60% of annual flux passed during summer 3months resulting in 43-46% pass of gross weight at the lower Han River. Strong correlation was found between flux and gross weight especially in gross weight TN. Gross weight pollution increased as high as 400% while passing Seoul area due to the concentration. The deviation from moving average increased during summer season in the gross weight TP and BOD. Seasonal tendency was confirmed especially in gross weight TN and TP using autocorrelation function.

駕莫灣 流域의 汚染負荷 特性에 관한 硏究 (A Study on the Characteristics of Pollutant Loads in Kamak Bay Watershed)

  • 이대인;조현서
    • 한국환경과학회지
    • /
    • 제11권9호
    • /
    • pp.945-954
    • /
    • 2002
  • The objective okgf this study is understanding and evaluation of temporal and spatial variation of pollutant loads by input sources for water quality management in Kamak Bay. Flow rate of rivers and ditches ranges from about $2,592-63,072m^3/d$ in October to $864-55,296m^3/d$ in January. In particular, the R2 predominated flow rate among input sources. Total COD, BOD, DIN and DIP loadings in January were about 896kg/d, 718kg/d, 2,152kg/d, and 154kg/d, respectively, which exceeded those of October. Lower POC/TOC levels are estimated in R2, and also in October. Temporal variation of pollutant loads were closely related to the human activity. Total discharging loadings of BOD, TN and TP by unit loading estimation were 4,993.0kg/d, 2,558.7kg/d, and 289.2kg/d, respectively, and were mainly affected by the population. Runoff ratio of BOD was about 0.14 in January Mean $NH_4^+_-N$ and $PO_4\;^{3-}-P$ loadings from sediment were 16.23mg/$m^2$/d and 7.26mg/$m^2$/d, respectively. For the improvement of water quality in this area, not only pollutant loads of rivers and ditches but also benthic flux from sediment should be reduced within the limits of the environmental capacity.

간이변환 수질예측모델에 의한 영일만 내부생산성 평가 (Numerical Simulation of water quality by ${\Delta}COD$ method for Inner Productivity Estimation of Yeong-Il Bay)

  • 윤한삼;류청로;이인철;김헌태
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.99-104
    • /
    • 2003
  • This study investigated the yearly variation of pollutant loads outflowing from six watershed of Yeong-il Bay and compared the relationship of pollutant load and water quality, and estimated the Inner productivity of Yeong-Il Bay by using ${\Delta}COD$ method which analysis nonlinear process of water quality. As the estimated results for the pollutant loads of Yeong-Il Bay, total COD load outflowing from Hyeong-san river in flood season(summer) of 2001 year was 2275.0 kg/hr and in dry(low water) season(winter) 852.8 kg/hr, respectively. Load quantity in flood season was about 2.67 times than that in dry season. And as the calculated results of the net-flux of water for seven divisions, it showed that the net-flux of water increased for the divisions of the north coast and inner sea of Yeong-Il Bay but decreased for the south coast. On the contrary, for the cases which water quantity increase from land, the net-flux of water in estuary front of Hyeong-san river decreased but outflowing quantity of that though division of the south coast of Homi-got increased. Finally, this study compared the Inner productions for flood and dry season of Yeong-il Bay by using ${\Delta}COD$ method.

  • PDF

광합성과 증발산의 미기상학적 측정기술 (Technique for Estimating $CO_2$ and $H_2O$ Exchange between the Atmosphere and the Biosphere : Eddy Covariance Method)

  • Wonsik Kim
    • 한국농림기상학회:학술대회논문집
    • /
    • 한국농림기상학회 2003년도 춘계 학술발표논문집
    • /
    • pp.115-128
    • /
    • 2003
  • o What is the flux \ulcorner Flux is the transfer of a quantity per unit area per unit time. The quantities are mass, heat, moisture, momentum and pollutant in micrometeorology. Kinematic flux (Fluid). The reduction in wind speed due to frictional drag transfers momentum from the atmosphere to the surface, creating turbulence that mixes the air and transports heat and water from the surface into the lower atmosphere. (omitted)

  • PDF

Treatment of Saline Wastewater by the Activated Sludge with Nonwoven Fabric Separation

  • Moon, Byung-Hyun;Heo, Jong-Soo;Choi, Hyoung-Sub
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제2권2호
    • /
    • pp.136-140
    • /
    • 1997
  • Direct membrane separation using nonwoven fabric was applied to saline wastewater treatment by an activated sludge process. A nonwoven fabric module was immersed in an aeration tank. The part of treated was filtered through the module by suction and the rest of that was separated by a settling tank. Various F/M ratios and salt concentrations were applied to investigate stable flux as well as pollutant removal. The pollutant removal efficiencies of nonwoven fabric separation was not affected by F/M ratios and salt concentrations and was higher than that of settling tank separation. The decline in flux was seemed to be caused by the biofilm on nonwoven fabric surface.

  • PDF

광산배수 오염평가 기준도출에 관한 연구

  • 지상우;고주인;강희태;김재욱;김선준
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.382-385
    • /
    • 2003
  • QAMDI(Quantified Acid Mine Drainage Index) was developed for more synthesised, qualified and quantified assessment index which can be applied to both coal and metal mine drainage. QAMDI is calculated using three parameter groups i.e. acidity, sulfate contents and toxic metal contents. Since QAMDI expressed in terms of concentration. It reveals the different status of each mine drainage more clearly. QAMDI can be converted to the quantity of pollutant loading by being multiplied by the water flux.

  • PDF

WASP5에 의한 대청호 수질모델링 (Water Quality Modeling of Daechong Reservoir by WASP5/EUTR05 Model)

  • 이종호
    • 환경영향평가
    • /
    • 제8권1호
    • /
    • pp.93-105
    • /
    • 1999
  • Lately water quality of Daechong Reservoir has become more eutrophicated than ever before and there has been much concern over especially the eutrophication of the embayment near Daejon and Chongju Water Intake Tower every summer. The purpose of this study is to predict the impact of change in the pollutant loading, flowrate, nitrogen and phosphorus release from sediment, SOD(sediment oxygen demand) upon the water quality of Daechong Reservoir by WASP5/EUTR05 in order to suggest water quality management alternatives. The data of Sep. 1995 were used for the calibration of the model and those of Sep. 1997 was for verification. The result of the modeling can be summarized as follows. 1. The 50% increase(decrease) of pollutant loading has caused that of T-N concentration by 0.10-0.14 mg/l, T-P concentration by 0.003-0.005 mg/l, and CBOD concentration by 0.16-0.18 mg/l. But the ratio of DO change by the change of pollutant loading was relatively small. 2. The sensitivity test of NH4 flux to T-N and that of P04 flux to T-P shows that T-N and T-P concentration were changed more in the epilimnion segments (SEG4, SEG5, SEG6, SEG7) than the other segments. As SOD increases, DO was predicted to decrease more especially in the hypolimnion (SEG9-SEG14). 3. As flowrate increase, the concentration of T-N, T-P, and CBOD were predicted to decrease, but DO concentration increased especially in the hypolimnion segments(SEG11, SEG12, SEG13, and SEG14). As the flowrate changed from $119m^3/sec$ to $50m^3/sec$, the concentration of T-N and CBOD in the hypolimnion was predicted to decrease.

  • PDF