• Title/Summary/Keyword: Pollutant distribution

Search Result 295, Processing Time 0.024 seconds

Study on the Asymmetric Regional Deposition of Airborne Pollutant Particles in the Human Respiratory Tract (대기오염 입자의 인체 호흡기내 비대칭 국부침전 특성에 관한 연구)

  • 구재학;김종숭
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.5
    • /
    • pp.551-560
    • /
    • 2003
  • Particle deposition in human lungs was investigated theoretically by using asymmetric five-lobe lung model. The volumes of each of the five lobes were different, thereby forming an asymmetric lung structure. The tidal volume and flow rate of each lobe were scaled according to lobar volume. The total and regional deposition with various breathing patterns were calculated by means of tracking volume segments and accounting for particle loss during inhalation and exhalation. The deposition fractions were obtained for each airway generation and lung lobe, and dominant deposition mechanisms were investigated for different size particles. Results show that the tidal volume and flow rate have a characteristic influence on particle deposition. The total deposition fraction increases with an increase in tidal volume for all particle sizes. However, flow rate has dichotomous effects: a higher flow rate results in a sharp increase in deposition for large size particles, but decreases deposition for small size particles. Deposition distribution within the lung shifts proximally with higher flow rate whereas deposition peak shifts to the deeper lung region with larger tidal volume. Deposition fraction in each lobe was proportional to its volume. Among the three main deposition mechanisms, diffusion was dominant for particles < 0.5 ${\mu}{\textrm}{m}$ whereas sedimentation and impaction were most influential for larger size particles. Impaction was particularly dominant for particles> 8 ${\mu}{\textrm}{m}$. The results may prove to be useful for estimating deposition dose of inhaled pollutant particles at various breathing conditions.

Concentration Variations of Persistent Organic Pollutants in Gosan, Jeju during the Polluted Period in November 2001 and the Yellow Sand Period in Spring 2002 (2001년 11월 오염시기와 2002년 봄 황사시기 제주도 고산에서의 잔류성 유기오염물질 농도 변화)

  • 김영성;김진영;김연제;문길주;문광주;한진석;김상우;윤순창;권성안
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.5
    • /
    • pp.469-490
    • /
    • 2003
  • Atmospheric concentrations of persistent organic pollutants (POPs) were measured at Gosan, Jeju in November 2001 and spring 2002, each time for two weeks. Primary target pollutants were organochlorine pesticides, coplanar polychlorinated biphenyls (co- PCBs), and dioxin/furans listed in the Stockholm Convention adopted in May 2001. Polycyclic aromatic hydrocarbons (PAHs) were also measured in order to understand the overall characteristics of the POPs distribution as well as PM$_{2.5}$, a potent carrier of POPs. In the latter part of the measurement period of November 2001, almost every pollutant of combustion origin including dioxin/furans went high probably due to influence of emissions in the nearby area. The characteristics of atmospheric environment at Gosan in this period were rather close to urban areas far from those of a background area. A severe dust storm swept for three days at the end of the measurement period of spring 2002. However, changes in pollutant concentrations were relatively small except PM$_{10}$. Nevertheless, increases in particulate PAHs and OCDD (octachlorinated dibenzo-p-dioxins), mostly present in fine particles, were observed. Trends in organochlorine pesticide variations were mixed although possible volatilization of DDT residues from soil was inferred from the measurements of spring 2002.2.2.

Air Quality Deterioration in a Pristine Area due to a Petroleum Refinery and Associated Activities

  • Handique, Devolakshi;Bhattacharyya, Krishna G.
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.4
    • /
    • pp.254-269
    • /
    • 2017
  • The work describes an assessment of the major air pollutants, $NO_2$, $SO_2$, CO, $O_3$, $NH_3$, coarse and fine particulate matter ($PM_{10}$, $PM_{2.5}$) in ambient air in and around a 3 million tonne Petroleum Refinery and the possible impacts on a pristine area marked by the presence of the world-famous Kajiranga National Park, a world heritage site and habitat for the most number of one-horned rhinos in the world. The Refinery is at an aerial distance of 20-25 km from the wildlife habitat. The assessment is based on regular monitoring at four stations around the Refinery and one station near the National Park. Heavy rains during June to August influence the pollutant concentrations while at other times of the year, large traffic volume adds to the pollutant concentrations that peak during November to March, the dry months of the year. Correlation analysis by scatter technique is utilised to obtain the enhancement ratios to predict the variations in the concentrations of the pollutants and their spatial distribution. Computation of air quality index (AQI) indicates that the coarse and the fine particulates in the ambient air could be a major hazard to wildlife in the area.

Estimation of Air Pollutant Emissions for the Application of Photochemical Dispersion Model in the Seoul Metropolitan Area (광화학 확산모델 적용을 위한 수도권지역의 대기오염물질 배출량 산출)

  • 이종범;김용국;김태우;방소영;정유정
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.2
    • /
    • pp.123-135
    • /
    • 1997
  • An air pollutant emission inventory system for the input preparations of photochemical dispersion model was developed. Using the system, anthropogenic emissions as well as biogenic emissions in the Seoul metropolitan area were calculated. Anthropogenic emission by fuel combustion using regional cosumption data, and the laundries and so forth was estimated. The biogenic emission was estimated based upon meteorological data and the distribution of land use type in the study area. The anthropogenic emission of pollutants was highest in Seoul, and the second highest in Inchon. TSP and $SO_2$ were found large quantities during the winter due to increased consumption of heating oil. NOx and THC were emitted without seasonal variation. Among biogenic emissions, PAR was very common while NO was the least common. PAR, OLE, and ALD2 were emitted in large volumes in coniferous forest areas, while ISOP was emitted in deciduous forest areas. Generally, most biogenic emissions increased during daytime, and peaked between oen and two o'clock. Because of strong solar radiation, emission during the summer was high. Biogenic NO emissions were found to be lower compared to anthropogenic emissons, and other VOC was indicated relatively high. In the study area, among biogenic emissions PAR was found to be 3 times, OLE 8 times,and ALD2 12 times more common than among anthropogenic emissions.

  • PDF

Analysis of Non-Point Pollutants Outflow Pattern in Jinhae-Masan Basin (진해-마산만 유역에서 비점오염물의 유출양상 분석)

  • Lee, Beum-Hee
    • The Journal of Engineering Research
    • /
    • v.8 no.1
    • /
    • pp.107-118
    • /
    • 2006
  • The difficulties to build a 3-dimensional water quality model for the coastal water quality improvement and the environmental recovery estimation are the lack of periodic observed data and the many problems to observe continuously. I observed the rainfall and non-point pollutants outflow patterns in Jinhae-Masan basin as mid-step researches for the water quality simulation and management method development in a coastal area. I applied Landsat image system and Geographic Information System to analyze the runoff and non-point pollutants outflow patterns. A water quality simulation model (SWMM) applied to Jinhae-Masan basin with results of the land use distribution, non-point pollution loads, and watershed informations from GIS(IDRISI used). I proposed some improved survey and GIS application methods reflect upon the pollutant characteristics from the observed non-point pollutant outflow patterns.

  • PDF

Air Pollution Changes of Jakarta, Banten, and West Java, Indonesia During the First Month of COVID-19 Pandemic

  • PRAMANA, Setia;PARAMARTHA, Dede Yoga;ADHINUGROHO, Yustiar;NURMALASARI, Mieke
    • Asian Journal of Business Environment
    • /
    • v.10 no.4
    • /
    • pp.15-19
    • /
    • 2020
  • Purpose: This research aims to explore the level of air pollution in Jakarta, the epicenter of COVID-19 Pandemic in Indonesia and its surrounding provinces during the first month of the Pandemic. Research design, data and methodology: This study uses data, which have been obtained real time from API (Application Programming Interfaces) of air quality website. The measurements of Air Quality Index (AQI), temperature, humidity, and other factors from several cities and regencies in Indonesia were obtained eight times a day. The data collected have been analyzed using descriptive statistics and mapped using QGIS. Results: The finding of this study indicates that The Greater Jakarta Area experienced a decrease in pollutant levels, especially in the Bogor area. Nevertheless, some areas, such as the north Jakarta, have exhibited slow reduction. Furthermore, the regions with high COVID-19 confirmed cases have experienced a decline in AQI. Conclusions: The study concludes that the air quality of three provinces, Jakarta, Banten, and West Java, especially in cities located in the Jakarta Metropolitan Area during COVID-19 pandemic and large-scale social restrictions, is getting better. However, in some regions, the reduction of pollutant concentrations requires a longer time, as it was very high before the pandemic.

A Study on the Pollutant Reduction by Venturi Type After-burner (벤츄리형 후연소기의 오염물질 저감에 관한 연구)

  • Lee, Hwa-Sin;Lee, Yong-Hoo;Lee, Jin-Seok;Kwon, Oh-Boong;Lee, Do-Hyung
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.81-86
    • /
    • 2005
  • The purpose of this study is to develop venturi type after-burner in order to obtain pollutant reduction effect and find the best stable combustion condition. For this purpose, through a flow analysis, the shape of venturi type was made and flame holder locations were also decided by measuring chemical species at before and after the after-burner. Also, various chemical species concentration were measured at changing the induced air rates and the oxygen for oxygen enrichment for the solution the problems of much oxygen flow rate and the flame stability range. As results of this study, a flow distribution and the purification effect was excellent at venturi contraction 0.5 and flame holder location 12mm below the center of Venturi throat. On the purification characteristics, we found that pollutants reduction was effective when area ratio and oxygen are increased. But there are suitable quantities due to the flame shape change and combustion efficiency.

  • PDF

Spatial Distribution of Air Pollution in the Ulsan Metropolitan Region (울산지역 대기오염 공간분포)

  • Oh, Inbo;Bang, Jin-Hee;Kim, Soontae;Kim, Eunhye;Hwang, Mi-Kyoung;Kim, Yangho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.4
    • /
    • pp.394-407
    • /
    • 2016
  • The spatial air pollution distribution of the Ulsan metropolitan region (UMR) was analyzed using monitoring data and high-resolution numerical simulations. A three-year (2011~2014) analysis for the average concentrations from the 13 air quality monitoring sites in the UMR showed that $SO_2$ and $PM_{10}$ levels in industrial regions were much higher than those in other regions, whereas spatial differences of $NO_2$ and CO concentrations were not significant. In particular, elevated $O_3$ concentrations were clearly found at urban sites near petrochemical complex area. Results from high-resolution simulations by CMAQ model performed for four months of 2012 showed large spatial variations in grid-average pollutant concentrations between industrial areas and other areas in the UMR, which displayed significant changes with wind pattern by season. It was noted that the increases of $SO_2$ and $PM_{10}$ levels were limited in costal industrial areas or over the area nearby the sea in all seasons. Modeled $O_3$ concentrations were quite low in industrial areas and main urban roads with large $NO_x$ emissions. However, the model presented that all pollutant concentrations were significantly increased in the urban residential areas near the industrial complexes in summer season with increase of southerly wind.

Analysis of Efficient Pollution Reduction Facility using Pollutant Distribution Analysis (오염원 분포를 고려한 효율적 오염저감시설 적지분석)

  • Lee, Ji-Heon;Bae, Myung-Soon;Lee, Sang-Gil
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.465-469
    • /
    • 2008
  • 수도권의 중요한 상수원인 팔당호 수질에 큰 영향을 주고 있는 경안천 유역의 오염배출량을 저감하기 위하여 많은 인공습지조성이 계획되었으나 이들의 위치선정의 적합성에 대한 분석이 부족한 실정이다. 또한 경안천은 상류에서 중류까지는 주변 농경지의 용수공급을 위해 많은 수중보가 설치되어 물의 흐름이 단절되어있어 수리적 요소에 인공요인으로 작용하고 있으며, 하류로 갈수록 하천이 곡선형태로 흐르고 하폭 또한 넓어져 자체적으로 유기물이 증가하기 좋은 환경을 가지고 있다. 본 연구에서는 유역의 자연적, 인공적 요소를 고려한 물리적 모델을 구축하고 각 오염원특성별 부하량 분석을 통한 속성정보를 반영하였으며 오염저감시설설치 시나리오의 타당성분석을 분석을 수행하였다. 연구과정을 좀더 상세히 살펴보면 첫째, 비점오염원의 주된 경로중 하나인 축산계부하량 저감을 위하여 지형적 인자를 고려한 인공습지조성 적지분석 결과를 HSPF모델에 반영하였다. 둘째, 기존 오염 총량제에서 수행해오던 오염부하량 산정방식을 통해 산정된 양을 유역단위로 재분배 하여 오염원 분포를 반영하였다. 주요 오염부하량인 축산계와 토지계의 오염부하량만을 적용하였으며 일부 오염원 항목들은 생략하거나 하수처리시설을 통해 처리되고 있는 것으로 모의하였다. 셋째, 각 시나리오별 시뮬레이션을 수행하여 경안천 인공습지조성가능성 및 수질개선 효과를 예측하였다. 기존의 점오염원 처리시설만으로는 하천에서의 목표수질을 만족시키는데 한계가 있기 때문에 점오염원 저감시설뿐 아니라 비점오염원 저감시설인 인공습지를 기존의 처리시설에 연계하여 시나리오를 구성하였다. 기존습지시설의 오염저감율은 각 시설들의 평균값을 적용하였으며 처리효율은 BOD, TN, TP 각각 40%, 25%, 12%로 적용하였다. 오염원분포를 고려한 모의결과 현재 인공습지 입지대상지역들 중 좀 더 효율적인 오염저감 효과를 보이는 지역이 분석되었다.

  • PDF

An Experimental Study on the Separating Effect of Pulverized Coal at Coal Nozzle with Coal Separator (석탄 노즐내 미분탄 분리장치의 입자 분리 효과에 관한 실험적 연구)

  • Kim, Hyuk-Je;Song, Si-Hong;Lee, Gun-Myung;Kim, Sang-Hyeun;Lee, Ik-Hyung
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.764-769
    • /
    • 2001
  • Recently, according to increase in the requirement of electric power, a thermoelectric power plant equipped with pulverized coal combustion system is highly valued, because coal has abundant deposits and a low price compared with others. For efficient use of coal fuel, most of plant makers are studying to improve combustion performance and flame stability, and reduce pollutant emission. One of these studies is how to control the profile of particle injection and velocity dependant on coal nozzle. Basically, a mixed flow of gas and particle in coal nozzle is required to have appropriate injection and concentration distribution at exit to achieve flame stability and low pollutant, but it is very difficult to obtain that without help of a coal separating device within nozzle. In this study, each distribution of air and coal flow rate is measured for the coal nozzle with coal separator developed by us. The coal concentration at exit is various according to inlet swirl values and positions of coal separator. Also pressure drop is measured for various operating conditions of this nozzle. From these results, we can find the separation characteristic of new developed coal separator, and select proper operation range of coal nozzle. When this coal nozzle is applied to actual plant, these investigations will be very useful to confirm the shape of coal separator to have efficient particle injection.

  • PDF