• Title/Summary/Keyword: Pollutant distribution

Search Result 293, Processing Time 0.033 seconds

VOC/HAPs Emission Characteristics & Adsorption Evaluation for Paint Products in Busan Area (부산지역 페인트제조시설의 VOC/HAPs 배출특성 및 흡착능 평가)

  • Song, Bok-Joo;Lee, Seung-Min;Cho, Gab-Je;Cho, Jeong-Gu;You, Pyung-Jong;Kim, Gi-Gon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.5
    • /
    • pp.316-325
    • /
    • 2012
  • In this study, we suggested adequate control technology by analyzing emission process and main chemical of VOC/HAPs generated from four paint factories in Busan area. And we estimated whether Kapok fiber, which is a natural material, can be commercially used for an absorbent by testing adsorption ability. As a result of this sturdy, above 60% of VOC/HAPs was volatilized and dispersed inside the working place without conducting control system of facilities during manufacturing paints. Concentration profile of VOC/HAPs, which is volatile naturally outside the factories, is surveyed above 70% at Toluene, Ethylbenzene, and Xylene. And a result of evaluation of odor attribution level about the component whose Odor Threshold is known, it is estimated that major cause material of A, B, C factories is Toluene and that of D factory is m/p-Xylene. And that result presented design arguments such as facilities specifications, activated carbon filling volume, and replace cycle of activated carbon as control technology. Also, that result presented emission process improvement such as adsorption of central-controlled ventilation device, installation of inlet flenge, and potable cleaning process. The rate of pollutant adsorption of Kapok fiber, which is natural material, is indicated about 91.9%, 66.7%. That result validated the possibility as replacement of activated carbon.

A Study of Monitoring Method on Exposure Level and Biomarkers of Environmental Pollutants -Focused on Ulsan Industrial Complex Area- (지역주민 환경오염 노출수준 및 생체지표 모니터링 방법에 대한 연구 -울산지역을 중심으로-)

  • Lee, Jong-Tae;Cho, Yong-Sung;Son, Ji-Young;Lee, Joung-Won;Lee, Seung-Jun;Chung, Young-Hee;Kim, Dae-Seon;Yu, Seung-Do;Ahn, Seung-Chul
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.3
    • /
    • pp.188-198
    • /
    • 2008
  • Since 2003, the National Institute of Environmental Research (NIER) of Korea has been conducting "The monitoring study on exposure level and biomarkers of environmental pollutants" in the Ulsan industrial complex with the goals to establish a surveillance system for residents, to evaluate the health effects associated with chronic exposure to environmental pollutants and to develop the environmental health indicators in Ulsan industrial complex. This program consists of three phases an initial or foundation phase in which the program is developed, made operational and extended to the community, followed by an evaluation and accountability assessment of the surveillance system and finally an improvement in the quality of life and the maintenance of good health for Ulsan residents. In the period 2003 to 2008, the study program developed the surveillance system which will be used for the full-length survey. All participants in this study were contacted at a presentation meeting for residents, introduced to the objectives and protocols of the survey, and asked to participate. Informed consent was obtained from each participant. The study is now underway and includes questionnaires, health examinations and the analysis/collection/banking of bio-sample such as blood and urine. To date 828 subjects have participated and already 588 subjects have been followed up. We are committed to complete health examinations and to arrange storage of biosample for all participants. During the current year, we will analyze metals (Pb in blood and Cd, inorganic As and Hg in urine) in 1,972 samples and VOCs (11 species) and PARs (18 species) in 300 samples (blood sample). Moreover, the summary of the first step and the further preparation of the second step are currently underway. In this article, we introduce the study and its protocols and the distribution and size of the study participants. In conclusion, this survey will be continuously conducted on the established cohort and will enable the identification of relationship between environmental pollutant exposures and the health status of residents in Ulsan industrial complex.

Analysis of Rainfall Effect on the GIUH Characteristic Velocity (GIUH 특성속도에 대한 강우의 영향 분석)

  • Kim, Kee-Wook;Roh, Jung-Hwan;Jeon, Yong-Woon;Yoo, Chul-Sang
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.4
    • /
    • pp.533-545
    • /
    • 2003
  • This study analyzed several storm events observed in the Seolma-chun basin to derive the characteristic velocity of GIUH (Geomophological Instantaneous Unit Hydrograph) as well as its variability. Especially, this study focused on the variation of characteristic velocity due to the change of rainfall characteristics. The IUH of the Seolma-chun basin was derived using the HEC-1, whose peak discharge and time were then compared with those of the GIUH to derive the characteristic velocities. The characteristics velocities were analyzed by comparing with the GcIUH (Geomorphoclimatic IUH) as well as the characteristics of rainfall. Results are summarized as follows. (1) The characteristic velocity of GIUH was estimated higher with higher variability than the GcIUH, but their trends were found similar (2) Total amount of effective rainfall (or, mean effective rainfall) well explains the characteristic velocity of GIUH. This could be assured by the regression analysis, whose coefficient of determination was estimated about 0.6. (3) The duration and the maximum intensity of rainfall were found not to affect significantly on the characteristic velocity of GIUH. The coefficients of determination were estimated less than 0.3 for all cases considered. (4) For the rainfall events used in this study, the characteristic velocities of GIUH were found to follow the Gaussian distribution with its mean and the standard deviation 0.402 m/s and 0.173 m/s, respectively. Most of the values are within the range of 0.4∼0.5 m/s, and its coefficient of variation was estimated to be 0.43, much less than that of the runoff itself (about 1.0).

Prediction System of Hydrodynamic Circulation and Freshwater Dispersion in Mokpo Coastal Zone (목포해역의 해수유동 및 담수확산 예측시스템)

  • Jung, Tae-Sung;Kim, Tae-Sik
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.11 no.1
    • /
    • pp.13-23
    • /
    • 2008
  • In coastal region, eutrophication, Do deficit and red tide are frequently occurred by influx of fresh water. When the fresh water containing pollutants is discharged into the sea, the surrounding water is contaminated by dispersion of freshwater flowing into coastal waters. The prediction and analysis about the dispersion process of the discharged fresh water should be conducted. A modeling system using GUI was developed to simulate hydrodynamic flow and fresh water dispersion in coastal waters and to analyze the results efficiently. The modeling module of the system includes a tide model using a finite element method and a fresh water dispersion model using a particle-tracking method. This system was applied to predict the tidal currents and fresh water dispersion in Mokpo coastal zone. To verify accuracy of the hydrodynamic model, the simulation results were compared with observed sea level and time variations of tidal currents showing a good agreement. The fresh water dispersion was verified with observed salinity distribution. The dispersion model also was verified with analytic solutions with advection-diffusion problems in 1-dimensional and 2-dimensional simple domain. The system is operated on GUI environment, to ease the model handling such as inputting data and displaying results. Therefore, anyone can use the system conveniently and observe easily and accurately the simulation results by using graphic functions included in the system. This system can be used widely to decrease the environmental disaster induced by inflow of fresh water into coastal waters.

  • PDF

추적자를 이용한 오염물질 거동분석

  • Kim, Gi-Cheol;Lee, Jong-Seok;Lee, Jae-Cheol;Kim, Yun-Ho;Yeon, Gi-Heum
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2008.05a
    • /
    • pp.289-293
    • /
    • 2008
  • In this study, in order to find out the movement of polluted substance that is flown into the river and the characteristics of dispersion, the experiment that used the RI (Radio Isotope) tracer in the river was undertaken, and by using the experiment result, the figure modelling was undertaken to analyze the general type of pollutant dispersion. In addition, in order to calculate more accurate dispersion range and moving time, the experiment was done in about 2km from the measuring points of Namdaecheon around the Yongdam Dam of the upper Geum River to the lower stream, and modeling was undertaken for the 20km zone from the measuring points to the lower stream. In order to find out the flow of river and dispersion of polluted substance, RMA (Resource Modeling Associates)-2 and RMA-4 program are used in study. The site experiment using the RI was implemented for the experiment in the applied area and the same area, and the distance between each zone was set for 1㎞ with the slight difference for site situation and measured the density date of one second distance through the NaI apparatus to measure the density data of one second interval. On the basis of this measured data, it is compared and analyzed with the result of figure copy of RMA-2 and RMA-4 models to make the comparison and analysis of density distribution following the change in expansion coefficient that makes great influence on expansion range and dispersion in natural rivers. The influence of expansion coefficient on river can be researched and the measured density data, the maximum and minimum density time, and the basic data to calculate the expansion coefficient was prepared in this study.

  • PDF

A Study of Indoor Air Quality of Public Facilities in Chung-Nam Area (충남지역 미적용 다중이용시설의 실내공기질에 관한 연구)

  • Hong, Sung-Chul;Jou, Hye-Mee;Cho, Tae-Jin;Lee, Che-Won;Jung, Yong-Taek;Son, Bu-Soon
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.2
    • /
    • pp.35-45
    • /
    • 2008
  • In order to recommend criteria for the administration law on indoor air quality, this study was conducted to examine the distribution and the concentration of indoor air pollutants ($PM_{10},\;CO_2$, CO, HCHO, TBC, $NO_2$, Rn, VOCs, asbestos, $O_3$) in public facilities in the Chung-Nam area. The concentrations of indoor air pollutants were obtained from sixty seven public facilities such as a cinema, an office, a restaurant, a theater and an academy. This study was performed from August to December, 2005. The results of this study showed that the concentrations of indoor air pollutants such as $PM_{10},\;CO_2$, CO, HCHO, TBC, Rn and $O_3$ were less than the recommended limits. However, the average concentration of VOCs was $521.73{\mu}g/m^3$ (GM : $221.69{\mu}g/m^3$), which was higher than the recommended limit of $400{\mu}g/m^3$. Moreover, the average concentration of $NO_2$ was 345.66ppb (GM : 69.95ppb), which was higher than the recommended limit of 50 ppb. The correlation between the concentrations of indoor air pollutants and the type of facilities with respect to $CO_2$, TBC and Rn was statistically low (p<0.05). However, the correlation was high in terms of the CO and $O_3$ concentrations (p<0.01). No relationship between the indoor air pollutants and the type of facilities was observed for $PM_{10}$, VOCs and $NO_2$. The year of construction was compared to the concentrations of indoor air pollutants. Specifically, when the construction date was less than 3 years, the HCHO, VOCs and TBC concentrations were $44.75{\mu}g/m^3,\;555.07{\mu}g/m^3$ and $337.79CFU/m^3$, respectively. These concentrations were $120{\mu}g/m^3$ and $211.84CFU/m^3$ higher for VOCs and TBC than the concentrations obtained from the facilities more than 3 years. However, the concentration of HCHO was similar between the facilities older and younger than 3 years of age. Year, temperature, humidity and indoor air pollutant correlation analyses showed that temperature and humidity, temperature and TBC, temperature and $O_3,\;PM_{10}$ and $NO_2$, HCHO and VOCs, $CO_2$ and Rn had positive relationships. However temperature and Rn, humidity and $CO_2,\;CO_2$ and $O_3,\;O_3$ and Rn had negative relationships. Accordingly, it will be necessary to manage the factors affecting indoor air quality so that the residents can have a more comfortable and healthier living environment. Ultimately, the results of this study are expected to be utilized as baseline data.

Distributional characteristics of Escherichia coli based on seasonal rainfall variations and extension of freshwater pollutant sources by salinity gradients at Ulsan Bay of Korea facing East Sea (동해 울산만에서 계절적 강우변화와 담수기원 오염원이 염분구배 및 유역별 대장균 분포에 미치는 영향)

  • Lee, Minji;Baek, Seung Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.632-640
    • /
    • 2017
  • In order to understand the seasonal and geographical characteristics of environmental factors and distribution of Escherichia coli by salinity gradient due to precipitation, we investigated abiotic and biotic factors during four seasons from February 2013 to November 2015. The study area was divided into three different zones based on salinity gradient and geo-oceanographic characteristics. During the study period, water temperature, salinity, Chlorophyll a, and secchi-depth varied in the range of $8.5-26.1^{\circ}C$, 13.5-34.4 psu, $0.4-74.0{\mu}g\;L^{-1}$, and 0.5-10.0 m, respectively. Salinity was low at Zone I, which was influenced by water flux from Tae-hwa River, especially in 2014. Salinity was gradually increased (one-way ANOVA; p < 0.05) toward Zone III located offshore of the bay. The highest colony form of E. coli was detected at Zone I. E. coli maintained a relatively low level at Zone III during all seasons. E. coli was correlated with transparency (r = -0.36; p < 0.05) and salinity (r = -0.53; p < 0.01), implying that those parameters might play important roles in the proliferation of E. coli. These results indicated that E. coli were strongly affected by frequent rain (< 50 mm) around inner stations in Ulsan Bay of Korea.

Monitoring of non-point Pollutant Sources: Management Status and Load Change of Composting in a Rural Area based on UAV (UAV를 활용한 농촌지역 비점오염원 야적퇴비 관리상태 및 적재량 변화 모니터링)

  • PARK, Geon-Ung;PARK, Kyung-Hun;MOON, Byung-Hyun;SONG, Bong-Geun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.2
    • /
    • pp.1-14
    • /
    • 2019
  • In rural areas, composting is a source of non-point pollutants. However, as the quantitative distribution and loading have not been estimated, it is difficult to determine the effect of composting on stream water quality. In this study, composting datum acquired by unmanned aerial vehicle(UAV) was verified by using terrestrial LiDAR, and the management status and load change of the composting was investigated by UAV with manual control flight, thereby obtaining the basic data to determine the effect on the water system. As a result of the comparative accuracy assessment based on terrestrial LiDAR, the difference in the digital surface model(DSM) was within 0.21m and the accuracy of the volume was 93.24%. We expect that the accuracy is sufficient to calculate and utilize the composting load acquired by UAV. Thus, the management status of composting can be investigated by UAV. As the total load change of composting were determined to be $1,172.16m^3$, $1,461.66m^3$, and $1,350.53m^3$, respectively, the load change of composting could be confirmed. We expect that the results of this study can contribute to efficient management of non-point source pollution by UAV.

Leachate Concentration to Groundwater Considering Source Depletion for Risk Assessment in Vadose Zone of Contaminated Sites (오염부지 위해성평가 시 불포화대 오염원 고갈을 고려한 토양유출수 농도 결정)

  • Chang, Sun Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.583-592
    • /
    • 2020
  • This study assessed source depletion in the vadose zones of contaminated sites. The possible range of infiltration rate in Korea was statistically analyzed. The results showed a trend of decreasing leachate concentration of 13 pollutants used for risk assessment. Among them, benzene, ethylbenzene, toluene, and xylene showed a lower leachate concentration in groundwater over time due to their low distribution coefficient and also possible biodegradation effects. The average values of the relative concentration could be taken as a default index due to a very small range of uncertainties. In the case of heavy metals, it was shown that the leachate concentration in a pollutant does not decrease over time. Considering the annually different infiltration, a site-specific source-depletion scenario was applied to Cheongju in North Chungcheong Province. The result was expressed as a time series of the relative concentration of the leachate concentration, and this was compared to the trend by averaged Korean infiltration. Finally, an open-source code that used Python was used to help calculate the leachate concentration by this site-specific infiltration scenario.

Characteristics of RDF Char Combustion in a Bubbling Fluidized Bed (기포 유동층 내에서 RDF 촤의 연소 특성)

  • Kang, Seong-Wan;Kwak, Yeon-Ho;Cheon, Kyoung-Ho;Park, Sung Hoon;Jeon, Jong-Ki;Park, Young-Kwon
    • Applied Chemistry for Engineering
    • /
    • v.22 no.4
    • /
    • pp.429-432
    • /
    • 2011
  • The feasibility of applications of the char obtained from a gasification process of municipal-waste refuse derived fuel (RDF) as an auxiliary fuel was evaluated by combustion experiments. The higher heating value of the RDF char was 3000~4000 kcal/kg and its chlorine content was below the standard requirement demonstrating its potential as an auxiliary fuel. In the combustion exhaust gas, the maximum $NO_x$ and $SO_2$ concentrations were 240 ppm and 223 ppm, respectively. If an aftertreatment is applied, it is possible to control their concentrations low enough to meet the air pollutant emission standard. The HCl concentration was relatively high indicating that a care should be taken for HCl emission from the combustion of RDF. Based on the temperature distribution within the reactor, the concentration change of $O_2$ and $CO_2$, and the amount and the loss on ignition of solid residue, it was inferred that the combustion reaction was the most reliable when the excess air ratio of 1.3 was used.