• 제목/요약/키워드: Pollutant concentrations

검색결과 541건 처리시간 0.026초

2006~2015년 동안 국내 유해화학물질 배출량 변화에 관한 연구 (A Study on the Variation of Hazardous Pollutant Emissions in Korea from 2006 to 2015)

  • 임지영;김현지;김민선;이지호;이상목;이청수
    • 한국환경보건학회지
    • /
    • 제44권1호
    • /
    • pp.15-23
    • /
    • 2018
  • Objectives: The purpose of this study was to investigate the changes in hazardous pollutant emissions in Korea over the period of 2006-2015. Methods: A survey of hazardous pollutant emissions was conducted through the homepage for 2006-2015. The emission of hazardous chemicals and the health effect was examined using the Annual Report of Air Quality in Korea (2016) and National Health Statistics (2015) as references. Results: Hazardous pollutant emissions increased by 1.1 times over the past decade, and the circulation amount of chemicals was 15% compared to the previous year. $PM_{10}$ concentrations showed a tendency to decrease, but emissions have not declined. In addition, asthma and atopic dermatitis correlated with similar emissions, but allergic disease showed no connection. Conclusion: These results on hazardous pollutant emissions indicate that they have increased. However, no association between emissions and health effects was shown, so more research is needed.

Evaluation of urban pollutant washoff characteristics and treatment efficiency of a small constructed wetland

  • Reyes, Nash Jett DG.;Geronimo, Franz Kevin F.;Kim, Lee-Hyung
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2019년도 학술발표회
    • /
    • pp.412-412
    • /
    • 2019
  • Nature-based solutions (NBS) offer a wide variety of techniques that promote cost-efficient stormwater management practices. In particular, low impact development facilities utilize NBS principles to restore the ecosystem services in a highly-urbanized area. Despite the advancements in these technologies, several considerations should still be addressed to ensure optimum functionality and attainment of desired pollutant removal efficiency a LID facility. This study evaluated the mass flushing characteristics of pollutants in an urban catchment and the efficiency of a small constructed wetland (SCW) in treating urban stormwater runoff. 21 rainfall events from 2010 to 2018 were monitored to determine and quantify stormwater pollutants. The highest pollutant washoff was observed on rainfall depths ranging from 0.1mm to 10mm, whereas events with greater rainfall depths exhibited lower pollutant concentrations due to dilution effect. However, the SCW manifested lower pollutant-removal performance on rainfall depths exceeding 10mm due to the exceedance of the facility's design rainfall. This study is beneficial in assessing the dynamics of pollutant washoff and efficiency of LID facilities subjected under various external factors.

  • PDF

확인적 요인모형을 이용한 낙동강 유역의 오염특성 분석 (Analysis of Pollutant Characteristics in Nakdong River using Confirmatory Factor Modeling)

  • 김미아;강태구;이혁;신유나;김경현
    • 한국물환경학회지
    • /
    • 제28권1호
    • /
    • pp.84-93
    • /
    • 2012
  • The study was conducted to analyze the spatio-temporal changes in water quality of the major 36 sampling stations of Nakdong River, depending on each station, season using the 17 water quality variables from 2000 to 2010. The result was verified to interpret the characteristics of water quality variables in a more accurate manners. According to the Principal component analysis (PCA) and Exploratory factor analysis (EFA) results; the results of these analyses were identified 4 factors, Factor 1 (nutrients) included the concentrations of T-N, T-P, $NO_{3}-N$, $PO_{4}-P$, DTN, DTP for sampling station and season, Factor 2 (organic pollutants) included the concentrations of BOD, COD, Chl-a, Factor 3 (microbes) included the concentrations of F.Coli, T.Coli, and Factor 4 (others) included the concentrations of pH, DO. The results of a Cluster analysis indicated that Geumhogang 6 was the most contaminated site, while tributaries and most of the down stream sites of Nakdong River were mainly affected by each nutrients (Factor 1) and organic pollutants (Factor 2). The verification consequence of Confirmatory factor analysis (CFA) from Exploratory factor analysis (EFA) result can be summarized as follows: we could find additional relations between variables besides the structure from EFA, which we obtained through the second-order final modeling adopted in CFA. Nutrients had the biggest impact on water pollution for each sampling station and season. In particular, It was analyzed that P-series pollutant should be controlled during spring and winter and N-series pollutant should be controlled during summer and fall.

도로청소 수거퇴적물의 특성과 비점오염물질 저감효과 (Characteristics of Collected Sediments from Road Sweeping and Reduction in the Nonpoint Source Pollutants Loading)

  • 정권;강희만;고석오
    • 한국도로학회논문집
    • /
    • 제13권2호
    • /
    • pp.187-193
    • /
    • 2011
  • 도로에서의 강우유출수 내 포함된 오염물은 주요한 비점오염원으로 간주되고 있으며 비점오염물질 저감을 위하여 많은 대책이 적용되고 있다. 도로청소에 의한 방법 또한 오염물의 강우유출에 의한 배출양을 감소시킬 수 있는 대책 중의 하나로 인식되는 추세에 있다. 본 연구에서는 도로청소 시 수거된 토사입자들의 특성을 파악하고 퇴적토사에 함유된 오염물질의 농도를 분석하였다. 분석결과를 바탕으로 하여 도로 구간별로 도로청소에 의하여 저감할 수 있는 오염물의 양을 평가하였다. 도로청소를 통하여 수거된 퇴적토사는 모래질로 분석되었으며 세립토 비중은 낮은 결과를 보였다. 퇴적토사 내 오염물의 양은 토양환경기준을 초과하지 않았으나 청소작업시 물을 살수함으로써 토사에 포함된 오염물이 세척되어 침출수로 미리 배출되는 것에 기인한다고 판단된다. 두 도로구역에 대하여 오염물 농도, 발생 퇴적토사량, 오염물 원단위를 적용하여 저감할 수 있는 오염물 양을 평가한 결과, ${\bigcirc}{\bigcirc}$지역에 대하여 TSS 31.4% 및 ${\triangle}{\triangle}$지역에서는 TSS 7.7%의 TSS 저감량이 도출되었다. 중금속과 같은 타 오염물의 경우 훨씬 낮은 저감량이 평가되었으나 이는 물의 살수로 인하여 퇴적토사 내 오염물이 침출수로 배출된 것에 기인한다고 판단된다. 보다 정확하게 도로청소에 의하여 저감할 수 있는 오염물의 양을 산정하기 위하여 보다 자세하고 체계적인 연구가 필요하다고 판단된다.

국내 고속도로 휴게소지역 비점오염원 유출특성 분석 (Evaluation of Pollutants Concentrations and Runoff Characteristics in Highway Rest Area)

  • 김정현;강희만;고석오
    • 한국도로학회논문집
    • /
    • 제12권4호
    • /
    • pp.131-137
    • /
    • 2010
  • 최근 비점오염원에 대한 관심이 높아지면서, 환경부 및 유관단체를 중심으로 노면 유출수를 포함한 비점오염원(Non point source)에 대한 현황 조사 및 처리 방법에 대한 관심이 증가하고 있다. 고속도로 휴게소 주차장 노면 유출수는 고속도로 본선 노면 유출수보다 유해물질 오염도가 높을 것으로 예상되어, 본 연구는 이 지역의 노면 유출수 오염도 조사를 통해 유출수 평가 및 노면 유출수 저감시설의 저감효과를 분석하여 휴게소 노면유출수 관리방안을 수립하는 것을 목적으로 하고 있다. 휴게소지점에 대한 강우 유출수 분석 결과 포장지역의 특성인 초기강우현상을 볼 수 있었으며, 강우초기에 입자상물질은 중금속과 결합하여 다량 유출되는 특성을 나타내었다. 휴게소 지점의 강우유출수에 대한 오염물질별 EMC에 대한 95% 확신범위로는 TSS 128.2-273.4mg/L, COD 145.4-310.1mg/L, TN 6.1-11mg/L, TP 1.9-2.9mg/L의 범위로 분석되어 고속도로에서 유출되는 강우유출수와 비슷한 수준으로 유출되는 것으로 분석되었으나, 중금속의 경우 고속도로에 비해 고농도의 중금속이 유출되는 것으로 나타났는데, 이것은 차량 정차시 브레이크 패드나 타이어의 마모등에 의한 것으로 판단된다. 휴게소지점에 대한 면적당 발생되는 부하량 통계분석결과, TSS의 평균 부하량은 $1411.6mg/m^2$로 산정되었으며, COD $709.7mg/m^2$, TN $44.0mg/m^2$, TP $10.4mg/m^2$로 산정되었다. 중금속의 경우 Total Cu $12927.4{\mu}g/m^2$, Total Fe $32074.4{\mu}g/m^2$, Total Pb $40371{\mu}g/m^2$, Total Ni $10679.2{\mu}g/m^2$로 산정되었다.

오염농도 분포 해석을 통한 공동주택의 자연환기성능 향상을 위한 평면계획 (Planning of Apartment Units for Improving Natural Ventilation Performance based on the Analysis of Indoor Pollutant Concentrations)

  • 김지영;이승희;김태연
    • KIEAE Journal
    • /
    • 제5권3호
    • /
    • pp.41-48
    • /
    • 2005
  • Before occupation of an apartment housing, the builders are required to inform the test result of IAQ to the public. However, there is no simplified method to predict IAQ before measurement of pollutant concentration. In this study, a simplified way of predicting IAQ based on the distribution of indoor pollutant concentration is proposed. 7 different cases of air change rate have been simulated through CFD analysis to get the distribution ratio of each pollutant material and then simplified functions were used with CRIAQ1 values derived from CFD simulation to evaluate by comparing the influence of each material in the indoor pollutant concentration. Again, a lot of efforts which can improve the indoor air quality have been performed. Materials used in indoor space are labeled with their pollutant emission level. Installation of ventilation system in residential buildings will be regulated by a building codes sooner or later. But it is important to understand the fact that layout of walls, location or size of openings will influence the indoor air flow and pollutant concentration. And location of emitting material influences to indoor air pollutants distribution. But until now there is few recognition and consideration of these factors. Therefore, in this paper the effects of these factors is proved and some kind of guideline is made for designers after a comparison of typical apartment floor plan and a new type plan with their average pollutant concentration and its distribution of each room. CFD(Computational Fluid Dynamics) program was used to show the indoor air flow and pollutant concentration distribution. For this purpose, a typical $100m^2$ apartment floor plan was chosen as a case study model and several alternatives were reviewed to improve the IAQ performance. The simulation took place in the condition of natural ventilation through windows.

Numerical and wind tunnel simulation of pollutant dispersion in the near wake of buildings

  • Wang, X.;McNamara, K.F.
    • Wind and Structures
    • /
    • 제8권6호
    • /
    • pp.427-442
    • /
    • 2005
  • Numerical and wind tunnel simulations of pollutant dispersion around rectangular obstacles with five aspect ratios have been conducted in order to identify the effects of flow patterns induced by buildings on plume dispersion in the near wake of buildings. An emission from a low source located upwind of obstacles was used in this simulation. The local flow patterns and concentrations around a cubical obstacle were initially investigated using three RANS turbulence models, (the standard $k-{\varepsilon}$, Shear Stress Transport (SST), Reynolds-Stress RSM turbulence model) and also using Large-eddy simulation (LES). The computed concentrations were compared with those measured in the wind tunnel. Among the three turbulence models, the SST model offered the best performance and thus was used in further investigations. The results show, for normal aspect ratios of width to height, that concentrations in the near wake are appreciably affected because of plume capture by the horseshoe vortex and convection by the vertical vortex pairs. These effects are less important for high aspect ratios. Vertical vortex pairs present a strong ability to exchange mass vertically and acts efficiently to reduce ground-level concentrations in the near wake.

서울시 주요 터널내 기체상 오염물질 농도 측정 (Measurements of Gaseous Pollutants in Major Tunnels in Seoul)

  • 김영성;경남호;손재익;문길주;김용표;백남준;김태오
    • 한국대기환경학회지
    • /
    • 제9권4호
    • /
    • pp.320-328
    • /
    • 1993
  • Gaseous pollutants in Namsan Nos. 1, 2, and 3 tunnels and Pukak tunnel were measured along the road by an air-monitoring van from the evening of February 9 to the morning of February 12 in 1993. Average concentrations of pollutants in Namsan tunnels were 9.2-13.5 ppm CO and 0.037-0.047 ppm SO$_{2}$. Average concentrations of SO$_{2}$ in Pukak tunnel was 0.79 ppm, higher than those in Namsan tunnels, due to the traffic of heavy-duty buses and trucks. The pollutant concentrations in Namsan tunnesl could be explained by emission of passenger cars using unleaded gasolin and LPG taxies. Average concentration of NO$_{x}$ in Namsan tunnels was at least 1.1 ppm, estimated from the emission factor of pasenger cars using unleaded gasoline. Pollutant concentrations in Namsan No. 3 tunnel were higher at the exit because of the piston action of air mass in the tunnel provided by the traffic. Fans installed at Namsan and Pukak tunnes could be useful, but their flushing action of ambient air in the tunnel was not clearly observed.d.

  • PDF

ESTIMATION OF LONG-TERM POLLUTANT REMOVAL EFFICIENCIES OF WET RETENTION/DETENTION BASINS USING THE WEANES MODEL

  • Youn, Chi-Hyueon;Pandit, Ashok;Cho, Han-Bum
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2005년도 학술발표회 논문집
    • /
    • pp.215-219
    • /
    • 2005
  • A macro spreadsheet model, WEANES (Wet Pond Annual Efficiency Simulation Model), has been developed to predict the long-term or annual removal efficiencies of wet retention/detention basins. The model uses historical, site-specific, multi-year, rainfall data, usually available from a nearby National Oceanic and Atmospheric Administration (NOAA) climatological station to estimate basin efficiencies which are calculated based on annual mass loads. Other required input parameters are: 1) watershed parameters; drainage area, pervious curve number, directly connected impervious area, and ti me of concentration, 2) pond parameters; control and overflow elevations, pond side slopes, surface areas at control elevation and pond bottom; 3) outlet structure parameters; 4) pollutant event mean concentrations; and 5) pond loss rate which is defined as the net loss due to evaporation, infiltration and water reuse. The model offers default options for parameters such as pollutant event mean concentrations and pond loss rate. The model can serve as a design, planning, and permitting tool for consulting engineers, planners and government regulators.

  • PDF

Effective Local Exhaust Ventilation on Cooking Fumes of Seasoned Meats

  • Lee Byeong Kyu;Ellenbecker Michael J.
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제2권1호
    • /
    • pp.49-56
    • /
    • 1998
  • This study identified the fumes produced from the cooking of the seasoned meats containing various condiments such as garlic, onion, pepper, soy sauce, and sesame oil. Concentrations, at the breathing zone of the cook, of volatile organic compounds (VOCs) and aldehydes included in the cooking fumes of seasoned meats were identified. Many chloro and fluoro-aliphatic hydrocarbons, aromatic hydrocarbons, ketones, and aldehydes, which could be carcinogen suspecting chemicals, were producing from the cooking fumes of the seasoned meats. This study also identified the ventilation efficiencies of the cooking fumes of the six exhaust ventilation systems, which were widely being used in the general apartments, houses, and small-food factories. For a comparison of the ventilation efficiencies of the systems, acetaldehyde was chosen as a marker pollutant and its concentrations at the breathing zone of the cook were identified. The laboratory fume hood showed the best ventilation efficiency of the six ventilation systems studied, and then the lateral hood ventilation and the down draft ventilation followed the laboratory fume hood. Finally, this study identified that both a wall factor nearby pollutant sources and a distance factor between the hood face and pollutant sources should be also considered for an effective local exhaust ventilation system design.

  • PDF