• Title/Summary/Keyword: Pollutant Unit Loading

Search Result 36, Processing Time 0.027 seconds

Urban Nonpoint Source Pollution Assessment Using A Geographical Information System (GIS를 이용한 도심지 Nonpoint Source 오염 물질의 평가연구)

  • ;Stephen J. Ventura;Paul M. Harris;Peter G. Thum;Jeffrey Prey
    • Spatial Information Research
    • /
    • v.1 no.1
    • /
    • pp.39-53
    • /
    • 1993
  • A geographical information systems(GIS) was a useful aid in the assessment of urban nonpoint source pollution and the development of a pollution control strategy. The GIS was used for data integration and display, and to provide data for a nonpoint source model. An empirical nonpoint source loading model driven by land use was used to estimate pollutant loadings of priority pollutant. Pollutant loadings were estimated at fine spatial resolution and aggregated to storm sewer drainage basins(sewershedsl. Eleven sewersheds were generated from digital versions of sewer maps. The pollutant loadings of individual land use polygons, derived as the unit of analysis from street blocks, were aggregated to get total pollutant loading within each sewershed. Based on the model output, a critical sewershed was located. Pollutant loadings at major sewer junctions within the critical sewershed were estimated to develop a mi t igat ion strategy. Two approaches based on the installat ion of wet ponds were investigated -- a regional approach using one large wet pond at the major sewer outfall and a multi-site approach using a number of smaller sites for each major sewer junction. Cost analysis showed that the regional approach would be more cost effective, though it would provide less pollution control.

  • PDF

Loading Characteristics of Non-Point Source Pollutants by Rainfall - Case Study with Sweet Potato Plot - (강우시 비점오염원의 오염부하 특성 - 고구마 재배지를 대상으로 -)

  • Kang, Mee-A;Jo, Soo-Hyun;Choi, Byoung-Woo;Yoon, Young-Sam;Lee, Jae-Kwan
    • The Journal of Engineering Geology
    • /
    • v.19 no.3
    • /
    • pp.365-371
    • /
    • 2009
  • This paper address the characteristics of loading pollutants caused by the unit agricultural area to establish an efficient management method in NPS (non-point source). The relationship between rainfall and runoff shows good coefficient with 0.92, when the event which shows relatively long antecedent dry days is excepted. The impact of runoff volume on the runoff coefficient can be described by the rainfall intensity strongly. The pollutant EMCs (event mean concentrations) in runoff increased by the increase of antecedent dry days due to dry soil conditions. As the similar pattern of pollutant's loads such as TSS, BOD, COD, TN and TP, it is cleared that other pollutants can be removed when TSS is removed. Therefore the system using only runoff coefficients is not sufficient for the prediction of pollutant loads. It is necessary to consider soil conditions such as rainfall, antecedent dry day, antecedent rainfall etc. for the prediction system.

Estimation of Runoff Characteristics of Nonpoint Pollutant Source in Railroad Area (철도지역의 비점오염원 유출특성)

  • Lee, Chun Sik;Seo, Gyu Tae;Yoon, Cho Hee;Kwon, Heon Gak;Lee, Jae Woon;Cheon, Se Uk
    • Journal of Environmental Science International
    • /
    • v.23 no.3
    • /
    • pp.511-520
    • /
    • 2014
  • The MFFn(Mass first flush), EMCs(Event mean concentrations) and runoff loads were analyzed for various rainy events(monitoring data from 2011 to 2012) in transportation area(rail road in station). The pollutant EMCs by volume of stormwater runoff showed the BOD5 9.6 mg/L, COD 29.9 mg/L, SS 16.7 mg/L, T-N 3.271 mg/L, T-P 0.269 mg/L in the transportation areas(Railroad in station). The average pollutant loading by unit area of stormwater runoff showed the BOD5 $27.26kg/km^2$, COD $92.55kg/km^2$, SS $50.35kg/km^2$, T-N $10.13kg/km^2$ and T-P $10.13kg/km^2$ in the transportation areas. Estimated NCL-curve(Normalized cumulated-curve) was evaluated by comparison with observed MFFn. MFFn was estimated by varying n-value from 10% to 90% on the rainy events. The n-value increases, MFFn is closed to '1'. As time passed, the rainfall runoff was getting similar to ratio of pollutants accumulation. The result of a measure of the strength of the linear relationship between observed data and expected data under model was good.

Determination of Heavy Metal Unit Load from Transportation Landuses during a Storm (교통 관련 토지이용에서의 중금속 오염원단위 산정)

  • Kim, Cheol-Min;Lee, So-Young;Lee, Eun-Ju;Kim, Lee-Hyung
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.6
    • /
    • pp.155-160
    • /
    • 2008
  • The urban areas have various landuses such as residential, commercial, industrial and official purposes that are highly concerned with human activities. The other landuses are relating to vehicle activities, which are roads, parking lots, bridges, parks etc. The mainly using landuses by human activities are possessing three different areas that are buildings, parking lots/roads and landscapes. Of these areas, the buildings and landscapes can be classified as non-pollution areas. However, the parking lots or roads are classifying as the main pollution areas because of vehicle activities. Therefore, the landuses arising the nonpoint pollution during a storm in urban areas are roads and parking lots. The vehicles are emitting lots of nonpoint pollutants such as metals and particulate matters and it is impacting on water qualities and aqua-ecosystems nearby the city areas. Therefore, this research was conducted for characterizing the pollutant types and determining the EMCs (Event Mean Concentrations) and unit pollutant loads during a storm. The monitoring was performed on 9 locations such as highways, service area, tollgates, parking lot and bridges. All of the landuses selected for monitoring are concerned with transportation. The results can be effectively used to predict the pollutant loading before urban planning and to select the BMPs (Best Management Practices) for reducing the pollution.

Pollutants Unit Loadings of the Stormwater Runoff in Industrial Complex (강우시 산업단지에서의 유출오염부하량 원단위 산정)

  • Lee, Jun-Ho;Bang, Ki-Woong;Choi, Jong-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.355-362
    • /
    • 2000
  • The objective of this paper is to estimate the pollutant load based on event mear concentrations(EMC) in industrial complex. Eight sub-basins in the Chongju industrial complex were selected for sampling and study with different characteristics during the period from June 1997 to August 1998. During the storm events, measured EMC ranges of $BOD_5$, COD, SS, TKN, TP, HEM, $NO_3-N$, $PO_4-P$, Cr, Pb, Cu and Fe in the industrial complex watersheds were 11~176mg/L, 40~502mg/L, 23~633mg/L, 104~20.9mg/L, 0.22~7.51mg/L, 12.7~548.7mg/L, 0.06~2.66mg/L, 0.12~3.39mg/L, 0.01~0.50mg/L. 0.02~0.42mg/L, 0.01~0.15mg/L and 1.29~11.51mg/L respectively. And the calculated annual average pollutant unit loadings of $BOD_5$ COD, SS, TKN, $NO_3-N$, $PO_4-P$, TP, HEM, Cr, Pb, Cu and Fe were 374.4kg/ha/yr 924.1kg/ha/yr, 983.6kg/ha/yr, 48.8kg/ha/yr, 8.1kg/ha/yr, 9.7kg/ha/yr, 17.8kg/ha/yr 943.0kg/ha/yr, 0.7kg/ha/yr, 0.9kg/ha/yr, 0.3kg/ha/yr and 28.9kg/ha/yr, respectively.

  • PDF

Estimating Unit Load of Non-Point Source Pollutants for Landuse Types in Anseongchun Watershed (안성천 유역의 토지이용별 비점오염원 원단위 산정)

  • Hwang, Byung-Gi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.5
    • /
    • pp.1026-1033
    • /
    • 2009
  • In this study, we computed the unit load of nonpoint source for the forest, agricultural, and urban representative region in Anseongchun watershed. In addition, Flow-weighted mean concentration (FWMC) that well represents runoff characteristics of storm water during rainfall, was calculated, and runoff pollutants loading was also examined. FWMCs of 1st rainfall, which runoff coefficient was high, had a tendency higher than those of 2nd rainfall. Based on landuse results, pollutant concentration of the non-urban such as forest and agricultural regions was higher than that of urban region. In case of BOD, runoff pollutants loading was calculated as 1,395, 1,623, 2,268kg/d in 1st rainfall for forest, agricultural, and urban regions, respectively, while runoff loading of 2nd rainfall was 503kg/d in forest), 512kg/d in agricultural, and 898kg/d in urban. By landuses, unit load of the urban as 72.7kg/ha/yr was 12 times higher than that of the agricultural as 6.5kg/ha/yr, and 8 times higher than that of the forest as 9.5kg/ha/yr.

Analysis of the Phosphorus Contribution Rate by the Environment Fundamental Facilities Located in Upstream Basin of Paldang Lake (팔당호 상류수계에 위치한 환경기초시설의 인 기여도 분석)

  • Woo, Younggug;Park, Eunyoung;Jeon, Yangkun;Yang, Heejeong;Rim, Jaymyung
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.6
    • /
    • pp.1016-1027
    • /
    • 2010
  • The phosphorus contribution rate on water quality of North and South-Han River, and Gyungan-cheon by effluents from environmental fundamental facilities located in upstream basin of Paldang Lake were analyzed. QUALKO2 model was selected for the analysis of contrubution rate, and was constructed considering the location of the main point sources and all facilities in study area. The pollutant loading rates and arrival rates for each unit-watershed in study area were calculated for model operation. For the calibration and verification of model, 2006 water quality dataset from Ministry of Environment and the effluent loadings of the environmental fundamental facilities were used. Reliability Index (RI) method was used to estimate the validity of the results of calibration and verification. The phosphorous contribution rate(%) for each environmental fundamental facility were analyzed by excepting the effluent loading of the facility. The contribution rate was analyzed for each facility, facility groups separated by each main river and each unit-watershed. The main results of analysis for each facility are as follows; (i) the phosphorous contribution of B1 facility is 50%, which is the highest phosphorous contribution rate among those of nine facilities in the North-Han River Basin; (ii) the highest phosphorous contribution is 55.6% from J facility among eight facilities in the Gyungan Stream Basin; (iii) 40% from E treatment facility is the highest among those of twenty eight facilities in the South-Han River Basin.

Evaluation of Basic Unit for Non-point Pollutants in Runoff of West Coast Highway - Maesong Area (서해안 고속도로 매송지역 비점오염원 원단위 산정 연구)

  • Park, Seyong;Mo, Kyung;Kim, Leehyung;Kang, Heeman;Kim, Moonil
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.8
    • /
    • pp.33-40
    • /
    • 2010
  • In this study, evaluation of basic unit of non-point pollutant, which is fundamental evaluation of non-point loading, was conducted using both road point and angle of intersection point in Maesong area, West coast highway by utilizing Event Mean Concentrations(EMC). Concentration of pollutants except heavy metals at these two points rapidly decreased in 30 minutes after start of runoff. According to the results of EMC, for both sampling points, it was determined that the concentrations of TSS(Total Suspended Solid), $BOD_5$(Biological Oxygen Demand), and DOC(Dissolved Organic Carbon) were higher than those of wastewater effluent standard in Korea, however, the concentrations of T-N(Total Nitrogen) and T-P(Total Phosphorus) were lower than those of the standard. In terms of heavy metals, Fe, Pb, and Zn showed higher concentrations than others. When compared with the units established by the Ministry of Environment in Korea, the basic units of $BOD_5$ and T-N in this study were lower. On the other hand, when compared with foreign units, Cu, Pb, and Zn showed approximately 10 times higher concentrations. It was estimated that a long term monitoring should be conducted for obtaining additional data and more reliable basic units for the non-point pollutnats based on the results from this study.

Solid Separation and Flotation Characteristics of Livestock Wastewater Using DAF Process (DAF 공정을 이용한 축산폐수의 고형물 분리와 부상특성)

  • Kang, Byong-Jun;Yoo, Seung-Joon;Lee, Se-il;Kwak, Dong-Heui
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.3
    • /
    • pp.359-366
    • /
    • 2008
  • The series of experiments under the various conditions were carried out to evaluate the feasibility of dissolved air flotation (DAF) as an alternative of conventional gravity sedimentation (CGS) and to investigate the decrease of the loadings following to biological wastewater treatment processes in livestock wastewater system. On the basis of the experiment result between CGS and DAF processes, for the other water quality criteria as well as suspended solid the removal efficiency of DAF process was about 20~25 % better than CGS process on average. In addition, the particle removal efficiency of DAF process became higher in proportion as the increase of air to solid (A/S) ratio and the general wastewater treatment efficiency of DAF process was enough to meet the requirement of loading decrease to following biological process even at low A/S ratio range. Though DAF process is widely known as an solid separation unit, there was not the notable relationship between particle separation efficiency and several pollutant removal efficiencies like $COD_{Cr}$ and nutrients (T-N, T-P). Assume that the $COD_{Cr}$ was removed as the fraction of particle separation in this experiment, the removal efficiency of T-N and T-P were sensitive to removal efficiency of $COD_{Cr}$, especially.

Loading Characteristics of Non-Point Source Pollutants by Rainfall - Case Study with Cherry Tree Plot - (강우시 비점오염원의 오염부하 특성 - 벚나무 재배지를 대상으로 -)

  • Kang, Mee-A;Choi, Byoung-Woo;Yu, Jae-Jeong
    • The Journal of Engineering Geology
    • /
    • v.20 no.4
    • /
    • pp.401-407
    • /
    • 2010
  • This study was carried out to produce the characteristics of pollutant loads caused by a cherry tree plot as a nonpoint sources(NPS) unit in agricultural areas. The relationship between rainfall and runoff didn't show a good coefficient with 0.5. Despite precipitation amount was less than 20 mm, runoff occurred with $0.5\;m^3$ because of high rainfall intensity of 8.8 mm/hr. In contrast, runoff was not occurred when precipitation amount was 47.4 mm in one case. In that case the primal effect on runoff was not precipitation amount. Correlation between load of pollutants such as BOD, COD, TN and TP and runoff' volumes showed significantly positive values which were more than r = 0.92 for all pollutants except SS(r = 0.71). SS could be a proper factor for estimating pollutant loads of BOD, COD, TN and TP because of a high correlation more than r = 0.73 between SS load and pollutant loads of BOD, COD, TN and TP. Both Organics and nutrient pollutants could be reduced if we control SS in runoff. The highest concentration of TN was detected in the event which was affected by fertilization activities directly. Therefore fertilization must be considered as a function of impact parameters on TN load in agricultural areas.