남강댐 유역의 유출량과 오염부하량 연구 (A Study on Outflow and Pollutant Loading in Nam River Dam Basins)

  • 김종오;김옥선;김홍철
    • 한국습지학회지
    • /
    • 제2권1호
    • /
    • pp.87-94
    • /
    • 2000
  • The purpose of this study was to analysis the pollutant loading of Chin yang Reservoir according to the variation of outflow. Regression equation of the pollutant loading and outflow was represented as $L=a\;Q^b$ in which L = pollutant loading(kg/day), a and b = regression coefficient, and Q = outflow($m^3/day$). Regression coefficients ($R^2$) of Sanchung, Sinan and Changchon site was in range of 0.8376 to 0.9818. Therefore the pollutant loading was good correlated with outflow. Changchon site had minimum b value because outflow of pollutant was little compared with rainfall. The SS was the highest b value 1.621~1.7834 among water quality parameters because the pollutant loading of SS was much affected by outflow. Also, the pollutant loadings per area could be calculated and compared in case of the dry season, normal season and flood season. The pollutant loading in the normal and flood season except the dry season were higher in order of Sanchung, Sinan and Changchon site. Pollutant loading per area were higher in order of Sinan, Sanchung and Changchon site. When it compared with pollutant loading per area calculated using pollutant unit loading, T-N was much different each other.

  • PDF

수질 모니터링과 원단위법을 이용한 농업소유역의 오염부하량 추정 (Estimation of Pollutant Loadings from Agricultural Small Watershed Using the Unit Loading Factor and Water Quality Monitoring)

  • 김상민;강문성;박승우
    • 한국농공학회지
    • /
    • 제45권3호
    • /
    • pp.94-102
    • /
    • 2003
  • A hydrologic and water quality monitoring network were established in the Balkan-reservoir watershed, which has 29.79 $km^2$ in size, to analyze the characteristics of pollutant loading from an agricultural small watershed. Soil type, land use, hydrologic soil group, population and livestock were also surveyed to make clear the pollutant sources and to calculate the pollutant loadings by the unit loading factor method which was proposed by the Ministry of Environment. From the 5-year hydrologic monitoring results, sub-watersheds located in the upstream of the reservoirs showed higher average runoff ratio. The calculated daily pollutant loadings by the unit loading factor method from HP#2 sub-watershed in the downstream of Balkan reservoir, were much greater than observed.

Quantitative Assessment of Nonpoint Source Load in Nakdong River Basin

  • Kwon, Heon-Gak;Lee, Jae-Woon;Yi, Youn-Jeong;Cheon, Se-Uk
    • 한국환경과학회지
    • /
    • 제23권1호
    • /
    • pp.7-23
    • /
    • 2014
  • This study estimates unit for the nonpoint source(NPS), classified according to the existing Level-1(large scale) land cover map, by monitoring the measurement results from each Level-2(medium scale) land cover map, and verifies the applicability by comparison with previously calculated units using the Level-1 land cover map. The NPS pollutant loading for a basin is evaluated by applying the NPS pollutant unit to Dongcheon basin using the Level-2 land cover map. In addition, the BASINS/HSPF(Better Assessment Science Integrating point & Non-point Sources/Hydrological Simulation Program-Fortran) model is used to evaluate the reliability of the NPS pollutant loading computation by comparing the loading during precipitation in the Dongcheon basin. The NPS pollutant unit for the Level-2 land cover map is computed based on precipitation measured by the Sangju observatory in the Nakdong River basin. Finally, the feasibility of the NPS pollutant loading computation using a BASINS/HSPF model is evaluated by comparing and analyzing the NPS pollutant loading when estimated unit using the Level-2 land cover map and simulated using the BASINS/HSPF models.

Characteristics of Pollutant Loading in Namdae-cheon Watershed

  • Choi, Jin-Kyu;Son, Jae-Gwon
    • 한국농공학회지
    • /
    • 제45권7호
    • /
    • pp.49-56
    • /
    • 2003
  • Nonpoint source pollutant loading from watershed may cause a problem to the water quality of the reservoir and stream. The characteristics of stream flow and water quality were monitored to investigate the runoff loading of the Namdae-cheon watershed from May in 1999 to October in 2003. Stage-discharge rating curve at the stream gauging site was established, and annual stream runoff of the study watershed was estimated as 499.4∼1,330.8mm during four years. The concentrations of total-nitrogen and total-phosphorus of stream water quality ranged from 0.76 to 6.95mg/L and from 0.0010 to 0.2276 mg/L, respectively, where T-N was generally higher than the water quality standard 1.0 mg/L for agricultural water use. The loads by unit generation of pollutant mass with respect to population, livestock, land use in this watershed were calculated. The runoff pollutant loadings by concentrations of total-N and total-P were estimated during study period, where the annual runoff loading of total-P was much less than the load by pollutant mass unit generation. The relations between stream discharge and water quality were analysed, and there was a high correlation for total-N but low for total-P. These results will be used to develop the monitoring techniques and water quality management system of agricultural watershed.

영산강 수계의 비점오염원에 관한 연구 I - 토지이용 및 강우를 중심으로 - (Non-Point Source Pollutions of the Youngsan River Basins I - The Method of Land-Use Types and Rainfall -)

  • 차진명;신성의;차규석
    • 환경영향평가
    • /
    • 제8권1호
    • /
    • pp.41-49
    • /
    • 1999
  • This study was carried out to estimate the runoff loading characteristics of the non-point source pollutions in the Youngsan river basins by the method of land-use types and rainfall. The lysimeter test, rainfall and stream flowmeter measurement were performed to develop the pollutant loading unit discharged from the non-point sources. As the non-point sources, the unit pollutant discharge rates were different from the land-use types such as paddy field, upland, forest, housing site and others. The pollutant loading units classified by land-use types in the Youngsan river basins are as follows: The total BOD loading rate is 15.3 ton/day and the housing site is discharged 50.6%, the total T-N loading rate is 6.0 ton/day and the paddy field and upland is discharged 77.6%, and the total T-P loading rate is 0.39 ton/day and the paddy field and upland is discharged 81.2%. The pollutant loadings by rainfall in the Youngsan river basins are about 7,425 ton/year of BOD, 324 ton/year of T-N and 118 ton/year of T-P, respectively.

  • PDF

담수호 유입 오염부하량의 간척농지 영농 전.후 변화 예측 (Prediction of the Pollutant Loading into Estuary Lake according to Non-cultivation and Cultivation conditions of Reclaimed Tidal Land)

  • 윤광식;최수명;양홍모;한국헌;한경수
    • 농촌계획
    • /
    • 제7권1호
    • /
    • pp.27-36
    • /
    • 2001
  • Estimation of current and future loading from watershed is necessary for the sound management of water quality of an estuary lake. Pollution sources of point and non-point source pollution were surveyed and Identified for the Koheung watershed. Unit factor method was used to estimate potential pollutant load from the watershed of current conditions. Flow rate and water qualify of base flow and storm-runoff were monitored in the main streams of the watershed. Estimation of runoff pollutant loading from the watershed into the lake in current conditions was conducted by GWLF model after calibration using observed data. Prospective pollutant loading from the reclaimed paddy fields under cultivation conditions was estimated using the modified CREAMS model. As a result, changes of pollutant loading into estuary lake according to non-cultivation and cultivation conditions of reclaimed tidal land were estimated.

  • PDF

駕莫灣 流域의 汚染負荷 特性에 관한 硏究 (A Study on the Characteristics of Pollutant Loads in Kamak Bay Watershed)

  • 이대인;조현서
    • 한국환경과학회지
    • /
    • 제11권9호
    • /
    • pp.945-954
    • /
    • 2002
  • The objective okgf this study is understanding and evaluation of temporal and spatial variation of pollutant loads by input sources for water quality management in Kamak Bay. Flow rate of rivers and ditches ranges from about $2,592-63,072m^3/d$ in October to $864-55,296m^3/d$ in January. In particular, the R2 predominated flow rate among input sources. Total COD, BOD, DIN and DIP loadings in January were about 896kg/d, 718kg/d, 2,152kg/d, and 154kg/d, respectively, which exceeded those of October. Lower POC/TOC levels are estimated in R2, and also in October. Temporal variation of pollutant loads were closely related to the human activity. Total discharging loadings of BOD, TN and TP by unit loading estimation were 4,993.0kg/d, 2,558.7kg/d, and 289.2kg/d, respectively, and were mainly affected by the population. Runoff ratio of BOD was about 0.14 in January Mean $NH_4^+_-N$ and $PO_4\;^{3-}-P$ loadings from sediment were 16.23mg/$m^2$/d and 7.26mg/$m^2$/d, respectively. For the improvement of water quality in this area, not only pollutant loads of rivers and ditches but also benthic flux from sediment should be reduced within the limits of the environmental capacity.

Characteristics of Pollutant Loads and Water Quality in Kwangyang Bay, Korea

  • Lee Dae-In;Park Chung-Kil;Cho Hyeon-Seo
    • Fisheries and Aquatic Sciences
    • /
    • 제6권3호
    • /
    • pp.149-154
    • /
    • 2003
  • The characteristics of pollutant loads from the various sources and seawater quality in Kwangyang Bay were evaluated. Total flow rate was estimated to be $10,868,066.8 m^3/day$ with a flow rate of R2l (the Seomjin River) as the highest one. Total COD, TN and TP loads of the input rivers and the ditches were about 27,591.8, 25,029.6 and 586.4 kg/day, respectively. Wastewater discharging loads was the greatest contributors to pollutant loads in the inner part of Kwangyang Bay. COD values in the inner part of the bay was over 3.0 mg/L, which exceeded the seawater quality criteria III of Korea. The average values of DIN and DIP were 8.62 ${\mu}gN/L\;and\;1.26\;{\mu}gP/L$, respectively. The limiting factor for algal growth was DIN. In he total discharging loads of the watershed from unit loading estimations, BOD, TN and TP were 9,132.3, 2,727.2 and 304.2 kg/day, respectively. In addition, municipal sewage by the population as pollution sources and the city of Kwangyang as administrative district had the highest loads. For a appropriate water quality recovery of Kwangyang Bay, it is suggested that it is essential to estimate reduction rate of total pollutant loads by water quality modeling.

영산호의 부영양화방지를 위한 질소, 인의 배출원단위에 관한 조사연구 (Unit Loading Factor of Nitrogen and Phosphorus for Controlling Eutrophication of Youngsan Lake)

  • 류일광;이치영;강영식;김관천
    • 한국환경보건학회지
    • /
    • 제15권2호
    • /
    • pp.51-58
    • /
    • 1989
  • In order to estimate unit loading factors of N, and P for controlling eutrophication of Youngsan lake. This study was performed in 4 kinds of pollutant sources from domestic sewage, industrial waste water, livestock stall waste water and drainage of agricultural area during the period from april to october 1988. These results were as follows: 1. The sewage flow for domestic waste water was 191.2 l/capita, day and that of the gray and toilet waste water among the domestic waste water were shown 152.9 l/capita, day(80%) and 38.3 l/capita, day(20%), respectively. 2. The unit loading factor total nitrogen(T-N) for domestic waste water was 7.582g/capita, day, and that of the gray and toilet waste water among the domestic waste water were 1.826g/ capita, day(24.1%) and 5.756g/capita, day(75.9%), respectively. The other hand, the unit loading factors of total phosphorus(T-P) for domestic waste water was 0.925g/capita, day, and that of gray and toilet waste water among the domestic waste water were 0.470g/capita, day(50.8%) and 0.455g/capita, day(49.2%), respectively. 3. In offering Price per million won, the T-P loading factor for drinking manufacture, confectionery manufacture, beer-manufacture and fibre manufacture in the industrial pollutant sources estimate to be 0.350g/day, 0.099g/day, 32.351g/day and 1.536g/day, while T-N loading factor about them in the industrial pollutant sources estimate to be 4.117g/day, 2.414g/day, 106.726g/day and 60.504g/day, respectively. 4. The T-P loading factor according to wash-water of milch cow and pig were 6.735g/day and 18.526g/day, in case of T-N they were 42.397g/day and 27.226g/day, respectively. 5. The T-P loading factor for pollutants drainage in the Paddy fields, fields and forests area were 0.082g/are, day, 0.014g/are, day and 0.002g/are, day, and the T-N loading factor were 0.309g/are, day, 0.158g/are, day and 0.064g/are, day, respectively. The diffrent of the loading factor for pollutants discharges in the agricultural area were resulted from the rainful intensity, the rainful, the amount of fertilization manure, and etc.

  • PDF

금강수계 남대천유역의 수질변화와 오염부하량 (Pollutant Loading and Changes of Water Quality at the Namdae-cheon Watershed in Keum river Districts)

  • 최창현;한강완;조재영;전재철;김성조
    • 한국환경농학회지
    • /
    • 제19권1호
    • /
    • pp.26-31
    • /
    • 2000
  • 금강수계 상류에 위치하고 있는 전라북도 무주군 남대천 유역을 대상으로 1995년 7월부터 1998년 4월까지 32개월 동안 4개 지점의 수질시료에 대한 질적변화를 주기적으 로 조사하였다. 또한 남대천 유역의 인구, 가축 그리고 토지이용에 따른 원단위 오염부 하량과 실측 오염부하량을 비교 분석하였다. 수계 환경에 영향을 미칠 수 있는 영양물질을 대상으로 시기별 함량 변화를 조사한 결과, 전질소는 $1.8{\sim}5.8\;mg/L$의 범위로 평균 3.8 mg/L, 전인산은 $0.01{\sim}0.08\;mg/L$의 범위로 평균 0.05 mg/L를 나타내었다. 남대천 유역의 원단위 오염부하량은 질소 550.4 ton/yr, 인산 79.1 ton/yr로 나타났는데, 질소원의 경우 가축사육에 의한 부하량이 358.1 ton/yr로 전체의 65.1 %를, 토지이용에 의한 부하량이 129.3 ton/yr로 전체의 23.5 %를, 인구에 의한 부하량이 63.0 ton/yr로 전체의 11.4 %를 차지하는 것으로 조사되었다. 인산원의 오염부하량은 가축 사육에 의한 오염부하량이 60.6 ton/yr로 전체의 76.6 %를, 인구에 의한 부하량이 13.3 ton/yr 로 전체의 16.8 %를, 토지이용에 의한 부하량이 5.2 ton/yr로 전체의 6.6 %를 차지하였다. 각 조사지점별 질소와 인산의 실측 오염부하량은 질소 452.5 ton/yr, 인산 5.4 ton/yr로 나타 났는데 원단위 오염부하량과 비교시 인산의 경우 상당한 차이를 나타내고 있었다.