• 제목/요약/키워드: Polishing machine

검색결과 219건 처리시간 0.025초

Influence of toothbrush abrasion and surface treatments on the color and translucency of resin infiltrated hybrid ceramics

  • Labban, Nawaf;Al Amri, Mohammad;Alhijji, Saleh;Alnafaiy, Sarah;Alfouzan, Afnan;Iskandar, Mounir;Feitosa, Sabrina
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권1호
    • /
    • pp.1-11
    • /
    • 2021
  • PURPOSE. The study compared the color change, lightness, and translucency of hybrid resin ceramics exposed to toothbrush abrasion and surface treatment. MATERIALS AND METHODS. Four hybrid ceramics [Lava Ultimate (LU), Vita Enamic (EN), Shofu HC (SH), and Crystal Ultra (CU)] were compared with a glass-ceramic (Vita Mark II) control. One hundred and twenty specimen blocks were prepared using a precision saw machine. Specimens in each material were divided into four subgroups based on the surface treatment (polishing or staining) and a storage medium (water or citric acid). Simulated tooth brushing with a mixture of 100 RDA (radioactive abrasives) with 0.3 ml distilled water was used for 3650 cycles (7300 strokes) for each specimen. Measurements for the color change, lightness, and translucency were measured after toothbrushing using a spectrophotometer. Statistical analysis compared outcomes using paired t-test, ANOVA, and Tukey post hoc test. RESULTS. The maximum color change was identified in SH (stained acid) [1.44 (0.40)], whereas the lowest was identified in EN (polished water) [0.66 (0.16)] material. The maximum and minimum loss of surface translucency was observed in SH (polished water) [12.3 (0.52)] and EN (stained acid) [6.5 (0.55)] specimens, respectively. Lastly, loss of lightness was the highest in VM (polished acid) [69 (0.95)], whereas the lowest was observed in CU (stained water) [56.7 (0.86)]. CONCLUSION. The comparison presented a significant effect of toothbrush abrasion on translucency and lightness of the hybrid resin ceramics. Color change was not significantly influenced irrespective of the storage medium employed. Surface staining demonstrated the preservation and stability of color and optical properties under the influence of toothbrush abrasion and chemical trauma.

대구지방 산업장에 있어서 건강장애요인과 작업환경검사에 대한 기업인의 수용태도 (ll) (Status of Industrial Environments of Some Industries in Taegu Kyungpook Area)

  • 김두희;성수원
    • 월간산업보건
    • /
    • 통권8호
    • /
    • pp.4-30
    • /
    • 1988
  • Examination of working environments was conducted to get more detailed data about harmful working environments and to make a contribution to more effective management. Study was carried out on 722 factories located in Taegu city and eight counties in Kyungpook Province, Korea, for a period of one year, from February 1 to December 30, 1986. The total number and proportion of workers exposed to harmful material was 37,697, 45.2% among 83,368 workers. The results according to exposed material were as follows: 1. In the case of noise, proportion of exceeding the 8-hour TLV was 59%, Included were nail-cutting in assembly metal manufacturing industry and weaving process in textile. 2. Dust in mill process of coal manufacturing industries exceeded the TLV of second class of dust at all parts and exceeded the TLV at 6% as a whole.: 3. The fields of industry lower than 70 lux of illumination were storage equipment of food, auto-winder of textile, painting of wood wares and coal mixing, and 44% of all cases was lower than standard. 4. As a result of temperature index investigation(WBGT), about 12% of all sujects exceeded limit value. Included parts were rolling machine and reducing room. 5. In the case of organic solvents, TLV was exceeded at about 8%, The parts exceeded TLV according to materials belonged to this category were as follows. 1) Toluene: adhesive work in assembly metal manufacturing 2) Xylene: printing and paint mixing in chemical manufacturing 3) Methyl ethytl ketone: paint mixing in all parts examined and coating machine partially in chemical manufacturing 4) Methyl isobutyl ketone: printing in chemical manufacturing 5) Acetone: vapor polishing in assembly metal manufacturing 6. Among specified chemical materials, the concentration of HC1 in the air in metal assembly manufacturing factory exceeded TLV. in one of three assembly metal manufacturing examined. Others, such as benzene, acetic acid, formic acid, sodium hydroxide, formalin, ammonia, copper, chromate etc. were lower than TLV in its indoor atmospheric concentration. As a whole, the proportion of exceeding TLV was about 0.8% 7. The concentrations of inorganic lead were lower than TLV in all parts examined. The results of this investigation show the fact that current management of working environments is not satisfactory, and so more active management is needed.

  • PDF

THE EFFECTS OF SURFACE CONTAMINATION ON THE SHEAR BOND STRENGTH OF COMPOMER

  • Heo, Jeong-Moo;Lee, Su-Jong;Im, Mi-Kyung
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.577-577
    • /
    • 2001
  • The lastest concepts in bonding are "total etch", in which both enamel and dentin are etched with an acid to remove the smear layers, and "wet dentin" in which the dentin is not blown dry but left moist before application of the bonding primer. Ideally, the application of a bonding agent to tooth structure should be insensitive to minor contamination from oral fluids. Clinically contaminations such as saliva, gingival fluid, blood and handpiece lubricant are often encountered by dentists during preparation of a restoration. The aim of this study was to evaluate the effect of contamination by hem-ostatic agents on shear bond strength of compomer restorations. One hundred and ten extracted human maxillary and mandibular molar teeth were collected. The teeth were cleaned from soft tissue remnant and debris and stored in physiologic solution until they were used. Small flat area on dentin of the buccal surface were wet ground serially with 400, 800 and 1200 abrasive paper on automatic polishing machine. The teeth were randomly divided into 11 groups. Each group was conditioned as follows: Group 1 : Dentin surface was not etched and not contaminated by hemostatic agents. Group2 : Dentin surface was not etched but was contaminated by Astringedent (Ultradent product Inc., Utah, U.S.A.). Group3 : Dentin surface was not etched but was contaminated by Bosmin (Jeil Phann, Korea.). Group4 : Dentin surface was not etched but was contaminated by Epri-dent (Epr Industries, NJ, U.S.A.). Group5: Dentin surface was etched and not contaminated by hemostatic agents. Group 6 : Dentin surface was etched and contaminated by Astringedent. Group7 : Dentin surface was etched and contaminated by Bosmin. Group8 : Dentin surface was etched and contaminated by Epri-dent. Group9 : Dentin surface was contaminated by Astringedent. The contaminated surface was rinsed by water and dried by compressed air. Group10 : Dentin surface was contaminated by Bosmin. The contaminated surface was rinsed by water aud dried by compresfed air. Group 11 : Dentin surface was contaminated by Epri-dent. The contaminated surface was rinsed by water and dried by compresfed air. After surface conditioning, F2000 was applicated on the conditoned dentin surface. The teeth were thermocycled in distilled water at $5^{\circ}C\;and\;55^{\circ}C$ for 1000 cycles. The samples were placed on the binder with the bonded compomer-dentin interface parallel to the lmife-edge shearing rod of the Universal testing machine(Zwick 020, Germany) running at a cross head speed of 1.0mmimin. There were no significant differences in shear bond strength between groups 1 and group 3 and 4, but group 2 showed significant decrease in shear bond strength compared with group 1. There were no significant differences in shear bond strength between group 5 and group 7 and 8, but group 6 showed significant decrease in shear bond strength compared with group 5. There were no significant differences in shear bond strength between group 5 and group 9, 10 and 11.

  • PDF

상이질 접착제의 적용방법에 따른 전단결합강도와 접착양상에 관한 연구 (INFLUENCE OF APPLICATION METHODS OF A DENTIN ADHESIVE ON SHEAR BOND STRENGTH AND ADHESIVE PATTERN)

  • 박성택;문주훈;조영곤;온영석
    • Restorative Dentistry and Endodontics
    • /
    • 제24권2호
    • /
    • pp.381-391
    • /
    • 1999
  • A new 5th generation adhesive system(ONE-STEP) has been supplied which operators can apply to conditioned tooth surfaces by one simplified step. The purpose of this study was to determine whether different methods of adhesive application and various air drying duration after applying adhesive affect the shear bond strength of composite resin to dentin, and to evaluate the adhesive pattern of composite resin and dentin under SEM. Seventy-seven extracted human molar teeth were cleaned and mounted in palstic test tubes. The occlusal dentin surfaces were exposed with Diamond Wheel Saw and smoothed with Lapping and Polishing Machine (South Bay Technology Co., U.S.A.). Teeth were randomly divided into 7 groups (n=11), In experimental A group, adhesive was applied to dentin with agitation for 20 sec. In experimental N-A group, adhesive were continuously applied to dentin for 20 sec. Also control and experimental 1, 2, 3, 4 groups were dried for 10, 0, 5, 20, 30 seconds after applying adhesive, respectively, Adhesives were light cured for 10 sec. A gelatin capsule 5mm in diameter was filled with Aelitefil$^{TM}$ composite resin, placed on the treated dentin surface and light cured for 40 see, from three sides, All specimens were stored in distilled water at room temperature for 24 hours. The shear bond strengths were measured using a universal testing machine(AGS-1000 4D, Japan) at a crosshead speed of 5mm/min. An one-way ANOVA and LSD test were used for statistical analysis of the data. For SEM evaluation, seven specimens were made and sectioned. Representive postfracture and seven specimens were mounted on brass stubs, sputter-coated with gold and observed under SEM. The results were as follows : 1. The shear bond strength of experimental A group which adhesive were applied to dentin with agitation was higher than that of experimental N-A group (continuous application), and there was significant difference between two groups (p<0.01). 2. The interface between composite and dentin according to different application methods showed close adaptation in experimental A group and showed tinny gap in experimental N-A group. 3. The shear bond strength accoding to various air drying duration was the lowest value(7.57${\pm}$2.60 MPa) in experimental 1 group, so there was significant difference between experimental 1 group and other four groups (p<0.05). But there was no significant difference of shear bond strength between four groups (p>0.05). 4. The interface between composite and dentin according to various air drying duration showed close adaptation in control group and tinny gap in experimental 3 and 4 groups. But experimental 1 and 2 groups showed $30{\mu}$ and 6 - $10{\mu}m$ thick gaps, respectively.

  • PDF

이산화티타늄 나노입자를 함유한 3D 프린팅 의치상 레진의 항진균성 및 굽힘 강도에 대한 연구 (A study of the antifungal properties and flexural strength of 3D printed denture base resin containing titanium dioxide nanoparticles)

  • 윤석원;조영은
    • 대한치과보철학회지
    • /
    • 제62권2호
    • /
    • pp.95-103
    • /
    • 2024
  • 목적: 디지털 기술이 발전함에 따라 3D 프린팅 기술이 의치상 제작에 활용되고 있으나 적층 제조의 특성상 의치상 표면에 미생물 부착이 증가한다는 단점이 있다. 본 연구는 3D 프린팅 의치상 레진의 항진균성을 개선하기 위하여, 이산화티타늄 나노입자를 각기 다른 중량비로 첨가하였을 때 균사 형태의 Candida albicans에 대한 의치상 레진의 항진균성과 그에 따른 굽힘 강도의 변화에 대해 알아보고자 하였다. 재료 및 방법: 항진균성을 평가하기 위해 3D 프린팅 레진에 이산화티타늄 나노입자를 0.5, 1, 1.5, 2 wt%의 중량비로 혼합하고, 이산화티타늄 나노입자를 포함하지 않은 대조군을 포함해 5개 군을 직경 20 mm 높이 3 mm의 원기둥 형태의 형태로 각각 20개씩 출력하였다. Autogrinder를 이용하여 10개는 연마를 시행하였고, 나머지 10개는 연마를 시행하지 않았다. 각 시편에 균사 형태의 C.albicans를 접종하고, 흡광도와 집락수를 분석하였고, 시편의 표면을 주사전자현미경으로 관찰하였다. 또한, 굽힘 강도 비교를 위해 의치상 레진에 이산화티타늄 나노입자를 0.5, 1, 1.5, 2 wt%의 중량비로 혼합하고, 길이 64 mm, 높이 10 mm, 폭 3 mm 형태(ISO 20795-1)의 시편을 각 군당 20개씩 출력하였고, 만능시험기로 3점 굽힘 강도 시험을 시행하였다. 결과: C.albicans의 집락수와 배양액의 흡광도는 연마를 시행하지 않은 군에서 차이가 없었으나, 연마를 시행한 군에서는 대조군에 비해 감소하였다. 굽힘 강도는 이산화티타늄 나노입자 농도 0, 1, 1.5 wt%에서 증가하였으나 2 wt%에서 1.5 wt%에 비해 감소하였다. 결론: 3D 프린팅 의치상 레진에 이산화티타늄 나노입자를 1.5 wt% 첨가하였을 때, 의치상 레진의 항진균성과 굽힘 강도가 증가하였다.

광중합형 글래스 아이오노머 시멘트 교정용 브라켓의 전단결합강도에 미치는 영향 (THE EFFECT OF LIGHT CURED GLASS IONOMER CEMENT ON THE SHEAR BOND STRENGTH OF ORTHODONTIC BRACKETS)

  • 김철;윤영주;김광원
    • 대한치과교정학회지
    • /
    • 제27권2호
    • /
    • pp.327-334
    • /
    • 1997
  • 광중합형 글래스 아이오노머 시멘트(Fuji Ortho $LS^{(R)}$)와 화학중합형 레진 시멘트(Mono $Lok2^{(R)}$)을 선택하여 사람의 소구치를 대상으로 법랑질을 퍼미스 및 10% 폴리아크릴산, 38%인산으로 표면처리한 후 금속 및 프라스틱 브라켓을 부착하고 섭씨 $37^{\circ}C$의 생리 식염수에 24시간, 48시간 경과 시키고 만능강도시험기를 이용하여 전단결합강도를 측정하고 비교함으로써 교정용 접착제로서 광중합형 글래스 아이오노머 시멘트가 임상적 적용 가능성이 있는지 여부를 규명하고자 시행하여 다음과 같은 결론을 얻었다. 1. 퍼미스로 법랑질을 표면처리한 광중합형 글래스 아이오노머 시멘트군의 전단결합강도는 화학중합형 레진군의 결합 강도보다 유의성 있게 낮았다(P<0.01). 2. 10% 폴리아크릴산으로 법랑질을 표면처리한 광중합형 글래스 아이오노머 시멘트군의 전단 결합강도는 화학중합형 레진군보다 유의성이 낮았다(PC0.01). 3. 10% 폴리아크릴산으로 법랑질을 표면처리한 광중합형 글래스 아이오노머 시멘트군의 전단결합강도는 피미스로 법랑질을 표면처리한 광중합형 글래스 아이오노머 시멘트군보다 약간 높았으나 통계적으로 유의성이 없었다(P<0.05). 4. 메탈과 플라스틱군의 법랑질 표면처리에 관계없이 통계적으로 유의성이 없었다(P<0.05). 이상의 결과를 종합해볼 때 비록 광중합형 글래스 아이오노머 시멘트가 화학중합형 레진 시멘트보다 결합강도는 낮지만 이의 임상적 적용은 가능할 것으로 사료된다.

  • PDF

Effect of Commercial Effervescent Vitamin Tablets on Bovine Enamel

  • Jeong, Moon-Jin;Lee, Myoung-Hwa;Jeong, Soon-Jeong;Kim, So-Jeong;Ko, Myeong-Ji;Sim, Hye-Won;Lee, Ju-Young;Im, Ae-Jung;Lim, Do-Seon
    • 치위생과학회지
    • /
    • 제19권4호
    • /
    • pp.261-270
    • /
    • 2019
  • Background: In this study, four types of effervescent vitamins marketed in Korea were analyzed for their acidity and vitamin content. For this purpose, bovine teeth were immersed in vitamin, and surface microhardness and appearance were measured before and after immersion to evaluate tooth demineralization and erosion. Methods: Bovine permanent incisors with sound surface enamel were cut to 5×5 mm size, embedded in acrylic resin, and polished using a polishing machine with Sic-paper. The prepared samples were analyzed for pH, vitamin content, and surface hardness before and after immersion using a surface microhardness meter. Demineralization of surface dental enamel was observed using a scanning electron microscope. Results: The average pH of the four effervescent vitamins was less than 5.5; the pH of the positive control Oronamin C was the lowest at 2.76, while that of the negative control Samdasoo was the highest at 6.86. The vitamin content was highest in Berocca and lowest in the DM company Multivitamin. On surface microhardness analysis, surface hardness values of all enamel samples were found to be decreased significantly after 1 and 10 minutes of immersion (p<0.05). After 10 minutes of immersion, there was a significant difference in the decrease in hardness between the experimental groups (p<0.05). Scanning electron microscopy observation showed that dental enamel demineralization after 10 minutes of immersion was the most severe in Oronamin C except for Samdasoo, followed by DM company Multivitamin and VitaHEIM. Immersion in BeroNew and Berocca resulted in similar effects. Conclusion: There is a risk of tooth erosion due to decreased tooth surface microhardness when using the four types of effervescent vitamins and vitamin carbonated beverages with pH below 5.5. Therefore, high pH vitamin supplements are recommended to prevent tooth erosion.

Nd:YAG 레이저를 이용한 철제 표면 옻칠 제거 실험 연구 (Experimental Study for Removing Lacquer Layer on Iron Surface by Nd:YAG Laser System)

  • 박창수;조남철;황현성
    • 보존과학회지
    • /
    • 제32권3호
    • /
    • pp.377-384
    • /
    • 2016
  • 철불의 개금 시 표면에 남아 있는 옻칠 제거 방법에는 물리적인 방법과 화학적인 방법을 사용하고 있으나, 표면 손상 및 약품 사용으로 인한 환경오염, 보존과학자의 건강에도 매우 유해하다. 그래서 본 연구에서는 비접촉식이고 친환경적인 Nd:YAG 레이저를 이용하여 옻칠 제거 실험을 실시하였다. 시편은 크기가 $5{\times}5cm$인 철제(Fe 99.9%)시편 표면을 균일하게 연마한 후 생칠을 도포 횟수를 달리하여 각각 $10{\mu}m$, $20{\mu}m$, $30{\mu}m$의 두께 차이로 제작하였다. 본 실험에서 사용된 레이저기기는 Nd:YAG 레이저로, 적외선 영역의 1064 nm(160~800 mJ)와 가시광선 영역인 532nm(50~350 mJ)의 두 가지 파장 모드를 이용하였다. 실험은 레이저 파장 에너지 조사 횟수 등에 따른 시편 표면의 변화를 조사하였다. 레이저 조사 전 후 표면을 실체현미경과 SEM 관찰, 비접촉 표면 조도 측정기, FT-IR 등을 이용하여 옻칠의 제거 및 잔류 여부를 알아보았다. 분석 결과 1064 nm 파장을 이용하여 $1.0J/cm^2$ 밀도에서 표면 손상 없이 $10{\mu}m$, $20{\mu}m$ 두께의 옻칠이 제거됨을 확인할 수 있었다. 이와 같은 결과를 통해 철불 개금 시 잔류하고 있는 옻칠 제거 방법으로 Nd:YAG 레이저가 효율적임을 본 실험을 통해 알 수 있었다. 향후 금속뿐만 아니라 목칠 가구 등 다양한 재질의 연구가 이루어지면 표면 손상 없이 옻칠을 제거 하는데 효과적으로 활용 가능할 것으로 본다.

Performance Improvement of Near Earth Space Survey (NESS) Wide-Field Telescope (NESS-2) Optics

  • Yu, Sung-Yeol;Yi, Hyun-Su;Lee, Jae-Hyeob;Yim, Hong-Suh;Choi, Young-Jun;Yang, Ho-Soon;Lee, Yun-Woo;Moon, Hong-Kyu;Byun, Yong-Ik;Han, Won-Yong
    • Journal of Astronomy and Space Sciences
    • /
    • 제27권2호
    • /
    • pp.153-160
    • /
    • 2010
  • We modified the optical system of 500 mm wide-field telescope of which point spread function showed an irregularity. The telescope has been operated for Near Earth Space Survey (NESS) located at Siding Spring Observatory (SSO) in Australia, and the optical system was brought back to Korea in January 2008. After performing a numerical simulation with the tested value of surface figure error of the primary mirror using optical design program, we found that the surface figure error of the mirror should be fabricated less than root mean square (RMS) $\lambda$/10 in order to obtain a stellar full width at half maximum (FWHM) below $28\;{\mu}m$. However, we started to figure the mirror for the target value of RMS $\lambda$/20, because system surface figure error would be increased by the error induced by the optical axis adjustment, mirror cell installation, and others. The radius of curvature of the primary mirror was 1,946 mm after the correction. Its measured surface figure error was less than RMS $\lambda$/20 on the table of polishing machine, and RMS $\lambda$/15 after installation in the primary mirror cell. A test observation performed at Daeduk Observatory at Korea Astronomy and Space Science Institute by utilizing the exiting mount, and resulted in $39.8\;{\mu}m$ of stellar FWHM. It was larger than the value from numerical simulation, and showed wing-shaped stellar image. It turned out that the measured-curvature of the secondary mirror, 1,820 mm, was not the same as the designed one, 1,795.977 mm. We fabricated the secondary mirror to the designed value, and finally obtained a stellar FWHM of $27\;{\mu}m$ after re-installation of the optical system into SSO NESS Observatory in Australia.

치과도재의 Glazing 여부에 따른 수분침투 정도와 굽힘강도에 미치는 영향 (Influence of Water Infiltration and Flexural Strength Change with Glazing Treatment of Dental Porcelain)

  • 이주희;이채현;송정환
    • 치위생과학회지
    • /
    • 제17권4호
    • /
    • pp.358-367
    • /
    • 2017
  • 본 연구에서는 소성한 치과도재 시편에 대해 glazing 처리 여부에 따른 수분 침투와 기계적 물성의 비교분석을 통해 glazing 처리의 중요한 의미를 도출하고자 하였다. 또한, 제한된 가속 시효처리 방법으로 구강 내 환경에서 치과용 수복물의 내구수명 예측이 가능하였으며 수분 내에서 가속 시효처리를 통하여 치과도재는 수분 노출로 인한 열화가 일어나고 굽힘강도 저하 현상을 보였다. 치과도재의 glazing 처리를 통해 연마 시 발생하는 시편 표면의 흠집 또는 소성시 발생하는 미세균열이나 기공의 노출을 억제함으로써 굽힘강도 향상 결과를 보였다. 또한 glazing 처리한 시편이 가속 시효처리의 시간이 증가할수록 강도 저하 현상을 보이긴 하지만 glazing 처리를 하지 않은 시편과 비교하여 볼 때, 열화되는 속도가 작은 것을 알 수 있었다. 따라서 구강 내에서 치과도재 보철의 내구성을 확보하기 위해서 영구장착 전 glazing 처리를 반드시 시행할 것을 권하며, 수분 침투 억제 방법에 대해서도 향후 체계적인 연구가 되어야 할 것으로 생각한다.