• 제목/요약/키워드: Polisher

검색결과 57건 처리시간 0.023초

임플란트-지대주-나사의 적합에 관한 연구 (A STUDY ON THE FIT OF THE IMPLANT-ABUTMENT-SCREW INTERFACE)

  • 김낙형;정재헌;손미경;백대화
    • 대한치과보철학회지
    • /
    • 제41권4호
    • /
    • pp.503-518
    • /
    • 2003
  • Statement of problem : There have been previous studies about considerable variations in machining accuracy and consistency in the implant-abutment-screw interfaces. Purpose : The purpose of this study was to evaluate the machining accuracy and consistency of implant/abutment/screw combinations on two randomly selected implants from each of four manufactures. Material and methods : In this study, screws were respectively used to secure a cemented abutment, to a hexlock implant fixture ; teflon coated titanium alloy screw(Torq-Tite) and titanium alloy screw in Steri--Oss system, gold-plated gold-palladium alloy screw(Gold-Tite) and titanium alloy screw in 3i system gild screw ana titanium screw in AVANA Dental Implant system, and titanium screws in Paragon System. The implants were perpendicularly mounted in polymethyl methacrylate autopolymerizing acrylic resin block(Orthodontic resin, Densply International Inc. USA) by use of dental surveyer. Each abutment screw was secured to the implant with recommended torque value using a digital torque controller. Each screw was again tightened after 10 minutes. All samples were cross sectioned with grinder-polisher unit(Omnilap 2000 SBT Inc) after embeded in liquid unsaturated polyester (Epovia, Cray Valley Inc) Results : There were the largest gaps in the neck areas of screws in hexagonal extension implants which were examined in this study. The leading edge of the abutment screw thread (superior surface) was in contact with the implant body thread, and the majority of the contacting surfaces were localized to the middle portion of the mating threads. Considerable variation in the contacting surfaces was noted in the samples evaluated. Amounts of contact in the abutment screw thread were larger for assemblies with Gold-Tite screw, gold alloy screw. Torq-Tite screw than those with titanium screws. The findings of intimate contact between the screw and screw seat were seen in all samples, regardless of manufacturers. However, microgap between the head and lateral neck surface of the screw and the abutment could be dectected in all samples. The findings of intimate contact between the platform of the implant and the bottom of the abutment were consistent in all samples, regardless of manufacturers. However, microgaps between the lateral surface of external hex of the fixture and the abutment could be dectected in all samples. Conclusion : Considerable variations in machining accuracy and consistency were noted in the samples and the implant-abutment-screw interfaces were incomplete. From the results of this study, further development of the system will be required, including improvements in pattern design.

내측연결 임플란트 시스템에서 고정체와 지대주 연결부의 적합에 관한 연구 (FIT OF FIXTURE/ABUTMENT INTERFACE OF INTERNAL CONNECTION IMPLANT SYSTEM)

  • 이흥태;정재헌
    • 대한치과보철학회지
    • /
    • 제42권2호
    • /
    • pp.192-209
    • /
    • 2004
  • Purpose : The purpose of this study was to evaluate the machining accuracy and consistency of implant/abutment/screw combination or internal connection type. Material and methods: In this study, each two randomly selected internal implant fixtures from ITI, 3i, Avana, Bicon, Friadent, Astra, and Paragon system were used. Each abutment was connected to the implant with 32Ncm torque value using a digital torque controller or tapping. All samples were cross-sectioned with grinder-polisher unit (Omnilap 2000 SBT Inc) after embeded in liquid unsaturated polyester (Epovia, Cray Valley Inc). Then optical microscopic and scanning electron microscopic(SEM) evaluations of the implant-abutment interfaces were conducted to assess quality of fit between the mating components. Results : 1) Generally, the geometry of the internal connection system provided for a precision fit of the implant/abutment into interface. 2) The most precision fit of the implant/abutment interface was provided in the case of Bicon System which has not screw. 3) The fit of the implant/abutment interface was usually good in the case of ITI, 3I and Avana system and the amount of fit of the implant/abutment interface was similar to each other. 4) The fit of the implant/abutment interface was usually good in the case of Friadent, Astra and Paragon system. The case of Astra system with the inclined contacting surface had the most Intimate contact among them. 5) Amount of intimate contact in the abutment screw thread to the mating fixture was larger in assembly with two-piece type which is separated screw from abutment such as Friadent, Astra and Paragon system than in that with one-piece type which is not seperated screw from abutment such as ITI, 3I and Avana system. 6) Amount of contact in the screw and the screw seat of abutment was larger in assembly of Friadent system than in asembly of Astra system of Paragon system. Conclusion: Although a little variation in machining accuracy and consistency was noted in the samples, important features of all internal connection systems were the deep, internal implant-abutment connections which provides intimate contact with the implant walls to resist micro-movement, resulting in a strong stable interface. From the results of this study, further research of the stress distribution according to the design of internal connection system will be required.

연마방법에 따른 금속의 활택도에 관한 연구 - Atomic Force Microscope를 이용한 - (A STUDY ON SURFACE ROUGHNESS OF METALS ACCORDING TO FINISHING AND POLISHING PROCEDURES - AN ATOMIC FORCE MICROSCOPE ANALYSIS -)

  • 박원규;우이형;최부병;이성복
    • 대한치과보철학회지
    • /
    • 제41권1호
    • /
    • pp.1-19
    • /
    • 2003
  • The surface of metals should be as smooth as possible for optimum comfort, oral hygiene, low plaque retention, and resistance to corrosion. In this study five specimens of each precious metal(type III gold alloy, ceramic gold alloy, and Ag-Pd alloy) were divided into five groups according to finishing and polishing procedures : group 1(sandblaster), group 2(group 1+stone), group 3(group 2+brown rubber), group 4(group 3+green rubber), and group 5(group 4+rouge). Six specimens of each non-precious metal(Co-Cr alloy, Ni-Cr alloy, and Co-Cr-Ti alloy) were divided into six groups: group 1(sandblaster), group 2(group 1+hard stone), group 3(group 2+electrolytic polisher), group 4(group 3+brown hard rubber point), group 5(group 4+green hard rubber point), and group 6(group 5+rouge). Considering factors affecting the rate of abrasion, the same dentist applied each finishing and polishing procedure. In addition, the surface roughness of enamel, resin, and porcelain was evaluated. The effect of finishing and polishing procedures on surface roughness of precious and non-precious metals, enamel, resin, and porcelain was evaluated by means of Atomic Force Microscope(AutoProbe CP. Park Scientific Instruments, U.S.A.) that can image the three dimensional surface profile and measure average surface roughness values of each sample at the same time. The obtained results were as follows : 1. According to finishing and polishing procedures, the surface roughness of type III gold alloy, ceramic gold alloy, and Ag-Pd alloy was decreased in the order of group 1, 2, 3, 4, and 5 (P<0.01). 2. According to finishing and polishing procedures. the surface roughness of Co-Cr alloy, Ni-Cr alloy, and Co-Cr-Ti alloy was decreased in the order of group 1, 2, 3, 4, 5, and 6 (p<0.01). 3. There was not statistically significant difference in the surface roughness among three metals of precious metals in group 1 but was significant difference in group 2, 3, 4, and 5 (P<0.05). 4. There was not statistically significant difference in the surface roughness among three metals of non-precious metals in all groups. 5. When the surface roughness of the smoothest surface of each metal, enamel. porcelain, and resin was compared, porcelain was the smoothest and the surface roughness was decreased in the order of Ni-Cr alloy. Co-Cr alloy. Co-Cr-Ti alloy, resin. Ag-Pd alloy, ceramic gold alloy type III gold alloy, and enamel (P<0.01). The results of this study indicate that the finishing and polishing procedures should be carried out in a logical, systematic sequence of steps and the harder non-precious metals may be less resistance to abrasion than are the softer precious metals.

주입선 및 열처리에 따른 IPS Empress 도재의 미세구조에 관한 연구 (A STUDY ON THE MICROSTRUCTURE OF IPS EMPRESS CERAMICS ACCORDING TO THE HEAT TREATMENT AND SPRUE TYPE)

  • 동진근;오상천
    • 대한치과보철학회지
    • /
    • 제36권5호
    • /
    • pp.772-785
    • /
    • 1998
  • This study was undertaken to clarify the microstructure of the different IPS Empress ingots by etching and to observe the change of leucite crystal structure according to subsequent heat treatment and the crystal distribution according to sprue types(${\phi}2.8mm$, single sprue; ${\phi}1.8mm$, double sprue) by scanning electron microscopy. IPS Empress T1, O1 ingots used for staining technique, and Dentin(A2) ingots used for layering technique were selected for this study. To observe the microstructures of these ingots before pressing, the specimens were prepared in splinters($3{\times}3{\times}3mm$) taken from the original ingots. And to estimate crystal distribution and microstructural change by sprue type and subsequent heat treatment. the specimens($3{\times}3{\times}3mm$) were heat-pressed through the two types of sprues with different diameters and numbers, and all specimens were fired according to the recommended firing schedule. The observed surface was ground with waterproof papers($#800{\sim}#1800$) on the grind polisher and was cleaned ultrasonically. All specimen were etched with 0.5% hydrofluoric acid. After etching, the surface was treated by ion sputter coating for SEM observation at an accelerating voltage of 20kV. In all specimens, the central area of ground surface was observed because there was less difference in microstructure between the peripheral area and the central area. The results were as follows ; 1. In the microstructure according to the ingot type, there was a wide difference between the staining (T1,O1) and layering(Dentin A2) ingots, but there was not a considerable difference between the T1 ingot and the O1 ingot for staining technique. 2. In all specimens, the crystal dispersion of IPS Empress ceramic using double sprue was significantly more scattered than that of IPS Empress ceramic using single sprue. The degree of scattering was strongest in the Dentin(A2) specimen and weakest in the O1 ingot. 3. In the microstructural change according to the subsequent heat treatment, all of ingots had some microcracks in the inside of the leucite crystal and the glass matrix after pressing. The inner splinters of the leucite crystal became smaller, and more microcracks occurred in the glass matrix due to increasing heat treatment times. 4. The size of leucite crystals varied from $1{\mu}m\;to\;5{\mu}m$. The mean size of mature crystals was about $5{\mu}m$. The form of the crystal was similar to a circle when it was smaller and similar to an ellipse when it was larger.

  • PDF

다양한 치태조절기구가 타이타늄 임프란트의 표면조도와 형태에 미치는 영향 (The Effect of Various Plaque Control Devices on Roughness and Morphology of Titanium Implant Surface)

  • 최승환;임정수;송인택;김형섭
    • Journal of Periodontal and Implant Science
    • /
    • 제28권2호
    • /
    • pp.337-350
    • /
    • 1998
  • The purpose of this' study was to compare surface roughness and morphologic changes after use of various plaque control devices to titanium implant surfaces. The study materials were 6 ITI titanium implants($Bonefit^{(R)}$) and 5 plaque control devices. 6 implants were divided into 6 different groups and instrumented by each plaque control devices as follows. 1) Group I : untreated control 2) Group II : Titanium curette(Titanium $curette^{(R)}$, 3i) 80 vertical/horizontal strokes 3) Group III : Plastic curette($Implacare^{(R)}$, Hu-Friedy) 80 vertical/horizontal strokes 4) Group N : Plastic tip-ultrasonic scaler($Amdent^{(R)}$, Amdent) 160 seconds 5) Group V : Rotating interdental brush($Identobrush^{(R)}$, Identoflex) 160 seconds 6) Group VI : Abrasive rubber cup polisher($Zircate^{(R)}$, Prophy paste, Dentsply) 160 sec-onds. All specimens were prepared for evaluation by surface roughness tester, optical stereomicroscopy(OM) and scanning electron microscopy(SEM). The Ra and Rt mean values of the tested specimens were 1) Group I ($Ra=0.170{\pm}0.007{\mu}m$, $Rt=1.297{\pm}0.016{\mu}m$) 2) Group II ($Ra=0.209{\pm}0.006{\mu}m$, $Rt=1.602{\pm}0.110{\mu}m$) 3) Group III ($Ra=0.179{\pm}0.001{\mu}m$, $Rt=1.429{\pm}0.055{\mu}m$) 4) Group IV ($Ra=0.182{\pm}0.005{\mu}m$, $Rt=1.511{\pm}0.085{\mu}m$) 5) Group V ($Ra=0.301{\pm}0.008{\mu}m$, $Rt=1.882{\pm}0.131{\mu}m$) 6) Group VI ($Ra=0.147{\pm}0.010{\mu}m$, $Rt=1.059{\pm}0.021{\mu}m$) In Ra values, experimental group II, V, VI were statistically significant different when compared with control. OM and SEM observation showed that experimental group III, IV were minimal changes when compared with control and group VI was smoothest among other experimental groups. The results suggested that plastic curette and plastic tip-ultrasonic scaler were predictable devices to titanium implant surface.

  • PDF

전동공구 회사의 제품사양별 디자인개발특성 비교연구 -보슈(BOSCH), 블랙앤데커(BLACK&DECKER), 계양전기 사례를 중심으로 - (A Comparative Study on Power Tool Manufacturers' Products Spec. and Design Development Features - By the Case Study on BOSCH, BLACK&DECKER and KEYANG Electrics-)

  • 채승진
    • 디자인학연구
    • /
    • 제17권1호
    • /
    • pp.383-392
    • /
    • 2004
  • 본 연구의 목적은 우리나라에 유통되는 전동공구를 중심으로 사양과 디자인에 대한 비교를 통하여 각 제조사 디자인속성과 디자인 전략을 파악하는 것이다. 연구범위는 이 분야의 대표적인 3개 생산업체와 이들의 발전과정과 출시제품이며 연구방법은 각 제조업체의 제품 출시 수준(제품라인: product line)과 제품군별 다양화 수준(제품믹스: product mix)의 조사 비교, 그리고 이를 이미지 맵(image map)에 배치하여 디자인의 속성을 비교하는 것으로 했다. 전동공구는 동력원인 모터를 이용하여 각종 구조물을 제조ㆍ가공하는데 사용되는 공구로 구조적으로는 조립제품의 특징을 갖고 있고, 일반 사양은 소형, 경량인데다 견고한 제품속성과 함께 각 사양별로 규격과 종류가 다양한 것이 일반 소비재와 다른 점이다. 제품의 가장 중요한 요구조건이 사용 간편성과 우수성능이다. 이 때문에 장착 모터의 성능, 기어(gear)부의 정밀성, 내마모성 등이 전동공구의 품질을 좌우한다. 전동공구는 가정에서부터 중공업에 이르기까지 폭넓게 사용되고 있으며 기계, 자동차, 조선, 항공, 전자 공업 등 첨단 산업의 핵심 분야이다. 전동공구는 종류에 따라 전기 드릴 류, 전기 그라인더, 전기 톱, 전기샌더 등으로 구분할 수 있으며 사용자에 따라 산업용과 가정용으로 구분할 수 있다. 또한 작업용도별로 천공 작업용, 연삭 작업용, 연마 작업용, 체결 작업용, 절단 작업용으로 분류할 수 있다. 보슈(BOSCH), 블랙앤데커(BLACK&DECKER), 계양전기의 전동공구들을 제품라인과 제품믹스로 분류하여 각 업체의 제품특성을 비교하는 방법으로 이미지 스케일을 적용하였으며 이를 통하여 각 기업의 디자인개발 전략에 대하여 기초적 수준의 특성을 파악할 수 있었다. 이미지 맵의 파라미터는 각 업체별 제품의 컬러, 형태 및 하우징에 사용된 재료로 하였고 이를 통하여 디자인의 지향성을 비교분석할 수 있었다. 이에 부가적으로 동급제품을 각각 선정하여 이들의 성능에 대한 수평비교와 심층 분석을 통해 기술력, 품질, 성능 등의 차이점도 알아보았다. 비록 기초적 수준의 조사지만 이 과정을 통하여 전동공구의 시장의 일반 특성, 각 기업의 제품특성과 시장목표, 제품전략 등을 비교해 봄으로써 향후 전동공구 시장의 방향 예측과 디자인에 대한 개발전략의 기초 마련에 기여하고자 했다.

  • PDF

스퍼터링 증확 CdTe 박막의 두께 불균일 현상 개선을 위한 화학적기계적연마 공정 적용 및 광특성 향상 (Application of CMP Process to Improving Thickness-Uniformity of Sputtering-deposited CdTe Thin Film for Improvement of Optical Properties)

  • 박주선;임채현;류승한;명국도;김남훈;이우선
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.375-375
    • /
    • 2010
  • CdTe as an absorber material is widely used in thin film solar cells with the heterostructure due to its almost ideal band gap energy of 1.45 eV, high photovoltaic conversion efficiency, low cost and stable performance. The deposition methods and preparation conditions for the fabrication of CdTe are very important for the achievement of high solar cell conversion efficiency. There are some rearranged reports about the deposition methods available for the preparation of CdTe thin films such as close spaced sublimation (CSS), physical vapor deposition (PVD), vacuum evaporation, vapor transport deposition (VTD), closed space vapor transport, electrodeposition, screen printing, spray pyrolysis, metalorganic chemical vapor deposition (MOCVD), and RF sputtering. The RF sputtering method for the preparation of CdTe thin films has important advantages in that the thin films can be prepared at low growth temperatures with large-area deposition suitable for mass-production. The authors reported that the optical and electrical properties of CdTe thin film were closely connected by the thickness-uniformity of the film in the previous study [1], which means that the better optical absorbance and the higher carrier concentration could be obtained in the better condition of thickness-uniformity for CdTe thin film. The thickness-uniformity could be controlled and improved by the some process parameters such as vacuum level and RF power in the sputtering process of CdTe thin films. However, there is a limitation to improve the thickness-uniformity only in the preparation process [1]. So it is necessary to introduce the external or additional method for improving the thickness-uniformity of CdTe thin film because the cell size of thin film solar cell will be enlarged. Therefore, the authors firstly applied the chemical mechanical polishing (CMP) process to improving the thickness-uniformity of CdTe thin films with a G&P POLI-450 CMP polisher [2]. CMP process is the most important process in semiconductor manufacturing processes in order to planarize the surface of the wafer even over 300 mm and to form the copper interconnects with damascene process. Some important CMP characteristics for CdTe were obtained including removal rate (RR), WIWNU%, RMS roughness, and peak-to-valley roughness [2]. With these important results, the CMP process for CdTe thin films was performed to improve the thickness-uniformity of the sputtering-deposited CdTe thin film which had the worst two thickness-uniformities of them. Some optical properties including optical transmittance and absorbance of the CdTe thin films were measured by using a UV-Visible spectrophotometer (Varian Techtron, Cary500scan) in the range of 400 - 800 nm. After CMP process, the thickness-uniformities became better than that of the best condition in the previous sputtering process of CdTe thin films. Consequently, the optical properties were directly affected by the thickness-uniformity of CdTe thin film. The absorbance of CdTe thin films was improved although the thickness of CdTe thin film was not changed.

  • PDF