• Title/Summary/Keyword: Pole Transformer

Search Result 108, Processing Time 0.026 seconds

Practical Study on Adjustment of Load Correlation Equations of Pole Transformer (주상변압기 부하 상관식 조정에 관한 실증적 연구)

  • 박창호;김두봉;김기현;배주천;윤상윤;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.1
    • /
    • pp.102-108
    • /
    • 2000
  • This paper presents a result of practical study about the adjustment of load correlation equation for the load management of pole transformer. For adjusting the load correlation equation, we analyze the correlative relation between working electric energy[kWh] and peak load[A]. To enhance the accuracy of correlation equation, we classify the 12 representative area patterns. And then, we select the 24 sample pole transformer for each area pattern. For the reliability of the data using the load correlation equation, load management equipment is utilized for each sample pole transformer. Through the on-line data acquisition, we construct the database. For adjusting the load correlation equation, we consider the two points. One is the goodness of fitness for load correlation equation and the other is prevention of pole transformer damage due to the overload. Finally, we propose the correlation equation using the linear and quadratic equation all at once. Through the case studies, we verify that the proposed load correlation equation is reduced the error ratio than conventional correlation equation.

  • PDF

The Design and Performance Test of Mold Transformer for Outdoor Pole (50 kVA 주상용 몰드변압기의 설계 및 특성평가)

  • Cho, Han-Goo;Lee, Un-Yong;HwangBo, Kuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.132-137
    • /
    • 2002
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss. The life of transformer is significantly dependent on the thermal behavior in windings. To analyse winding temperature rise, many transformer designer have calculated temperature distribution and hot spot point by finite element method(FEM). Recently, numerical analyses of transformer are studied for optimum design, that is electric field analysis, magnetic field, potential vibration, thermal distribution and thermal stress. In this paper, the temperature distribution of 50 kVA pole mold transformer for power distribution are investigated by FEM program and the temperature rise test of designed mold transformer carried out and test result is analyzed compare to simulation data. In this result, the designed mold transformer is satisfied to limit value of temperature and the other property is good such as voltage ratio, winding resistance, no-load loss, load loss, impedance voltage and percent regulation.

  • PDF

Surface Ageing Property of Polymer Insulator for Transmission line with Forest Fire Test (H종 주상용 몰드 변압기의 덕크구조에 따른 열해석 특성)

  • Cho, Han-Goo;Kim, Kyang-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.111-111
    • /
    • 2010
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss, but it needs some cooling method because heat radiation between each winding is difficult. In this paper, the temperature distribution and thermal stress analysis of H class 100kVA pole cast resin transformer for power distribution are investigated by FEM program.

  • PDF

A study on the Development of the Shell-type Pole Transformer Using the Zig-Zag Winding (Zig-Zag 귄선에 의한 내철형 주상변압기 개발에 관한 연구)

  • Min, Yun-Hong;Shin, Dae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.121-128
    • /
    • 2007
  • In this thesis, we would show how to lay out and produce the shell-type transformer using the world's first Zig-Zag winding way, instead of a general winding. Also, we omit the progress of varnish-impregnation, so that we could develop the new shell-type transformer winding which improves the short-circuit characteristics and dielectric strength. It has a copernican effect to reduce the thickness and the number of insulation papers, as compared with a general winding transformer. We would prove that it is far superior in cost reduction, loss reduction, and mechanical force of short-circuit. And eventually you must find it useful in the pole transformer for power distribution in the domestic power companies.

Adjustment of Load Regression Coefficients and Demand-Factor for the Peak Load Estimation of Pole-Type Transformers (주상 변압기 최대부하 추정을 위한 부하상관계수 및 수용율 조정)

  • Yun, Sang-Yun;Kim, Jae-Chul;Park, Kyung-Ho;Moon, Jong-Fil;Lee, Jin;Park, Chang-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.2
    • /
    • pp.87-96
    • /
    • 2004
  • This paper summarizes the research results of the load management for pole transformers done in 1997-1998 and 2000-2002. The purpose of the research is to enhance the accuracy of peak load estimation in pole transformers. We concentrated our effort on the acquisition of massive actual load data for modifying the load regression coefficients, which related to the peak load estimation of lamp-use customers, and adjusting the demand-factor coefficients, which used for the peak load prediction of motor-use customers. To enhance the load regression equations, the 264 load data acquisition devices are equipped to the sample pole transformers. For the modification of demand factor coefficients, the peak load currents are measured in each customer and pole transformer for 13 KEPCO (Korea Electric Power Corporation) distribution branch offices. Case studies for 50 sample pole transformers show that the proposed coefficients could reduce estimating error of the peak load for pole transformers, compared with the conventional one.

A Study on Monthly Electric Energy Estimation of Pole-Transformer Using NLRE Curve (NLRE 곡선을 이용한 주상 변압기 월간 사용전력량 추정에 관한 연구)

  • Im, Jin-Soon;Yun, Sang-Yun;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.58-60
    • /
    • 2000
  • In this paper we present an estimation method of electric energy[kWh] for load management of pole-transformer. For the electric energy estimation, we use the nonlinear load research based estimation(NLRE) algorithm. The NLRE curve is the normalized annual cumulative energy consumption for a particular day in a year. And, it is used for the coefficient estimation. Estimation method of suggested electric energy of pole-transformer used billing cycle electric energy estimation equation is verified as comparison billing cycle electric energy and estimated electric energy. We can reduce the error of peak load estimation by suggested method than the conventional method in domestic.

  • PDF

Adjustment of correlation coefficient for Pole transformer's load estimation and its reliability verification. (배전변압기의 전등부하 추정을 위한 상관계수 산정 및 신뢰성 검증)

  • Park, Chang-Ho;Han, Yong-Hee;KIm, Joon-Ho;Cho, Seong-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1073-1075
    • /
    • 1999
  • This Paper Presents the process of load management for distribution Pole transformer at KEPCO. The purpose of this process is to establish reasonable peak load forecasting and prevention of Pole transformer damages caused by overload through the investigation of correlation coefficient for recent load characteristics. In this Paper, we newly proposed more reliable correlation coefficient using improved method and verified its reliability in various ways.

  • PDF

Islanding Prevention Method for Photovoltaic System by Harmonic Injection Synchronized with Exciting Current Harmonics of Pole Transformer

  • Yoshida, Yoshiaki;Fujiwara, Koji;Ishihara, Yoshiyuki;Suzuki, Hirokazu
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.3
    • /
    • pp.331-338
    • /
    • 2014
  • When large penetration of the distributed generators (DGs) such as photovoltaic (PV) systems is growing up in grid system, it is important to quickly prevent islanding caused by power system fault to ensure electrical safety. We propose a novel active method for islanding prevention by harmonic injection synchronized with the exciting current harmonics of the pole transformer to avoid mutual interference between active signals. We confirm the validity of the proposed method by performing the basic tests of islanding by using a current source superimposed the harmonic active signal. Further, we carry out the simulation using PSCAD/EMTDC, and verify the fast islanding detection.

A Study on the Age Degradation Kinetics of Pole Transformer Oil (주상변압기 절연유의 경년열화반응 속도론에 관한 연구)

  • 남영우
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.1
    • /
    • pp.99-105
    • /
    • 1997
  • In the paper, aging of insulating oil in pole transformer has been studied by performing accelerated thermal aging test. Dissolved gases were extracted by air bubbling method. Concentration of dissolved gases were modified by extraction ratio of each gases in insulating oil. Aging of insulating materials were proceeded by thermal degradation and oxidation reaction. Both of the reactions followed zeroch order kinetics. Formation rate equations for hydrocarbons, carbon oxides, and hydrogen were derived. It was conformed by gas analysis and UV-Visible spectrophotometric method that iron core and copper coil in pole transformer act as catalyst during the aging process.

  • PDF

Research on Dielectric Characteristics of Environmental-Friendly Vegetable Insulation Oil for the Pole Transformer (주상변압기 적용을 위한 친환경 식물성절연유의 절연특성 연구)

  • Kwag, Dong-Soon
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.81-85
    • /
    • 2010
  • In recent years, environmental concerns have been raised on the use of poorly biodegradable fluids in electrical apparatus in regions where spills from leaks and equipment failure could contaminate the surroundings. The vegetable insulation oils are highly biodegradable, have negligible effect on the environment, human health and ecosystem. Therefore, to assure their safe use in electrical power systems, it may require some processing and modification to improve some of their physical, chemical, thermal and electrical properties. This paper provides a comparative results of the electrical breakdown properties of several vegetable insulation oils and mineral oil to use as dielectric fluid in environmental-friendly pole transformer. Also, the electrical breakdown property of the Nomex and kraft insulation papers in vegetable insulation oil is examined.