콘덴서 제어회로를 이용한 배전용 변압기의 역률 개선에 관한 연구 (A Study for Improving the Power Factor of Distribution Transformer using Condenser Control Circuit)

  • 이광직
    • 조명전기설비학회논문지
    • /
    • 제28권4호
    • /
    • pp.21-28
    • /
    • 2014
  • Daily use characteristics of apparent power supplied to distribution transformer can be separated into two different time zone of waking hours and sleeping hours. In sleeping hours, using amount of power is decreasing. The actual curve of power seemed to be quite similar to this kind of separation. Inserting a condenser into a circuit in each different time zone led to maximize power factor of the transformer. The compensating condenser's on/off time is controlled by hysteresis circuit utilizing op amp and power factor of the transformer was improved from 0.945 to 0.999. As a result, the average of current reduction was 2.53A per hour of transformer.

평면형 능동 위상 배열 레이더용 안테나 시스템 개발 (Developement of Planar Active Array Antenna System for Radar)

  • 전상미;나형기;김수범;이정원;김동윤;김선주;안창수;이창희
    • 한국전자파학회논문지
    • /
    • 제20권12호
    • /
    • pp.1340-1350
    • /
    • 2009
  • 본 논문에서는 레이더용 평면형 능동 위상 배열 안테나 시스템의 설계 및 제작 그리고 측정 결과를 소개한다. 설계된 안테나는 X-대역에서 대역폭 10 %를 만족하며, 이중 슬롯 급전 마이크로스트립 패치 안테나와 편파 스위치의 사용으로 이중 편파 사용이 가능하다. 배열 구조는 $16\times16$의 삼각 배열 구조이고, 각 배열은 출력 40 dBm 이상의 TR(Transmit & Receive) 모듈로 구성된다. TR 모듈은 디지털 감쇄기와 위상 변위 기를 포함하고 있어서 임의의 빔 형성/빔 조향을 할 수 있으며, 전자적 빔 조향 범위는 방위각/고각 방향으로 각각 ${\pm}60^{\circ}$ 범위에서 가능하다. 또한 수신 구조는 부배열로 구성하여 수신 패턴은 각 채널로부터의 RF 빔 합성으로 얻어진다. 안테나의 성능 검증을 위해서 근접 전계 측정 시설에서 안테나 패턴을 측정하였으며, 패턴 측정 결과는 예측된 빔 패턴과 거의 일치하였고, 이로부터 제어에 의한 빔 조향/빔 형성이 가능함을 확인할 수 있었다.

차단기의 투입성능 평가를 위한 최적 합성투입시험설비 (Optimized Synthetic Making Test Facilities for Estimating the Making Performance of Circuit Breaker)

  • 서윤택;김맹현;송원표;고희석;박승재
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권6호
    • /
    • pp.284-292
    • /
    • 2005
  • Because all of the short-circuit testing laboratories have the limitation of test facilities, the synthetic making test methods have been used to estimate the short-circuit making performance of the ultra high-voltage circuit breaker as the alternative to direct test methods. So, KERI(Korea Eelctrotechnology Research institute) has completed the construction of the synthetic making test facilities using the low capacity step-up transformer method which fulfill the requirements specified in newly revised IEC 62271-100 Edition 1.1(2003) and have the testing capability up to 550kV, 63kA full-pole circuit breaker. The test facilities using the low capacity step-up transformer method presented in this paper are made up of the unit equipments such as HCS(High-speed Closing Switch), ITMC(Initial Transient Making Current) circuit and UP TR(low capacity step-up transformer) and have the operating range of 17.6$^{\circ}$ $\~$ 145.1$^{\circ}$ for testing the circuit breaker rated on up to 50kA and 43.1$^{\circ}$ $\~$ 119.6$^{\circ}$ for more than 50kA.