• 제목/요약/키워드: Polarus humeral nail

검색결과 5건 처리시간 0.018초

A Comparative Study on Internal Fixation Using Long Proximal Intramedullary Nail for the Treatment of Humeral Shaft Fracture according to Fracture Types

  • Choi, Chang-Hyuk;Jun, Chung-Mu;Kim, Jun-Young
    • Clinics in Shoulder and Elbow
    • /
    • 제22권2호
    • /
    • pp.87-92
    • /
    • 2019
  • Background: This study was conducted to compare the radiological and clinical outcomes of internal fixation using a Polarus humeral nail for treatment of a humeral shaft fracture according to fracture types. Methods: From 43 patients, 13 were excluded and 30 patients were included. The 30 patients were divided into 2 groups: 15 in group I (Orthopaedic Trauma Association/Arbeitsgemeinschaft $f{\ddot{u}}r$ Osteosynthesefragen classification type A and B) and 15 in group II (type C). The mean age was 63.1 years (range, 20-87 years), and mean follow-up period was 2.3 years (range, 1.0-6.1 years). The causes of injuries were as follows: 12, traffic accidents; 14, simple slips; 2, simple falls; 2, contusions after lower energy trauma. Radiological and clinical evaluations were performed. Results: Radiological union was confirmed by plain anteroposterior and lateral radiographs on average of 5.0 months in group I, and 8.4 months in group II, respectively. Differences between the two groups were statistically significant (p<0.01). The clinical union value was 1.6 in group I, and 2.0 months in group II, but these values did not differ significantly (p=0.441). The mean Korean shoulder scoring system scores were 89.7 and 90.6, which did not differ significantly (p=0.352). Conclusions: Intramedullary nailing using the Polarus humeral nail is considered to be a good treatment modality for all types of humeral shaft fractures. Additionally, the Polarus humeral nail can be an optimal choice for the treatment of complex type fractures such as segmental or comminuted humeral shaft fractures.

Comparing the Use of Single and Double Interlocking Distal Screws on a Polarus Intramedullary Nail for Humeral Shaft Fractures

  • Yang, Hee Seok;Kim, Jeong Woo;Kang, Hong Je;Park, Jung Hyun;Lee, Yong Chan;Kim, Kwang Mee
    • Clinics in Shoulder and Elbow
    • /
    • 제18권2호
    • /
    • pp.91-95
    • /
    • 2015
  • Background: Our aim was to make a comparative analysis of radiological and clinical outcomes of using either one or two interlocking distal screws on a Polarus intramedullary nail for the internal fixation of humeral shaft fractures. Methods: From January 2008 to March 2014, we enrolled 26 patients with humeral shaft fractures who were operated on using intramedullary nails. The patients were divided into 2 groups according to how many interlocking distal screws were used to lock the Polarus nail: in group 1, a single interlocking distal screw was used in 12 patients; and in group 2, double interlocking distal screws, in 14 patients. We compared the degree of recovery of the displaced fracture fragments between the two groups. To compare the nonunion and shoulder function, we assessed each patient's modified American Shoulder and Elbow Surgerns (ASES) score. Results: We found that 10 of 12 fractures achieved union in group 1, and 13 of 14 fractures, in group 2. We did not find a meaningful difference in the time to bone union between the two groups. The percentage of recovery of displaced fracture fragments until union was 66.9% for group 1 and 59.41% for group 2. At the final follow-up, we found that the scores for shoulder joint modified ASES was 78.7 for group 1 and 80.7 for group 2. Conclusions: Our results show that if locked appropriately, even a single screw on a Polarus nail can provide satisfactory radiological union and improved clinical outcome after intramedullary nailing of humeral shaft fractures.

한국인 Cadaver Test에 대한 상완골 골수정 개발에 관한 연구 (A Study on Development of Humeral Intramedullary Fixation Nail based on Korean Cadaver Tests)

  • 전창수;이재원;고철웅;오종건;우수현;이성재
    • 한국정밀공학회지
    • /
    • 제28권8호
    • /
    • pp.984-991
    • /
    • 2011
  • The aim of this study is to develop a humeral Intramedullary fixation nail (HIFN) suitable for Korean people. In this study, CT images were obtained from 72 Korean cadaveric humeral bones and 3D Korean humeral bone models were reconstructed based on the CT images to investigate anatomical characteristics. Major design parameters of HIFN were selected using the morphological measurement information of the Korean humeral bone models. Through finite element analysis and mechanical tests, the developed HIFN prototype was compared with the Polarus HIFN ($ACUMED^{(R)}$, USA), and it was found that the HIFN prototype showed similar and/or superior mechanical performance compared to the Polarus HIFN. Also, clinical validation for the HIFN prototype was carried out to check predictable troubles in surgical operations. Finally, optimal design modification was proposed to prevent the possible axillary nerve injury due to the locking screw system of the HIFN prototype.

Treatment of Proximal Humeral Fracture Using Polarus Nail and Philos Plate

  • Choi, Chang Hyuk;Sim, Jung Hyun;Lee, Sang Hwa;Lee, Joo Hwan;Nam, Jun Ho
    • Clinics in Shoulder and Elbow
    • /
    • 제17권3호
    • /
    • pp.120-126
    • /
    • 2014
  • Background: To compare the treatment of the proximal humerus fracture using a Polarus nail or Philos plate, we aimed to analyze the functional recovery and the factors affecting the selection between the two types of surgery. Methods: The study included 107 patients with proximal humerus fracture who underwent surgery at our institution. Of these patients, 67 underwent surgery with Polarus nails (G1) and 40 with Philos plates (G2). In G1, the cases of two- and three-part fractures were 60 and 7 cases, in G2, the cases of two-, three-, and four-part fractures were 28, 10, and 2 cases, respectively. The average age was 61 years old, and the average follow-up period was 32.5 months. We compared radiological results, the functional recovery retrospectively. Results: The radiological union time was 6.8 weeks and 8.7 weeks on average in G1 and G2 (p < 0.05). At the one-year follow-up period, these were visual analogue scale (VAS) 1.355, forward flexion (FF) 130.968, external rotation (ER) 50.161, internal rotation (IR) L2 in G1, and VAS 0.781, FF 135.806 ER 51.25, IR L1 in G2, respectively, showing no significant differences between the two groups (p > 0.05). Similar observations were made at the final follow-up. In terms of functional recovery, no significant differences were seen at the one-year or at the final follow-up period (p > 0.05). Conclusions: For the surgical treatment of proximal humeral fracture, the selection of the type of surgery is affected by the fracture pattern. However, both methods give satisfactory outcomes and do not show significant differences in the functional outcome after the surgery.

Clinical and Radiologic Results Comparing the Periarticular Proximal Humerus Locking Plate and Polarus Nail for Displaced Proximal Humerus Fractures

  • Min, Young-Kyoung;Lee, Seung-Jun;Gwak, Heui-Chul;Kang, Sang-Woo;Suh, Kuen-Tak
    • Clinics in Shoulder and Elbow
    • /
    • 제20권4호
    • /
    • pp.208-216
    • /
    • 2017
  • Background: This study compared the clinical and radiological outcomes of the single calcar screw plate and Polarus nail techniques for the treatment of the proximal humerus fractures. Methods: Seventy-two patients diagnosed with displaced proximal humerus fracture were enrolled for the study. Of these, 50 patients underwent the locking plate surgery with a single calcar screw (plate group), whereas 22 patients underwent the Polarus nail surgery (nail group). The plate group was further divided into plate 1 group (with medial support), and plate 2 group (without medial support). The radiological and functional results of both groups were compared to the nail group. Results: The ${\alpha}$ angle 1 year after surgery was significantly different between plate 1 and plate 2, and plate 2 and nail groups (p=0.041, p=0.043, respectively). The ratio that does not satisfy the reference value of ${\gamma}$ angle was 2.8% in plate 1, 7.1% in plate 2 and 22.7% in nail group (p=0.007); there was a significant difference between plate 1 and nail group, and plate 2 and nail group (p=0.014, p=0.033, respectively). Conclusions: No significant differences were observed in the clinical results between locking plate and Polarus nail. However, in the plate 2 group and nail group, the rate of failure to maintain reduction during the 1-year period after surgery was statistically and significantly higher than the plate 1 group (level of evidence: level IV, case series, treatment study).