• Title/Summary/Keyword: Polarograph

Search Result 13, Processing Time 0.018 seconds

Studies on Determination of Titanium from Ilmenite by Polarographic Method (Polarography 에 依한 Titanium 의 定量에 關한 硏究)

  • Kim, Hwang-Am;Kim, Chan-Kuk
    • Journal of the Korean Chemical Society
    • /
    • v.6 no.1
    • /
    • pp.10-13
    • /
    • 1962
  • Titanium in solution of EDTA (Ethylenediaminetetraacetic acid) yield well-defined, reversible polarographic waves. In this report, a polarographic method for rapid determination of titanium in the Korean ilmenite was proposed, This polarographic method is based on the measurement of polarogram in the supporting electrolyte of EDTA. As the pH is increased the wave become more irreversible the diffusion current are diminished, and the half wave potential become more negative. In spite of the complication arising from numerous titanium species, in 0.2 M of EDTA, pH 6.3, the titanium waves are reproducible and analytically useful. In this medium titanium ion give well-defined reduction wave, and the half wave potential were -0.61V vs S.C.E. at pH 6.3. At the same time, the wave had a linear relationship between the concentration of titanium ion and the wave height. The Korean ilmenites were analyzed by this method and satisfactory results were obtained.

  • PDF

The Cation Exchange Separation of Metal-Trien Mixed Complexes (금속-Trien 혼합착물의 양이온 교환수지상에서의 분리)

  • Yung-Kyu Park;Chul- Heui Lee;Mu-Kang Lee
    • Journal of the Korean Chemical Society
    • /
    • v.24 no.2
    • /
    • pp.129-138
    • /
    • 1980
  • The formation constants of the mixed-ligand complexes in the Cd(II), Cu(II) and Pb(II)-Trien-OH system were studied by polarograph. The formation constant $(log{\beta}_{ij})$ was determined at $25^{\circ}C$ in the ionic strength of 0.1. It was also confirmed that the mixed ligand complexes in this system were formed above pH 10.2, 10.5 and 9.0 for Cu(II), Cd(II) and Pb(II) by the calculation of the distribution for complexes at the various pH. Masking of Cd(II) by conversion to anionic EDTA-complexes has been used to separate Cu(II) from Cd(II) through passage of a combined Trien-EDTA solution on an cationic resin column. The optimal condition for the separation of Cu(II) from Cd(II) is confirmed at the pH range above 9.0, not only by considering the theoretical equation of the conditional-exchange-constant of metal on the cation exchange resin,but also by calculating the distribution of the mixed ligand complexes in the resin at the various pH with computer. By analyzing the synthetic sample of Cu(II) and Cd(II) with a EDTA masking at pH 9.5, it is found that the results of the experiment are satisfied with the theoretical value.

  • PDF

Analysis of Heavy Metals in $[^{201}Tl]$TICI Injection Using Polarography (폴라로그래피를 이용한 $[^{201}Tl]$염화탈륨 주사액의 중금속 분석)

  • Chun, Kwon-Soo;Suh, Yong-Sup;Yang, Seung-Dae;Ahn, Soon-Hyuk;Kim, Sang-Wook;Choi, Kang-Hyuk;Lee, Dong-Hoon;Lim, Sang-Moo;Yu, Kook-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.336-343
    • /
    • 2000
  • Purpose: Thallous-201 chloride produced at Korea Cancer Center Hospital(KCCH) is used in detecting cardiovascular disease and cancer. Thallium impurity can cause emesis, catharsis and nausea, so the presence of thallium and other metal impurities should be determined. According to USP and KP, their amounts must be less than 2 ppm in thallium and 5 ppm in total. In this study, the detection method of trace amounts of metal impurities in $[^{201}Tl]$TICI injection with polarography was optimized without environmental contamination. Materials and Methods: For the detection of metal impurities, Osteryoung Square Wave Stripping Voltammetry method was used in Bio-Analytical System (BAS) 50W polarograph. The voltammetry was composed of Dropping Mercury Electrode (DME) as a working electrode, Ag/AgCl as a reference electrode and Pt wire as a counter electrode. Square wave stripping method, which makes use of formation and deformation of amalgam, was adopted to determine the metal impurities, and pH 7 phosphate buffer was used as supporting electrolyte. Results: Tl, Cu and Pb in thallous-201 chloride solution were detected by scanning from 300 mV to -800 mV Calibration curves were made by using $TINO_3,\;CuSO_4\;and\;Pb(NO_3){_2}$ as standard solutions. Tl was confirmed at -450 mV peak potential and Cu at -50 mV Less than 2 ppm of Tl and Cu was detected and Pb was not detected in KCCH-produced thallous-201 chloride injection. Conclusion: Detection limit of thallium and copper is approximately 50 ppb with this method. As a result of this experiment, thallium and other metal impurities in thallous-201 chloride injection, produced at Korea Cancer Center Hospital, are in the regulation of USP and KP Polarograph could be applied for the determination of metal impurities in the quality control of radiopharmaceuticals conveniently without environmental contamination.

  • PDF