• Title/Summary/Keyword: Polarization analysis

Search Result 753, Processing Time 0.027 seconds

Characteristics Comparison of Anodic Films Formed on Mg-Al Alloys by Non-chromate Surface Treatment

  • Kim, Seong-Jong;Jang, Seok-Ki;Kim, Jeong-Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.300-308
    • /
    • 2004
  • The formation mechanism of anodic oxide films on Mg alloys when anodized in NaOH solution. was investigated by focusing on the effects of anodizing potential. Al content. and anodizing time. Pure Mg and Mg-Al alloys were anodized for 10 min at various potentials in NaOH solutions. $Mg(OH)_2$ was generated by an active dissolution reaction at the surface. and the product was affected by temperature. The intensity ratio of $Mg(OH)_2$ in the XRD analysis decreased with increasing applied potential. while that of MgO increased. The anti-corrosion properties of anodized specimens at each constant potential were better than those of non-anodized specimens. The specimen anodized at an applied potential of 3 V had the best anti-corrosion property. And the intensity ratio of $Mg_{17}Al_{12}$/Mg increased with aluminum content in Mg-Al alloys. During anodizing. the active dissolution reaction occurred preferentially in ${\beta}\;phase(Mg_{17}Al_{12})$ until about 4 mins. and then the current density increased radually until 7 mins. The dissolution reaction progressed in a phase(Mg) which not formed the intermetallic compound. which had a lower Al content. In the anodic polarization test of $0.017\;mol{\cdot}dm^-3$ NaCl and $0.1\;mol{\cdot}dm^-3\;Na_2SO_4$ at 298 K. the current density of Mg-15 mass% Al alloy anodized for 10 mins increased. since the anodic film that forms on the a phase is a non-compacted film. The anodic film on the phase for 30 mins was a compact film as compared with that for 10 mins.

Effect of Sintering Temperature on Dielectric Properties of 72 wt%(Al2O3):28 wt%(SiO2) Ceramics

  • Sahu, Manisha;Panigrahi, Basanta Kumar;Kim, Hoe Joon;Deepti, PL;Hajra, Sugato;Mohanta, Kalyani
    • Korean Journal of Materials Research
    • /
    • v.30 no.10
    • /
    • pp.495-501
    • /
    • 2020
  • The various sintered samples comprising of 72 wt% (Al2O3) : 28 wt% (SiO2) based ceramics were fabricated using a colloidal processing route. The phase analysis of the ceramics was performed using an X-ray diffractometer (XRD) at room temperature confirming the presence of Al2O5Si and Al5.33Si0.67O9.33. The surface morphology of the fracture surface of the different sintered samples having different sizes of grain distribution. The resistive and capacitive properties of the three different sintered samples at frequency sweep (1 kHz to 1 MHz). The contribution of grain and the non-Debye relaxation process is seen for various sintered samples in the Nyquist plot. The ferroelectric loop of the various sintered sample shows a slim shape giving rise to low remnant polarization. The excitation performance of the sample at a constant electric signal has been examined utilizing a designed electrical circuit. The above result suggests that the prepared lead-free ceramic can act as a base for designing of dielectric capacitors or resonators.

Evaluation of Corrosion and Cavitation Erosion Resistance of Sealed Aluminum Alloy after Anodizing Treatment in Seawater (양극산화 후 실링처리된 알루미늄 합금의 해수 내 내식성과 캐비테이션 침식 저항성 평가)

  • Park, Il-Cho;Lee, Jung-Hyung;Han, Min-Su;Kim, Seong-Jong
    • Journal of the Korean institute of surface engineering
    • /
    • v.51 no.2
    • /
    • pp.87-94
    • /
    • 2018
  • Various sealing techniques were applied to the anodized 5083 aluminum alloy for marine environment to reduce corrosion and cavitation erosion damage. Electrochemical experiments and cavitation erosion tests were conducted to evaluate the corrosion resistance and cavitation resistance of the anodic oxide film treated with sealing in natural seawater solution. Then, damaged surface morphology was analyzed by scanning electron microscope(SEM) and 3D microscope. As the results of the electrochemical experiments, it was observed that the surface damage of all the experimental conditions in the anodic polarization experiment was locally grown by the combination of crack and corrosion damage. In the Tafel analysis, the corrosion resistance of all sealing treatment conditions was improved compared to the anodizing. On the other hand, cavitation erosion tests showed that the anodizing and all the sealing treatment conditions generated local pit damage by cavitation erosion attack and grew to crater damage in the observation of damaged surface by SEM. Also, the weight loss and the surface damage depth measured with the experiment time presented that most of the sealing treatment conditions showed better cavitation erosion resistance than the anodizing, and they had an incubation period at the beginning of the experiment.

Surface Treatment Effect on Electrochemical characteristics of Al Alloy for ship

  • Lee, Seung-Jun;Kim, Seong-Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.149-149
    • /
    • 2017
  • Aluminum alloys have poor corrosion resistance compared to the pure aluminum due to the additive elements. Thus, anodizing technology artificially generating thick oxide films are widely applied nowadays in order to improve corrosion resistance. Anodizing is one of the surface modification techniques, which is commercially applicable to a large surface at a low price. However, most studies up to now have focused on its commercialization with hardly any research on the assessment and improvement of the physical characteristics of the anodized films. Therefore, this study aims to select the optimum temperature of sulfuric electrolyte to perform excellent corrosion resistance in the harsh marine environment through electrochemical experiment in the seawater upon generating porous films by variating the temperatures of sulfuric electrolyte. To fabricate uniform porous film of 5083 aluminum alloy, we conducted electro-polishing under the 25 V at $5^{\circ}C$ condition for three minutes using mixed solution of ethanol (95 %) and perchloric (70 %) acid with volume ratio of 4:1. Afterward, the first step surface modification was performed using sulfuric acid as an electrolyte where the electrolyte concentration was maintained at 10 vol.% by using a jacketed beaker. For anode, 5083 aluminum alloy with thickness of 5 mm and size of $2cm{\times}2cm$ was used, while platinum electrode was used for cathode. The distance between the two was maintained at 3 cm. Anodic polarization test was performed at scan rate of 2 mV/s up to +3.0 V vs open circuit potential in natural seawater. Surface morphology was compared using 3D analysis microscope to observe the damage behavior. As a result, the case of surface modification showed a significantly lower corrosion current density than that without modification, indicating excellent corrosion resistance.

  • PDF

Electrochemical characteristics of Ca, P, Sr, and Si Ions from PEO-treated Ti-6Al-4V Alloy Surface

  • Yu, Ji-Min;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.154-154
    • /
    • 2017
  • Ti-6Al-4V alloys are widely used as metal-lic biomaterials in dentistry and orthopedics due to its excellent biocompatibility and me-chanical properties. However, because of low biological activity, it is difficult to form bone growth directly on the surface of titanium implants. For this reason, surface treatment of plasma electrolytic oxidation(PEO) was used for dental implants. To enhance bioac-tivity on the surface, strontium(Sr) and sili-con(Si) ions can be added to PEO treated sur-face in the electrolyte containing these ions. The presence of Sr in the coating enhances osteoblast activity and differentiation, where-as it inhibits osteoclast production and prolif-eration. And Si has been found to be essen-tial for normal bone, cartilage growth, and development. In this study, electrochemical characteristics of Ca, P, Sr, and Si ions from PEO-treated Ti-6Al-4V alloy surface was re-searched using various experimental instruments. DC power is used and Ti-6Al-4V al-loy was subjected to a voltage of 280 V for 3 minutes in the electrolyte containing 5, 10, 20M% Sr ion and 5M% Si ion. The morphol-ogies of PEO-treated Ti-6Al-4V alloy by electrochemical anodization were examined by field-emission scanning electron micro-scopes (FE-SEM), energy dispersive x-ray spectroscopy (EDS), x-ray diffraction (XRD) and corrosion analysis using AC impedance and potentiodynamic polarization test in 0.9% NaCl solution at similar body tempera-ture using a potentiostat with a scan rate of 1.67mV/s and potential range from -1500mV to + 2000mV.

  • PDF

A Study on the Effect of Water Freezing on the Characteristics of Polymer Electrolyte Membrane Fuel Cells (물의 결빙이 고분자전해질 연료전지 성능에 미치는 영향 및 그 원인에 관한 연구)

  • Ko, Jae-Joon;Cho, Eun-Ae;Ha, Heung-Yong;Hong, Seong-Ahn;Lee, Kwan-Young;Lim, Tae-Won;Oh, In-Hwan
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.1
    • /
    • pp.36-40
    • /
    • 2003
  • Freezing of water in a polymer electrolyte membrane fuel cell (PEMFC) may cause severe problems in driving a fuel cell vehicle during the winter time. Characteristics of PEMFC which suffered low temperatures below zero degree was examined with the thermal cycles from 80 to $-10^{\circ}C$. With the thermal cycles, the cell performance was degraded due to the phase transformation and volume changes of water. Effects of freezing of water in PEMFC on the electrode structure and polarization resistance were examined by BET analysis, cyclic voltammetry, and AC impedance spectroscopy.

The Understanding of a Social Enterprise from the Christian Perspective: Focused on a Missional Church (기독교적 관점에서 본 사회적 기업 이해: 선교적 교회를 중심으로)

  • Bong, Won Young
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.1
    • /
    • pp.387-401
    • /
    • 2017
  • The purpose of this study was to show how to utilize social enterprise in the Christian aspect, especially from the view of the missional church, and to show how to help the community develop. Social enterprises appeared when the government and non-governmental organizations felt limitation in dealing with social issues such as rapid urbanization, unemployment, and economic polarization that occurred due to high industrialization. Because social enterprises differ from countries and there are various kinds of social enterprises even in each country, there is no common international definition; it is not easy to define it with one word. However, several common values could be found through this study. As social enterprises developed in the world, the missional church was introduced to a Christian world around the same time. Through analysis of social enterprises and the missional church, A researcher found five common elements between them: time of first appearance, background of appearance, business value, focus of activities, and base elements. In addition, I discussed applicable suggestions that the missional church cooperated with social enterprises to make a healthier community.

Dielectric Thin Film Mirror Embedded Optical Fiber Couplers (유전체 박막 거울 내장형 광섬유 결합기)

  • 신종덕
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.420-427
    • /
    • 1993
  • Dielectric thin film mirrors are embedded in multimode and single-mode fibers by a fusion splicing technique. The fibers with $45{\circ}$ angled embedded mirrors serve as ultra-compact directional couplers with low excess optical loss of 0.2 dB for multimode and 0.5 dB for single mode at 1.3 ${\mu}m$ and excellent mechanical properties. The reflectance is wavelength dependent and strongly polarization depencient. Far-field scans of the reflected output power measured with a white-light source show a pattern which is almost circularly symmetric with aspect ratio of 1.09 at 5% of the peak power. The splitting ratio in a multimode coupler measured with a diode laser source is much less dependent on input coupling conditions than in conventional fused biconical-taper couplers, indicating that these couplers are less susceptible to modal noise occuring in optical fiber communication systems. Spectral properties of multilayer internal mirrors normal to the fiber axis have been investigated experimentally, and a matrix analysis has been used to explain the results.

  • PDF

Effect of Anodizing Current Density on Anti-Corrosion Characteristics for Al2O3 Oxide Film (Al2O3 산화 피막의 내식성에 미치는 양극산화 전류밀도의 영향)

  • Lee, Seung-Jun;Jang, Seok-Gi;Kim, Seong-Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.153-153
    • /
    • 2016
  • Aluminum alloys have poor corrosion resistance compared to the pure aluminum due to the additive elements. Thus, anodizing technology artificially generating thick oxide films are widely applied nowadays in order to improve corrosion resistance. Anodizing is one of the surface modification techniques, which is commercially applicable to a large surface at a low price. However, most studies up to now have focused on its commercialization with hardly any research on the assessment and improvement of the physical characteristics of the anodized films. Therefore, this study aims to select the optimum temperature of sulfuric electrolyte to perform excellent corrosion resistance in the harsh marine environment through electrochemical experiment in the sea water upon generating porous films by variating the temperatures of sulfuric electrolyte. To fabricate uniform porous film of 5083 aluminum alloy, we conducted electro-polishing under the 25 V at $5^{\circ}C$ condition for three minutes using mixed solution of ethanol (95 %) and perchloric (70 %) acid with volume ratio of 4:1. Afterward, the first step surface modification was performed using sulfuric acid as an electrolyte where the electrolyte concentration was maintained at 10 vol.% by using a jacketed beaker. For anode, 5083 aluminum alloy with thickness of 5 mm and size of $2cm{\times}2cm$ was used, while platinum electrode was used for cathode. The distance between the two was maintained at 3 cm. Afterward, the irregular oxide film that was created in the first step surface modification was removed. For the second step surface modification process (identical to the step 1), etching was performed using mixture of chromic acid (1.8 wt.%) and phosphoric acid (6 wt.%) at $60^{\circ}C$ temperature for 30 minutes. Anodic polarization test was performed at scan rate of 2 mV/s up to +3.0 V vs open circuit potential in natural seawater. Surface morphology was compared using 3D analysis microscope to observe the damage behavior. As a result, the case of surface modification presented a significantly lower corrosion current density than that without modification, indicating excellent corrosion resistance.

  • PDF

Pharmacokinetics of Two Cyclosporine Formulations Using FPIA and HPLC Assay in Volunterrs

  • Kwon, Kwang-Il;Kim, Moo-Heon;Park, Jong-Woo;Lee, Chang-Hyun
    • Archives of Pharmacal Research
    • /
    • v.18 no.6
    • /
    • pp.385-390
    • /
    • 1995
  • The analytical methods for the analysis of cyclosporine (CsA), a fluorescence polarization immunoassay (FPIA) and HPLC method, were compared in a pharmacokinetic study of two CsA soft capsule formultaions ($Sandimmun^{\circledR}$; Sandoz, $Implanta^{\circledR}$; Hanmi). Sixteen healthy volunteers completed the study and each subjected single doses ($4{\tiems}100$ mg) of the test and the reference formulations in a two-way crossover design with a one-week drug-free interval between doses. Following each administration, whole blood concentrations of CsA were monitored over a period of 24 hour by both FPIA and HPLC methods. Blood concentrations nad pharmacokinetic parameters determined by either analytical method showed large intersubject variation, with the FPIA data showing relatively higher magnitude of intersubjecte variation than the HPLC data. The blood concentrations determined by FPIA were 1.1-1.3 times higher than those determined by HPLC. There were strong and significant correlations between the two methods (r>0.83 : p<0.0001). Intersubuject variation for the $AUC_{inf}{\;}and{\;}AUC_{24hr}$ of the test formulation was slightly reduced without statistical significance (paried -t test : p>0.05 $t_{max}$ was earlier nad $C_{max}$ was slightly lower for the test formulation, $AUC_{24h}, {\;}C_{max}, {\;}T_{max}$ and MRT determined separately from the data obtained by the two methods for the two formulations were examined by analyses of variance (ANOVA) for the bioequivalency evaluation. Results of ANOVA and confidence limits of terst/reference ratios of $AUC_{24th}$, $C_{max}$, $t_{max}$ and MRT, and statistical tests indicated the bioequivalence of the two formulations (i.e., test/reference ratio was within $100{\times}20%$) except for $C_{max}$ and $t_{max}$. The mean of tmax also showed 11.1% and 9.3% differences but the detection limit were 29.2% and 29.6% as determined by FPIA and HPLC resepctively. This experiments suggest that the data yielded for the two formulations demonstrated that they were bioequivalent.

  • PDF