• 제목/요약/키워드: Polarization Control

검색결과 222건 처리시간 0.028초

1N 염산 용액에서 Fe-Cr-Ni-W 합금의 양분극 거동에 관한 연구 (The Anodicc PolarizationBehavior of Fe-Cr-Ni-W alloy in 1N HCI Solution)

  • 윤재돈;강성군
    • 한국표면공학회지
    • /
    • 제21권4호
    • /
    • pp.176-182
    • /
    • 1988
  • Effects of Cr, Ni and W on the anodic polarization behavior were investigated for Fe-Cr-Ni-W alloys in deaerated 1N HCI solution. Surface films formed on the polarization were analysed using AES, SEM and EDAX. A higerconcentration of tungten was found in the surface oxide film compared to the matrix. It played an importanet role on incresing the stability of the passive film. The presence of an adequate amount of Cr was essential to increase the pitting resistance of the alloys in acid chloride media. Under 12 wt%cr,alloys containing 6wt%W did not exhidit any passivity at all. The main role of Ni was to control the microstructure rather than to modify the corrosion resistance. In 23 cr-14Ni-^W alloy, the duplex microstructure of ferrite($\delta$-phase) in an austenic matrix was developed. The reson why proferred pitting appeared in austenite and ferrite/austenite interface was that ferrite had more amount of Cr and W than austenite.

  • PDF

Measurement of membrane fluidity of rockfish (Sebastes schlegeli) phagocytes during the respiratory burst using fluorescence polarization assay

  • Jung, Jae-Hyuck;Kwon, Se-Ryun;Lee, Eun-Hye;Kim, Sung-Mi;Kim, Ki-Hong
    • 한국어병학회지
    • /
    • 제16권2호
    • /
    • pp.131-134
    • /
    • 2003
  • The change of membrane fluidity in rockfish (Sebastes schlegeli) phagocytes during respiratory burst was investigated. Fluorescence polarization (FP) was used as a measure of membrane fluidity, and 1-(4-trimethylaminophenyl)-6-phenyl-1 .3 ,5-hexatriene (TMA.-DPH) was used us a fluorescent probe. The significantly higher FP values in phagocytes stimulated With zymosan or phurbol myristate acetate (PMA) than unstimulated control phagocytes suggests that membrane fluidity of phagocytcs is decreased during the respiratory burst. The faster decrease of FP value in PMA stimulated phagocytes than in zymosan sumulated phagocytes may be due to bypass of the receptor-mediated stages of functional modulation. which is needed in zymosan stimulated phagocytes.

농도분극현상을 이용한 담수화 과정에서의 나노채널 개수 및 운전조건 영향에 대한 실험 적 연구 (Experimental study on effect of nanochannel numbers and working conditions for concentration polarization based desalination process)

  • 이용남;김대중
    • 한국가시화정보학회지
    • /
    • 제13권2호
    • /
    • pp.16-21
    • /
    • 2015
  • Concentration polarization(CP) phenomena show great potential on desalination technology. As we can control the dimension of silicon based nanochannel system, it can be used to model ion exchange membrane. In this study, to investigate the effect of nanochannel number and working conditions on the CP based desalination process, nanochannel based microfluidic system is fabricated. First, we optimized nanochannel number and working conditions to conduct visualization study on CP based desalination process. Second, we visualized the desalination process with fluorescent dye in the desalination chip. We also visualized that the particles also can be removed by the CP based desalination process.

편광제어에 의한 파장가변 고리형 광섬유레이저에서의 파장천이특성 (The Chracteristics of Wavelength Shift in Fiber Ring Laser Tuned by Polarization Control)

  • 김익상
    • 한국통신학회논문지
    • /
    • 제25권9B호
    • /
    • pp.1534-1541
    • /
    • 2000
  • 광섬유고리에 편광제어를 통해 여러 광경로들에 대해서 손실을 조정함으로써 손실이 작은 광경로에서 발진하게 함으로써 발진 파장을 가변시킬 수 있는 편광제어 파장가변 고리형 광섬유레이저를 구현하였다. 1.5mm의 공극을 가진 내부공진편광기를 사용하여 1nm의 종모드간격으로 발진을 일으킬 수 있었고 편광제어기 및 내부공진편광기를 조절해서 1540!1560 nm의 파장가변을 시킬 수 있었다. 또한 실험적으로 나타난 발진특성을 광경로와 복굴절 손실의 개념을 사용하여 발진출력의 파장천이특성을 분석하였다.

  • PDF

Key Technologies of Supercapacitor Energy Storage System of IP Transmitter

  • Zeng, Zhihui;Wang, Xiaowei;Wei, Yanfang;Hu, Zhiguo;Yu, Yangxiao;Zhang, Zhigang
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.316-331
    • /
    • 2019
  • A practical application of a supercapacitor energy storage system in a polarization instrument is proposed on the basis of the energy storage requirements of an induced polarization (IP) transmitter for geophysical exploration. We focused on the energy storage system of a supercapacitor, the topology of the power converter, and the system control strategy as key technologies, and we performed theoretical research and experimental tests on the system and developed an experimental platform. The experiments validated the theoretical research on the key technologies of the supercapacitor energy storage system and demonstrated the effectiveness of the innovation. Results showed that the storage system is efficient and satisfies the energy storage needs of the IP transmitter.

Corrosion Evaluation of Epoxy-Coated Bars in Chloride Contaminated Concrete Using Linear Polarization Tests

  • Choi, Oan-Chul;Jung, Si-Young;Park, Young-Soo
    • International Journal of Concrete Structures and Materials
    • /
    • 제18권1E호
    • /
    • pp.3-9
    • /
    • 2006
  • Five slab specimens with predefined cracks are examined to evaluate the corrosion behavior of epoxy-coated bars in chloride contaminated concrete, using linear polarization method. The test specimens were subjected to alternating weekly cycles of ponding in a salt solution and drying for 48 weeks. Test results show that the current density of the specimen of normal steel bars becomes 0.715 ${\mu}A/cm^2$ indicating that the steel bars are in moderate or high corrosion condition. However, the corrosion rates of the specimens with damaged epoxy-coated bars are significantly below 0.1 ${\mu}A/cm^2$ and the bars appears to be in passive condition. The damaged epoxy-coated bars with a corrosion inhibitor of calcium nitrite showed a corrosion rate of 0.110 ${\mu}m/year$ or 56 percents of the corrosion rate of damaged epoxy-coated specimen without such an inhibitor, 0.195 ${\mu}m/year$. However, the corrosion rates of specimens containing the other two corrosion inhibitors, a combination of amines and esters or mixtures of organic alkenyl dicarboxyl acid salts are quite equivalent to the control specimen. The research technique of linear polarization resistance method has proven itself to be useful in measuring corrosion rates of reinforcement in concrete.

평판형 방사소자를 이용한 원형편파용 혼 안테나 설계 (Conformal Horn Antenna for Circular Polarization using Planar-type Radiator)

  • 정영배
    • 전기전자학회논문지
    • /
    • 제16권3호
    • /
    • pp.173-176
    • /
    • 2012
  • 본 논문에서는 평판형 방사소자를 이용한 새로운 원형편파용 혼 안테나를 제안한다. 본 안테나는 평판형 마이크로스트립 안테나와 구형 혼으로 구성되며, 혼 내부에 삽입되는 마이크로스트립 안테나는 혼에 전력신호를 여기하는 급전부이자 편파기로서 동작한다. 또한, 마이크로스트립 안테나는 고이득, 높은 고립도 특성과 함께 광대역을 구현하기 위하여 금속 스페이서를 삽입한 적층형 구조로 설계되었다. 제안된 구조를 통하여, 혼 안테나는 급전부와 편파기와 같은 부가적인 구조를 별도로 설계하지 않음으로써 안테나의 소형화를 도모할 수 있다. 제안된 안테나는 8.6dBi의 이득과 4.8%의 3-dB 축비 대역폭을 가지며, 특히, 높은 대역에서 원형편파로 동작되는 이동통신 및 위성통신 분야의 다양한 안테나 시스템에 적용될 수 있다.

Real Time Measurement of Protease Activity of Live Uronema marinum (Ciliata: Scuticociliatida) by Fluorescence Polarization Assay

  • Lee Eun Hye;Kwon Se Ryun;Kim Chun Soo;Chung Joon Ki;Lee Hyung Ho;Kim Ki Hong
    • Fisheries and Aquatic Sciences
    • /
    • 제5권4호
    • /
    • pp.311-313
    • /
    • 2002
  • Proteolytic activity of live Uronema manum was analyzed by fluorescence polarization (FP) technique. Protease activity was measured by a decrease in FP value using fluorescein isothiocynate (FITC)-casein as a protein substrate. The results demonstrated an inverse linear relationship between fluorescence polarization (FP) values and live ciliate concentration over the range $1\times10^4\;to\;2\times10^5$ cells/well. However, the FP values of $10-10^3$ live parasites were not different significantly from that of control. Time-dependent decrease in FP value was shown in the wells containing live U. marinum. In the present study, FP assay had the benefit to provide measurements of substrate hydrolysis by live parasites in real-time, and did not require separations, precipitations, or transfers of reaction mixture.

편광상이 고리 형태의 다파장 스위칭 가능한 1차 광섬유 유연 필터의 스펙트럼 특성 (Spectral Characteristics of Multiwavelength-Switchable First-Order Fiber Flexible Filter based on Polarization-Diversity Loop)

  • 박경수;김영호;이용욱
    • 조명전기설비학회논문지
    • /
    • 제28권8호
    • /
    • pp.6-13
    • /
    • 2014
  • In this paper, a multiwavelength-switchable first-order fiber flexible filter is newly proposed, which is based on a polarization-diversity loop. The proposed filter consists of a polarization beam splitter, three half-wave plates(HWPs), and two high birefringent fibers(HBFs). The proposed filter has a good flexibility in adjusting relative angular difference between the principal axes of two HBFs by inserting an HWP between two HBFs. The first-order flat-top or narrow band transmission spectra and the zeroth-order transmission spectra, which had a channel spacing of ~0.8nm, could be obtained by controlling the three HWPs, and, in particular, each of them could also be interleaved. In addition, zeroth-order transmission spectra with a channel spacing of ~0.8nm could be flexibly converted into those with a channel spacing of ~0.4nm through the control of three HWPs, and also be interleaved. The transmission characteristics of the proposed filter was theoretically analyzed and experimentally verified.

Ti:LiNbO3 집적광학형 파장가변 편광모드 조절기에 관한 연구 (A Study on Ti:LiNbO3 Integrated Optical Wavelength Tunable Polarization Mode Controllers)

  • 문제영;정홍식
    • 한국광학회지
    • /
    • 제16권4호
    • /
    • pp.376-383
    • /
    • 2005
  • [ $Ti:LiNbO_3$ ] 채널 광도파로와 전기광학효과를 이용하여 설계된 집적광학 파장가변 편광모드 조절기를 설계 및 제작하고, 동작특성을 측정하였다. 소자는 $TE↔TM$ 모드변환기와 TE./TM 위상변환기로 구성되었으며, Jones 매트릭스를 이용하여 각각의 전달 매트릭스를 유도하였다. 위상변환기에 의한 파장 변환율을 전산 모사하였으며, 제작된 소자의 동작 특성들을 확인하였다. 폴래리미터와 Poincare 구 좌표계를 이용하여 편광 조절기의 동작 상태를 체계적으로 측정하였다.