• Title/Summary/Keyword: Point-position control

Search Result 603, Processing Time 0.03 seconds

Effects of Change in Patient Position on Radiation Dose to Surrounding Organs During Chest Lateral Radiography with Auto Exposure Control Mode (자동노출제어장치를 적용한 흉부 측면 방사선검사 시 환자 위치 변화가 주변 장기의 선량에 미치는 영향)

  • Seung-Uk Kim;Cheong-Hwan Lim;Young-Cheol Joo;Sin-Young Yu
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.903-909
    • /
    • 2023
  • The purpose of this study is to compare and analyze the effect of changes in the patient's central position on the exposure dose and image quality of surrounding organs during a chest lateral examination using an Auto Exposure Control(AEC). The experiment was conducted on a human body phantom. A needle was attached to the lower part of the center of the coronal plane of the phantom, and a lead ruler was attached to the lower part of the detector so that the 50 cm point was located at the lower center of the AEC ion chamber. The exposure conditions were 125 kVp, 320 mA, the distance between the source and the image receptor was 180 cm, and the exposure field size was 14 × 17 inches. Only one AEC ion chamber was used at the bottom center, and the density was set to '0' and sensitivity to 'Middle', and the central X-ray was incident vertically toward the 6th thoracic vertebra. With AEC mode applied, the 50 cm point of the needle and lead ruler were aligned and the phantom was moved 5 cm toward the stomach (F5) and 5 cm toward the back (B5), and the dose factor was analyzed by measuring ESD. The ESD of the thyroid gland according to the change in patient center position was 232.60±2.20 μGy for Center, 231.22±1.53 μGy for F5, and 184.37±1.19 μGy for B5, and the ESD of the breast was 288.54±3.03 μGy for Center, F5 was 260.97±1.93 μGy, B5 was 229.80±1.62 μGy, and the ESD of the center of the lung was 337.02±3.25 μGy for Center, F5 was 336.09±2.29 μGy, and B5 was 261.76±1.68 μGy. As a result of comparing the average values of dose factors between each group, the difference in average values was statistically significant (p<0.01), and each group appeared to be independent. As a result of the study, there was no significant difference in the dose to the thyroid, breast, and center of the lung according to the change in the patient's central position, except for the breast (10%) when the patient moved forward about 5 cm. However, movement of about 5 cm posteriorly resulted in an average dose reduction of 23.7%. Additionally, when the patient's central position was moved to the rear, image quality deteriorated.

Location of mental foramen by lateral cepalometric radiography (측방 두부규격방사선사진을 이용한 이공의 위치)

  • Lee, Seung-Hun;Kim, Dong-Yeol;Jung, So-Yun
    • Journal of Korean society of Dental Hygiene
    • /
    • v.10 no.4
    • /
    • pp.655-661
    • /
    • 2010
  • Objectives : This study is aimed to prevent the damage to the inferior alveolar nerve during the orthognathic surgery. Methods : The control group consist of 50 patients with class I occlusion. The experimental group consist of 50 patients with class III malocclusion. The cepalometric radiography was used to evaluate the position of the mental foramina. Results : In the first, mental foramen position of class III was more inferior 0.85 mm in the distance between base of mandible and mental foramen. But the distance between occlusal plan and mental foramen had not statistically significant. Secondly, mental foramen location of Mandibular Prognathism was more anterior 0.91 mm in the distance between coronal plane of mandible included pogonion point and mental foramen. Also, the distance of occlusal-coronal plane of mandible included central incisor and mental foramen had statistically significant. The mental foramen location of class III was more anterior 4.81 mm than class I patients. Conclusions : The result of this study could help the clinicians to apprehend fundamental data with various facial skeletal types for any related researches about the location of the mental foramina for other purposes.

Computer Integrated Surgical Robot System for Spinal Fusion

  • Kim Sungmin;Chung Goo Bong;Oh Se Min;Yi Byung-Ju;Kim Whee Kuk;Park Jong Il;Kim Young Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.5
    • /
    • pp.265-270
    • /
    • 2005
  • A new Computer Integrated Surgical Robot system is composed of a surgical robot, a surgical planning system, and an optical tracking system. The system plays roles of an assisting surgeon and taking the place of surgeons for inserting a pedicle screw in spinal fusion. Compared to pure surgical navigation systems as well as conventional methods for spinal fusion, it is able to achieve better accuracy through compensating for the portending movement of the surgical target area. Furthermore, the robot can position and guide needles, drills, and other surgical instruments or conducts drilling/screwing directly. Preoperatively, the desired entry point, orientation, and depth of surgical tools for pedicle screw insertion are determined by the surgical planning system based on CT/MR images. Intra-operatively, position information on surgical instruments and targeted surgical areas is obtained from the navigation system. Two exemplary experiments employing the developed image-guided surgical robot system are conducted.

Development of Auto-Tuning Geomagnetic Compass (자동 자기 왜곡보정 방위센서 개발)

  • Kim, Sang-Cheol;Lee, Yong-Beom;Han, Kil-Su;Im, Dong-Hyeok;Choi, Hong-Gi;Park, Woo-Pung;Lee, Woon-Yong
    • Journal of Biosystems Engineering
    • /
    • v.33 no.1
    • /
    • pp.58-62
    • /
    • 2008
  • The need for position information in agriculture is gradually increasing for precise control farm vehicle and effective manage farm land. Though geomagnetic sensor has a lot of merits in estimating heading angle of vehicle because of low costs and sensing ability of magnetic north, it is easy that sensor outputs are distorted in electro magnetic field environment. This study was conducted to develop geomagnetic compass which could be available in measuring relative position from reference point correcting output distorted by external electro magnetic field in a small scale field. Magnetic inducing sensor (PNI's Vector2X) which wound enamel coated copper coil on ferrite core in order to measure and correct earth magnetic field. Magnetic azimuth was corrected using the algorithm which estimated amount of magnetic distortion from the difference between each outputs of magnetic sensors that located on the cross shaped base. Developed auto-tuning magnetic sensor was showed less then 5% as bearing accuracy in the strong magnetic field.

A Precise Heave Determination System Using Time-Differenced GNSS Carrier Phase Measurements

  • Cho, MinGyou;Kang, In-Suk;Park, Chansik
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.6 no.4
    • /
    • pp.149-157
    • /
    • 2017
  • In this study, a system that precisely determines the heave of ship hull was designed using time-differenced GNSS carrier phase measurement, and the performance was examined. First, a technique that calculates precise position relative to the original position based on TDCP measurement for point positioning using only one receiver was implemented. Second, to eliminate the long-cycle drift error occurring due to the measurement error that has not been completely removed by time-differencing, an easily implementable high-pass filter was designed, and the optimum coefficient was determined through an experiment. In a static experiment based on the precise heave measurement system implemented using low-cost commercial GNSS receiver and PC, the heave could be measured with a precision of 2 cm standard deviation. In addition, in a dynamic experiment where it moved up and down with an amplitude of 48 cm and a cycle of 20 seconds, precise heave without drift error could be determined. The system proposed in this study can be easily used for many applications, such as the altitude correction of fish detection radar.

Design of Optimized Fuzzy Controller for Rotary Inverted Pendulum System Using Differential Evolution (차분진화 알고리즘을 이용한 회전형 역 진자 시스템의 최적 퍼지 제어기 설계)

  • Kim, Hyun-Ki;Lee, Dong-Jin;Oh, Sung-Kwun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.2
    • /
    • pp.407-415
    • /
    • 2011
  • In this study, we propose the design of optimized fuzzy controller for the rotary inverted pendulum system by using differential evolution algorithm. The structure of the differential evolution algorithm has a simple structure and its convergence to optimal values is superb in comparison to other optimization algorithms. Also the differential evolution algorithm is easier to use because it have simpler mathematical operators and have much less computational time when compared with other optimization algorithms. The rotary inverted pendulum system is nonlinear and has a unstable motion. The objective is to control the position of the rotating arm and to make the pendulum to maintain the unstable equilibrium point at vertical position. The output performance of the proposed fuzzy controller is considered from the viewpoint of performance criteria such as overshoot, steady-state error, and settling time through simulation and practical experiment. From the result of both simulation and practical experiment, we evaluate and analyze the performance of the proposed optimal fuzzy controller from the comparison between PGAs and differential evolution algorithms. Also we show the superiority of the output performance as well as the characteristic of differential evolution algorithm.

A Development of Micro-Positioning Grinding Table using Piezoelectric Voltage Feedback (압전전압 궤환에 의한 미세구동 연삭테이블의 개발)

  • Nam, Soo-Ryong;Kim, Jeong-Du
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.2
    • /
    • pp.48-58
    • /
    • 1995
  • A micro positioning system using piezoelectric actuators have very wide application region such as ultra-precision machine tool, optical device, measurement systen. In order ro keep a high precision displacement resolution, they use a position sensor and feedback the error. From the practical point of view, a high-resolution displacement sensor system are very expensive and difficult to guarantee such sensitive sensors work properly in the hard opera- tion environment of industry. In this study, a micro-positioning grinding table which does not require position sensor but uses piezoelectric voltage feedback, has been developed. It is driven by hystersis-considering reference input voltage which calculated from computer and then uses actuator/sensor characteristics of piezoelectric materials. From the result of experiments we proved a fast and stable response of micro-positioning system and suggested efficient technique to control the piezoelectric actuator. And through grinding experiments, it is revealed that a characteristics of ground surfaces transient to plastic deformation as extremely small depth of grinding.

  • PDF

RHT-Based Ellipse Detection for Estimating the Position of Parts on an Automobile Cowl Cross Bar Assembly (RHT 기법을 이용한 카울크로스바의 조립위치 결정에 관한 연구)

  • Shin, Ik-Sang;Kang, Dong-Hyeon;Hong, Young-Gi;Min, Young-Bong
    • Journal of Biosystems Engineering
    • /
    • v.36 no.5
    • /
    • pp.377-383
    • /
    • 2011
  • This study proposed the new method of discerning the assembled parts and presuming the position of central point in a Cowl Cross Bar (CCB) using a Charge-Couple Device (CCD) camera attached to a robot in the auto assembly line. Three control points of an ellipse were decided by three reference points, which were equally distanced. The radii of these reference points were determined by the size of the object, and the repeated presumption secured the precise determination. The comparison of the central point of ellipse presumed by Randomized Hough Transform (RHT) with the part information stored in a database was used for determining the faulty part in an assembly. The method proposed in this study was applied for the real-time inspection of elliptical parts, such as bolt, nut hole and so on, connected to a CCB using a CCD camera. The findings of this study showed that the precise decision on whether the parts are inferior or not can be made irrespective of the lighting condition of industrial site and the noises of the surface of the part. In addition, the defect decision on the individual elliptic parts assembled in a CCB showed more than 98% accuracy within a 500-millisecond period at most.

Effects of Myofascial Release and Posture Correction Exercise on the Neck Movement and the Quality of Sleep in Patients with Chronic Tension-Type Headaches

  • Cho, Sunghak
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.10 no.4
    • /
    • pp.1897-1902
    • /
    • 2019
  • Background: Tension-type headaches, which make up the highest proportion of headaches, are prone to develop into chronic tension-type headaches (CTTH). The characteristic of CTTH in patients is that the active myofascial trigger point (ATrP) which causes pain in the muscles of the back of the head is increased, compared to the normal headache and moves the head position forward. Objective: The aim of this study was to investigate the effects of myofascial release (MFR) and posture correction in effectively improving neck function and sleep quality in the symptoms of CTTH patients. Design: Observer-blind study Methods: To reduce ATrP, MFR was applied and exercise was also applied to correct posture. The subjects of this study were 48 individuals randomly divided into three groups; The MFR group using the MFR technique; The MFR with exercise group subject to both the MFR technique and forward head position correction exercises (MFREx), and the control group. MFR and MFREx groups were given the relevant interventions twice a week for four consecutive weeks, and went through the number ATrPs, range of motion (ROM) of neck, Neck Disability Index (NDI) and the Pittsburgh Sleep Quality Index (PSQI) before and after the intervention. A physical therapist, who was fully familiar with the measuring methods of the equipment, was the measurer and not aware of the target's condition was blinded to take measurements only before and after intervention. Results: There was a significant improvement in the ATrP, Neck ROM, NDI and PSQI in the group of patients to whom the MFR technique and MFREx were applied. MFREx was more effective in increasing neck mobility. Conclusions: According to this study, the application of MFR is effective in improving neck movement and sleep quality in chronic tension headache patients.

The Improvement of Electrical Point Machine Wiring Set (선로전환기(NS)의 배선세트 개선)

  • Jeong, Rag-Gyo;Park, Gun-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.351-358
    • /
    • 2016
  • An Electrical Point Machine (NS:New-type Switch), which is equipped and operated at railways in Korea, has been used since the 1960s after being imported from Japan. On the other hand, although the mechanical configuration has improved the position motor control circuit, the electrical connection has not been improved, so NS may have a problem, such as the interlocking system of automatic train operation. In addition, NS is the most vulnerable part in the railway system and a huge train accident may occur due to minor defects. The existing NS wiring set of the circuit controller should be checked only if fixed. Therefore, an excessive inspection time only by a Railroad Signal expert is required. In this paper, the improvement of electrical connection in a NS wiring set, such as the position motor control circuit, was developed and the prototype was installed at Seoul Metro in the distance to go section. The results can be used to help make appropriate adjustments. The improvement of the NS wiring set enhance the maintenance efficiency, passenger service and the stability of the signal system as well as reducing the maintenance cost.