Purpose: This study was to examine the reliability and validity of the Korean version of the Cornell Assessment of Pediatric Delirium (CAPD). Methods: For testing the reliability of the Korean version of the CAPD, this study calculated the internal consistency (Cronbach's α) and the Interrater Correlation Coefficient (ICC) by comparing the independent assessment results of three nurses in Pediatric Intensive Care Unit (PICU). For testing the validity of the Korean version of the CAPD, the assessment result of the Korean version of the CAPD compared with that of the Diagnostic and Statistical Manual of Mental Disorders V (DSM-V). Receiver Operating Characteristics (ROC) analysis was used for measuring sensitivity and specificity. Results: Overall interrater reliability of the Korean version of the CAPD, ICC was .98 (95% CI .96~.99). Cronbach's α was .91 for eight items. The concordance between the Korean version of the CAPD and psychiatrist's diagnosis was 90.0%. When the Korean version of the CAPD has the cut point of 9, sensitivity was 93.8%, and specificity was 75.0%. The area under the curve indicated by the ROC analysis was .88. Conclusion: The Korean version of the CAPD showed good reliability and validity. This tool will be useful for pediatric delirium screening and management in Korean PICU.
Background: The coronavirus disease 2019 pandemic has been challenging the healthcare service, i.e., the vitalization of the point of care accompanying self-testing in vitro diagnostic medical devices (IVDs). This study aims to suggest priority criteria to classify self-testing IVDs using the analytic hierarchy process technique. Methods: Two dimensions of the characteristics embedded in the IVDs and the diseases to be diagnosed with self-testing IVDs were parallelly considered and independently investigated. In addition, three expert panels consisting of laboratory medical doctors (n=11), clinicians (n=10), and citizens (n=11) who have an interest in the selection of self-testing IVDs were asked to answer to questionnaires. Priorities were derived and compared among each expert panel. Results: First of all, ease of specimen collection (0.241), urgency of the situation (0.224), and simplicity of device operation (0.214) were found to be the most important criteria in light of the functional characteristics of self-testing IVDs. Medical doctors valued the ease of specimen collection, but the citizen's panel valued self-management of the disease more. Second, considering the characteristics of the diseases, the priority criteria were shown in the order of prevalence of diseases (0.421), fatality of disease (0.378), and disease with stigma (0.201). Third, medical doctors responded that self-testing IVDs were more than twice as suitable for non-communicable diseases as compared to communicable diseases (0.688 vs. 0.312), but the citizen's group responded that self-testing IVDs were slightly more suitable for infectious diseases (0.511 vs. 0.489). Conclusion: Our findings suggested that self-testing IVDs could be primarily classified as the items for diagnosis of non-communicable diseases for the purpose of self-management with easy specimen collection and simple operation of devices, taking into account the urgency of the situation as well as prevalence and fatality of the disease.
Purpose: Maximizing human comfort in design of medical environments depends immensely on specialized architects particularly critical care design; the study proposes Evidence-Based Design as an apparent analog to Evidence-Based Medicine. Healthcare facility designs are substantially based on the findings of study in an effort to design environments that augment care by improving patient safety and being therapeutic. On SPSS (Statistical Package for Social Science) t-test is applied to simulate two independent variables of PDR (Pre Design-Research) and POE (Post- Occupancy Evaluation). PDR is conducted on relatively new hospital Hallym University Dongtan Sacred Heart Hospital to analyse visibility from researchers' point of view, here the ICU is arranged in I-Shape. POE is applied on Dongguk University Ilsan Hospital to simulate walking on LogWare where two NS are designed based on L- Shape and Seoul St. Mary's Hospital, The Catholic University of Korea where five NS are functional for ICU Intensive Care Unit, Surgical Intensive Care Unit (SICU), Medical Intensive Care Unit (MICU), Critical Care Unit (CCU), Korean Oriental Medical Care Unit which are mostly arranged in U-Shape, and walking pattern is recognized to be in a zigzag path. Method: T-Test is applied on two dependent communication variables: walkability and visibility, with confidence interval of 95%. This study systematically analyses the Nurse Station (NS) typo-morphology, and simulates nurse horizontal circulation, by computing round route visits to patient's bed, then estimating minimum round route on LogWare stop sequence software. The visual connectivity is measured on depth map graphs. Hence the aim is to reduce staff stress and fatigue for better patients care by minimizing staff horizontal travel time and to facilitate nurse walk path and support space distribution by increasing effectiveness in delivering care. Result: Applying visibility graph and isovist field on space syntax on I- Shape, L- Shape and U- Shape ICU (SICU, MICU and CCU) configuration, I-shape facilitated 20% more patients in linear view as they stir to rise from their beds from nurse station compared to U-shape. In conclusion, it was proved that U-Shape supply minimum walking and maximum visibility; and L shape provides just visibility as the nurse is at pivot. I shape provides panoramic view from the Nurse Station but very rigorous walking.
본 연구에서는 현장검사 (Point-of-Care Testing, POCT)를 목적으로 측방 유동 검사 스트립의 피크들을 분리하는 템플릿 정합법을 제안한다. 템플릿은 스트립의 제어 리건드 선과 대상 리건드 선 간격으로 떨어져 있는 두 개의 펄스로 구성된다. 이 템플릿을 스캔신호와 정합시켜 최대 응답 위치에서 피크들의 중심을 찾고, 주어진 위치에서 피크들을 분리한다. 제안한 방법을 바디텍메드사의 당화 혈색소 면역 검사 스트립과 동사의 형광 스트립 리더기에 적용하여 농도 측정 성능에 미치는 영향을 기존에 구현된 방법과 비교 검토하였다. 실험 결과 본 연구에서 제안한 방법은 장치나 검사 스트립에 종속적인 매개변수가 필요한 기존 방법과 동등한 성능을 보였다.
Bahk, Young Yil;Ahn, Seong Kyu;Jeon, Heung Jin;Na, Byoung-Kuk;Lee, Sung-Keun;Shin, Ho-Joon
Parasites, Hosts and Diseases
/
제60권4호
/
pp.281-288
/
2022
Malaria continues to be one of the most crucial infectious burdens in endemic areas worldwide, as well as for travelers visiting malaria transmission regions. It has been reported that 8-aminoquinolines are effective against the Plasmodium species, particularly primaquine, for anti-hypnozoite therapy in P. vivax malaria. However, primaquine causes acute hemolytic anemia in individuals with glucose-6-phosphate dehydrogenase (G6PD) deficiency. Therefore, G6PD deficiency testing should precede hypnozoite elimination with 8-aminoquinoline. Several point-of-care devices have been developed to detect G6PD deficiency. The aim of the present study was to evaluate the performance of a novel, quantitative G6PD diagnostics based on a metagenomic blue fluorescent protein (mBFP). We comparatively evaluated the sensitivity and specificity of the G6PD diagnostic modality with standard methods using 120 human whole blood samples. The G6PD deficiency was spectrophotometrically confirmed. The performance of the G6PD quantitative test kit was compared with that of a licensed control medical device, the G6PD strip. The G6PD quantitative test kit had a sensitivity of 95% (95% confidence interval (CI): 89.3-100%) and a specificity of 100% (95% CI: 94.3-100%). This study shows that the novel diagnostic G6PD quantitative test kit could be a cost-effective and time-efficient, and universally mandated screening tool for G6PD deficiency.
Ji, Sumin;Yang, Yeseul;Jeong, Yeji;Hwang, Sung-Hyun;Kim, Myung-Chul;Kim, Yongbaek
Journal of Veterinary Science
/
제22권1호
/
pp.14.1-14.11
/
2021
Background: Quantitation of urine protein is important in dogs with chronic kidney disease. Various analyzers are used to measure urine protein-to-creatinine ratios (UPCR). Objectives: This study aimed to compare the UPCR obtained by three types of analyzers (automated wet chemistry analyzer, in-house dry chemistry analyzer, and dipstick reading device) and investigate whether the differences could affect clinical decision process. Methods: Urine samples were collected from 115 dogs. UPCR values were obtained using three analyzers. Bland-Altman and Passing Bablok tests were used to analyze agreement between the UPCR values. Urine samples were classified as normal or proteinuria based on the UPCR values obtained by each analyzer and concordance in the classification evaluated with Cohen's kappa coefficient. Results: Passing and Bablok regression showed that there were proportional as well as constant difference between UPCR values obtained by a dipstick reading device and those obtained by the other analyzers. The concordance in the classification of proteinuria was very high (κ = 0.82) between the automated wet chemistry analyzer and in-house dry chemistry analyzer, while the dipstick reading device showed moderate concordance with the automated wet chemistry analyzer (κ = 0.52) and in-house dry chemistry analyzer (κ = 0.53). Conclusions: Although the urine dipstick test is simple and a widely used point-of-care test, our results indicate that UPCR values obtained by the dipstick test are not appropriate for clinical use. Inter-instrumental variability may affect clinical decision process based on UPCR values and should be emphasized in veterinary practice.
Avian influenza (AIV) outbreaks can induce fatal human pulmonary infections in addition to economic losses to the poultry industry. In this study, we aimed to develop a rapid and sensitive point-of-care AIV test using loop-mediated isothermal amplification (LAMP) technology. We designed three sets of reverse transcription LAMP (RT-LAMP) primers targeting the matrix (M) and hemagglutinin (HA) genes of the H5 and H9 subtypes. RT-LAMP targeting the universal M gene was designed to screen for the presence of AIV and RT-LAMP assays targeting H5-HA and H9-HA were designed to discriminate between the H5 and H9 subtypes. All three RT-LAMP assays showed specific amplification results without nonspecific reactions. In terms of sensitivity, the detection limits of our RT-LAMP assays were 100 to 1,000 RNA copies per reaction, which were 10 times more sensitive than the detection limits of the reference reverse-transcription polymerase chain reaction (RT-PCR) (1,000 to 10,000 RNA copies per reaction). The reaction time of our RT-LAMP assays was less than 30 min, which was approximately four times quicker than that of conventional RT-PCR. Altogether, these assays successfully detected the existence of AIV and discriminated between the H5 or H9 subtypes with higher sensitivity and less time than the conventional RT-PCR assay.
적정기술이 현장에서 널리 활용되기 위한 조건 중의 하나는 그 기술을 적용하기 위한 용이함과 경제성이 뒷받침 되어야 한다. 특히 질병의 진단은 전문 인력, 장비, 그리고 시약 등의 비용이 높아, 다른 분야에 비하여 개발도상국에 적용되기 가장 어려운 분야이다. 최근, 주변에 가장 흔한 소재 중의 하나인 종이를 기반으로, 특수한 시설이나 장비가 필요 없이도, 누구나 쉽게 배워서 제작하고, 사용할 수 있는 종이 진단칩 기술이 속속 개발되고 있다. 본 기술들은 특정 질병의 진단에 현장에서 신속하게 제작이 가능한 기술로 활용 가능한 현장진단 칩으로 연구되고 있으며, 그 활용 가능성이 커지고 있다. 이 기술들의 완성도가 높아지면, 개발도상국의 가장 큰 의료문제들을 해결하여, 궁극적으로 인간의 삶의 질을 향상시키는데 활용 될 수 있을 것이다.
스크린프린팅 된 탄소전극과 항체가 결합된 리포좀을 이용한 일회용 전기화학발광 면역센서를 구성하였다. 분석물질농도에 비례하여 분석물질-면역리포좀 복합체는 모세관현상에 의해 membrane strip에서 전극 상으로 전달되었고, 이 리포좀은 계면 활성제에 의해 파괴되고 신호발생에 이용되는 ruthenium이 방출되었다. 이와 같은 면역센서의 성능은 의료현장검사 혹은 자가진단에 적합할 것으로 예측된다.
119 구급대원들이 사용하는 현장 검사 장비 중 하나인 자가 혈당측정기는 결과 값이 정확해야 환자에게 적절한 처치를 제공할 수 있다. 연구 최초 조사 시점 이후 현재까지도 119 구급대원 현장업무 지침에 현장 검사 장비의 작동 유무, 수량 등을 확인하는 것은 있으나, 장비의 점검에 수량, 작동 여부 등은 있으나 본 연구에서 분석한 정도관리 내용은 없다. 현장검사 장비의 질 관리가 되지 않고 있다는 것은 환자에 대한 부정확한 평가와 이로 인한 불필요한 처치와 과소, 과대처치 또는 환자 상태가 악화될 가능성을 높일 수 있다. 본 연구를 통해, 앞으로 119 구급대원의 혈당측정기를 포함한 모든 현장검사 장비의 사용실태조사가 이루어져야 하고, 119 구급대 현장 업무 지침에 현장 검사 장비 정도관리를 추가하여야 하겠다. 또한, 현장 검사 장비가 관련 지침에 따라서 적절한 질 관리가 이루어져야 하고, 지역에서 관련 업무 전문가나 응급의료지도를 담당하고 있는 지도의사에게 관리되는 것이 합당하겠다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.