• Title/Summary/Keyword: Point light source

Search Result 148, Processing Time 0.025 seconds

Characteristics of integral imaging microscope using point light source array

  • Lim, Young-Tae;Park, Jae-Hyeung;Kwon, Ki-Chul;Kim, Nam
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1354-1356
    • /
    • 2009
  • In this paper, we explained characteristics of integral imaging microscope using point light source. To display the bio-medical information, which is captured as a form of the elemental images, using autostereoscopic displays, the characteristics analysis of three-dimensional information is required. For integral imaging microscope using point light source array, the elemental image capturing configuration has to satisfy a specific condition. We explain the condition to capture the elemental images and show the experimental results.

  • PDF

Coordinate Measuring Technique based on Optical Triangulation using the Two Images (두장의 사진을 이용한 광삼각법 삼차원측정)

  • 양주웅;이호재
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.76-80
    • /
    • 2000
  • This paper describes a coordinate measuring technique based on optical triangulation using the two images. To overcome the defect of structured light system which measures coordinate point by point, light source is replaced by CCD camera. Pixels in CCD camera were considered as virtual light source. The overall geometry including two camera images is modeled. Using this geometry, the formula for calculating 3D coordinate of specified point is derived. In a word, the ray from a virtual light source was reflected on measuring point and the corresponding image point was made on the other image. Through the simulation result, validation of formula is verified. This method enables to acquire multiple points detection by photographing.

  • PDF

Determining 3D-shape of specular objects by using an encoded grid pattern light source

  • Ye, Xiongying;Fujimura, Sadao
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1758-1763
    • /
    • 1991
  • This paper describes a new method to determine the 3D-shape of objects consisting of specular planar surfaces. This method exploits a light source which is made of a diffuse plane with a grid pattern encoded in an M-sequence and uses a single image of the light source reflected by the objects to acquiring orientations and positions of the surfaces of the objects. When grid lines of the light source are reflected by a specular planar surface and perspectively projected on an image plane, a set of lines vanishing at a point are obtained on the image plane. The orientation of the specular planar surface is determined by using the vanishing point, and the position is determined by using the correspondence between lines on the image and lines on the light source, which is obtained by employing a characteristic regularity of the M-sequence. Before the vanishing points are calculated, the lines on the image are classified and correlated with the surfaces of objects by using slopes and positions of the lines and the regularity of the M-sequence. This method requires only a single image.

  • PDF

2D/3D Convertible Integral Imaging Display Using Point Light Source Array Instrumented by Polarization Selective Scattering Film

  • Song, Byoungsub;Min, Sung-Wook
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.2
    • /
    • pp.162-167
    • /
    • 2013
  • A two-dimensional (2D) / three-dimensional (3D) convertible display system based on integral imaging is proposed to adopt a novel switchable point light source array, which is implemented using the polarization modulator and the polarization selective scattering film that transmits or scatters the incident light due to its polarization direction. The 2D and the 3D display modes of the proposed system can be modulated by controlling the polarization direction of back light using the polarization modulator. We explain the basic principles of the proposed system and verify the feasibility of the system through preliminary experiments.

Study on 3 Dimensional Images Using LED by PLS with No Viewing Zone Forming Optics (LED를 PLS 배열로 사용한 시역 형성 광학계가 없는 3차원 영상의 시역에 대한 연구)

  • Choi, Kyu-Hwan;Kim, Sung-Kyu;Son, Jung-Young
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.2
    • /
    • pp.116-121
    • /
    • 2008
  • A two dimensional point light source array can replace both the viewing zone forming optics and the back light panel in the contact-type 3 dimensional imaging systems based on LC panels. This replacement can make the system structure of the 3 dimensional imaging systems no different from that of the conventional LCD and can reduce undesirable visual effects caused by the viewing zone forming optics. The problem with the point light source array is the visual quality deterioration of the system due to the non-ideal nature of the array.

360-degree Viewable Cylindrical Integral Imaging System Using Electroluminescent Films

  • Jung, Jae-Hyun;Park, Gil-Bae;Kim, Yun-Hee;Lee, Byoung-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1254-1257
    • /
    • 2009
  • A 360-degree viewable three-dimensional display based on integral imaging is proposed. The cylindrically arranged point light source array which is generated by electroluminescent (EL) pinhole film reconstructs 360-degree viewable virtual 3D image at the center of the cylinder. In this paper, the principle of operation and experimental results are presented.

  • PDF

360-degree Viewable Cylindrical Integral Imaging System Using Electroluminescent Films

  • Jung, Jae-Hyun;Park, Gil-Bae;Kim, Yun-Hee;Lee, Byoung-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1330-1333
    • /
    • 2009
  • A 360-degree viewable three-dimensional display based on integral imaging is proposed. The cylindrically arranged point light source array which is generated by electroluminescent (EL) pinhole film reconstructs 360-degree viewable virtual 3D image at the center of the cylinder. In this paper, the principle of operation and experimental results are presented.

  • PDF

Development of the Fluorescence Endoscope System with Dual Light Source Apparatus (복합 광원을 갖는 형광 내시경 개발)

  • Bae, Soo-Jin;Kang, Uk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.222-226
    • /
    • 2007
  • We suggest the fluorescence endoscope system that has light source apparatus providing selectable white or excitation light. White light source generates normal color images and is easily switched over to excitation light with the wide spectrum range from 380 nm to 580 nm. 5-ALA is deposited selectively in the abnormal tissue like cancer and causes fluorescence in the red spectrum range when excited by blue spectrum range. In addition, the others of excitation light make the color background image by reflected light to allow accurate orientation and visualization of the abnormal tissue and around. According to clinical studies, the fluorescence intensity contrast that defines the fluorescence intensity of lesion over the fluorescence intensity of around has more than 2 in tumour. Proposed system is useful and objective way in early diagnosis. Furthermore, it can be used in the biopsy for tumour classification at the highest fluorescence intensity point.

The scanned point-detecting system for three-dimensional measurement of light emitted from plasplay panel (플라즈마 디스플레이 패널에서 방출되는 광의 3차원 측정을 위한 Scanned Point-Detecting System)

  • 최훈영;이석현;이승걸
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.2
    • /
    • pp.103-108
    • /
    • 2001
  • In this paper, we designed and made the scanned point detecting system for 3-dimensional measurement of the light emitted from plasma display panel (PDP) , and we measured and analyzed 3-dimensional light emitted from a real PDP by using this scanned point detecting system. The scanned point detecting system has a point detector with a pinhole. The light emitted from the source at the in-focus position can pass through the pinhole and be collected by detector. The light from other sources at outof-focus positions is focused at points in front of or behind the pinhole, and thus it is intercepted by the pinhole. Therefore, we can detect light information from a particular point of a PDP cell of 3-dimensional structure. We know the electric field distribution inside the PDP cell from the 3-dimensionallight intensity distribution measured by using the scanned point detecting system. As the Z axial measurement increases, the intensity of light detected increases and intensity of light detected on the inside edge of the ITa electrode is larger than outside edge of the ITa eletrode and gap of the ITa electrodes. Also, as the measurement point moves from one barrier rib to another, the detected light is weaker near to the barrier ribs than at the center between the barrier ribs. The emitted light is concentrated at the center between barrier ribs. ribs.

  • PDF

Diffractive Optical Element for Noise-reduced Beam Shaping of Multi-array Point Light Source

  • Lee, Jonghyun;Hahn, Joonku;Kim, Hwi
    • Current Optics and Photonics
    • /
    • v.5 no.5
    • /
    • pp.506-513
    • /
    • 2021
  • An arrayed diffractive optical element design for the beam-shaping of a multi-array light source is proposed. This is an essential device for recent optical security and face recognition applications. In practice, we devise a DC noise reduction technique featuring high fabrication error tolerance regarding the multi-array light source diffractive optical elements, as a necessary part of the proposed design method. The spherical diverging illumination leads to DC-conjugate noise spreading. The main idea is tested experimentally, and the multi-array light source diffraction pattern is investigated numerically.