• 제목/요약/키워드: Point Placement

검색결과 191건 처리시간 0.023초

수동 RFID 기반 이동로봇 위치 추정 및 효율적 노면 태그 배치 (Passive RFID Based Mobile Robot Localization and Effective Floor Tag Arrangement)

  • 김성복;이상협
    • 제어로봇시스템학회논문지
    • /
    • 제14권12호
    • /
    • pp.1294-1301
    • /
    • 2008
  • Under passive RFID environment, this paper presents a new localization of a mobile robot traversing over the floor covered with tags, which is superior to existing methods in terms of estimation performance and cost effectiveness. Basically, it is assumed that a mobile robot is traveling along a series of straight line segments, each segment at a certain constant velocity, and that the number of tags sensed by a mobile robot at each sampling instant is at most one. First, for a given line segment with known starting point, the velocity and position of a mobile robot is estimated using the spatial and temporal information acquired from the traversed tag. Some discussions are made on the validity of the basic assumptions and the localization for the initial segment with unknown starting point. Second, for a given tag distribution density, the optimal tag arrangement is considered to reduce the position estimation error as well as to make easy the tag attachment on the floor. After reviewing typical tag arrangements, the pseudorandom tag arrangement is devised inspired from the Sudoku puzzle, a number placement puzzle. Third, through experiments using our passive RFID localization system, the validity and performance of the mobile robot localization proposed in this paper is demonstrated.

A numerical method for improving the reliability of knee translation measurement in skin marker-based motion analysis

  • Wang, Hongsheng;Zheng, Nigel
    • Advances in biomechanics and applications
    • /
    • 제1권4호
    • /
    • pp.269-277
    • /
    • 2014
  • In skin-marker based motion analysis, knee translation measurement is highly dependent on a pre-selected reference point (functional center) on each segment determined by the location of anatomical landmarks. However, the placement of skin markers on palpable anatomical landmarks (i.e., femoral epicondyles) has limited reproducibility. Thus, it produces large variances in knee translation measurement among different subjects, as well as across studies. In order improve the repeatability of knee translation measurement, in this study an optimization method was introduced, by which the femoral functional center was numerically determined. At that point the knee anteroposterior translation during the stance phase of walking was minimized. This new method was tested on 30 healthy subjects during walking in gait lab with motion capture system. Using this new method, the impact of skin marker position (at anatomical landmarks) on the knee translation measurement has been minimized. In addition, the ranges of anteroposterior knee translations during stance phase were significantly (p<0.001) smaller than those measured by conventional method which relies on a pre-selected functional center ($11.1{\pm}3.5mm$ vs. $19.9{\pm}5.5mm$). The results of anteroposterior translation using this new method were very close to a previously reported knee translation (12.4 mm) from dual fluoroscopic imaging technique. Moreover, this new method increased the reproducibility of knee translation measurement by 50%.

경락 임피던스 측정 시스템 개발에 관한 연구 (Study on the Development of Meridian Impedance Measurement System)

  • 이우철;인창식;민경기
    • 전기학회논문지
    • /
    • 제58권2호
    • /
    • pp.422-429
    • /
    • 2009
  • Meridian which used as the basic theory of acupuncture treatment, is an important functional connection system of acupuncture point in oriental medicine. Yangdorak and EAV have lack of precision because of using 2-electrode method, occurring high non-uniformed current density and electrode contact status on electrode placement spot. Therefore we implemented a meridian impedance measurement system for measuring meridian impedance using 4-electrode method. In order to confirm the precision of developed system, we made an constant current characteristic experiment using standard resistor. As a results of clinical study with 18 subjects, the meridian impedance showed that reproductivity and repeatability of HT7 acupuncture point are $0.515[k{\Omega}]{\pm}0.000$(mean${\pm}$standard deviation) and $0.515[k{\Omega}]{\pm}0.002$, respectively. And reproductivity and repeatability of PC7 are $0.521[k{\Omega}]{\pm}0.000$ and $0.521[{\Omega}]{\pm}0.001$ respectively. The proposed system was stable and reliable. Therefore this study proved AC impedance method to valid in measuring meridian impedance, and also verified precision and repeatability of the proposed meridian impedance measurement system. The proposed system will serve as more effective method of measuring meridian phenomena as a bioelectric signal in clinical practice.

메를로-퐁티의 현상학을 통해서 본 한국전통공간의 특성에 관한 연구 - 독락당을 중심으로 - (A Study on the Characteristics of Korean Traditional Space through Merleau-Ponty's Phenomenology - Focusing on Dok Rak Dang -)

  • 이찬;김태우
    • 한국실내디자인학회논문집
    • /
    • 제15권6호
    • /
    • pp.11-18
    • /
    • 2006
  • Ceaseless studies and efforts to verify today's Korean nature that has advanced into digital era of 21C are continued. At this point of time, it is required to look back our heritage in diverse points of view free from theoretical and formal studies on our traditional spaces. Phenomenology, which is rising as the important theme in recent modem Western philosophy, suggests interesting analyses from this standpoint. This study is intended to analyze Korea's traditional residents 'Dok Rak Dang' based on Marleau-Ponty's phenomenology, and explore phenomenological spatial principle and new point of view implied in it. Particularly, Marleau-Ponty's phenomenology is the philosophy that shows intersubjective and involved relations between space and human, and intended to accept coincidental incidents occurred by human's action truthfully as they are. With three spatial concepts of direction, depth, and movement in Ponty's phenomenology, and placement nature of the earth that intercombine with human's body who is subject of these three concepts as analyze tool, Korea's traditional residents, 'Dok Rak Dang' has been analyzed. More segmentalized analyses have been deduced, and principle of phenomenology, that perceptions such as direction, depth, movement, etc are working synthetically to be accepted as essence of experiences could also be found in Dok Rak Dang.

Finite element analysis of long-term changes of the breast after augmentation mammoplasty: Implications for implant design

  • Myung, Yujin;Lee, Jong-Gu;Cho, Maenghyo;Heo, Chan Yeong
    • Archives of Plastic Surgery
    • /
    • 제46권4호
    • /
    • pp.386-389
    • /
    • 2019
  • The development of breast implant technology continues to evolve over time, but changes in breast shape after implantation have not been fully elucidated. Thus, we performed computerized finite element analysis in order to better understand the trajectory of changes and stress variation after breast implantation. The finite element analysis of changes in breast shape involved two components: a static analysis of the position where the implant is inserted, and a dynamic analysis of the downward pressure applied in the direction of gravity during physical activity. Through this finite element analysis, in terms of extrinsic changes, it was found that the dimensions of the breast implant and the position of the top-point did not directly correspond to the trajectory of changes in the breast after implantation. In addition, in terms of internal changes, static and dynamic analysis showed that implants with a lower top-point led to an increased amount of stress applied to the lower thorax. The maximum stress values were 1.6 to 2 times larger in the dynamic analysis than in the static analysis. This finding has important implications for plastic surgeons who are concerned with long-term changes or side effects, such as bottoming-out, after anatomic implant placement.

Accuracy and Safety of Bedside External Ventricular Drain Placement at Two Different Cranial Sites : Kocher's Point versus Forehead

  • Park, Young-Gil;Woo, Hyun-Jin;Kim, Il-Man;Park, Jae-Chan
    • Journal of Korean Neurosurgical Society
    • /
    • 제50권4호
    • /
    • pp.317-321
    • /
    • 2011
  • Objective : External ventricular drain (EVD) is commonly performed with a freehand technique using surface anatomical landmarks at two different cranial sites, Kocher's point and the forehead. The aim of this study was to evaluate and compare the accuracy and safety of these percutaneous ventriculostomies. Methods : A retrospectively review of medical records and head computed tomography scans were examined in 227 patients who underwent 250 freehand pass ventriculostomy catheter placements using two different methods at two institutions, between 2003 and 2009. Eighty-one patients underwent 101 ventriculostomies using Kocher's point (group 1), whereas 146 patients underwent 149 forehead ventriculostomies (group 2). Results : In group 1, the catheter tip was optimally placed in either the ipsilateral frontal horn or the third ventricle, through the foramen of Monro (grade 1) in 82 (81.1%) procedures, in the contralateral lateral ventricle (grade 2) in 4 (3.9%), and into eloquent structures or non-target cerebrospinal space (grade 3) in 15 (14.8%). Intracerebral hemorrhage (ICH) >1 mL developed in 5 (5.0%) procedures. Significantly higher incidences of optimal catheter placements were observed in group 2. ICH>1 mL developed in 11 (7.4 %) procedures in group 2, showing no significant difference between groups. In addition, the mean interval from the EVD to ventriculoperitoneal shunt was shorter in group 2 than in group 1, and the incidence of EVD-related infection was decreased in group 2. Conclusion : Accurate and safe ventriculostomies were achieved using both cranial sites, Kocher's point and the forehead. However, the forehead ventriculostomies provided more accurate ventricular punctures.

A Preliminary Study on the Yang-cheon-cheok (量天尺) in the Late Joseon Dynasty

  • Kim, Sang Hyuk;Mihn, Byeong-Hee;Lee, Yong Sam
    • Journal of Astronomy and Space Sciences
    • /
    • 제32권4호
    • /
    • pp.395-401
    • /
    • 2015
  • We investigated the six remaining Yang-cheon-cheoks (量天尺), which were first described in the Veritable Record of King Sukjong (肅宗實錄). These woodblock sundials from Korea are structurally very similar to a Gyupyo (圭表, gnomon) or an altitude sundial and are light, compact, and portable. The front side of a Yang-cheon-cheok has two holes for styluses and several hour-lines. We compared the intervals of the hour-lines from the originating point of the stylus placement on all Yang-cheon-cheoks and found that two of the relics had the same hour-lines using the standard of the unit of 1 chon (寸). These two were actually the same sundial although the physical size was different. In spite of the lack of time accuracy, we hypothesize that various-sized Yang-cheon-cheoks were made and widely distributed throughout the public in the late Joseon Dynasty.

4Degrees of freedom control for a magnetically levitated vehicle

  • Kim, Kook-Hun;Kim, Choon-Kyung;Kim, Jong-Moon;Cho, Chang-Hee;Park, Min-Kook
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국제학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.327-332
    • /
    • 1993
  • One maglev vehicle is composed of 6 r 8 modules. Each module is composed of 4 staggered magnets attached to an aluminum bogie. In the view point of levitation control except propulsion by LIM, 5 is the maximum degrees of freedo to be controlled. But rolling control of the vehicle depends on the bogie structure. We describe just anti-roll type out of bogie structures and 4 degrees of freedom control is sufficient for levitation quality improvement. Multivariable pole-placement concept and the decentralized control concept are used for controller design. Computer simulation and control experiment are performed on a specially designed test module.

  • PDF

전통가옥에 있어서 도사상의 도입을 통한 공간연구 (A study of Dimension in Korea traditional House as the Adaptation of thoughts of Truth)

  • 양우창
    • 한국실내디자인학회논문집
    • /
    • 제11호
    • /
    • pp.20-25
    • /
    • 1997
  • The purpose of this study is to find out the correlation between Truth(道) and dimension through the understanding of architectural point of value in the aspect of correlation between modern western thoughts and the thoughts of Truth and also through the reading of what kind of composite trend of the Truth can be seen in a Korea traditional house. This stduy takes the following procedure with reference books and traditional house that we have. 1) Making foundation for this study by finding out the fundamental meaning of the thoughts of Truth through the comparing and analyzing between modern western thoughts and the thoughts of Truth. 2) Reviewing the understanding of dimension in the thoughts of Truth. 3) Traslation of the organic correlation through the analysis of composition, placement and characteristics of dimension in a real present traditional Korea house. 4) Finding out the meaning of each dimension through the adaptation of the fundamental rules of nature of Jane(藏:store), Sang(生:life), Jang(長:long), Su(收obtain) to the dimension composite of a traditional house and concluding that the cyclical process in the oriental thoughts could be made.

  • PDF

Placement of Colloidal Silica gel for the construction of a subsurface containment system

  • Kim, Meejeong;Park, Joo-Yang
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 총회 및 춘계학술발표회
    • /
    • pp.66-69
    • /
    • 2001
  • A subsurface containment system which is constructed by pumping a gelling liquid (Colloidal Silica) into the unsaturated medium is investigated by developing a mathematical model and conducting numerical simulations. The proposed model is verified by comparing experimentally and numerically determined hydraulic conductivities of gel-treated soil columns at different Colloidal Silica (CS) injection volumes. The numerical experiments indicate that an impermeable gel layer is formed within the time period twice the gel-point. At the Same normalized time, the CS solutions with lower NaCl concentrations result ill further migration and poor Performance in plugging the pore space.

  • PDF