• Title/Summary/Keyword: Point Placement

Search Result 191, Processing Time 0.031 seconds

An Efficient Datapath Placement Algorithm to Minimize Track Density Using Spectral Method (스팩트럴 방법을 이용해 트랙 밀도를 최소화 할 수 있는 효과적인 데이터패스 배치 알고리즘)

  • Seong, Gwang-Su
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.2
    • /
    • pp.55-64
    • /
    • 2000
  • In this paper, we propose an efficient datapath placement algorithm to minimize track density. Here, we consider each datapath element as a cluster, and merge the most strongly connected two clusters to a new cluster until only one cluster remains. As nodes in the two clusters to be merged are already linearly ordered respectively, we can merge two clusters with connecting them. The proposed algorithm produces circular linear ordering by connecting starting point and end point of the final cluster, and n different linear ordering by cutting between two contiguous elements of the circular linear ordering. Among the n different linear ordering, the linear ordering to minimize track density is final solution. In this paper, we show and utilize that if two clusters are strongly connected in a graph, the inner product of the corresponding vectors mapped in d-dimensional space using spectral method is maximum. Compared with previous datapath placement algorithm GA/S $A^{[2]}$, the proposed algorithm gives similar results with much less computation time.

  • PDF

Efficacy and safety of low dose oral ketamine for controlling pain and distress during intravenous cannulation in children: a double-blind, randomized, placebo-controlled trial

  • Bagheri, Mahdi;Soltani, Alireza Ebrahim;Qorbani, Mostafa;Sureda, Antoni;Faghihi, Toktam
    • The Korean Journal of Pain
    • /
    • v.35 no.3
    • /
    • pp.311-318
    • /
    • 2022
  • Background: Ketamine is widely used in infants and young children for procedural sedation and anesthesia. The aim of this study was to evaluate the efficacy and safety of low dose oral ketamine to control pain and distress in children during intravenous (IV) cannulation. Methods: This is a prospective, randomized, double-blind study, including children aged between 3 and 6 years requiring a non-emergent IV-line placement. Children were randomly assigned to two groups, treated either with oral ketamine or a placebo. All patients were monitored for vital signs. Pain was assessed using the Children's Hospital of Eastern Ontario Pain Scale (CHEOPS) and Wong-Baker Faces Pain Rating Scale (WBFS) scales and sedation using a 5-point sedation score. The facility of IV-line placement was measured by a 3-point scale. Adverse effects were recorded after 1 and 24 hours. Results: A total of 79 and 81 children were entered in the ketamine and placebo groups, respectively. The heart and respiratory rates increased significantly in the placebo group. The median CHEOPS 4 (95% confidence interval [CI]: 3, 4, P < 0.001) and WBFS 6 (95% CI: 4, 6, P < 0.001) scores decreased statistically in the ketamine group. IV-line placement was 50% easier in the ketamine group (95% CI: 37%, 63%, P < 0.001). No serious adverse effects were observed in all cases. Conclusions: Low dose oral ketamine effectively decreased the pain and distress during IV cannulation in children without any significant adverse reactions.

A Study on the Strength Estimation of Concrete Using Microwave (마이크로파를 이용한 콘크리트 강도추정에 관한 연구)

  • 박일용;이종균;박영진;안형준;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.219-222
    • /
    • 1999
  • Concrete is to be important quality in placement point and exact test method needed about early judgement method concrete on placement point. But early judgement method of concrete proposed various kind of method because the problems of accuracy and the time required of test exists, it is used within the limits. This study is to propose of early strength judgement by using microwave for accurate estimating early strength of concrete and to develop test machine. Through out this study we find that belows. 1) Strength development of concrete specimen according to the time heated by microwave showed the height strength development in 9 minutes regardless of slump and w/c. 2) As cooling time is long, strength of concrete specimen according to the time heated by microwave showed high strength development and this tendency is like regardless of heating time, w/c and slump. 3) As w/c is high, accelerating strength development according to w/c showed lower strength development and this tendency is like regardless of slump, heating time and cooling time. 4) As slump is big, compressive strength of specimen in standard curing showed lower value and as w/c is big, strength development showed lower

  • PDF

Sensor placement selection of SHM using tolerance domain and second order eigenvalue sensitivity

  • He, L.;Zhang, C.W.;Ou, J.P.
    • Smart Structures and Systems
    • /
    • v.2 no.2
    • /
    • pp.189-208
    • /
    • 2006
  • Monitoring large-scale civil engineering structures such as offshore platforms and high-large buildings requires a large number of sensors of different types. Innovative sensor data information technologies are very extremely important for data transmission, storage and retrieval of large volume sensor data generated from large sensor networks. How to obtain the optimal sensor set and placement is more and more concerned by researchers in vibration-based SHM. In this paper, a method of determining the sensor location which aims to extract the dynamic parameter effectively is presented. The method selects the number and place of sensor being installed on or in structure by through the tolerance domain statistical inference algorithm combined with second order sensitivity technology. The method proposal first finds and determines the sub-set sensors from the theoretic measure point derived from analytical model by the statistical tolerance domain procedure under the principle of modal effective independence. The second step is to judge whether the sorted out measured point set has sensitive to the dynamic change of structure by utilizing second order characteristic value sensitivity analysis. A 76-high-building benchmark mode and an offshore platform structure sensor optimal selection are demonstrated and result shows that the method is available and feasible.

3D Simulation Study of Biped Robot Balance Using FPE Method (FPE 방식을 활용한 이족 로봇 균형 유지 3차원 시뮬레이션 연구)

  • Jang, Tae-ho;Kim, Youngshik;Ryu, Bong-Jo
    • Journal of Digital Contents Society
    • /
    • v.19 no.4
    • /
    • pp.815-819
    • /
    • 2018
  • In this study, we investigate balance of a biped robot applying Foot Placement Estimator (FPE) in simulation. FPE method is used to determine a stable foot location for balancing the biped robot when an initial orientation of the robot body is statically unstable. In this case, the 6-DOF biped robot with point foot is modelled considering contact and friction between foot and the ground. For simulation, the mass of the robot is 1 kg assuming the center of robot mass (COM) is located at the center of the robot body. The height from the ground to the COM is 1 m. Robot balance is achieved applying stable foot locations calculated from FPE method using linear and angular velocities, and the height of the COM. The initially unstable angular postures, $5^{\circ}$ and $-5^{\circ}$, of the robot body are simulated. Simulation results confirm that the FPE method provides stable balance of the robot for all given unstable initial conditions.

Placement Standard Research of Auxiliary Probes when Measuring Ground Impedance (접지임피던스 측정시 보조전극의 배치 기준 연구)

  • Kim, Dong-Woo;Gil, Hyoung-Jun;Kim, Dong-Ook;Lee, Ki-Yeon;Moon, Hyun-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.10
    • /
    • pp.1984-1991
    • /
    • 2011
  • Among ground impedance measurement methods, the fall-of-potential method is the most thorough and reliable method. In the fall-of-potential method, ground electrode and auxiliary probes are placed in a straight line, and then, auxiliary potential probe is moved away from the ground electrode. The point at which plotted resistance curve flattens out is taken as right position of auxiliary potential probe. However, in some cases, it is hard to place ground electrode and auxiliary probes in a straight line. Therefore, we provided alternative placement method in this research. The method can be easily applicable to placing auxiliary probes. Also, this paper analyzed and compared ground impedance measurement standards of large grounding systems. Based on the analysis, practical measurement method using an earth tester was proposed. The proposed methods presented in this paper will be useful when determining locations of auxiliary probes in alternative positions, and the methods can be applied practically and easily.

Overview of the PCL Reconstruction (후방 십자 인대 손상 치료의 개관(over view))

  • Jung, Young Bok
    • Journal of the Korean Arthroscopy Society
    • /
    • v.2 no.1
    • /
    • pp.1-3
    • /
    • 1998
  • The PCL reconstruction in chronic isolate PCL reconstruction was still controversy. 1) In isolate PCL deficient knee, functionally not so bad as like ACL deficient knee. 2) The result of the PCL reconstruction was not as good as ACL reconstruction. Therefore, isolate PCL injuries has been treated as nonoperatively. Hey Grovere, who was the first to attempt an intra-articular reconstruction of the PCL, utilized the semi-tendinous tendon other static procedures have been described in only a few cases with very limited follow-up. Dynamic procedures utilizing the medial head of the gastrocnemius has been reported by Hugston and Degenhardt, Kennedy and Grainger, and Insall and Hood. These procedures did not improve static stability. Dr Clancy, who was introduce the use of BPTB for the PCL reconstruction transtibial and femoral tunnel. From 1995, untill early 1990 PCL reconstruction was done as tend as placement of the isometric point. Physiometic placement of Anatomical placement of the femoral tunnel in PCL reconstruction were introduced in 1995. Tibial Inlay Technique was reported by Dr Berg in 1995. The main advantage of the tibial Inlay Technique was to avoid fraying of the graft at the posterior tibial tunnel orifice. In complete PCL ruptured and severely posterior unstable knee, dual femoral tunnel technique will be to get better result than one bundle technique. To achieve restoration of normal posterior laxity, it is critical to address the posterior as well as the posterolateral structures. Futher research is necessary to evaluate new surgical approches such as double-bundle reconstructions and tibial inlay techniques as well as improved techniques for capsular and collateral ligament injuries.

  • PDF

Effect of Electromagnetic Navigated Ventriculoperitoneal Shunt Placement on Failure Rates

  • Jung, Nayoung;Kim, Dongwon
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.3
    • /
    • pp.150-154
    • /
    • 2013
  • Objective : To evaluate the effect of electromagnetic (EM) navigation system on ventriculoperitoneal (VP) shunt failure rate through comparing the result of standard shunt placement. Methods : All patients undergoing VP shunt from October 2007 to September 2010 were included in this retrospective study. The first group received shunt surgery using EM navigation. The second group had catheters inserted using manual method with anatomical landmark. The relationship between proximal catheter position and shunt revision rate was evaluated using postoperative computed tomography by a 3-point scale. 1) Grade I; optimal position free-floating in cerebrospinal fluid, 2) Grade II; touching choroid or ventricular wall, 3) Grade III; tip within parenchyma. Results : A total of 72 patients were participated, 27 with EM navigated shunts and 45 with standard shunts. Grade I was found in 25 patients from group 1 and 32 patients from group 2. Only 2 patients without use of navigation belonged to grade III. Proximal obstruction took place 7% in grade I, 15% in grade II and 100% in grade III. Shunt revision occurred in 11% of group 1 and 31% of group 2. Compared in terms of proximal catheter position, there was growing trend of revision rate according to increase of grade on each group. Although infection rate was similar between both groups, the result had no statistical meaning (p=0.905, chi-square test). Conclusion : The use of EM navigation in routine shunt surgery can eliminate poor shunt placement resulting in a dramatic reduction in failure rates.

GCP Placement Methods for Improving the Accuracy of Shoreline Extraction in Coastal Video Monitoring

  • Changyul Lee;Kideok Do;Inho Kim;Sungyeol Chang
    • Journal of Ocean Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.174-186
    • /
    • 2024
  • In coastal video monitoring, the direct linear transform (DLT) method with ground control points (GCPs) is commonly used for geo-rectification. However, current practices often overlook the impact of GCP quantity, arrangement, and the geographical characteristics of beaches. To address this, we designed scenarios at Chuam Beach to evaluate how factors such as the distance from the camera to GCPs, the number of GCPs, and the height of each point affect the DLT method. Accuracy was assessed by calculating the root mean square error of the distance errors between the actual GCP coordinates and the image coordinates for each setting. This analysis aims to propose an optimal GCP placement method. Our results show that placing GCPs within 200 m of the camera ensures high accuracy with few points, whereas positioning them at strategic heights enhances shoreline extraction. However, since only fixed cameras were used in this study, factors like varying heights, orientations, and resolutions could not be considered. Based on data from a single location, we propose an optimal method for GCP placement that takes into account distance, number, and height using the DLT method.

Back-Face Strain Compliance Calibration for the Four-Point Bend Specimen

  • Huh, Yong-Hak;Song, Ji-Ho
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.314-319
    • /
    • 2000
  • Back-face strain compliance (BFS compliance) for the four-point bend specimen has been calibrated for various crack length ratios. Finite element technique was employed to simulate four-point loading and calculate back-face strain of the bend specimen. The numerically determined strain variation along the back face indicates that the sensitivity to gage placement increases with crack length and back-face strain at the gage length less than O.2W, where W is the width of the bend specimen, can be measured within 5% deviation of the maximum BFS. Non-dimensional back-face strain compliance, -E'BCW, was calibrated with FE analysis and experiment. The experimentally determined compliance indicates good agreement with the numerical compliance and can be expressed as a function of crack length ratio.

  • PDF