• 제목/요약/키워드: Point Heat Source

검색결과 149건 처리시간 0.019초

고융점 소재의 열 보조 가공에서 레이저 -플라즈마 다중열원의 예열 효과에 대한 연구 (A Study on the Preheating Effect of Multi-Heat Sources using Laser Plasma in the Thermally Assisted Machining of a High-Melting-Point Material)

  • 이춘만;김성규
    • 한국기계가공학회지
    • /
    • 제18권10호
    • /
    • pp.93-98
    • /
    • 2019
  • Recently, with the development of the aerospace and automotive industries, the demand for high-melting-point materials has increased. However, high-melting-point materials are difficult to cut through conventional machining methods. Thermally assisted machining (TAM) is a method for improving the machinability by preheating the materials. A laser, the most commonly used device for TAM, has high efficiency through local preheating but is not sufficient for maintaining a high preheating temperature due to rapid cooling. However, the use of multi-heat sources can supplement the disadvantage of a single heat source. The high preheating temperature can be maintained with a wide and deep heat-affected zone (HAZ) by multi-heat sources. The purpose of this study is to analyze the preheating effects of multi-heat sources using laser plasma. Thermal analysis and preheating experiments were carried out. As a result, the high preheating effect of multi-heat sources compared with a single heat source was verified.

An Analytical Investigation on the Build-up of the Temperature Field due to a Point Heat Source in Shallow Coastal Water with Oscillatory Alongshore-flow

  • Jung, Kyung-Tae;Kim, Chong-Hak;Jang, Chan-Joo;Lee, Ho-Jin;Kang, Sok-Kuh;Yjm, Ki-Dai
    • Ocean and Polar Research
    • /
    • 제25권1호
    • /
    • pp.63-74
    • /
    • 2003
  • The build-up of the heat field in shallow coastal water due to a point source has been investigated using an analytical solution of a time-integral form derived by extending the solutions by Holley(1969) and also presented in Harleman (1971). The uniform water depth is assumed with non-isotropic turbulent dispersion. The alongshore-flow is assumed to be uni-directional, spatially uniform and oscillatory. Due to the presence of the oscillatory alongshore-flow, the heat build-up occurs in an oscillatory manner, and the excess temperature thereby fluctuates in that course and even in the quasi-steady state. A series of calculations reveal that proper choices of the decay coefficient as well as dispersion coefficients are critical to the reliable prediction of the excess temperature field. The dispersion coefficients determine the absolute values of the excess temperature and characterize the shoreline profile, particularly within the tidal excursion distance, while the decay coefficient determines the absolute value of the excess temperature and the convergence rate to that of the quasi-steady state. Within the e-folding time scale $1/k_d$ (where $k_d$ is the heat decay coefficient), heat build-up occurs more than 90% of the quasi-steady state values in a region within a tidal excursion distance (L), while occurs increasingly less the farther we go to the downstream direction (about 80% at 1.25L, and 70% at 1.5L). Calculations with onshore and offshore discharges indicate that thermal spreading in the direction of the shoreline is reduced as the shoreline constraint which controls the lateral mixing is reduced. The importance of collecting long-term records of in situ meteorological conditions and clarifying the definition of the heat loss coefficient is addressed. Interactive use of analytical and numerical modeling is recommended as a desirable way to obtain a reliable estimate of the far-field excess temperature along with extensive field measurements.

열원 및 공조설비의 최적제어시스템 현장 적용성에 관한 연구 (A Study on the Application of the Optimal Control System for Heat Source and HVAC System)

  • 백승재;김진;안병천;송재엽
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1014-1019
    • /
    • 2009
  • The optimal control system for heat source and HVAC system has been developed for minimizing energy consumption while maintaining the comfort of indoor thermal environment in terms of the environmental variables such as time varying indoor load and outdoor temperatures. The optimal set-points of control parameters are supply air temperature and chilled or hot water temperatures. The optimal control study has been implemented for biosafety laboratory by using TRNSYS simulation program in order to investigate energy performance for heat source and HVAC system.

  • PDF

용접중 이동하는 열원에 의한 온도분포에 관한 연구 (A Study on the Distribution of Temperature by Moving Heat Source during Welding)

  • 왕지석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제6권2호
    • /
    • pp.51-68
    • /
    • 1982
  • A method of calculation of temperature distribution during welding was studied and compared with the existing formulas and experimental results. In contrast to the existing formulas which are founded on the suppositions that the heat source is a point and that the dimensions of welded pieces are infinite, we tried to make the distribution of calorific density of heat source approach reality more closely, so we considered it as a normal distribution of Gauss, and we presented the formulas for calculation of temperature during welding. We also used the principle of superposition for the temperature calculations of finite welded pieces. We compared the formulas presented in this paper with the existing formulas by calculations for the welding of various materials, and considerable differences around the heat source were convinced. The thermal cycles of various points were traced through the welding experiments for the mild steel, and they were compared with the results of calculations.

  • PDF

가용에너지를 이용한 대향류 열교환기의 해석 (Analysis of Counterflow Heat Exchangers with the Concept of Available Energy)

  • 김수연;정평석
    • 대한기계학회논문집
    • /
    • 제16권11호
    • /
    • pp.2189-2195
    • /
    • 1992
  • 본 연구에서는 대향류 열교환기에 대하여 출력과 효율 등을 계산하는 예를 보 이고, 동시에 최대의 출력을 얻기 위한 조건들을 수치적으로 구하였다. 또한 열교환 기의 장치비용과 열원의 생성비용을 적절히 취급하여 경제적 최적조건에 대해서도 살 펴보고자 한다. 여기서 저온유체의 가용 에너지 획득량으로서 출력은 열전달로 인한 부분만을 생각하기로 한다.

생태도시에서의 자원활용에 관한 연구 -하수 에너지 활용을 위한 보유열량 평가- (Study on Utilizing Resources in Ecopolis -Evaluation of the Potential Heat Capacity of Sewage For Utilizing as Sewage Energy-)

  • 정용현
    • 한국환경과학회지
    • /
    • 제12권6호
    • /
    • pp.583-591
    • /
    • 2003
  • The research on potential energy was conducted to conserve the high-exergy energy like primary energy and utilize waste heat from sewage. From the Point of view in using the waste heat, the energy Potential of waste water from the model house was simulated. From the results, when the heated water was supplied to the model house side in order to put unused energy to Practice use, heated water had higher energy Potential than unheated water, which was due to the discharge of most of unused energy. The possessing heat capacity of sewage from heated water was increased to 40-70 percents in comparison with that from the unheated water. Therefore, it can be used as energy source for improving coefficient of performance of heat pumps. By adopting the multiple heat pump into a model house, It showed that the possessing heat capacity of sewage was reduced. It was also found that the heat was recovered as energy source fur multiple heat pump in a model house.

원판(圓板)에서 동심원상(同心圓上)을 이동(移動)하는 열원(熱源)에 의(依)한 과도적(過渡的) 열응력해석(熱應力解析) (Transent Thermal Stresses in a Thin Circular Disk due to a Moving Point Source of Heat on a Concentric Circle)

  • 김효철
    • 대한조선학회지
    • /
    • 제12권2호
    • /
    • pp.13-34
    • /
    • 1975
  • Analytical solutions for the transient temperature distribution and quasi-static thermal stresses which arise in a thin circular disk of finite radius subjected to an instantaneous point source acting in its interior have been obtained. And the solutions have been extended to the case of a moving heat source with the aid of the Duhamel's superposition integral. The solutions given are in the form of double infinite serieses, and their numerical results have been compared with the experimental temperature histories. It can be found out that the theoretical histories of thermal stresses show a good agreement with the experimental results and the theoretical histories of thermal stresses show a good qualitative agreement with a physical phenomena. The solutions can be applied to the problems such as a flame hardening of the cylindrical machine elements and a circular patch welding or a circular cutting of the structural member.

  • PDF

有限要素法에 依한 厚板熔接時의 3次元 非定常熱傳導解析 (Analysis on the three-dimensional unstationary heat conduciton on the welding of thick plate by F. E. M.)

  • 방한서;김유철
    • Journal of Welding and Joining
    • /
    • 제9권2호
    • /
    • pp.37-43
    • /
    • 1991
  • In order to analyze the mechanical phenomena of three dimensional elato-plastic behavior caused by welding of thick plate, it is necessary to solve exactly the three dimensional unstationary heat conduction problem considering the moving effect of heat source and the temperature-dependence of material properties. In this paper, the three-dimensional unstationary heat conduction problem is formulated by using an isoparametric finite element method. Thereafter, the transient temperature distributions, according to time, of thick plate during welding are defined from the results calculated by the developed computer program.

  • PDF

저온수열원이용 열펌프시스템의 전처리 및 성능분석 (Performance Analysis and Prior-Treatment of Heat Pump System with Low-Temperature Water Heat Source)

  • 박성룡;장기창;이상남;라호상;박준택
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.258-263
    • /
    • 2000
  • River water is higher in temperature than the surrounding environment during the winter. It is highly suitable a heat source for heat pump system. Despite its suitability, however, it is not widely used, due to its fouling and corrosive nature in heat exchanger tubes of evaporator. It is designed prior-treatment system which come into direct contact with the river water, such as auto-seamer, ozone generator for bactericidal test and auto-cleaning system. And it is analyzed treatment effects for its operation. It is designed two-stage compression heat pump system using R-134a with heating load 35.16kW, ad analyzed its performance. As a result it is obtained 3.08 COP when mid-point pressure is 1,200kPa, and bypass ratio of flowing refreigerant to high-stage compressor is 25.1%

  • PDF

제한면을 가지는 이차원 난류 충돌젯트의 유동 및 열전달 특성의 수치적 연구 (A Numerical Study of the Fluid Flow and Heat Transfer Characteristics of the Two-Dimensional Turbulent Impingement Jet with a Confinement Plate)

  • 강동진;오원태
    • 대한기계학회논문집
    • /
    • 제19권7호
    • /
    • pp.1675-1683
    • /
    • 1995
  • A numerical study of the fluid flow and heat transfer characteristics of the two-dimensional impingement jet with a confinement plate has been carried out. The fluid flow was calculated by solving the full Navier-Stokes equation. In doing that, the well known SIMPLER algorithm was used and the trouble making convection term was discretized according to QUICKER scheme. The energy equation was simply solved by using the SOR method. For the Reynolds number of 10000, two channel heights, say 1.5 and 3.0 times the jet exit width, and two thermal boundary conditions constant wall temperature and constant wall heat flux were considered. Discrete heat sources were flush mounted along the impingement plate at a distance of 0, 2, 3, 4, 5, 6, 10, 12, times the jet exit width from the stagnation point. The length of each heat source is 4 times the jet exit width long. The Nusselt number averaged over each heat source was compared with experiment. Comparison shows that both calculations and experiment have the secondary peak of Nusselt number at downstream of stagnation point, even though there is a little quantitative difference in between. The difference is believed due to abscure thermal boundary condition in experiment and also accuracy of turbulence model used. The secondary peak is shown to be caused by rigorous turbulent flow motion generated as the wall jet flow is retarded and developes into the channel flow without flow reversal.