• Title/Summary/Keyword: Point A dose

Search Result 573, Processing Time 0.021 seconds

Prophylactic Cranial Irradiation for Acute Lymphoblastic Leukemia in Childhood (소아 급성 림프모구성 백혈병의 예방적 전뇌 방사선조사)

  • Kim, In-Ah;Choi, Ihl-Bhong;Kang, Ki-Mun;Shinn, Kyung-Sub;Kim, Hack-Ki
    • Radiation Oncology Journal
    • /
    • v.14 no.2
    • /
    • pp.137-147
    • /
    • 1996
  • Purpose : This report is the result f retrospective analysis for children who received prophylactic cranial irradiation combined with intrathecal chemotherapy. Materials and Methods : Ninety children with ALL who had got bone marrow remission after induction chemotherapy received PCI. All but 3 children were treated with a dose of 1800 cGy as a standard regimen. While the PCI was given, all patients received intrathecal chemotherapy. Results : Nine of 90 patients experienced CNS relapse during the duration of follow-up ranged from 36 to 96 months (median 60 months). Three children experienced BM relapse prior to CNS relapse. Therefore, CNS relapse rate as the first adverse event was $6.7\%$. Median time interval of CNS relapse was 16 months from the first day of hematologic complete remission. Eighty-nine percent of patients who had CNS relapse were associated with hematologic relapse. and $78\%$ of CNS relpase occurred during maintenance chemotherapy (on-therapy relapse). The CNS RFS at 2 and 5 years are $68\%$ and $42\%$, respectively with median of 43 months. The Prognostic factors affecting CNS RFS are initial WBC count (cut-off point of 50,000/ul), FAB subtype and CALGB risk criteria. The DFS at 2 and 5 years are 61 and $39\%$, respectively with median of 34 months. The prognostic factors affecting DFS are initial WBC count (cut-off point of 50,000/ul), FAB subtype, POG and CALGB risk criteria. Conclusions : In our study, $6.7\%$ of CNS relapse rate as a first adverse event was comparable with other studies. Various risk criteria was based on age at diagnosis and initial WBC count such as POG and CALGB criteria, had prognostic significance for CNS RFS and DFS. Prospective randomized trial according to prognostic subgroup based on risk criteria and systematic study about neuropsychologic function for long term survivors, are essential to determine the most effective and least toxic form of CNS prophylaxis.

  • PDF

The Usefulness of Q.Clear Technique in PET / CT (PET/CT 검사에서 Q.Clear 기법의 유용성에 대한 고찰)

  • Choi, Yong Hoon;Kim, Jung Yul;Choi, Young Sook;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.31-36
    • /
    • 2017
  • Purpose Recently, the performance of PET/CT scanner has been improved and various techniques have been developed to increase the image quality such as Sensitivity and Resolution. The purpose of this study is to evaluate the usefulness of Q.Clear (a fully convergent iterative reconstruction) technique of GE Discovery IQ equipment to enhance the image quality. Materials and Methods All scans were acquired by Discovery IQ (GE Healthcare, MI, USA). In NEMA IEC Body Phantom test, Background to Hot-sphere (10 mm, 13 mm, 17 mm, 22 mm) ratio was 1:4 and scan time was 3 minutes. The images were reconstructed by VPHDs (VUE Point High-Definition + SharpIR) and Q.Clear to evaluate each Contrast. We injected 18F-FDG 187 M㏃ to PET/SPECT Performance Phantom. And then it was scanned for 4 minutes to evaluate Resolution and Uniformity. T-test statistical analysis was performed on SUVmax of small lesions less than 2 cm in 100 clinical patients regardless of disease type. Results In the NEMA IEC Body Phantom, the Contrast was $63.6{\pm}5.7%$ (VPHDs) and $75{\pm}4.8%$ (Q.Clear). In the PET/SPECT Performance Phantom, the Resolution was 9.2 mm (VPHDs) and 7.3 mm (Q.Clear). Uniformity of Q.Clear was 10.8% better than VPHDs. T-test statistic of the clinical patients showed a significant difference of p value of 0.021. Conclusion Both the phantom test and the clinical results showed that the quality of the image was improved in Q.Clear was applied. The SUVmax was highly measured in Q.Clear and the lesions were clearly distinguished visually. Therefore Q.Clear can be useful in various aspects such as dose-reduction, patients evaluation and image analysis.

  • PDF

Comparative Analysis between Preoperative Radiotherapy and Postoperative Radiotherapy in Clinical Stage I and II Endometrial Carcinoma (자궁내막암 환자에서 수술 전 방사선치료와 수술 후 방사선치료의 성적 비교 분석)

  • Keum Ki Chang;Lee Chang Geol;Chung Eun Ji;Lee Sang Wook;Kim Woo Cheol;Chang Sei Kyung;Oh Young Taek;Suh Chang Ok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.377-383
    • /
    • 1995
  • Purpose : To obtain the optimal treatement method in patients with endometrial carcinoma(clinical stage FIGO I, II) by comparative analysis between preoperative radiotherapy (pre-op RT) and postoperative radiotherapy (post-op RT). Material and Methods : A retrospective review of 62 endometrial carcinoma patients referred to the Yonsei Cancer Center for radiotherapy between 1985 and 1991 was undertaken. Of 62 patients, 19 patients(Stagel : 12 patients. Stagell;7 patients) received pre-op RT before TAH(Total Abdominal Hysterectomy) and BSO (Bilateral Salphingoophorectomy) (Group 1) and 43 patients(Stage 1;32 patients, Stage 2; 11 patients) received post-op RT after TAH and BSO (Group 2). Pre-op irradiation was given 4-6 weeks prior to surgery and post-op RT administered on 4-5 weeks following surgery. All patients except 1 patient(Group 2: ICR alone) received external irradiation. Seventy percent(13/19) of pre-op RT group and 54 percent(23/42) of post-op RT group received external pelvic irradiation and intracavitary radiation therapy(ICR). External radiation dose was 39.6-55 Gy(median 45 Gy) in 5-6. 5weeks through opposed AP/PA fields or 4-field box technique treating daily, five days per week, 180 cGy per fraction. ICR doses were prescribed to point A(20-39.6 Gy, median 39 Gy) in Group 1 and 0.5cm depth from vaginal surface (18-30 Gy,median 21 Gy) in Group 2. Results : The overall 5 year survival rate was $95{\%}$. No survival difference between pre-op and post-op RT group.($89.3{\%}$ vs $97.7{\%}$, p>0.1) There was no survival difference by stage, grade and histology between two groups. The survival rate was not affected by presence of residual tumor of surgical specimen after pre-op RT in Group 1 (p>0.1), but affected by presence of lymph node metastasis in post-op RT group(P<0.5). The complication rate of pre-op RT group was higher than post-op RT. ($16{\%}$ vs $5{\%}$) Conclusion : Post-op radiotherapy offers the advantages of accurate surgical-pathological staging and low complication rate.

  • PDF

The Results of Curative Radiation Therapy for 49 Patients of the Uterine Cervical Carcinomas (자궁 경부암의 근치적 방사선 치료 효과 -49예의 분석 -)

  • Ryu Mi Ryeong;Kim Yeon Sil;Choi Byung Ock;Yoon Sei Chul;Shinn Kyung Sub;Namkoong Sung Eun;Kim Seung Jo
    • Radiation Oncology Journal
    • /
    • v.10 no.2
    • /
    • pp.219-225
    • /
    • 1992
  • Fifty patients with carcinoma of the uterine cervix received curative radiotherapy by external irradiation of the whole pelvis and intracavitary radiation at the Department of Therapeutic Radiology, Kangnam St. Mary's Hospital from September, 1983 to October, 1986. External beam whole pelvic irradiation was done first up to 4500-5940 cGy in 5 weeks to 6.5 weeks, followed by an intracavitary radiation. Total dose of radiation to point A varied from 6500 cGy to 11344 cGy (average 6764 cGy). Of the 50 patients, one patient was lost to follow up and follow up period of the remaining 49 patients ranged from 3 months to 93 months (median 32 months). According to FIGO classification, 6 ($12.2\%$) were in stage Ib, 6 ($12.2\%$) in stage IIa, 25 ($51\%$) in stage IIb, 7 ($14\%$) in stage III, and 5 ($10.2\%$) in stage IV. Age of the patients ranged from 33 to 76 years (median 60 years). Pathologically, fourty six ($94\%$) patients had squamous cell carcinoma, 2 ($4\%$) had adenocarcinoma, and 1 ($2\%$) had adenosquamous cell carcinoma. Overall response rate was $84\%$. 5-year survival rate was $49\%$ for entire group ($75\%$ for stage Ib, $83\%$ for Stage IIa, $42.5\%$ for stage IIb, $25\%$ for stage III, $40\%$ for stage IV). Complications were observed in 11 ($22.4\%$) patients, who revealed rectal complications with most common frequency. Others were self limiting trifle ones such as wet desquamation, fatigue, mild leukopenia, etc. The correlation of the survival rate with various factors (age, dose, Hb level, pelvic lymph node status, performance status, local recurrence) was evaluated but showed no statistical significance except the age and local recurrence in this series; survival of patients less than 50 years of age was worse than that of the older, and the presence of local recurrence had worse prognosis (p<0.05).

  • PDF

Comparison of Collimator Choice on Image Quality of I-131 in SPECT/CT (I-131 SPECT/CT 검사의 에서 조준기 종류에 따른 영상 비교 평가)

  • Kim, Jung Yul;Kim, Joo Yeon;Nam-Koong, Hyuk;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.33-42
    • /
    • 2014
  • Purpose: I-131 scan using High Energy (HE) collimator is generally used. While, Medium Energy (ME) collimator is not suggested to use in result of an excessive septal penetration effects, it is used to improve the sensitivities of count rate on lower dose of I-131. This research aims to evaluate I-131 SPECT/CT image quality using by HE and ME collimator and also find out the possibility of ME collimator clinical application. Materials and Methods: ME and HE collimator are substituted as Siemens symbia T16 SPECT/CT, using I-131 point source and NEMA NU-2 IQ phantom. Single Energy Window (SEW) and Triple Energy Windows (TEW) are applied for image acquisition and images with CTAC and Scatter correction application or not, applied different number of iteration and sub set are reconstructed by IR method, flash 3D. By analysis of acquired image, the comparison on sensitivities, contrast, noise and aspect ratio of two collimators are able to be evaluated. Results: ME Collimator is ahead of HE collimator in terms of sensitivity (ME collimator: 188.18 cps/MBq, HE collimator: 46.31 cps/MBq). For contrast, reconstruction image used by HE collimator with TEW, 16 subset 8 iteration applied CTAC is shown the highest contrast (TCQI=190.64). In same condition, ME collimator has lower contrast than HE collimator (TCQI=66.05). The lowest aspect ratio for ME collimator and HE collimator are 1.065 with SEW, CTAC (+) and 1.024 with TEW, CTAC (+) respectively. Conclusion: Selecting a proper collimator is important factor for image quality. This research finding tells that HE collimator, which is generally used for I-131 scan emitted high energy ${\gamma}$-ray is the most recommendable collimator for image quality. However, ME collimator is also applicable in condition of lower dose, lower sensitive if utilizing energy window, matrix size, IR parameter, CTAC and scatter correction appropriately.

  • PDF

Performance Evaluation of Breast Specific Gamma Imaging (Breast Specific Gamma Imaging 장비의 성능평가)

  • Cha, Eun-Sun;Kwak, In-Suk;Noh, Ik-Sang;Yeon, Joon-Ho;Kim, Ki;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.24-27
    • /
    • 2010
  • Purpose: Early diagnosis of breast is of the utmost importance to improve prognosis. We have a limitation for mammography and sonography detecting small cancer. Clinical importance of Breast Specific Gamma Imaging (BSGI) has improved for that reason. So We studied performance evaluation test of count rate and resolution with high sensitivity to the low dose of BSGI. Materials and Methods: BSGI of Dilon 6800, point source of $^{99m}Tc$ from 1.85~148 MBq (0.05~4 mCi) at the intervals of 1.85~37 MBq (0.05~1 mCi) was used for the test. Performance evaluation method was performed for measuring deadtime for choosing at the 5 different point in the useful field of view (UFOV), acquired image for 60 seconds. Compared with reference of clinical uptake distribution of breast, activity increased according to the distance change 10, 20, 30, 40, 50 mm in the useful field of view. Results: Counting curve increased according to the activity from 1.85 MBq (0.05 mCi) to the 74 MBq (2 mCi), and it change flat shape over 74 MBq (2 mCi). The variation of the full width of half maximum (FWHM) to the distance is 4.05, 4.73, 5.77, 6.90, 8.00, 9.32 mm in 1.85 MBq (0.05 mCi), 4.30, 4.80, 5.90, 7.00, 8.10, 9.07 mm in 3.7 MBq (0.1 mCi), 4.90, 5.60, 6.20, 7.20, 8.20, 9.10 mm in 5.55 MBq (0.15 mCi), 5.30, 6.10, 6.60, 7.00, 7.90, 8.70 mm in 7.40 MBq (0.2 mCi). Conclusion: Distortions of image would be acquired because of the deadtime in BSGI. We found out the fact that specification of $^{99m}Tc$ reaction under 74 MBq (2 mCi) for BSGI. Second, FWHM distribution change from varied distance from the detector, clearly distinguished the location of the lesion.

  • PDF

A Study on the Cubism - In it's relation to Bergsonian Philosophy and Simultaneity - (큐비즘에 관한 연구 - 베르그송 철학과 동시성 개념을 중심으로 -)

  • Ryu, Ji-Seok;Oh, Chan-Ohk
    • Archives of design research
    • /
    • v.18 no.3 s.61
    • /
    • pp.117-128
    • /
    • 2005
  • The French Belle Epoque is a period where the literary and artistic movement was very activated. The birth of the cubism reflects this atmosphere of the times and the change of paradigm in all fields. The Bergsonism is often designated as one of the important backgrounds of cubism. The problem consists in knowing if Bergsonian ideas gave real influence on the cubist movement and up to what point. Our analysis will show that it is not homogenous and very variable according to painters. In the case of Picasso and Braques it seems be a simple inspiration of Zeitgeist. But the influence upon Metzinger and Gleizes is explicit. The text of 1912, Du cubism, prove their attachment to his thought. The key concept of cubist theory, influenced by Bergsonian philosophy, is the concept of simultaneity. Cubist simultaneity is in one hand a reflection of an artist's psychological experience and the other hand a synthesis of multiple views for grasping the object in itself by the way of conceptual representation. The temporal simultaneity could be identified with the notion of memory, which is a temporal continuity connecting the past to dynamic present. The spatial simultaneity is a juxtaposition of multiple views obtained by the movement around the object. But the dose reading of Bergson's text shows that there is a divergence between the notion of cubist simultaneity and his ideas. The biased interpretation is often, as well as the strict understanding, like the history shows us well, a great source of inspiration and creativity. The cubist mouvement is not far from this case.

  • PDF

Generative Adversarial Network-Based Image Conversion Among Different Computed Tomography Protocols and Vendors: Effects on Accuracy and Variability in Quantifying Regional Disease Patterns of Interstitial Lung Disease

  • Hye Jeon Hwang;Hyunjong Kim;Joon Beom Seo;Jong Chul Ye;Gyutaek Oh;Sang Min Lee;Ryoungwoo Jang;Jihye Yun;Namkug Kim;Hee Jun Park;Ho Yun Lee;Soon Ho Yoon;Kyung Eun Shin;Jae Wook Lee;Woocheol Kwon;Joo Sung Sun;Seulgi You;Myung Hee Chung;Bo Mi Gil;Jae-Kwang Lim;Youkyung Lee;Su Jin Hong;Yo Won Choi
    • Korean Journal of Radiology
    • /
    • v.24 no.8
    • /
    • pp.807-820
    • /
    • 2023
  • Objective: To assess whether computed tomography (CT) conversion across different scan parameters and manufacturers using a routable generative adversarial network (RouteGAN) can improve the accuracy and variability in quantifying interstitial lung disease (ILD) using a deep learning-based automated software. Materials and Methods: This study included patients with ILD who underwent thin-section CT. Unmatched CT images obtained using scanners from four manufacturers (vendors A-D), standard- or low-radiation doses, and sharp or medium kernels were classified into groups 1-7 according to acquisition conditions. CT images in groups 2-7 were converted into the target CT style (Group 1: vendor A, standard dose, and sharp kernel) using a RouteGAN. ILD was quantified on original and converted CT images using a deep learning-based software (Aview, Coreline Soft). The accuracy of quantification was analyzed using the dice similarity coefficient (DSC) and pixel-wise overlap accuracy metrics against manual quantification by a radiologist. Five radiologists evaluated quantification accuracy using a 10-point visual scoring system. Results: Three hundred and fifty CT slices from 150 patients (mean age: 67.6 ± 10.7 years; 56 females) were included. The overlap accuracies for quantifying total abnormalities in groups 2-7 improved after CT conversion (original vs. converted: 0.63 vs. 0.68 for DSC, 0.66 vs. 0.70 for pixel-wise recall, and 0.68 vs. 0.73 for pixel-wise precision; P < 0.002 for all). The DSCs of fibrosis score, honeycombing, and reticulation significantly increased after CT conversion (0.32 vs. 0.64, 0.19 vs. 0.47, and 0.23 vs. 0.54, P < 0.002 for all), whereas those of ground-glass opacity, consolidation, and emphysema did not change significantly or decreased slightly. The radiologists' scores were significantly higher (P < 0.001) and less variable on converted CT. Conclusion: CT conversion using a RouteGAN can improve the accuracy and variability of CT images obtained using different scan parameters and manufacturers in deep learning-based quantification of ILD.

Clinical Application of Wedge Factor (Wedge Factor의 임상적 응용)

  • Choi Dong-Rak;Ahn Yong-Chan;Huh Seung Jae
    • Radiation Oncology Journal
    • /
    • v.13 no.3
    • /
    • pp.291-296
    • /
    • 1995
  • Purpose : In general, the wedge factors which are used clinical practices are ignored of dependency on field sizes and depths. In this present, we investigated systematically the depth and field size dependency to determine the absorbed dose more accurately. Methods : The wedge factors for each wedge filter were measured at various depths (depth of Dmax, 5cm, 10cm, and 15cm) and field sizes ($5cm{\times}5cm,\;10cm{\times}10cm,\;15cm{\times}15cm, and 20cm{\times}20cm$) by using 4-, 6-, and 10-MVX rays. By convention, wedge factors are determined by taking the ratio of the central axis ionization readings when the wedge filter is in place to those of the open field in same field size and measurement depth. In this present work, we determined the wedge factors for 4-, 6-, and 10-MV X rays from Clinac 600C and 2100C linear accelerators (manufactured by Varian Associates, Inc., Palo Alto, CA). To confirm that the wedge was centered, measurements were done with the two possible wedge position and various collimator orientations. Results : The standard deviations of measured values are within $0.3\;\%$ and the depth dependence of wedge factor is greater for the lower energies. Especially, the variation of wedge factor is no less than $5\%$ for 4- and 6- MV X rays with more than $45^{\circ}$ wedge filters. But there seems to be a small dependence on field size. Conclusion : The results of this study show a dependence on the point of measurement. There also seems to be a small dependence on field size. And so, we should consider the depth and field size dependence in determining the wedge factors. If one wedge factor were to be used for each wedge filter it seems that the measurement for a 10cm x 10cm field size at a depth of loom would be a reasonable choice.

  • PDF

Establishment on Fertilizer Recommendation and Soil Characteristics of Rice Paddy with Environment-friendly Cultivation (농가실천 친환경 벼재배 논의 토양특성 및 시비추천량)

  • Yang, Chang-Hyu;An, Seung-Hyun;Kim, Taek-Kyum;Kim, Sun;Baek, Nam-Hyun;Choi, Weon-Young;Lee, Jang-Hee;Jeong, Jae-Hyeok;Kim, Si-Ju
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.3
    • /
    • pp.347-352
    • /
    • 2011
  • Environment-friendly agriculture (EFA) are aimed to reduce use of chemical inputs as possible the recycling of resources and the environment while preserving the local resources in the long term to ensure a constant productivity and profitability for producing safe food. This study was conducted to investigate characteristics on soil environment at paddy field of environment-friendly agriculture regions (EFARs) in Honam area. Survey point of EFARs Chungnam, Jeonbuk and Jeonnam, rice bran farming method in two districts, rice bran + snail farming method in eight districts, snail farming method in five districts and ducks farming method in three districts a total of 18 districts were selected. Annual of farming method, friendly-environment certification, amount of applied fertilizer, and history of cultivation to the farm household were surveyed. The content of available phosphate and silicate among the soil chemical properties in EFA paddy field were a little lower than optimum level, and those of agricultural methods fertilized with rice bran were a little lower than those of others. Hardness among the soil physical properties in EFA paddy field were a little lower than conventional practices, and that of agricultural methods fertilized with rice bran were a little lower than those of others. We showed fertilizer recommendation dose about soil nutritional shortages according to fertilization prescriptions index by crops.