• Title/Summary/Keyword: Point A and B

Search Result 3,345, Processing Time 0.04 seconds

A Study on Environmental Standards of School Building (교사환경기준에 관한 연구)

  • Hong, Seok-Pyo;Park, Young-Soo
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.1 no.1
    • /
    • pp.11-43
    • /
    • 2000
  • The purpose of this study was, through analyzing the previous researches, to grasp the present status of environment of school building(ESB), research the sundry records of each element and, through comparative analysis of the standard of ESB in Korea, the United States, and Japan, select the normative standard of ESB, to clarify the point at issue presented in Regulation of Construction & facility Management for Elementary and and Secondary School in Korea, and to suggest an alternative preliminary standard of ESB. To carry out a research for this purpose, these were required: 1. to investigate the existing present status of ESB, 2. to make a comparative analysis of the standard of ESB in each country, 3. to suggest the normative standard of preliminary standard of ESB, 4. to analyze the controversial points of the standard of ESB in Korea, 5. to suggest an alternative preliminary standard of ESB. The conclusions were as follows: 1. Putting, through analyzing the previous researches, the existing present status of ESB together, it seemed that lighting environment, indoor air environment and noise environment were all in poor conditions. 2. In the result of a comparative analysis of the standard of ESB in Korea, Japan and the United States, in Korea the factors of each lighting and indoor air environment were not presented properly, in Japan, in lighting environment aspect, the standard on natural lighting and the factors on brightness were not presented., and in the USA the essential factors of each environment were throughly presented. In the comparison of the standards on each factor, Korea showed that the standard level presented was less properly prescribed than those of the USA and Japan but it also showed that the standard levels prescribed in the USA and in Japan were mostly similar to the standard levels in records investigated. 3. With the result of the normative standard selection on School Builiding environment factor of prescribed in this study, the controversial points of the standard of ESB in Korea were analyzed and the result was utilized to suggest new preliminary standard of ESB. 4. As the result of the analysis of the controversial points of the standard of ESB in Korea, it was found that the standard of ESB in Korea should be established on a basis of School Health Act and be concretely presented in School Health Regulation and School Health Rule. The factors of each environment was improperly presented in the existing standard of ESB in Korea. Moreover the standard of them was inferior to that of the records investigated and those of in the USA and in Japan and it also showed that the standard of it in Korea was improper to maintain Comfortable Learning Environment. 5. A suggested preliminary standard of ESB acquired through above study as follows: 1) In this study a new kind of preliminary standard of ESB is divided into lighting environment, indoor air environment, noise environment, odor environment and for above classification, reasonable factor and standard should be established and the controling way on each standard and countermeasures against it should be considered. 2) In lighting environment, the factors of natural lighting are divided into daylight rate, brightness, glare. In the standard on each factor, daylight rate should secure 5% of a mean daylight rate and 2% of a minimum daylight rate, brightness ratio of maximum illumination to minimum illumination should be under 10:1, and in glare there should not be an occurrence factor from a reflector outside of the classroom. And the factors of unnatural lighting are illumination, brightness, and glare. In the standard on each factor, illumination should be 750 lux or more, brightness ratio should be under 3 to 1, and glare should not occur. And Optimal reflection rate(%) of Colors and Facilities of Classroom which influences lighting environment should be considered. 3) In indoor air environment factors, thermal factors are divided into (1) room temperature, (2) relative humidity, (3) room air movement, (4) radiation heat, and harmful gases (5) CO, (6) $CO_2$ that are proceeded from using the heating fuel such as oval briquettes, firewood, charcoal being used in most of the classroom, and finally (7) dust. In the standard on each factor, the next are necessary; room temperature: $16^{\circ}C{\sim}26^{\circ}C$(summer : $E.T18.9{\sim}23.8^{\circ}C$, winter: $E.T16.7{\sim}21.7^{\circ}C$), relative humidity: $30{\sim}80%$, room air movement: under 0.5m/sec, radiation heat: under $5^{\circ}C$ gap between dry-bulb temperature and wet-bulb temperature, below 1000 ppm of ca and below 10ppm of $CO_2$, dust: below 0.10 $mg/m^3$ of Volume of dust in indoor air, and ventilation standard($CO_2$) for purification of indoor air : once/6 min.(about 7 times/40 min.) in an airtight classroom. 4) In the standard on noise environment, noise level should be under 40 dB(A) and the noise measuring way and the countermeasures against it should be considered. 5) In the standard on odor environment, odor level under Physical Method should be under 2 degrees, and the inspecting way and the countermeasures against it should be considered.

  • PDF

The Definition of Connecting Flight and Extraterritorial Application of Regulation (EC) No 261/2004: A Case Comment on Claudia Wegener v. Royal Air Maroc SA [2018] Case C-537/17 (EC 261/2004 규칙의 역외적용과 연결운항의 의미 - 2018년 EU사법재판소 Claudia Wegener v. Royal Air Maroc SA 판결의 평석 -)

  • Sur, Ji-Min
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.35 no.1
    • /
    • pp.103-125
    • /
    • 2020
  • This paper reviews the EU Case, Claudia Wegener v. Royal Air Maroc SA [2018] ECLI:EU:C:2018:361, Case C-537/17. It analyzes some issues as to Wegener case by examining EU Regulations and practical point of views. Article 3(1)(a) of Regulation (EC) No 261/2004 of the European Parliament and of the Council of 11 February 2004 establishing common rules on compensation and assistance to passengers in the event of denied boarding and of cancellation or long delay of flights, entitled scope, provides: "this Regulation shall apply: (a) to passengers departing from an airport located in the territory of a Member State to which the Treaty applies; (b) to passengers departing from an airport located in a third country to an airport situated in the territory of a Member State to which the Treaty applies, unless they received benefits or compensation and were given assistance in that third country, if the operating air carrier of the flight concerned is a Community carrier." ECJ held that must be interpreted as meaning that Regulation (EC) No 261/2004 applies to a passenger transport effected under a single booking and comprising, between its departure from an airport situated in the territory of a Member State and its arrival at an airport situated in the territory of a third State, a scheduled stopover outside the European Union with a change of aircraft. According to the Court, it is apparent from the regulation and case-law that when, as in the present case, two (or more) flights are booked as a single unit, those flights constitute a whole for the purposes of the right to compensation for passengers. Those flights must therefore be considered as one and the same connecting flight.

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

A Study on the Characteristics and Vitalization Strategy for the Multi-Complex Shopping Mall (복합쇼핑몰 활성화 방안에 관한 사례연구)

  • Cha, Seong Soo;Park, Cheol
    • Journal of Distribution Research
    • /
    • v.17 no.5
    • /
    • pp.129-146
    • /
    • 2012
  • Recently, Korea became the 7th country in the world which has got into the 20-50 clubs that means the population is 50 million and per capital income is $20,000. From the view point of the retail industry, it suggests that Korea should have its own self-sufficient market by itself. With abundant labor and increased disposable income, it made the consumer's needs change. Responding to the change, retail and F&B oriented retail malls are now starting to add culture, art and entertainment facilities in the configurations. Such complexity and variety of the shopping malls became trendy and many shopping complexes are scheduled to open in the near future across the country. Due to above reasons, it became the common trend to develop shopping complex all over the cities now. However, the history of the shopping mall in Korea is much shorter than developed countries such as America and Japan. Thereby, a lot of problems, trial and error have occurred in the process of developing and operating them. If development of shopping complex failed, it would return lots of damages to the stakeholder. Therefore, the corporations should develop the mall properly and government might support positively. In this study, we would like to propose on how all the mall should be developed and well managed and what are the ways for the vitalizing factors of the shopping complex after benchmarking other shopping mall cases. Through the case study, we realized that the most crucial factors for vitalizing shopping complex were interior design, merchandising and how well they operate the mall. In case of the failed shopping mall, developers sell each store to individual proprietors and never take care of them after they get the profit, which make it hard to have integrated marketing strategies. That causes the overall slump of the mall. Corporations developing the mall should operate it as well, so that it could be possible to make the mall consistently well managed and promoted. There is a certificate for the shopping mall expert in The States and Japan. However, we do not have this kind of certificate. In fact, if we judge the capability of a person who is involved in the shopping mall industry, we usually measure how many years they stick to the same industries and that is not equally the same as their competence. Therefore it is necessary to organize "Shopping Mall Associate" and introduce shopping mall license for the mall expert. Due to retail trends, we can easily see a lot of shopping facilities all over the cities but not every mall is able to be successful. We think it's essential that the government should certify the malls which are qualified for the design, merchandising and proficiency of the operation. For the qualified mall, the government could confer a benefit on the company such as reducing corporation taxes. In multi-complex shopping mall it is possible to make convenient for customers. However, if a mall failed to succeed, it would be disaster. To build a shopping complex, developers should invest huge money even take out loan so that many people would be connected to the project, which may affect their whole financial conditions. In addition, only qualified corporation should develop and operate shopping complex and the government must support and aid the developers in order to make a better shopping environment in which customers might be happy during their shopping experience.

  • PDF

An Analytic Case Study on the Management of an Upper-level General Hospital(2010-2012)

  • Park, Hyun-Suk;Lee, Jung-Min;Baek, Hong-Suck;Lee, Jun-Ho;Park, Sang-Sub
    • Journal of Korean Clinical Health Science
    • /
    • v.2 no.1
    • /
    • pp.1-16
    • /
    • 2014
  • Purpose. For a more efficient hospital management, this study aims to provide basic data so that the hospital management and staff in charge of hospital administration may systematically classify and collect hospital information, by analyzing the ordinary characters of an upper-level general hospital system and its common-type balance sheet, common-type profit and loss statement and financial ratio. Methods. By using information about an upper-level general hospital in C Province, provided by Alio(www.alio.go.kr), a public organization information provision site, Health Insurance Review & Assessment Service(www.hira.or.kr) and Ministry of Health and Welfare(www.mw.go.kr), this study analyzed 3 year's data from 2010 to 2012 and provided basic data by analyzing the ordinary characters of an upper-level general hospital system, and its common-type balance sheet, common-type profit and loss statement and financial ratio. Results. After analyzing the ordinary characters, common-type balance sheet, common-type proft and loss statement and financial ration of this general hospital, based on the 2010 to 2012 data, this study came to the following conclusions. Firstly, out of all the 1,069 hospital staff, there were 272 doctors working for 24 medical departments, out of whom the majority was 33 physicians. Most of the nurses were third-class ones, and about 2,000 outpatients and 600 inpatients on average were treated per day. Secondly, as a result of analyzing the common-type balance sheet, this study discovered that intangible assets out of fixed assets accounted for 41%, the majority, out of which usable and profitable donation asset buildings were of great importance, and the liquid assets increased more in 2012 than 2011. In the financial structure, the ratio of liquid liabilities was over 50% out of all the liabilities in 2012, and the ratio of purchase payables was high as well. The ratio of fixed liabilities reached up to 40%, out of which the retirement benefit appropriation fund was quite high. The capital was over 80%, but the surplus was in a deficit state. Compared to the capital, the ratio of total liabilities was about 90%, which indicates the financial structure of this general hospital was vulnerable. Thirdly, as a result of analyzing the common-type profit and loss statement, this study found out that the medical profits from inpatients were higher than profits from outpatients. The material cost was related to the medical quality of this general hospital, and it was as high as 30% out of the total costs and was about 45% of the labor cost. This general hospital showed 10% in the ratio of non-medical profits, and it seemed because of government subsidies. The ratios of medical profits and current net income were gradually changing for the better in 2012, compared to 2011. Lastly, as a result of analyzing the financial ratio, it was found that the liquidity ratio kept decreasing, from 110.7% in 2010 and 102.0% in 2011 to 77.2% in 2012. Besides, it was analyzed that the liquidity ratio and the net working capital ratio greatly decreased, while the quick ratio and the liquid ratio kept decreasing. Conclusions. 1. It is necessary to take the risk management into more consideration, and particularly, it is needed to differentiate and manage the levels of risk in detail. 2. By considering the fact that investments into hospital infrastructures were mostly based on liabilities, it is needed to deal with the scale of losses when evaluating risks. 3. By reflecting the character that investments into hospital infrastructures were based on liabilities, it is necessary to consider the ratio of ordinary profits as well as the ratio of operating profits to sales, and it is also important to consider sales productivity factors, such as the sales amount per a sickbed, by comparing them with other hospitals. As for limitations of this study, there may be some problems in terms of data interpretation because of the lack of information about the number of inpatients and the number of outpatients per year, which are needed for the break-even point analysis. Besides, to suggest a direction for the improvement of hospital management through analyses, non-financial factors should be reflected, such as the trend of economy, medical policies, and politic backgrounds. However, this study only focused on the common-type balance sheet, common-type profit and loss statement and financial ratio, so this study is actually limited to generalizing all the factors by analyzing public data only.

Effect of Acute Ethanol Intoxication on the Pulmonary Compliance and Surfactant in Rats (급성(急性) Ethyl 알콜 중독(中毒) 흰쥐의 폐용압률(肺容壓率)과 폐포활성물질(肺胞活性物質)의 변화(變化))

  • Lee, Seung-Jung;Choo, Young-Eun
    • The Korean Journal of Physiology
    • /
    • v.15 no.1
    • /
    • pp.27-36
    • /
    • 1981
  • Relatively little has been done on the metabolic changes of the lung produced by the excessive alcohol ingestion to the point of the acute alcohol intoxication. In the present study, an effort was made to clarify the possible changes of the pulmonary surfactant system by the acute alcohol ingestion. The dynamic pulmonary compliance and the levels of protein and inorganic phosphorus (Pi) of both lung lavage and extract were chosen as the parameters of the pulmonary surfactant activities. The albino rats of both sexes were used, and 1.5 ml of 50% ethanol per 100 g body weight was given by oral intubation, and the experiment was performed at 1, 3, 6, 12, and 24 hours after the alcohol ingestion. The rat was sacrificed by cutting the carotid arteries, and blood sample for the determination of hematocrit(Hct) and the blood alcohol concentration was obtained. Both lungs were completely removed without dammage to the lung tissue, and the pulmonary compliance was measured by the changes of pressure-volume(P-V) curves by inflating or deflating the lung with air. Immediately after the P-V curves were recorded, the lung lavage was obtained by washing the lobes with 15ml of isotonic saline 3 times with a syringe. Next, total lungs were homogenized and filtered to obtain the lung extract. The protein and Pi levels were measured using the lung lavage and extract as the samples, and the lung/body weight ratio(L/B ratio) was also calculated. The results thus obtained were compared with the normal values and summarized as follows. The blood alcohol concentration reached the highest level of $0.71{\pm}0.02\;g\;%$ at 1 hr and gradually decreased until 24 hrs$(0.36{\pm}0.02\;g%)$ after the alcohol ingestion, but all the experimental groups showed significant increase comparing with the normal. The highest Hct value was obtained at 1hr$(64.86{\pm}2.45%)$ and significantly elevated value was continued throughout the experiment. The L/B ratio was significantly lowered from 3hrs until 24hrs after the alcohol ingestion but from 6 th hr on, a generally elevated value was observed with a significant value at 12 hrs and gradual recovery to the normal value at 24 hrs after the alcohol ingestion. The pulmonary compliance at inflation and deflation did not change appreciablly from the normal until 3 hrs after the alcohol ingestion but from 6 th hr on, a generally elevated value was observed with a significant value at 12 hrs and gradual recovery to the normal value at 24 hrs after the alcohol ingestion. The protein level of the lung lavage stowed a significantly increased value of $12.36{\pm}0.35\;mg/gm(3rd hr)$, $12.70{\pm}0.74\;mg/gm(12 th hr)$, and $12.65{\pm}0.88\;mg/gm(24 th hr)$, respectively, comparing with the normal value of $10.65{\pm}0.62\;mg/gm$, and the Pi level also showed a similar tendency of significant increase at 12th hr $(7.65{\pm}0.63\;{\mu}mol/gm)$ and 24 th hr$(6.70{\pm}0.36\;{\mu}mol/gm)$ comparing with the normal value of $5.32{\pm}0.20\;{\mu}mol/gm$. The protein level of the lung extract in the alcohol group was generally similar to the normal value with a slight decrease at 1st and 3 rd hr, tut the Pi level of the lung extract was generally increased in the alcohol group, and a significant increase was observed at 6 th hr$(17.77{\pm}1.54\;{\mu}mol/gm)$, 12 th hr$(13.92{\pm}0.78\;{\mu}mol/gm)$ and 24 th hr$(14.57{\pm}0.53\;{\mu}mol/gm)$ of the alcohol ingestion comparing with the normal value of $10.34{\pm}0.37\;{\mu}mol/gm$. From the above, it may be concluded that the acute alcohol intoxication produces the metabolic changes of the lungs by the increased surfactant activities and elevated pulmonary compliance.

  • PDF

Study on the Improvement of Stow Net Fishing Technique and the Enlargement of Fishing Ground to the Distant Waters - 1 . Model Experiment of the Net - (안강망어법의 개량과 어장의 원해로의 확대를 위한 연구 - 1 . 어구의 모형실험 -)

  • Lee, Byoung-Gee;Kim, Jin-Kun;Lee, Ju-Hee
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.24 no.2
    • /
    • pp.55-64
    • /
    • 1988
  • Stow nets have widely been used in the western sea of Korea from the olden age. The original structure of a stow net is a large square-sectional bag net made of 4 netting panels, and the front fringes of top and bottom panels are connected to the top and bottom beams respectively. Wire ropes, which is originated from the holding anchor are gradually forked and biforked, and finally 4 pieces of wire rope (biforked pendants) are jointed to each beam. Much convenience caused by long and heavy beams were problemed, then some studies have been carried out to improve the net since 1930's. The most effective improvement were achieved in 1980 by Mr. Han and his colleagues. The key point of improvement was that the beams were removed and the belt shaped shearing device made by canvas was attached to the side panels, the head rope and ground rope to the front fringe of top and bottom panel, and biforked pendants are joined to the shearing device. Even though this is the epoch-making improvement of a stow net, the further study should be required to find out more effective method. The authors carried out a model experiment on the stow net to determine the vertical and horizontal opening of a net mouth, and also examine the front, top and side-view configuration of the net. The model net was constructed depending on the Similarity Law of Fishing Gear in 1/10 and 1/20 scale and set against to the current at shallow and speedy flowing channel. The vertical and horizontal openings were determined by using scaled bamboo poles, and the configuration was observed by using specially prepared observation platform and underwater observation glass, and also photographed by using specially prepared underwater photographic equipment. The results obtained can be summarized as follows: 1. The opening height and width of the shearing device varied in accordance with the relative length of the biforked pendants. Considering the height and width of shearing device in 6 cases of the arrangement system of biforked pendants, the best result was obtained in the case that the 2nd, 3rd and 4th pendents from the bottom-most was 5%, 9% and 4% longer than that. 2. On the top-view configuration the excessive deformation of head rope and ground rope were observed. In the actual net, 54m long head rope and ground rope were attached to the front fringe of top and bottom panels so that the head rope may be lifted to make the net mouth open highly. But actually the head rope and the ground rope are streamed backward without any lift, and also the netting followed the ropes were deformed until the 2/5 in the whole length of the net. This deformation may be guessed to disturb the entrance of fish school into the net and also caused the net to get caught by obstacles in the sea bed and to be broken largely. 3. Hydrodynamic resistance R of the actual net may be deduced as R(kg)=29.2$\times$103 v1.65. It is also expressed as R(kg)=5.9$\times$d/l$\times$ab v1.65. depending on the formula deduced by Koyama to estimate the resistance of trawl nets, where d/l denote the ratio between diameter of netting twine and length of mesh leg in every part of side panel, a and b, the stretched circumference of the mouth and the stretched length of the net, respectively.

  • PDF

A Low Tillering Ideotype of Rice Plant for Increasing Grain Yield Potential (벼 수량성 증가를 위한 이상적인 소얼성 초형)

  • Kim, Je-kyu;Vergara, B.S.
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.36 no.2
    • /
    • pp.134-142
    • /
    • 1991
  • Since IR8, the first high-yielding rice cultivar characterised by semidwarf and high-tillering, was released in 1966, rice yields during the last two decades have apparently reached a plateau and subsequent efforts to further improve yielding ability have not resulted in visible gains. At this point of time, a new ideotype of rice plant would be necessary to increase grain yield potential. This experiment was conducted to investigate the yield contribution of different tillers within a plant in relation to an ideo type of rice plant. A low-tillering, large panicled IR25588 was compared with a high-tillering, small panicled IR58. Based on spikelet number and grain weight per panicle, the top six panicles in both low- and high-tillering cultivarswere significantly bigger than those in the other panicles. The top six panicles were M, PI, P2, P3, P4 and S1P2 in both cultivars. Their tillers had 100% probability of occurring. The top six tillers were characterised by earlier initiation and heading, longer growth duration, greater leaf area. and heavier culm and total dry weight per tiller. The top six panicles, based on grain weight was mainly due to higher spikelet number per panicle with little differences in 1,000 grain weight and percent fertility. They had also a greater number of high -density grains. The top six panicles were significantly bigger than the rest of the panicles in both low- and high-tilliering types suggesting that a new rice ideotype having six or fewer potential tillers or panicles per paint with 200 to 250 spikelets per panicle (a low-tillering, paicle weight type) may help increase grain yield potential since they have been shown to be superior physio-morphologically to the rest of the tillers.

  • PDF

A Study on Analysis of Investment Effects of Farm Mechanization, Korea -Mainly on the Case Study of Saemaeul Farm Mechanization Groups in Nonsan Area, Chungnam Province- (농업기계화(農業機械化)의 투자효과분석(投資效果分析)에 관(關)한 연구(硏究) -충남논산지역(忠南論山地域) 새마을 기계화영농단(機械化營農團)을 중심(中心)으로-)

  • Lim, Jae Hwan;Han, Gwan Soon
    • Korean Journal of Agricultural Science
    • /
    • v.14 no.1
    • /
    • pp.164-185
    • /
    • 1987
  • The Korean economy has been developed rapidly in the course of implementing the five year economic development plans since 1962. Accordingly the industrial and employment structure have been changed from the traditional agriculture to modem industrial economy. In the course of implementing export oriented industrialization policies, rural farm economy has been encountered labour shortage owing to rural farm population drain to urban areas, rural wage hike and pressure on farm operation costs, and possibility of farm productivity decrease. To cope with the above problems the Korean government has supplied farm machinery such as power tillers, tractors, transplanters, binders, combines, dryers and etc. by means of the favorable credit support and subsidies. The main objectives of this study are to identify the investment effects of farm mechanization such as B/C and Internal Rate of Return by machinery and operation patterns, changes of labour requirement per 10a for rice culture since 1965, partial farm budget of rice with and without mechanization, and estimation labour input with full mechanization. To achieve the objectives Saemaeul farm mechanization groups, common ownership and operation, and farms with private ownership and operation were surveyed mainly in Nonsan granary area, Chungnam province. The results of this study are as follows 1. The national average of labor input per 10a of paddy has decreased from 150.1Hr in 1965 to 87.2Hr in 1985 which showes 42% decrease of labour inputs. On the other hand the hours of labour input in Nonsan area have also decreased from 150.1Hr to 92.8Hr, 38% of that in 1965, during the same periods. 2. The possible labor saving hours per 10a of Paddy was estimated at 60 hours by substituting machine power for labor forces in the works of plowing, puddling, transplanting, harvesting and threshing, transporting and drying The labor savings were derived from 92.8 hours in 1986 deducting 30 hours of labor input with full mechanization in Nonsan area. 3. Social benefits of farm mechanization were estimated at 124,734won/10a including increment of rice (10%): 34,064won,labour saving: 65,800won,savings of conventional farm implements: 18,000 won and savings of animal power: 6,870won. 4. Rental charges by works prevailing in the area were 12,000won for land preparation, 15,000won for transplanting with seedlings, 19,500won for combine works and 6,000won for drying paddy. 5. Farm income per 10a of paddy with and without mechanization were amounted to 247,278won and 224,768won respectively. 6. Social rate of return of the machinery were estimated at more than 50% in all operation patterns. On the other hand internal rate of return of the machinery except tractors were also more than 50% but IRR of tractors by operation patterns were equivalent to 0 to 9%. From the view point of farmers financial status, private owner-operation of tractors is considered uneconomical. Tractor operation by Saemaeul mechanization groups would be economical considering the government subsidy, 40% of tractor price. 7. Farmers recommendations for the government that gained through field operation of farm machinery are to train maintenance technology for rural youth, to standardize the necessary parts of machinery, to implement price tag system, to intercede spare parts and provide marketing information to farmers by rural institutions as RDA,NACF,GUN office and FLIA.

  • PDF

Mechanical and Rheological Properties of Rice Plant (수도(水稻)의 역학적(力學的) 및 리올러지 특성(特性)에 관(關)한 연구(硏究))

  • Huh, Yun Kun;Cha, Gyun Do
    • Korean Journal of Agricultural Science
    • /
    • v.14 no.1
    • /
    • pp.98-133
    • /
    • 1987
  • The mechanical and rheological properties of agricultural materials are important for engineering design and analysis of their mechanical harvesting, handling, transporting and processing systems. Agricultural materials, which composed of structural members and fluids do not react in a purely elastic manner, and their response when subjected to stress and strain is a combination of elastic and viscous behavior so called viscoelastic behavior. Many researchers have conducted studies on the mechanical and rheological properties of the various agricultural products, but a few researcher has studied those properties of rice plant, and also those data are available only for foreign varieties of rice plant. This study are conducted to experimentally determine the mechanical and the rheological properties such as axial compressive strength, tensile strength, bending and shear strength, stress relaxation and creep behavior of rice stems, and grain detachment strength. The rheological models for the rice stem were developed from the test data. The shearing characteristics were examined at some different levels of portion, cross-sectional area, moisture content of rice stem and shearing angle. The results obtained from this study were summarized as follows 1. The mechanical properties of the stems of the J aponica types were greater than those of the Indica ${\times}$ Japonica hybrid in compression, tension, bendingand shearing. 2. The mean value of the compressive force was 80.5 N in the Japonica types and 55.5 N in the Indica ${\times}$ Japonica hybrid which was about 70 percent to that of the Japonica types, and then the value increased progressively at the lower portion of the stems generally. 3. The average tensile force was about 226.6 N in the Japonica types and 123.6 N in the Indica ${\times}$ Japonica hybrid which was about 55 percent to that of the Japonica types. 4. The bending moment was $0.19N{\cdot}m$ in the Japonica types and $0.13N{\cdot}m$ in the Indica ${\times}$ Japonica hybrid which was 68 percent to that of the Japonica types and the bending strength was 7.7 MPa in the Japonica types and 6.5 MPa in the Indica ${\times}$ Japonica hybrid respectively. 5. The shearing force was 141.1 N in Jinju, the Japonica type and 101.4 N in Taebaeg, the Indica ${\times}$ Japonica hybrid which was 72 percent to that of Jinju, and the shearing strength of Taebaeg was 63 percent to that of Jinju. 6. The shearing force and the shearing energy along the stem portion in Jinju increased progressively together at the lower portions, meanwhile in Taebaeg the shearing force showed the maximum value at the intermediate portion and the shearing energy was the greatest at the portion of 21 cm from the ground level, and also the shearing strength and the shearing energy per unit cross-sectional area of the stem were the greater values at the intermediate portion than at any other portions. 7. The shearing force and the shearing energy increased with increase of the cross-sectional area of the rice stem and with decrease of the shearing angie from $90^{\circ}$ to $50^{\circ}$. 8. The shearing forces showed the minimum values of 110 N at Jinju and of 60 N at Taebaeg, the shearing energy at the moisture content decreased about 15 percent point from initial moisture content showed value of 50 mJ in Jinju and of 30 mJ in Taebaeg, respectively. 9. The stress relaxation behavior could be described by the generalized Maxwell model and also the compression creep behavior by Burger's model, respectively in the rice stem. 10. With increase of loading rate, the stress relaxation intensity increased, meanwhile the relaxation time and residual stress decreased. 11. In the compression creep test, the logarithmic creep occured at the stress less than 2.0 MPa and the steady-state creep at the stress larger than 2.0 MPa. 12. The stress level had not a significant effect on the relaxation time, while the relaxation intensity and residual stress increased with increase of the stress level. 13. In the compression creep test of the rice stem, the instantaneous elastic modulus of Burger's model showed the range of 60 to 80 MPa and the viscosities of the free dashpot were very large numerical value which was well explained that the rice stem was viscoelastic material. 14. The tensile detachment forces were about 1.7 to 2.3 N in the Japonica types while about 1.0 to 1.3 N in Indica ${\times}$ Japonica hybrid corresponding to 58 percent of Japonica types, and the bending detachment forces were about 0.6 to 1.1 N corresponding to 30 to 50 percent of the tensile detachment forces, and the bending detachment of the Indica ${\times}$ Japonica hybrid was 0.1 to 0.3 N which was 7 to 21 percent of Japonica types. 15. The detachment force of the lower portion was little bigger than that of the upper portion in a penicle and was not significantly affected by the harvesting period from September 28 to October 20. 16. The tensile and bending detachment forces decreased with decrease of the moisture content from 23 to 13 percent (w.b.) by the natural drying, and the decreasing rate of detachment forces along the moisture content was the greater in the bending detachment force than the tensile detachment force.

  • PDF