• Title/Summary/Keyword: Pohang ozone

Search Result 28, Processing Time 0.023 seconds

Characteristics on the Variations of the Total Ozone over Pohang (1994-2004) using the Brewer Spectrophotometer and TOMS

  • Hong Gi-Man;Choi Byoung-Cheol;Goo Tae-Young;Lim Jae-Chul;Lim Byung-Sook;Baek Moon-Hee
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.388-391
    • /
    • 2005
  • The characteristics of the total ozone variations measured by the ground-based Brewer Ozone Spectrophotometer and the Total Ozone Mapping Spectrometer (TOMS) over Pohang are statistically examined from January 1994 to December 2004. First of all, in the correlation analysis of the total ozone measured from the Brewer Ozone Spectrophotometer and the TOMS, the correlation coefficient was 0.88 and the used data were 2190. The annual mean value of the total ozone is 311 DU with the standard deviation of 13 DU. The maximum and the minimum value were found in March (343 DU) and in September (282 DU), respectively. It was also revealed that the longest seasonal variation is in Spring (341 DU) and the smallest is in Autumn (283 DU). The time series data of the total ozone indicates that the annual variation is significant and the variations for three months and six months are relatively weak. Finally, the annual mean total ozones in Pohang (Brewer), Seoul (Brewer) and Busan (TOMS) are 312 DU, 324 DU and 304 DU, respectively.

  • PDF

The origin and seasonal characteristics of tropospheric ozone observed over Pohang, Korea

  • Kim, Jae-Hwan;Lee, Hyun-Jin
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.59-60
    • /
    • 2003
  • In this study, we present the analysis of vertical ozone sounding data observed over Pohang, Korea, and investigate to understand the governing mechanisms for seasonal ozone maximum in June. The vertical ozone profiles in June show that the ozone enhancement is clearly shown in the middle and upper troposphere. We have found that the June maximum is associated with the transport of ozone rich air from the stratosphere and polluted continental air mass. This is different from the previous studies shown that the regionally polluted continental air mass, influenced by the intense anthropogenic activities m northeast Asia during transport, is responsible for the ozone maximum in spring.

  • PDF

Evaluation of the Troposphere Ozone in the Reanalysis Datasets: Comparison with Pohang Ozonesonde Observation (대류권 오존 재분석 자료의 품질 검증: 포항 오존존데와 비교 검증)

  • Park, Jinkyung;Kim, Seo-Yeon;Son, Seok-Woo
    • Atmosphere
    • /
    • v.29 no.1
    • /
    • pp.53-59
    • /
    • 2019
  • The quality of troposphere ozone in three reanalysis datasets is evaluated with longterm ozonesonde measurement at Pohang, South Korea. The Monitoring Atmospheric Composition and Climate (MACC), European Centre for Medium-Range Weather Forecasts Interim Reanalysis (ERAI) and Modern Era Retrospective-Analysis for Research and Applications version 2 (MERRA2) are particularly examined in terms of the vertical ozone structure, seasonality and long-term trend in the lower troposphere. It turns out that MACC shows the smallest biases in the ozone profile, and has realistic seasonality of lower-tropospheric ozone concentration with a maximum ozone mixing ratio in spring and early summer and minimum in winter. MERRA2 also shows reasonably small biases. However, ERAI exhibits significant biases with substantially lower ozone mixing ratio in most seasons, except in mid summer, than the observation. It even fails to reproduce the seasonal cycle of lower-tropospheric ozone concentration. This result suggests that great caution is needed when analyzing tropospheric ozone using ERAI data. It is further found that, although not statistically significant, all datasets consistently show a decreasing trend of 850-hPa ozone concentration since 2003 as in the observation.

Characterization of Ozone Distributions in Pohang: Measurement Data during 2002~2006 (포항지역 오존농도의 분포 특성: 2002~2006년 측정자료)

  • Lim, Ho-Jin;Lee, Yong-Jik
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.1
    • /
    • pp.50-62
    • /
    • 2011
  • Temporal trends and spatial distributions of ozone concentrations in Pohang were investigated using data measured at 4 air quality monitoring stations (i.e., Daedo, Jukdo, Jangheung, and Desong) during 2002-2006. The monthly mean ozone concentrations were highest during April and June and decreased during July and August, which follows the typical trend in the Northeast Asia region. The high springtime ozone concentration might have been strongly influenced by the enhanced photochemical ozone production of accumulated precursors during the winter under increased solar radiations. In July and August, ozone levels were decreased by frequent and severe precipitation that caused lower mean monthly solar radiation and efficient wash-out of ozone precursors. This suggests that precipitation is extremely beneficial in the aspect of ozone pollution control. High ozone concentrations exceeding 80ppb dominantly occurred in May and June during the late afternoon between 16:00~17:00. Ozone concentrations were higher in Jangheung and Daesong relative to Daedo and Jukdo, whereas total oxidants $(O_3+NO_2)$ were higher in Jangheung and Daedo. In the suburban area of Daesong, ozone concentrations seem to be considerably higher than those in urban sites of Daedo and Jukdo due to lower ozone loss by NO titration with lower local NO level.

Evaluation of Vertical Ozone Profiles from Ozonesonde over Pohang, Korea against coinciding HALOE datasets

  • Hwang, Seung-Hyun;Sohn, Byung-Ju
    • Journal of the Korean earth science society
    • /
    • v.27 no.7
    • /
    • pp.778-786
    • /
    • 2006
  • In Korea, the ozone profiles have been acquired by using ozonesonde at Pohang station of the Korea Meteorological Administration (KMA) since 1995. These ozone soundings were performed at 0500 UTC on a weekly basis (every Wednesday) in a clear sky. The ozonesonde is equipped with the model 5A ECC sensor, which is one of the most common ozonesonde systems. There have been no attempts to evaluate the Pohang ozonesonde profiles compared with satellite. This paper will provide the first evaluation results for the ozonesonde profiles against HALogen Occultation Experiment (HALOE) measurements over Korea. During 1995-2004 periods, a total of 450 and 188 ozone profiles were obtained from the ozonesonde measurements from HALOE measurements over Korea, respectively. Hence, a total of 34 coincident profile pairs are extracted. Among those total profiles, 26 profiles from ozonesonde are compared against nearly coincident HALOE measurements in time and space. For ozone profiles, the results of statistical analyses showed that the best agreement between two measurements occurs in the 20-25 km and 30-35 km region, where the mean and RMS percent differences are less than ${\pm}5$ and 14%, respectively. For temperature profiles, the mean and RMS percent differences in 20-25 km region are estimated to be about -0.1 and 1.7%, respectively. According to the scatter plots between two measurements, ozone data are strongly correlated each other above 20 km altitude range with more than 0.8 correlation coefficients. It is found that the altitude (pressure level) differences between two measurements would mainly lead to the discrepancy (over 40% below 18 km) below 20 km in ozone profiles.

The Characteristics of Superposed Ozonizer using Three-Phase Voltage (3상전압을 이용한 중첩방전형 오존발생기의 특성)

  • Kim, Yeong-Hun;Chun, Byung-Joon;Song, Hyun-Jig;Youn, Young-Dae;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2259-2261
    • /
    • 1999
  • In this paper, an ozonizer, which can generate individual and superposed silent discharge, using three-phase voltage has been designed and manufactured. The ozonizer consists of 3 electrodes(Central Electrode, Internal Electrode and External Electrode) and 2 gaps(gap between Central Electrode and Internal Electrode, gap between Internal Electrode and External Electrode). Ozone is generated according to voltage supplying method to each electrode by individual silent discharge and three-phase superposed discharge. The characteristics of ozone generation were investigated with variation of discharge power and the quantity of supplied gas($O_2$). In case of individual silent discharge, the maximum values of ozone concentration, ozone generation and ozone yield were obtained between internal electrode and external electrode, and its values were 2300[ppm], 570[mg/h] and 745[g/kWh] respectively. Each maximum values was 5039[ppm], 1773[mg/h] and 851[g/kWh] respectively, when three-phase superposed silent discharge was employed. Therefore, characteristics of ozone generation with three-phase voltage are improved compared with single-phase voltage because silent discharge is generated continuously.

  • PDF

Characteristics of near-surface ozone distribution

  • Kim, Yoo-Keun;Lee, Hwa-Woon;Kim, Jae-Hwan;Moon, Yun-Seob;Song, Sang-Keun
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.4 no.3
    • /
    • pp.127-137
    • /
    • 2000
  • This study presents an analysis of the characteristics of vertical ozone distribution near the surface using ozonesonde data(l995 to 1998), plus surface ozone and meteorological data from the Pohang region. These features were examined in detail using three case studies. The first related to episodes of high surface ozone concentrations during the Spring season when the frontogenesis between the high and low pressure associated with the upper-level jet stream was found to be located near the surface. The second was a 5-day winter period(l3 -17 December, 1997) in the Pohang province when the hourly concentrations exceeded 90 ppb on several occasions owing to low-level jets(LLJs) induced by a nocturnal stable layer. Accordingly, this explains why the high surface ozone concentrations occurred at night as the ozone was transported across the zone by a strong wind speed( over 12.5 ms .1). The third case study was ozone enhancement due to photochemical reactions. In this case, the maximum concentration of ozone exceeded 60 ppb in the summer(23 -28 August, 1997). When an ozone peak appeared within the boundary layer, the occurrence frequency of a low-level jet due to the nocturnal stable layer was about 77%, similarly the occurrence frequency of a near-surface ozone peak relative to the appearance of an LLJ was about 76%. Accordingly, there is clearly a close correlation between the occurrence of LLJs and near-surface ozone peaks.

  • PDF

Estimation of Vertical Profiles and Total Amount of Ozone Using Two-Dimensional Photochemical Transfer Model During the Period of 1995-1996 at Pohang (2차원 광화학수송모델을 이용한 포항지역의 1995-1996년 기간동안 오존의 연직 프로파일 및 전량 추정)

  • Moon, Yun-Seob
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.3
    • /
    • pp.271-285
    • /
    • 2006
  • A two-dimensional photochemical transport model (2D PTM) is simulated to describe the transport and chemical reaction of ozone related to aerosols in the troposphere and stratosphere. The vertical profiles and total amounts of ozone, which are advected by both residual Eulerian circulation and the adiabatic circulation under certain circumstance, have been compared with the observation data such as ozonesondes, Brewer spectrometer, the Upper Atmosphere Research Satellite (UARS), and the Total Ozone Mapping Spectrophotometer (TOMS). As a result, we find that the observed distribution of ozone Is adequately reproduced in the model at middle and high latitude in the Northern Hemisphere as well as at Phang ($36^{\circ}\;02'N,\;129^{\circ}\;23'E$) in South Korea. In particular, the 2D PTM is well simulated in the ozone decrease due to the Pinatubo volcanic eruption in 1991. However, ozone mixing ratio are more underestimated than those of UARS and ozonesondes, because are very sensitive to the latitude of transport across the tropopause associated with both Rummukainen errors and off-line model. Relative mean bias errors and relative root mean square errors of ozone calculations using the 2D PTM are shown within${\pm}10%$, respectively.

Characteristics of Vertical Ozone Distributions in the Pohang Area, Korea (포항지역 오존의 수직분포 특성)

  • Kim, Ji-Young;Youn, Yong-Hoon;Song, Ki-Bum;Kim, Ki-Hyun
    • Journal of the Korean earth science society
    • /
    • v.21 no.3
    • /
    • pp.287-301
    • /
    • 2000
  • In order to investigate the factors and processes affecting the vertical distributions of ozone, we analyzed the ozone profile data measured using ozonesonde from 1995 to 1997 at Pohang city, Korea. In the course of our study, we analyzed temporal and spatial distribution characteristics of ozone at four different heights: surface (100m), troposphere (10km), lower stratosphere (20km), and middle stratosphere (30km). Despite its proximity to a local, but major, industrial complex known as Pohang Iron and Steel Co. (POSCO), the concentrations of surface ozone in the study area were comparable to those typically observed from rural and/or unpolluted area. In addition, the findings of relative enhancement of ozone at this height, especially between spring and summer may be accounted for by the prevalence of photochemical reactions during that period of year. The temporal distribution patterns for both 10 and 20km heights were quite compatible despite large differences in their altitudes with such consistency as spring maxima and summer minima. Explanations for these phenomena may be sought by the mixed effects of various processes including: ozone transport across two heights, photochemical reaction, the formation of inversion layer, and so on. However, the temporal distribution pattern for the middle stratosphere (30km) was rather comparable to that of the surface. We also evaluated total ozone concentration of the study area using Brewer spectrophotometer. The total ozone concentration data were compared with those derived by combining the data representing stratospheric layers via Umkehr method. The results of correlation analysis showed that total ozone is negatively correlated with cloud cover but not with such parameter as UV-B. Based on our study, we conclude that areal characteristics of Pohang which represents a typical coastal area may be quite important in explaining the distribution patterns of ozone not only from surface but also from upper atmosphere.

  • PDF