• 제목/요약/키워드: Pneumatic Chamber

검색결과 73건 처리시간 0.02초

공압제진대용 이중챔버형 공압스프링의 복소강성 모형화 (Amplitude-dependent Complex Stiffness Modeling of Dual-chamber Pneumatic Spring for Pneumatic Vibration Isolation Table)

  • 이정훈;김광준
    • 한국소음진동공학회논문집
    • /
    • 제18권1호
    • /
    • pp.110-122
    • /
    • 2008
  • Pneumatic vibration isolator typically consisting of dual-chamber pneumatic springs and a rigid table are widely employed for proper operation of precision instruments such as optical devices or nano-scale equipments owing to their low stiffness- and high damping-characteristics. As environmental vibration regulations for precision instruments become more stringent, it is required to improve further the isolation performance. In order to facilitate their design optimization or active control, a more accurate mathematical model or complex stiffness is needed. Experimental results we obtained rigorously for a dual-chamber pneumatic spring exhibit significantly amplitude dependent behavior, which cannot be described by linear models in earlier researches. In this paper, an improvement for the complex stiffness model is presented by taking two major considerations. One is to consider the amplitude dependent complex stiffness of diaphragm necessarily employed for prevention of air leakage. The other is to employ a nonlinear model for the air flow in capillary tube connecting the two pneumatic chambers. The proposed amplitude-dependent complex stiffness model which reflects dependency on both frequency and excitation amplitude is shown to be very valid by comparison with the experimental measurements. Such an accurate nonlinear model for the dual-chamber pneumatic springs would contribute to more effective design or control of vibration isolation systems.

이중챔버를 이용한 공압 가진기의 주파수 범위 확장 (Frequency range expansion of pneumatic exciter by using dual-chamber)

  • 박영우;김광준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 추계학술대회 논문집
    • /
    • pp.815-824
    • /
    • 2013
  • Pneumatic exciters can be good replacements of electrodynamic, piezoelectric and hydraulic exciters owing to simple structure and large exciting force. One problem to be solved is a slow response caused by compressibility of air. Desirable frequency response characteristics of exciter are constant magnitude and zero degree phase, because users want no time delay between input signal and output force. For this reason, frequency range of pneumatic exciters is limited about 0~1 Hz. Therefore, expansion of frequency range is an important issue when designing the pneumatic exciter. In this paper, the pneumatic exciter which has same structure with active pneumatic isolator is dealt with. The dynamic characteristics are presented, and its limitation of expanding frequency range is shown based on analytical studies. Then the pneumatic exciter with dual-chamber is suggested to overcome this problem. Based on simulation study, a design method is presented.

  • PDF

등온화용기를 이용한 공기압 기기의 성능계측 (Characteristics Measurement of Pneumatic Elements Using Isothermal Chamber)

  • 장지성
    • 동력기계공학회지
    • /
    • 제4권1호
    • /
    • pp.20-25
    • /
    • 2000
  • In this study, methods for the characteristics measurement of pneumatic elements using isothermal chamber, the methods for the flow rate and dynamic characteristic measurement of pneumatic control valve, are proposed. An isothermal chamber is a chamber in which the steel wool is stuffed and isothermal condition can almost be realized. Therefore, the instantaneous flow rate could be measured only from the pressure response using the state equation of gas. Effectiveness and simplicity of the proposed method are confirmed by comparing the measured results obtained by proposed methods with the methods defined JIS and the ISO standards.

  • PDF

High Precision Pressure Control of a Pneumatic Chamber using a Hybrid Fuzzy PID Controller

  • Liu, Hao;Lee, Jae-Cheon;Li, Bao-Ren
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제8권3호
    • /
    • pp.8-13
    • /
    • 2007
  • A hybrid fuzzy PID controller for a pneumatic chamber is proposed in this paper. First, a mathematical model of a pneumatic pressure servocontrol system was developed where separate implementations of a PID controller and a fuzzy controller were made. The experimental results using a step input signal revealed that the PID controller accurately controlled the steady-state pressure but did not robustly handle parameter variations in the system while the fuzzy controller provided a fast rise time and low overshoot of the pressure in the system. In order to attain the advantages of both the fuzzy and PID controllers, a hybrid control scheme was developed. The experimental results show that the hybrid fuzzy PID controller proposed in this study does indeed possess the advantages of both PID and fuzzy controllers. Hence, it can be concluded that the hybrid fuzzy PID controller is suited for high-precision control of pressure in a pneumatic chamber.

지반진동절연을 위한 공압제진대의 전달률 설계기법 (An Efficient Transmissibility-design Technique for Pneumatic Vibration Isolator)

  • 이정훈;김광준
    • 한국소음진동공학회논문집
    • /
    • 제18권4호
    • /
    • pp.411-423
    • /
    • 2008
  • Pneumatic vibration isolator has a wide application for ground-vibration isolation of vibration-sensitive equipments. Recent advances In precision machine tools and instruments such as nano-technology or medical devices require a better isolation performance, which can be efficiently done by precise modeling- and design- of the isolation system. This paper will discuss an efficient transmissibility design method for pneumatic vibration isolator by employing the complex stiffness model of dual-chamber pneumatic spring developed in our previous research. Three design parameters of volume ratio between the two pneumatic chambers, the geometry of capillary tube connecting the two pneumatic chambers and finally the stiffness of diaphragm necessarily employed for prevention of air leakage were found to be important factors in transmissibility design. Based on design technique that maximizes damping of dual-chamber pneumatic spring, trade-off among the resonance frequency of transmissibility, peak transmissibility and transmissibility in high frequency range was found, which was not ever stated in previous researches. Furthermore this paper will discuss about negative role of diaphragm in transmissibility design. Then the design method proposed in this paper will be illustrated through experiment at measurements.

이중챔버를 이용한 공압가진기의 주파수 범위 확장 (Frequency Range Expansion of Pneumatic Exciter by Using Dual-chamber)

  • 박영우;김광준
    • 한국소음진동공학회논문집
    • /
    • 제23권10호
    • /
    • pp.909-919
    • /
    • 2013
  • Pneumatic exciters can be good replacements of electrodynamic, piezoelectric and hydraulic exciters owing to simple structure and large exciting force. One problem to be solved is a slow response caused by compressibility of air. Desirable frequency response characteristics of exciter are constant magnitude and zero degree phase, because users want no time delay between input signal and output force. For this reason, frequency range of pneumatic exciters is limited about 0~1 Hz. Therefore, expansion of frequency range is an important issue when designing the pneumatic exciter. In this paper, the pneumatic exciter which has same structure with active pneumatic isolator is dealt with. The dynamic characteristics are presented, and its limitation of expanding frequency range is shown based on analytical studies. Then the pneumatic exciter with dual-chamber is suggested to overcome this problem. Based on simulation study, a design method is presented.

OWC형 파력발전 공기챔버의 공기감쇠력 실험연구 (An Experimental Study of Pneumatic Damping at the Air Chamber for OWC type Wave Energy Device)

  • 최학선;류재문;홍석원;김진하
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2004년도 학술대회지
    • /
    • pp.138-144
    • /
    • 2004
  • Pneumatic damping through a orifice type duct for OWC type wave energy device is studied experimentally. Forced oscillation tests are made to measure chamber pressure and velocity of air flaw through orifice. Pneumatic damping coefficient are deducted from the experimental research, and discussion are made far the influence of frequency, heave amplitude, and orifice size. Finally two formula are proposed for the estimation of non-dimensional pneumatic damping coefficient by regression analysis. The proposed formula proves to be a reliable method far practical application.

  • PDF

공기압실린더의 누설유량 계측에 관한 연구 (A Study on the Measurement Method of Leakage for Pneumatic Cylinder)

  • 장지성;지상원
    • 동력기계공학회지
    • /
    • 제11권4호
    • /
    • pp.98-102
    • /
    • 2007
  • In this study, a measurement method of leakage flow-rate for pneumatic driving apparatus is proposed. The existing measurement methods of leakage flow-rate of air need disassemble the test component. Therefore, there is no effective method to measure the leakage flow-rate while operating pneumatic driving apparatus. In this study, the leakage flow-rate is measured from the pressure change in an isothermal chamber that can realize isothermal conditions by stuffing the steel wool into it. Therefore, a wide range of flow-rate could be measured only from the pressure response and the leakage flow-rate can be measured during operating pneumatic driving apparatus. The effectiveness of the proposed method is proved by experimental results.

  • PDF

공압실린더의 누설유량 계측방법에 관한 연구 (A Study on the Measurement Method of Leakage Flow-rate for Pneumatic Cylinder)

  • 장지성;지상원;정지현;강보식
    • 유공압시스템학회논문집
    • /
    • 제3권1호
    • /
    • pp.15-19
    • /
    • 2006
  • In this study, a measurement method of leakage flow-rate for pneumatic driving apparatus is proposed. The existing measurement methods of leakage flow-rate of air need disassemble the test component. Therefore, there is no effective method to measure the leakage flow-rate while operating pneumatic driving apparatus. In this study, the leakage flow-rate is measure from the pressure change in an isothermal chamber that can realize isothermal conditions by stuffing steel wool into it. Therefore, wide range of flow-rate could be measured only from the pressure response and the leakage flow-rate can be measured during operating pneumatic driving apparatus. The effectiveness of the proposed method is proved by experimental results.

  • PDF

공압 쿠션 실린더의 충격압 흡수를 위한 스프링형 니들밸브의 동특성에 관한 연구 (Simulation Study on Dynamic Analysis of Spring Type Needle Valve to Absorb Surge Pressure in Pneumatic Cushion Cylinder)

  • 이재구;;이준;이재천;신현명
    • 유공압시스템학회논문집
    • /
    • 제2권1호
    • /
    • pp.15-22
    • /
    • 2005
  • The purpose of this study is to find the effective dynamic characteristics of an improved pneumatic cushion cylinder with a spring type needle valve. The dynamic model represented the peak pressure control method when the pneumatic cushion cylinder is moving forward or backward in the horizontal direction. It was found from the simulation results that the peak pressure in the cushion chamber is affected by the spring, which helps to understand the performance of the pneumatic cushion cylinder and to improve or design a better cushion needle valve component. From the simulation results, the stability of pneumatic cushion cylinder with a spring type needle valve was superior and its cushion capability was also better than that without the spring.

  • PDF