• Title/Summary/Keyword: Plating technique

Search Result 154, Processing Time 0.029 seconds

Ni Nanoparticle Anchored on MWCNT as a Novel Electrochemical Sensor for Detection of Phenol

  • Wang, Yajing;Wang, Jiankang;Yao, Zhongping;Liu, Chenyu;Xie, Taiping;Deng, Qihuang;Jiang, Zhaohua
    • Nano
    • /
    • v.13 no.11
    • /
    • pp.1850134.1-1850134.10
    • /
    • 2018
  • Increasing active sites and enhancing electric conductivity are critical factors to improve sensing performance toward phenol. Herein, Ni nanoparticle was successfully anchored on acidified multiwalled carbon nanotube (a-MWCNT) surface by electroless plating technique to avoid Ni nanoparticle agglomeration and guarantee high conductivity. The crystal structure, phase composition and surface morphology were characterized by XRD, SEM and TEM measurement. The as-prepared Ni/a-MWCNT nanohybrid was immobilized onto glassy carbon electrode (GCE) surface for constructing phenol sensor. The phenol sensing performance indicated that Ni/a-MWCNT/GCE exhibited an amazing detection performance with rapid response time of 4 s, a relatively wide detection range from 0.01 mM to 0.48 mM, a detection limit of $7.07{\mu}M$ and high sensitivity of $566.2{\mu}A\;mM^{-1}\;cm^{-2}$. The superior selectivity, reproducibility, stability and applicability in real sample of Ni/a-MWCNT/GCE endowed it with potential application in discharged wastewater.

Over-current characteristics of YBCO coated conductors having Cu stabilizer (구리 안정화재가 있는 YBCO 박막형 초전도 선재의 과전류 통전 특성)

  • Yim, S.W.;Du, H.I.;Kim, H.R.;Hyun, O.B.;Sohn, S.H.;Lim, J.H.;Hwang, S.D.;Oh, S.Y.;Han, B.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.10 no.1
    • /
    • pp.10-14
    • /
    • 2008
  • Differently from BSCCO tapes which are fabricated by powder-in-tube method, the coated conductors are made by the evaporation of YBCO on metal substrate. Due to this structural merit, although the coated conductors are generally used for large current transportation, they are expected to be favorable to the purpose of the fault current limitation as well. In this study, using YBCO coated conductor having copper stabilizer formed by plating technique(produced by Superpower Co.), we investigated the over-current characteristics of the coated conductor. The coated conductors had 85 A $I_c$ and 90 K $T_c$. The resistance of the conductor was 0.93 $m{\Omega}/cm$ at 300 K and 0.17 $m{\Omega}/cm$ at the temperature right above $T_c$. To the coated conductors, we applied the voltages of the range from 150 $V_{rms}$ to 230 $V_{rms}$ and measured the V-I curves using four probe method. From the results, we could analyze the electric behavior of the coated conductor in flux flow state. As the current exceed $I_c$, the currents were distributed into the superconductor and metal stabilizer. The amounts of the currents shared through both current paths were calculated under the assumption that the ,Joule heating was perfectly eliminated by $LN_2$ surrounding the conductor. Finally, the condition for the stable current flowing state which does not affect the conductor was established from the analysis on the over-current characteristics.

Comparison of an Automated Most-Probable-Number Technique TEMPO®TVC with Traditional Plating Methods PetrifilmTM for Estimating Populations of Total Aerobic Bacteria with Livestock Products (축산물가공품에서 건조필름법과 TEMPO®TVC 검사법의 총세균수 비교분석)

  • Kim, Young-Jo;Wee, Sung-Hwan;Yoon, Ha-Chung;Heo, Eun-Jeong;Park, Hyun-Jeong;Kim, Ji-Ho;Moon, Jin-San
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.1
    • /
    • pp.103-107
    • /
    • 2012
  • We compared between an automated most-probable-number technique $TEMPO^{(R)}$TVC and traditional plating methods $Petrifilm^{TM}$ for estimating populations of total aerobic bacteria in various livestock products. 257 samples randomly selected in local retail stores and 87 samples inoculated with $E.$ $coli$ ATCC 25922, $Staphylococcus$ $aureus$ ATCC 12868 were tested in this study. The degree of agreement was estimated according to the CCFRA (Campden and Chorleywood Food Research Association Group) Guideline 29 and the agreement indicates the difference of two kinds methods is lower than 1 log base 10($log_{10}$). The samples of hams, jerky products, ground meat products, milks, ice creams, infant formulas, and egg heat formed products were showed above 95% in the agreement of methods. In contrast, proportion of agreement on meat extract products, cheeses and sausages were 93.1%, 92.1%, 89.1%, respectively. One press ham and five sausages containing spice and seasoning, two pork cutlets containing spice and bread crumbs, two meat extract product and two natural cheeses and one processing cheese with a high fat content, and one ice cream containing chocolate of all samples showed the discrepancy. Our result suggest that $TEMPO^{(R)}$TVC system is efficient to analyses total aerobic bacteria to compare manual method in time-consuming and laborious process except livestock products having limit of detection.

Wear Behaviors of WC-CoCr and WC-CrC-Ni Coatings Sprayed by HVOF (고속화염 용사법으로 제조된 WC-CoCr 코팅과 WC-CrC-Ni 코팅의 내마모 거동)

  • Lee, Seoung Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.204-211
    • /
    • 2020
  • The high-velocity oxy-fuel (HVOF) thermal spraying coating technique has been considered a promising replacement for traditional electrolytic hard chrome plating (EHC), which caused environmental pollution and lung cancer due to toxic Cr6+. In this paper, two types of cermet coatings were prepared by HVOF spraying: WC-CoCr and WC-CrC-Ni coatings. The produced coatings were analyzed extensively in terms of the micro-hardness, porosity, crystalline phase and microstructure using a hardness tester, optical microscopy, X-ray diffraction, and scanning electron microscopy (including energy dispersed spectroscopy (EDS)), respectively. The wear and friction behaviors of the coatings were evaluated comparatively by reciprocating sliding wear tests at 25 ℃, 250 ℃, and 450 ℃. The results revealed correlations among the microstructures, metallic binder matrixes, porosities, and wear performance of the coatings. For example, WC-CoCr coatings showed better sliding wear resistance than WC-CrC-Ni coatings, regardless of the test temperature due to the more homogeneous microstructure, Co-rich, Cr-rich metallic binder matrix, and lower porosity.

Clinical Features of Distal Tibial Fractures and Treatment Results of Minimally Invasive Plate Osteosynthesis (원위 경골 골절의 임상양상 및 최소 침습적 금속판 고정술의 결과)

  • Kim, Weon-Yoo;Ji, Jong-Hun;Kwon, Oh-Soo;Park, Sang-Eun;Kim, Young-Yul;Kil, Ho-Jin;Jeong, Jae-Jung
    • Journal of Korean Foot and Ankle Society
    • /
    • v.16 no.2
    • /
    • pp.94-100
    • /
    • 2012
  • Purpose: The purpose of this study is to analyze the clinical features of distal tibia fractures and to evaluate the treatment outcomes of minimally invasive plate osteosynthesis (MIPO). Materials and Methods: From January 2004 to December 2009, 84 cases of 81 patients treated with plate fixation for distal tibia fracture were enrolled in this retrospective review. We investigated age, sex, injury mechanism, fracture patterns, and complications, and the clinical features were analyzed. To evaluate the treatment outcomes of MIPO, we divided into two groups. MIPO group consisted of 55 patients were treated with MIPO technique and conventional group consisted of 18 patients were treated with open reduction and internal fixation with conventional anterolateral plating. The results were compared between two groups by assessing bony union time, operation time, amount of blood loss, range of ankle motion, clinical score by American Orthopaedic Foot and Ankle Society (AOFAS) score, and post-operative complications. Results: The mean age of 81 patients with distal tibia fracture was 54.8 years. According to AO classification, A1:2:3 were 16, 20, 16 patients, B1:2:3 were 2, 8, 7, C1:2:3 were 1, 3, 11 patients. According to injury mechanism, slip down injury was patients, traffic accident was 26, fall from height injury was 14 patients respectively. The type A fractures were lower energy trauma and more older patients. The type C fractures were higher energy trauma and younger patients. MIPO group was better than conventional group in operative time, blood loss, bony union time, and ankle joint motion. In complications, MIPO group showed no nonunion and infection, one malunion, one skin necrosis, nine skin irritations, and one screw breakage. Conventional group showed two nonunion, four infections, two skin necrosis, and one metal failure. Conclusion: Distal tibial fractures caused by low energy trauma were on the increase. Minimal invasive plate osteosynthesis was shorter bony union time and operation time, less blood loss, and larger ankle motions than conventional open reduction and plate fixation.

Patterns of Mercury Concentrations in Blood and Urine After High Mercury Exposure (고농도 수은 노출자의 혈 중 및 뇨 중 수은 농도 변화에 관한 연구)

  • 윤충식;임상혁;하권철
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.3
    • /
    • pp.71-80
    • /
    • 2001
  • Blood and urine mercury level of three workers were monitored during 60~80 days after high exposure to mercury at the silver refining plant. Mercury was used to form silver-mercury amalgam from plating sludge. Workers were exposed to mercury about 70 days at the several processes, such as hand held weaving, vibration table, and heating from the furnace. mercury was analysed by atomic absorption spectroscopy-vapor generation technique. Recovery from the biological sample was 95.51% and pooled standard deviation was 0.033. At the time of study, there was no work at the workplace. So, airborne mercury concentration was measured with area sampling 5 days after the work, ranged from 0.1459 to 1.2351 mg/㎥(Arithmatic mean 0.4711 mg/㎥, Geometric mean 0.3566 mg/㎥) at the inside of the plant, that is far above the ACGIH's TLV(0.025 mg/㎥) and ranged from 0.0073 to 0.0330 mg/㎥ at the outdoor. Blood mercury levels at the beginning of the monitoring were 4~14 times greater than the American Conference of Governmental Industrial Hygienists Biological Exposure Index(ACGIH BEI, 15 ug/L). Blood mercury levels were decreased logarithmically, that is, rapidly at the high level and slowly at the low level but sustained above the level of the ACGIH BEI 60~80 days after the work. Urine mercury levels at the beginning of the monitoring were 8~16 times greater than the ACGIH BEI(35 ug/g creatinine). Urine mercury levels were decreased logarithmically, but correlation between urine level and off-days were lower than those of blood. Decreasing pattern of blood mercury levels were little affected than that of urine levels when the chelating agent, D-penicillamine, was administered. There was correlation between blood mercury level and urine mercury level(0.81~0.83) but it didn\`t mean that the highest blood mercury level corresponded the highest urine mercury level. In our study, Case 1 always shows the highest level in urine but case 3 always shows the highest level in blood. Creatinine correction represented better correlations between urine mercury levels and blood levels, and between urine levels and off-days rather than by urine volume. Spot urine sampling had a wide variation than that of whole day urine sampling. So, We recommend spot urine sampling for screening and whole day urine sampling for exact diagnosis.

  • PDF

Improvement of Anti-Corrosion Characteristics for Light Metal in Surface Modification with Sulfuric Acid Solution Condition (경금속 표면개질 시 황산 수용액 조건에 따른 내식성 개선 효과)

  • Lee, Seung-Jun;Han, Min-Su;Kim, Seong-Jong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.223-229
    • /
    • 2015
  • Surface modification is a technology to form a new surface layer and overcome the intrinsic properties of the base material by applying thermal energy or stress onto the surface of the material. The purpose of this technique is to achieve anti-corrosion, beautiful appearance, wear resistance, insulation and conductance for base materials. Surface modification techniques may include plating, chemical conversion treatment, painting, lining and surface hardening. Among which, a surface modification process using electrolytes has been investigated for a long time in connection with research on its industrial application. The technology is highly favoured by various fields because it provides not only high productivity and cost reduction opportunities, but also application availability for components with complex geometry. In this study, an electrochemical experiment was performed on the surface of 5083-O Al alloy to determine an optimal electrolyte temperature, which produces surface with excellent corrosion resistance under marine environment than the initial surface. The experiment result, the modified surface presented a significantly lower corrosion current density with increasing electrolyte temperature, except for $5^{\circ}C$ of electrolyte temperature at which premature pores was created.

Ingredient analysis of 태환이식 excavated from 황남대총 남분 and the characteristics (황남대총 남분출토 태환이식의 성분분석과 그 특징)

  • Ju, Jin-ok;Kang, Dai-il
    • 보존과학연구
    • /
    • s.27
    • /
    • pp.129-143
    • /
    • 2006
  • This report is on a scientific investigation of 3 pairs of 금제태환이식 which were excavated from 황남대총 납분. 태환 is a main part of 태환이식 and it could be classified with 4 types in how to produce, especially how many the golden petal was used. In this investigation, they,3 pairs of 금제태환이식 from 황남대총 남분, were in 3 of 4 types and also I could find that this result was not on the technical progress but on the ingredient of metal. Also, In the result of ingredient assay, I could find that although they were in one pair of 태환 one piece was made in gold and silver alloy and the other piece was made in 99.5 percent of pure Ag with gold amalgam plating. And the another pair was getting red from others because of making in 33percent of Ag and 77 percent of gold, high Ag content. And All pairs of 태환 have a small quantity of Copper. As above, although they are one pair they have the difference of how to produce and the difference of volume and ingredient content, it means that these pairs of 태환 from 황남대총 남분 were made in pressure of time. From now on, if we investigate the ingredient and how to produce of 태환이식 in the local comparative analysis, namely natural science method, we can find out the metal art technique and the social aspect of the ancient times as not analogical inference but scientific basis.

  • PDF

Isolation of Nematophagous Fungi against Root-knot Nematode and Their Growth in Vitro (뿌리혹 선충에 대한 기생 천적 진균 분리 및 이들의 생장에 미치는 환경조사)

  • 정미정;김희규
    • Korean journal of applied entomology
    • /
    • v.27 no.3
    • /
    • pp.149-158
    • /
    • 1988
  • Nematophagous fungi were successfully isolated by baited plating, centrifugation technique of soil, and direct isolation from naturally ingested nematodes. Predominant seven fungi isolated were identified as Artheobotrys arthroboteyides, A.conoides, A. oligospora, Dactylella lobata, Fusatium oxysporum, Monacrosporium ellopsoporum and Harposporium anguillu-lae. Of these, six fungi were tested for cultural characteristics except. H, anguillulae, extre-mely fastidious fungus in artificial media. Among 14 media tested in this experiment, Corn-meal Agar (CMA) and Oatmeal Agar (OMA) were the most suitable media for growing all six nematophagous fungi. Weakly saprophytic M. ellipsospoyum also grew vigoroualy on these two media. The radial growth, dry weight and sporulation of the fungi tested were quite diverse depending on the culture media. D. lobata revealed good growth and abundantly sporulated on Glucoes Peptone Agar (GPA). Although over-all growth of F, oxysporum was not satisfactory on Sucrose Nitrate Agar (SNA), the sporulation was best on this medium. Optimum conditious for mycelial growth and sporulation of nematophagous fungi ranged pH 5-8 and 20-$30^{\circ}C$ on SNA. D. lobata and F, oxysporum grew vigorously and most profusely sporulated on all media tested. They turned out an most promising biocontrol agents for their aggressive growth and sporulation over the ranges of temperature and pH ranges.

  • PDF

Evaluation of cytotoxicity of electroplated stainless steel orthodontic wire (전기도금한 교정용 스테인레스스틸 선재의 세포독성에 관한 연구)

  • Lee, Gye-Hyeong;Cho, Jin-Hyoung;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.35 no.2 s.109
    • /
    • pp.127-136
    • /
    • 2005
  • The purpose of this study was to examine the cytotoxicity of orthodontic wire which had an increased diameter through electroplating, and to evaluate its possible clinical applications, First. nickel plating was carried out on the commercially available stainless steel wire using an electroplating technique For the comparison of the electroplated wire with ready made stainless steel wire and titanium or copper. each wire was incubated for 72 hours in a medium. The release of the metal ion was measured using ICP-AES (Inductively Coupled Plasma Atomic Emission Spectrophotometer). Balb/c 3T3 mouse fibroblast was put on a microplate and placed in an incubated medium of 75%, 50%, and 20% dilation. An MTT analysis was used to compare with the medium only. The change in absorbency value of each wire group and the difference of absorbency value according to the change of dilution was measured The results of ICP-AES analysis showed that great amount nickel iou was isolated from electroplated orthodontic wires and great amount copper ion was isolated from copper. The results of the MTT analysis showed that there was no difference in the absorbency value of titanium at any dilution. However, the electroplated wires (p<0.001) the stainless steel wires (p<0.05) and the copper (P<0.001) were statistically significantly lower than those of medium only at all dilutions. Assessment as per ISO 10993, part 5, showed that electroplated wire was alloted to 'moderate cytotoxic' the titanium and stainless steel wire were 'non-cytotoxic' The results of this study indicate that the electroplated orthodontic wires need additional efforts to decrease cytotoxicity for their clinical applications.